  • Hello! I've reviewed the user manual for the Morse Automatic Control Package for Tilt-To-Load Drum Tumblers. This document provides instructions on setting rotation time, starting, stopping, and recovering operations of the drum tumbler. I'm ready to assist you with any questions you may have about operating this equipment.
  • How do I adjust the rotation time?
    How do I start the rotation cycle?
    How do I stop the rotation?
    How to restart after a stop?
    How do I reset the rotator to the beginning?
MORSE MFG. CO., INC. 727 West Manlius Street P.O. Box 518 East Syracuse, NY 13057-0518
Phone: 315-437-8475 Fax: 315-437-1029 Email: service@MorseDrum.com Webpage: MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL311 (245345) (Updated August 24, 2010 1:39 PM) 1
The Specialist In Drum Handling Equipment
Automatic Control Package
for Tilt-To-Load Drum Tumblers
Operating Instructions for Morse Automatic Control Package for Tilt-To-Load Drum Tumblers
with Serial Number 245345
Operating Instructions
Adjust the timer: using the small buttons on the timer, set the desired time of rotation to the nearest tenth of 1.
a minute.
Press the green “START” button to begin the cycle: 2.
a. The drum holder will rise to the top position
b. Start the slow speed rotation for about 5 seconds
c. Rotate at the high speed setting (The high speed setting is adjusted using the black knob on the top of the
hydraulic manifold – see image above. If the black knob is turned fully clockwise, the drum will rotate at full
speed. As the black knob is turned counterclockwise, the high speed setting is lowered.)
d. Stop rotating after the preset time has been reached
e.Lowersbacktotheoorintheuprightposition.
If at any time the operator needs to stop the rotator, the red emergency stop or the red “STOP” button can
3.
be pressed and the rotation will stop. One of two actions can then be performed:
a. To restart rotation from that point, press and release the black “RECOVERY” button, then press the green
“START” button to restart the rotation from the point it was stopped and rotate until the end of the timer
cycle.
b. To reset the rotator to the beginning of the cycle, without waiting through the timer cycle, press and hold
theblack“RECOVERY”buttonuntilthedrumholdercomestorestontheoor. 
If the safety switch interrupts the process by opening the gate on a safety enclosure, for example, follow step
4.
3 to recover after closing the gate.