GPI-32 General Purpose Input Interface Installation and Operation Manual
INSTALLATION
Installation Guidelines
Please examine your GPI-32 carefully for any damage that may have been sustained
during shipping. If any is noted, please notify the shipper immediately and retain the
packaging for inspection by the shipper. The package contains the GPI-32, 9 VAC
@ 1 amp wall power transformer, USB-RS-232 Smart adapter cable, RJ-11 cable and
“S9” DB-9 female adapter, DB-9 straight-thru serial cable and this manual.
NOTE: All connections are noted on the top cover label.
Input connections:
The two plug-in euroblock screw terminals (TB-1 & 2) are labeled “Inputs” 1 thru
16 and “Inputs” 17 thru 32. The last two screw terminals (17 & 18) on each plug-in
euroblock are the ground connections. Each input is optically isolated and inter-
nally power by 5 vdc. Connect your equipment to the appropriate screw terminal
and either of the GND terminals. Contact closures, TTL logic and/or open collec-
tors may be used to activate each input. A valid input must be 40ms or greater and
is indicated by a “wink” on the “DATA’ led.
NOTE: The two female DB-37 connectors are designed to directly mate to the
StarGuide II/III relay card connector via the supplied cables. The pin-outs for
the DB-37’s are listed below.
J5, Inputs 1 thru 16 J6, Inputs 17 thru 32
Input 1, pin 1 Input 17, pin 1
Input 2, pin 2 Input 18, pin 2
Input 3, pin 3 Input 19, pin 3
Input 4, pin 4 Input 20, pin 4
Input 5, pin 6 Input 21, pin 6
Input 6, pin 7 Input 22, pin 7
Input 7, pin 8 Input 23, pin 8
Input 8, pin 9 Input 24, pin 9
Input 9, pin 11 Input 25, pin 11
Input 10, pin 12 Input 26, pin 12
Input 11, pin 13 Input 27, pin 13
Input 12, pin 14 Input 28, pin 14
Input 13, pin 16 Input 29, pin 16
Input 14, pin 17 Input 30, pin 17
Input 15, pin 18 Input 31, pin 18
Input 16, pin 19 Input 32, pin 19
Ground pins on both J5 & J6: Pins 20, 21, 22, 23, 25, 26, 27, 28, 29, 30, 31, 32,
34, 35, 36, 37
Pins not used on both J5 & J6: Pins 5, 10, 15, 24, 33
CAUTION!
Installation of the GPI-
32 in high RF environ-
ments should be per-
formed with care. It is
recommended that all
cables connected to the
GPI-32 be looped
through ferrite cores to
suppress RF. Surge
protection with RF fil-
tering such as the
Tripp-Lite “ISOBAR 4
or 6” is also suggested
for the wall trans-
former. Shielded cable
is suggested for all
input connections. The
shields and station
ground should be tied
to the “CHASSIS
GROUND” screw ter-
minal. For lightning
protection devices,
check out
www.polyphaser.com
and www.itwlinx.com.