Real Fyre DVI Owner's manual

Type
Owner's manual

This manual is also suitable for

Real Fyre DVI is an advanced gas log set that offers a realistic and convenient way to enjoy the ambiance of a wood-burning fireplace without the hassle and mess. With its simple installation and easy-to-use features, the Real Fyre DVI is a great choice for anyone looking to add warmth and beauty to their home.

Real Fyre DVI is an advanced gas log set that offers a realistic and convenient way to enjoy the ambiance of a wood-burning fireplace without the hassle and mess. With its simple installation and easy-to-use features, the Real Fyre DVI is a great choice for anyone looking to add warmth and beauty to their home.

1
LOG SET IMPORTANT INFORMATION
CAUTION...............WARNING...............IMPORTANT
USE ONLY PETERSON REAL FYRE BURNERS AND VALVES WITH THIS REAL FYRE LOG SET.
Important: Adequate ventilation is absolutely
necessary. Adequate spacing
between the logs is NECESSARY
and MUST be maintained. Some
carbon build up (sooting) may occur
where fl ames strike the logs. If carbon
build up (sooting) continues, correct
log placement before sooting becomes
worse.
This product is only warranted when used as part of a Robert H. Peterson Co. vented burner system.
WARNING: Use ONLY Peterson Real Fyre direct
vent inserts with this Real Fyre gas log
set. Failure to do so may result in
property damage or personal injury,
and will void listings, certifi cations,
and invalidate claims made to RHP.
Contact your local Real Fyre dealer if you
need more information.
This instruction contains log set and ember placement for these Real Fyre logs. You must position and
maintain the log layout as shown here to ensure proper operation of the direct vent insert. Incorrect log
installation could cause fl ame impingement and improper combustion, resulting in soot and/or excessive
by-products of combustion. DO NOT add any additional embers for this installation. Any additional embers
will cause unsafe operation. Use these logs only with a Peterson direct vent insert.
If you experience a continued accumulation of black carbon (soot) on your logs, the glass panel, or refractory
panels, it is an indication of incomplete combustion and you must correct the log placement as instructed
in this manual. If signifi cant sooting continues, stop using this gas log set.
Important: HANDLE LOGS WITH CARE AT ALL TIMES.
Please read these instructions completely and carefully.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
L-A2-429REV 0 - 1705040945
LOG SET IMPORTANT INFORMATION
CAUTION...............WARNING...............IMPORTANT
USE ONLY PETERSON REAL FYRE DIRECT VENT INSERTS WITH THIS REAL FYRE LOG SET.
CHARRED ANCIENT OAK LOG PLACEMENT INSTRUCTIONS
DVL-30-2CO shown
This log set is to be installed along
with the glowing embers and bryte
coals that are supplied with your
direct vent insert.
2
CAUTION: Burn hazard! Logs will remain hot for some time after
use. If you need to reposition any log to maintain the proper
layout, use heat resistant gloves or allow logs adequate time
to cool before handling.
Failure to use Peterson burners and valves may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
burners (and parts) ONLY.
L-A2-429
REV 0 - 1705040945
CAUTION: Burn hazard! Logs will remain hot for some time after
use. If you need to reposition any log to maintain the proper
layout, use heat resistant gloves or allow logs adequate time
to cool before handling.
Failure to use Peterson burners and valves may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
burners (and parts) ONLY.
Failure to use Peterson direct vent inserts may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
direct vent inserts ONLY.
3
Charred Ancient Oak Log Placement Instructions (25" model)
IV
I
II
III
V
DVL-25-2CO
PARTS LIST
All items for this log set are included in one (1) box.
CAUTION: Burn hazard! Logs will remain hot
for some time after use.
1
2
DVCL-17BR
DVCL-25BF
6
DVCL-7
3
5
DVCL-8Y
DVCL-8
1
Place the rear log (log #1) as shown. The bottom
of the log has two holes that align with two pegs
found on the burner.
Separate glowing embers
and place as shown here
Separate a portion of the glowing embers into
small pieces and evenly place them along the
rear and center burner ports as shown.
2
2
Place the left and right front log pieces (log #2)
as shown. The bottom of the logs each have two
holes that align with the pegs found on the burner.
Separate glowing embers
and place as shown here
(top view above front log)
Separate the remaining glowing embers into small
pieces and evenly place them along the front and
center burner ports as shown.
Separate bryte coals and
place as shown here
(top view above front log)
Separate the bryte coals into small pieces and
evenly place them above the front glowing embers
as shown.
4
DVCL-9
4
Charred Ancient Oak Log Placement Instructions (25" model) (Cont.)
VI
VII
Place the left and middle top logs (logs #3 and #4)
as shown. The bottom logs have notches to aid in
positioning the top logs.
Place the right and middle top logs (logs #5 and
#6) as shown. The logs below have notches to aid
in positioning the top logs.
4
3
6
5
5
Charred Ancient Oak Log Placement Instructions (30" model)
IV
I
II III
V
CAUTION: Burn hazard! Logs will remain
hot for some time after use.
DVL-30-2CO
PARTS LIST
1
2
3
6
4
DVCL-18BR
DVCL-30BF
All items for these log sets are included in one (1) box.
DVCL-12
1
Place the rear log (log #1) as shown. The bottom
of the log has two holes that align with two pegs
found on the burner.
Separate glowing embers
and place as shown here
Separate a portion of the glowing embers into
small pieces and evenly place them along the
rear burner ports, ember screen, and front carry
over ports as shown.
2
2
Place the left and right front log pieces (log #2)
as shown. The bottom of the logs each have two
holes that align with the pegs found on the burner.
Separate glowing embers
and place as shown here
(top view above front log)
Separate the remaining glowing embers into small
pieces and evenly place them along the front and
center burner ports as shown.
Separate bryte coals and
place as shown here
(top view above front log)
Separate the bryte coals into small pieces and
evenly place them above the front glowing embers
as shown.
DVCL-11Y
DVCL-11
5
DVCL-13
7
DVCL-9Y
6
Charred Ancient Oak Log Placement Instructions (30" model) (Cont.)
Place the left and middle top logs (logs #3 and #4)
as shown. The bottom logs have notches to aid in
positioning the top logs.
VI
VII
VIII
Place the left and right top logs (logs #5 and #6)
as shown. The logs below have notches to aid in
positioning the top logs.
Place the right top log (log #7) as shown. The logs
have notches to aid in positioning the top log.
7
4
3
6
5
7
Charred Ancient Oak Log Placement Instructions (36" model)
IV
I
II III
V
CAUTION: Burn hazard! Logs will remain
hot for some time after use.
DVL-36-2CO
PARTS LIST
1
2
3
5
4
DVCL-21BR
DVCL-36BF
All items for these log sets are included in one (1) box.
DVCL-12
1
Place the rear log (log #1) as shown. The bottom
of the log has two holes that align with two pegs
found on the burner.
Separate glowing embers
and place as shown here
Separate a portion of the glowing embers into
small pieces and evenly place them along the
rear burner ports, ember screen, and front carry
over ports as shown.
2
2
Place the left and right front log pieces (log #2)
as shown. The bottom of the logs each have two
holes that align with the pegs found on the burner.
Separate glowing embers
and place as shown here
(top view above front log)
Separate the remaining glowing embers into small
pieces and evenly place them along the front and
center burner ports as shown.
Separate bryte coals and
place as shown here
(top view above front log)
Separate the bryte coals into small pieces and
evenly place them above the front glowing embers
as shown.
DVCL-11Y
DVCL-11T
6
DVCL-9T
7
DVCL-13
8
DVCL-10
8
Charred Ancient Oak Log Placement Instructions (36" model) (Cont.)
Place the left top logs (logs #3 and #4) as shown.
The bottom logs have notches to aid in positioning
the top logs.
VI
VII
VIII
Place the right top logs (logs #5 and #6) as shown.
The logs below have notches to aid in positioning
the top logs.
Place the left and right top logs (logs #7 and #8) as
shown. The logs have notches to aid in positioning
the top logs.
4
3
6
5
8
7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Real Fyre DVI Owner's manual

Type
Owner's manual
This manual is also suitable for

Real Fyre DVI is an advanced gas log set that offers a realistic and convenient way to enjoy the ambiance of a wood-burning fireplace without the hassle and mess. With its simple installation and easy-to-use features, the Real Fyre DVI is a great choice for anyone looking to add warmth and beauty to their home.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI