Craftsman 580.675611 Owner's manual

Category
Power generators
Type
Owner's manual

This manual is also suitable for

Operator'sManual
®
ACGenerator
I;. wAemG
Before usingthis product, readthis
manualand follow all SafetyRules
and Operating Instructions.
_i._i]AVERTISSEMENT
Avant d'utiliser ceproduit, veuillez lire le
manuelet suivre toutes les directives
relatives_1la s6curit6et _1I'utilisation.
,, Safety
,, Assembly
,, Operation
,, Maintenance
,, Parts
,, Fran+ais,p. 36
Thisgeneratoris ratedandcertifiedto becompliantwithCSA(CanadianStandardsAssociation)standard022.2No.100-04(motorsand
generators).
Lescaract6ristiquesnominalesetla certificationdecetteg6n6ratricesontconformesAla normeC22.2No.100-04(moteursetg6n6ratrices)
deI'ACNOR(Associationcanadiennedenormalisation).
Sears Canada, Jnc.
Visit ourCraftsman wehsite:www.sears.ca
Part No. 201895GS Draft A (02/04/2008)
WARRANTY..................................... 2
SAFETYRULES................................. 3-5
FEATURESAND CONTROLS........................ 6
ASSEMBLY.................................... 7-9
OPERATION................................. 10-13
SPECIFICATIONS................................ 14
MAINTENANCE............................... 15-18
STORAGE...................................... 19
TROUBLESHOOTING............................. 20
NOTES........................................ 21
SCHEMATIC/WIRINGDIAGRAM.................. 22-23
REPLACEMENTPARTS......................... 24-33
EMISSIONSSYSTEMWARRANTY................ 34-35
FRAN_AIS................................... 36-59
HOWTOORDERPARTS................... BACKPAGE
OHE-YEARFULLWARRANTYOHCRAFTSMANGENERATOR
If this generator fails dueto a defectin material or workmanship within oneyear from the dateof purchase,return it to any
Searsstore, other Craftsmanoutlet, or Sears Parts & RepairCenter in the United Statesor Canadafor free repair (or
replacementif repair proves impossible).
Additional One-Year Limited Warranty on Craftsman Generator
Forthe second year from the dateof purchase,ifany part ofthis generator fails dueto a defect in material or workmanship, a
new part will be supplied free of charge. You must paythe labor cost ifyou wish to haveit installed.
All warranty coverageappliesfor only 90 days from date of purchase if this generator is ever usedfor commercial or rental
purposes.
This warranty gives you specific legal rights, and you may also haveother rights which vary from state to state.
Sears, Roebuck and Co., Hoffman Estates, IL 60179
Sears Canada Inc., Toronto, Ontario, Canada MSB 288
© SearsBrands, LLC
,_ Thisisthe safetyalert symbol,it isused to alert youtopotentialpersonalinjuryhazards.
Obeyall safetymessagesthatfollow this symbolto avoidpossibleinjuryordeath.
[ _-!] Read thismanual carefully and become familiar
...................withyourgenerator. Knowits applications,its
limitations,and any hazardsinvolved.
Thesafety alert symbol (_1_)is usedwith a signal word
(DANGER,CAUTION,WARNING),a pictorial and/or a safety
messageto alert you to hazards.DANGERindicatesa hazard
which, if not avoided, will result in deathor serious injury.
WARNINGindicatesa hazardwhich, if not avoided, could
result in deathor serious injury. CAUTIONindicatesa hazard
which, if not avoided, might result in minor or moderate
injury. NOTICEindicatesa situation that could result in
equipment damage.Follow safety messagesto avoid or
reducethe risk of injury or death.
WARHIHG
Theengine exhaustfrom thisproductcontains
chemicalsknowntothe State of California tocause
cancer,birthdefects, orotherreproductiveharm.
WARNING
This generatordoes not meetU. S.Coast Guard Regulation
330FR-183 and should not be usedon marine applications.
Failureto usethe appropriate U. S. CoastGuardapproved
generator could result in bodily injury and/or property damage.
Hazard Symbolsand Meanings
ToxicFumes
Fire
HazardousChemical Electrical Shock
Explosion Operator's Manual
Moving Parts FlyingObjects
Kickback HotSurface
DAHGER
Contentsare harmful or fatal if swallowed. Avoid
_ ontact to eyes, skin or clothing. DO NOT take
internally. Avoid breathing the mist or vapor.
Overexposure to eyes or skin can cause irritation.
Keep stabilizer out of the reach of children.
Fuel stabilizer is a hazardous chemical.**
o FreshStartTM fuel cap is designed to hold acartridge which
contains fuel stabilizer.
o If SWALLOWED,call physician immediately. DONOTinduce
vomiting. If inhaled, remove to fresh air. In case of eye or skin
contact, flush with water for 15 minutes.
* Store unopenedcartridges in a cool, dry, well ventilated area.
Keepopen cartridge in fuel cap, andfuel cap closed on fuel tank
when not in use.
o In the caseof an emergency,contact aphysician immediately
andcall 1-800-424-9380 for material safety information.
**Fuel stabilizer contains: 2,6-di-tret-butylphenol (128-39-2) and alipbatic petroleum
distillate (64742-47-8).
Using a generator indoors CAN KiLL YOU iN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smeJJ.
A
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents=
WARHIHG
Runningenginesgive off carbon monoxide, an
_ dorless,colorless, poison gas.
Breathingcarbon monoxide can cause headache,
Iatigue,dizziness,vomiting, confusion, seizures,
nausea_fainting or death.
* OperategeneratorONLYoutdoors.
* Installa batteryoperatedcarbonmonoxidealarmnearthe
bedrooms.
* Keepexhaustgasfrom enteringaconfinedareathrough
windows,doors,ventilationintakes,or otheropenings.
* DONOTstartor runengineindoorsor in anenclosedarea,
evenif windowsanddoorsareopen,includingthegenerator
compartmentof arecreationalvehicle(RV).
WARHIHG
Generator produces powerful voltage.
_.¢ Failure to isolate generator from power utility can
result in death or injury to electric utility workers
due to backfeed of electrical enerqy.
When using generator for backup power, notify utility company.
Use approvedtransfer equipment to isolate generator from
electric utility.
Use aground circuit fault interrupter (GFCI)in any damp or
highly conductive area, such as metal deckingor steelwork.
DO NOTtouch barewires or receptacles.
DO NOTusegenerator with electrical cords which areworn,
frayed, bare or otherwise damaged.
DO NOToperate generator in the rain or wet weather.
DO NOThandlegenerator or electrical cords while standing in
water, while barefoot, or while hands or feet arewet.
DO NOTallow unqualified persons or children to operate or
servicegenerator.
WARHIHG
Startercord kickback(rapid retraction) can result
in bodily injury. Kickbackwill pull handand arm
_,_< toward engine faster than you can let go.
Brokenbones, fractures, bruises, or sprains
could result.
When starting engine, pull cord slowly until resistanceis felt
andthen pull rapidly to avoid kickback.
NEVERstart or stop engine with electrical devices plugged in
andturned on.
WARNING
_,,_s Contact with muffler result in serious
area can
burns.
f'_ Exhaustheat/gases can ignite combustibles,structures or damagefuel tank causing a fire.
* DO NOTtouch hot parts andAVOID hot exhaust gases.
* Allow equipment to cool before touching.
. Keepat least 5feet (1.5 m) of clearanceon all sides of
generator including overhead.
. Codeof FederalRegulation (CFR)Title 36 Parks, Forests,and
Public Property require equipment powered by an internal
combustion engine to have aspark arrester, maintained in
effective working order, complying to USDAForestservice
standard 5100-1C or later revision. Inthe State of California a
spark arrester is requiredunder section 4442 of the California
Public resources code. Other statesmay havesimilar laws.
WARHIHG
_ Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHENADDINGORDRAININGFUEL
* Turn generator OFFand let it cool at least 2 minutes before
removing fuel cap. Loosencap slowly to relievepressure in
tank.
* Fill or drain fuel tank outdoors.
* DONOToverfill tank. Allow space for fuel expansion.
* Iffuel spills, wait until it evaporatesbefore starting engine.
* Keepfuel away from sparks, openflames, pilot lights, heat,and
other ignition sources.
* DONOTlight a cigarette or smoke.
WHENSTARTINGEQUIPMENT
* Ensure spark plug, muffler, fuel cap, andair cleaner arein
place.
* DO NOTcrank enginewith spark plug removed.
WHENOPERATINGEQUIPMENT
* DONOTtip engine or equipment at anglewhich causesfuel to
spill.
. DO NOTchoke carburetor to stop engine.
* This generator is notfor use in mobile equipment or marine
applications.
WHENTRANSPORTINGOR REPAIRINGEQUIPMENT
* Transport/repair with fuel tank EMPTYor with fuel shutoff valve
OFF.
. Disconnect spark plug wire.
WHENSTORINGFUELOR EQUIPMENTWITH FUELIN TANK
* Store away from furnaces, stoves,water heaters,clothes
dryers, or other appliancesthat have pilot light or other ignition
source becausethey can ignite fuel vapors.
WARHIHG
_ Unintentional sparking can result in fire or
electric shock.
WHENADJUSTINGORMAKING REPAIRSTO YOURGENERATOR
* Disconnectthe spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHENTESTINGFORENGINESPARK
* Use approved spark plug tester.
* DONOTcheck for sparkwith spark plug removed.
WARHIHG
Starter and other rotating parts canentanglehands, hair, clothing, or accessories.
* NEVERoperate generator without protective housing or covers.
* DO NOTwear loose clothing, jewelry or anything that may be
caught in the starter or other rotating parts.
* Tie up long hair and remove jewelry.
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy_load.
DONOTtamper with governed speed.Generator supplies
correct ratedfrequency andvoltage when running at governed
speed.
DO NOTmodify generator in anyway.
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
See Don't OverloadGenerator.
Start generator and let engine stabilize beforeconnecting
electrical loads.
Connectelectrical loads in OFFposition, then turn ONfor
operation.
Turn electrical loads OFFand disconnect from generator before
stopping generator.
NOTICE
Improper treatment of generator can damage it and shorten
its life.
Use generator only for intended uses.
Ifyou have questions about intended use, ask dealer or contact
Sears.
Operategeneratoronly on level surfaces.
DONOTexpose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DONOT insert any objects through cooling slots.
Ifconnected devices overheat, turn them off anddisconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
This equipment is designed to be used with Searsauthorized
parts ONLY.If equipment is used with parts that DO NOT
comply with minimum specifications, userassumes all risks
and liabilities.
KNOWYOUROEHERATOR
I!__-!i] Read the Operator'sManual and safety rulesbeforeoperating yourgenerator.
Comparethe illustrations with your generatorto familiarize yourself with the locations of various controls and
adjustments. Savethis manualfor future reference.
SparkArrester Muffler
\_. \ On/OffSwitch
FuelTank ,
Recoil Starter
Stat StationTM
120 Volt AC, 20 Amp
Duplex Receptacles
DataTag
Air Cleaner
Choke Lever
FuelValve
Oil FillCap
Double Pole Circuit
Breaker(AC)
Grounding Fastener
120/240 Volt AC,
30 Amp Receptacle
120 Volt AC,20 Amp, Duplex Receptacles -- May be used
to supply electrical power for the operation of 120 Volt AC,
20 Amp, single phase, 60 Hzelectrical, lighting, appliance,
tool and motor loads.
120/240 Volt AC,30 AmpLockingReceptacle -- May be
usedto supply electrical powerfor the operation of
120 and/or 240 Volt AC,30 Amp, single phase,60 Hz
electrical, lighting, appliance,tool and motor loads.
Air gleaner -- Protects engine by filtering dust and debris
out of intake air.
ChokeLever-- Usedwhen starting a cold engine.
Data Tag -- Provides model, revision and serial number of
generator. Pleasehavethese readily availablewhen calling
for assistance.
DoublePole Circuit Breaker (AC)-- A double pole circuit
breakeris provided to protect all the receptaclesand
generatoragainst electrical overload.
FuelTank-- Capacityof five (5) U.S.gallons.
FuelValve-- Usedto turn fuel supply onand off to engine.
GroundingFastener-- Consultyour local agency having
jurisdiction for grounding requirementsin your area.
Oil Fill Cap-- Checkand fill engine with oil here.Seepage
16 for oil recommendationsand filling instructions.
On/OffSwitch -- Setthis switch to "On"before using recoil
starter. Setswitch to "Off"to switch off engine.
Recoil Starter -- Usedto start the engine.
Spark ArrestorMuffler -- Exhaustmuffler lowers engine
noiseand is equipped with a spark arrester screen.
StatStationTM -- Displaysthe electrical load on generator
basedon output frequency. It also hasa built in maintenance
reminder.
Your Craftsmangenerator requiressome assembly and is
readyfor useonly after it has beenproperly serviced with the
recommendedoil and fuel.
If you haveany problemswith the assembly of your
generater, please call the generator helpline at
1-800-222-3136.
Unpacking the Generator
f. Setthe carton on a rigid fiat surface.
2. Removeeverything from carton except generator.
3. Opencarton compbtely by cutting eachcorner from top
to bottom.
4. Leavegeneratoron carton to installwheel kit.
Carton Contents
Checkall contents against those listed below:
* Main unit
* Engineoil
* Operator's manual
* Wheel kit
* Adapter cord set
If any parts are missing or damaged,call the generator
helpline at 1-800-222-3136.
install Wheel Kit
NOTE:Wheelkit is not intended for over-the-road use. DO
NOTtow this unit with a motorized vehicle.
You will needthe following tools to install these components:
* 13mm wrenches
* Socket wrench with a 13mm socket
* Pliers
Install theWheelKitasFellows:
IMPORTANT:Installing the wheel kit must be completed
prior to adding anyoil or fuel.
1. Tip generatorso that engine end is up.
2. Slide axlethrough both mounting brackets.
3. Placea wheel on eachside as shown in A.
4. Placea washer on axleand then placean e-ring in axle
groove.
5. Install e-ring with pliers, squeezingfrom top of e-ring to
bottom of axle.
CAUTION
E-rings cancause eyeinjury.
._j_ E-rings canspring back and become airborne
when installing or removing.
* Alwaysweareyeprotectionwheninstalling/removinge-rings.
6. Repeatstep 4 and 5 to securesecond wheel.
7. Tip generatorso that engine side is down.
8. Line up holes in support leg with holes in generator
frame.
9. Attachsupport leg using2 capscrews(Me x 16 mm) and
2 hexnuts.Tightenwith a 13mm socketwrench and
13mm wrench.
10. Return generatorto normal operating position (resting
on wheels and support leg).
*, Safetyglasses
FlatWasher
Capscrew
Axle
Wheel
J
E-Ring
BEFORESTARTINGTHEGENERATOR
Add Engine Oil
1. Placegeneratoron a flat, levelsurface.
2. Cleanarea around oil fill and remove yellow oil fill cap.
NOTE:Seethe section Oi/to review oil recommendations.
Verify provided oil bottle is correct viscosity for current
ambient temperature.
3. Using oil funnel (optional), slowly pour contents of
provided oil bottle intooil fill opening.
NOTICE
Improper treatment of generator can damageit and shorten
itslife.
DONOTattempttocrankor starttheenginebeforeit hasbeen
properlyservicedwith therecommendedoil.Thismayresultin
anenginefailure.
4. Replaceoil fill cap and fully tighten.
Add Fuel
Fuel mustmeetthese requirements:
* Clean,fresh, unleadedgasoline.
* A minimum of 87 octane/87 AKI (91 RON).Highaltitude
use,see HighAltitude.
* Gasolinewith up to 10% ethanol (gasohol) or up to 15%
MTBE(methyl tertiary butyl ether) is acceptable.
NOTICE
Avoid generatordamage.
Failureto follow Operator's Manualfor fuel
recommendations voids warranty.
DONOTuseunapprovedgasolinesuchasE85.
DONOTmixoil in gasoline.
DONOTmodifyengineto runon alternatefuels.
To protect the fuel system from gum formation, mix in a fuel
stabilizerwhen adding fuel. SeeStorage. All fuel is not the
same. If you experiencestarting or performanceproblems
after using fuel, switch to a different fuel provider or change
brands. This engine is certified to operateon gasoline. The
emission control system for this engine is EM(Engine
Modifications).
WARHIHG
Fueland its vapors are extremely flammable and
explosive.
Fireor explosion can causesevere burns or
death.
WHENADDINGFUEL
* TurngeneratorOFFandletit coolatleast2 minutesbefore
removingfuelcap.Loosencapslowlyto relievepressurein
tank.
* Fillfueltankoutdoors.
* DONOToverfilltank.Allowspaceforfuelexpansion.
* Iffuelspills,waituntilit evaporatesbeforestartingengine.
* Keepfuelawayfromsparks,openflames,pilotlights,heat,and
otherignitionsources.
* DONOTlighta cigaretteorsmoke.
1. Cleanareaaround fuel fill cap, removecap.
2. Slowly add regular unleadedfuel to fuel tank. Becareful
not to overfill. Allow at least 1.5" of tank spacefor fuel
expansion,as shown here.
3. Install fuel cap and wait for anyspilled fuelto evaporate.
CAUTION! Alcohol-blendedfuels (calledgasohol, ethanol or
methanol) canattract moisture, which leadsto separationand
formation of acids during storage.Acidic gas candamagethe
fuel system ofan engine while in storage.
To avoid engine performance issues,the fuel system should
betreated with a fuel preserver or emptied beforestorage of
30 days or longer. To protectthe fuel system from gum
formation, use Briggs & Stratton FRESHSTARTTM fuel
stabilizer plus, or FRESHSTARTTM continuous fuel preserver
(concentrated liquid cartridge). If fuel preserver is not used,
drain the fuel tank, start the engine and let it run until the fuel
linesand carburetor are empty. Usefresh fuel next season.
SeeStoragefor additional information.
NEVERuseengine or carburetor cleaner products in the fuel
tank as permanent damagemay occur.
FreshStaWMFuelCap
Adding fuel preserver helps keepfuel fresh and carburetors
cleanfor easierstarting, all season long. This newfuel cap
automatically drips concentrated fuel preserver into your fuel
tank.
DANGER
Contentsare harmful or fatal if swallowed. Avoid
contact to eyes,skin or clothing. DONOTtake
internally.Avoid breathingthe mist or vapor.
Overexposureto eyesor skin can causeirritation.
Keepstabilizerout of the reachof children.
Fuelstabilizer is a hazardouschemical.**
If SWALLOWED,callphysicianimmediately.
Inthecaseof anemergency,contacta physicianimmediately
andcall1-800-424-9300for materialsafetyinformation.
• *Fuel stabilizer contains: 2,6-di-tret-butylpbenol (128-39-2) and aliphatic petroleum
distillate (64742-47-8).
Placecartridge into fuel cap.
Y
2. Pushto "snap" cartridge into place.
3. Removetab to expose membrane.
IMPORTANT:DONOTremove the silver foil seal on the
opposite side of the cartridge.
4. Reinstallfuel cap on fueltank.
_--_._ //_
Periodically checkthe cartridge to ensurethere is still
fuel stabilizer inside. If it is empty, removecartridge and
replace.
HighAltitude
At altitudes over 5,000 feet (1524 meters), a minimum
85 octane / 85 AKI (89 RON)gasoline is acceptable.To
remainemissions compliant, high altitude adjustment is
required. Operationwithout this adjustment will cause
decreasedperformance, increasedfuel consumption, and
increasedemissions. Seea qualified Searsdealerfor high
altitude adjustment information. Operationof the engine at
altitudes below 2,500 feet (762 meters)with the high altitude
kit is not recommended.
HOWTO USEYOURGEHERATOR
If you haveany problems operatingyour generatorafter
readingthe manual, pleasecall the generator helpline at
1-800-222-3136.
System Ground
Thegenerator hasa system ground that connects the
generatorframe components to the ground terminals on the
ACoutput receptacles.Thesystem ground is connectedto
the ACneutral wire (the neutral is bonded to the generator
frame).
SpecialRequirements
Theremay be Federalor StateOccupationalSafetyand
HealthAdministration (OSHA)regulations, local codes, or
ordinancesthat applyto the intended useof the generator.
Pleaseconsult a qualified electrician, electrical inspector, or
the local agency havingjurisdiction.
Insome areas,generatorsare requiredto be registered
with local utility companies.
Ifthe generator is usedat a construction site, there may
be additional regulations which must be observed.
Connecting to a Building's Electrical System
Connectionsfor standby power to a buiiding's electrical
system must be madeby a qualified electrician. The
connection must isolate the generator power from utility
power, and must comply with all applicablelaws and
electricalcodes.
WARNING
Generatorproduces powerful voltage.
Failureto isolategeneratorfrom power utility can
result in death or injury to electric utility workers
due to backfeedof electrical energy.
Whenusinggeneratorfor backuppower,notifyutilitycompany.
Useapprovedtransferequipmentto isolategeneratorfrom
electricutility.
Useagroundcircuitfaultinterrupter(GFCI)in anydampor
highlyconductivearea,suchasmetaldeckingor steelwork.
DONOTtouchbarewiresor receptacles.
DONOTusegeneratorwithelectricalcordswhichareworn,
frayed,bareor otherwisedamaged.
. DONOToperategeneratorinthe rainor wetweather.
DONOThandlegeneratoror electricalcordswhilestandingin
water,whilebarefoot,orwhilehandsor feetarewet.
DONOTallowunqualifiedpersonsor childrento operateor
servicegenerator.
Generator Location
GeneraterClearance
WARNING
_ Exhaustheat/gases can ignite combustibles,
structures or damagefuel tank causing a fire.
Keepatleast5 ft. (1.5m)clearanceonall sidesofgenerator
includingoverhead.
Placegenerator outdoors in an areathat will not accumulate
deadlyexhaustgas. DONOTplacegenerator whereexhaust
gas could accumulate and enter inside or be drawn into a
potentially occupied building. Ensureexhaustgas is kept
away from anywindows, doors, ventilation intakes or other
openingsthat can allow exhaustgasto collect in a confined
area. Prevailingwinds and air currents should be taken into
consideration when positioning generator.
WARHIHG
Runningenginesgive off carbon monoxide, an
_ dorless,colorless, poison gas.
Breathingcarbon monoxide can cause headache,
fatigue,dizziness,vomiting, confusion, seizures,
nausea,fainting or death.
. OperategeneratorONLYoutdoors.
* Installa batteryoperatedcarbonmonoxidealarmnearthe
bedrooms.
* Keepexhaustgasfrom enteringaconfinedareathrough
windows,doors,ventilationintakes,or otheropenings.
. DONOTstartor runengineindoorsor in anenclosedarea,
evenif windowsanddoorsareopen,includingthegenerator
compartmentof arecreationalvehicle(RV).
Typical Generator Shown
L ExhaustPort
10
To Start The Engine
Disconnectall electrical loadsfrom the generator. NEVER
start or stop engine with electrical devicesplugged in and
turned ON. Follow start instruction steps in numerical order:
1. Make sure unit is on a levelsurface.
IMPORTANT:Failureto start and operateunit on a level
surfacewill cause the unit not to start or shut down during
operation.
2. Turn red fuel valveto "On" position.
3. Place choke lever in "Choke" position.
4. Set On/Offswitch to "On" position.
oo o,,sw,t h, howo
in On position _y
5. Grasprecoil handle and pull slowly until slight resistance
is felt. Thenpull rapidlyto start engine.
WARNING
Startercord kickback(rapid retraction) can result
in bodily injury. Kickbackwill pull handand arm
_,1_.< toward enginefaster than youcan let go.
Brokenbones, fractures, bruises, or sprains
could result.
, Whenstartingengine,pullcordslowlyuntilresistanceisfelt
andthenpull rapidlyto avoidkickback.
* NEVERstartor stopenginewithelectricaldevicespluggedin
andturnedon.
IMPORTANT:If enginefloods, placechoke leverin "Run"
position and crank until engine starts.
6. Move choke lever to "Run" position a short distanceat a
time over severalseconds in warm weather or minutes
in cold weather. Letengine run smoothly beforeeach
change. Operatewith choke in "Run" position.
NOTE:If engine starts after 3 pulls but fails to run, or if unit
shuts down during operation, makesure unit is on a level
surfaceand checkfor proper oil level in crankcase.This unit
may beequipped with a low oil protection device.If so, oil
must be at proper levelfor engineto start.
WARHIHG
_ ontact with muffler area can result in serious
burns.
_ Exhaustheat/gases can ignite combustibles,
structures or damagefuel tank causing a fire.
, DONOTtouchhotpartsandAVOIDhotexhaustgases.
Allowequipmenttocoolbeforetouching.
, Keepatleast5 feet(1.5m) ofclearanceonall sidesof
generatorincludingoverhead.
, Codeof FederalRegulation(CFR)Title36Parks,Forests,and
PublicPropertyrequireequipmentpoweredbyaninternal
combustionengineto haveasparkarrester,maintainedin
effectiveworkingorder,complyingto USDAForestservice
standard5100-1Cor laterrevision.IntheStateof Californiaa
sparkarresterisrequiredundersection4442oftheCalifornia
Publicresourcescode.Otherstatesmayhavesimilarlaws.
Connecting Electrical Loads
Letthe engine stabilize and warm up for a few minutes
after starting.
DONOTconnect240Voltloadsto 120Voltreceptacles.
DONOTconnect 3-phase loadsto the generator.
DONOTconnect 50 Hzloadsto the generator.
Plugin and turn on the desired 120 Volt AC, single phase,
60 Hertzelectrical loads.
DONOTOVERLOADTHEGENERATOR.SeeDon't
OverloadGenerator.
NOTICE
Exceedinggenerators wattage/amperagecapacity can
damagegeneratorand/or electricaldevicesconnectedto it.
SeeDon'tOverloadGenerator.
Startgeneratorandletenginestabilizebeforeconnecting
electricalloads.
Connectelectricalloadsin OFFposition,thenturnONfor
operation.
TurnelectricalloadsOFFanddisconnectfromgeneratorbefore
stoppinggenerator.
Stopping the Engine
1. Turn off and unplug all electrical loadsfrom unit. NEVER
start or stop engine with electrical devicesplugged in
and turned on.
2. Letengine run at no-load for two minutes to stabilize
unit's internal temperatures.
3. Move On/Offswitch to "Off" position.
4. Move fuel valveto "Off" position.
WARHIHG
Backfire,fire or engine damagecould occur.
DONOTstopenginebymovingchokeleverto "Choke"
position.
11
CORDSETSANDRECEPTACLES
Useonly high quality, well-insulated, grounded extension
cords with the generator's 120 Volt electrical receptacles.
Inspectextension cords before eachuse.
Checkthe ratings of all extensioncords beforeyou usethem.
Extensioncord sets usedshould be ratedfor 125Volt AC
loads at 20 Amps or greaterfor most electrical devices.
Some devices,however, may not require this type of
extensioncord. Checkthe operator's manualsof those
devicesfor the manufacturer's recommendations.
,_ WARHIHG
_ verloadedelectrical cords can overheat,arc, and
burn resulting in death,bodily injury,and/or
propertydamage.
* ONLYusecordsratedforyourloads.
, Followall safetieson electricalcords.
Keepextensioncords as short as possible, preferably less
than 15 feet long, to prevent voltage drop and possible
overheating of wires.
120/240 Volt AC, 30 Amp, Locking Receptacle
Usea NEMAL14-30 plug with this receptacle.Connecta
4-wire cord set ratedfor 250 Volt AOloadsat 30 Amps (or
greater). You can usethe same4-wire cord if you planto
run a 120 Volt load.
4-WireCordSet
J
120 Volt AC, 20 Amp, Duplex Receptacles
Eachduplex receptacleis protected against overload by a
double pole rocker switch circuit breaker.
Useeach receptacleto operate120 Volt AO,single-phase,
60 Hzelectrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Usecord sets that are ratedfor 125 Volt
AC loadsat 20 Amps (or greater). Inspect cord sets before
each use.
GEHERATORADAPTERCORDSET
Thegenerator comes with a 25' generatoradaptercord set
designedto provide two sets of 120 Volt, 20 Amp outlets
from one 120 Volt, 20 Amp duplex receptacle.
(Neutral)
Y (Hot) | X (Hot)
NEMAL14-30 /--7I-7 Ground(Green)
This receptaclepowers 120/240 Volt A6, 60 Hz,single phase
loads requiring up to 5,600 watts of power (5.6 kW) at
23.3 Amps for 240 Volts or two independent 120 Volt loads
at 23.3 Amps each. Theoutlet is protected by a double pole
rocker switch circuit breaker.
NOTICE
Receptaclesmay be marked with rating value greaterthan
_ienerator out_
NEVERattemptto poweradevicerequiringmoreamperage
thangeneratoror receptaclecansupply.
DONOToverloadthegenerator.SeeDon'tOverloadGenerator.
The maximum load on eachoutlet is 20 Amps. Themaximum
total load on both black wire outlets or white stripe wire outlets
is 20 Amps. If an extensioncord is usedwith adaptercord set,
besure extensioncord is ratedfor 125V at 20 Amps.
NOTE:Followall safety precautions when connecting any
extension cord or deviceto the generator.
12
DOH'TOVERLOADGENERATOR
Capacity
You must make sureyour generator cansupply enough rated
(running) and surge (starting) watts for the itemsyou will
power at the sametime. Followthese simple steps:
1. Selectthe itemsyou will power at the same time.
2. Total the rated(running) watts of these items.This isthe
amount of power your generator must produce to keep
your items running.
3. Estimate how manysurge (starting) watts you will need.
Surge wattageis the short burst of power neededto
start electric motor-driven tools or appliancessuch as a
circular saw or refrigerator. Becausenot all motors start
at the sametime, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total ratedwatts from step 2.
Rated (Running)
Watts
1200
Example:
800
500
500
75
3075 Total
Running Watts
Tool or Appliance
Window Air
Conditioner
Refrigerator 1600
DeepFreezer 500
Television
Light (75 Watts)
Total Rated(Running) Watts
HighestAdditional SurgeWatts
Total GeneratorOutput Required
AdditionalSurge
(Starting) Watts
1800
1800 Highest
Surge Watts
=3075
= 1800
=4875
NOTE:Therated (running) watts cannot exceed5600. Also,
giventhe 5600 watt rated limit, additional surge (starting)
watts cannot exceed8600.
Power Management
To prolong the life of your generator and attacheddevices, it
is important to take carewhen adding electrical loadsto your
generator. Thereshould be nothing connectedto the
generator outlets before starting it's engine.Thecorrect and
safe way to managegenerator power is to sequentiallyadd
loads asfollows:
1. With nothing connectedto the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferablythe largest
load you have.
3. Permit the generatoroutput to stabilize (engine runs
smoothly and attached deviceoperates properly).
4. Plug in and turn on the next load.
5. Again,permit the generatorto stabilize.
6. Repeatsteps 4 and 5 for eachadditional load.
NEVERadd more loadsthan the generator capacity.Take
special careto consider surge loads in generatorcapacity,as
describedabove.
Wattage ReferenceGuide
Rated* Additional
Tool or Appliance (Running) Surge
Watts (Starting)
Watts
Essentials
Light Bulb - 75 watt 75 --
DeepFreezer 500 500
Sump Pump 800 1200
Refrigerator/Freezer- 18 cf 800 1600
Water Well Pump - 1/3 hp 1000 2000
Heating/Cooling
Window AC- 10,000 BTU 1200 1800
Window Fan 300 600
FurnaceFanBlower - 1/2 hp 800 1300
Kitchen
Microwave Oven- 1000 Watt 1000 --
CoffeeMaker 1500 --
Electric Stove - Single Element 1500 --
Hot Plate 2500 --
Family Room
DVD/CDPlayer 100 --
VCR 100 --
Stereo Receiver 450 --
Color Television- 27 in 500 --
PersonalComputer w/17 in moni- 800 --
tor
Other
Security System 180 --
AM/FM Clock Radio 300 --
GarageDoor Opener- 1/2 hp 480 520
ElectricWater Heater- 40 gallon 4000 --
DIY/JohSite
Quartz HalogenWork Light 1000 --
Airless Sprayer- 1/3 hp 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 hp 1000 1000
Circular Saw - 7-1/4 in 1500 1500
Miter Saw- 10 in 1800 1800
TablePlaner- 6 in 1800 1800
TableSaw/RadialArm Saw- 10 in 2000 2000
Air Compressor - 1-1/2 hp 2500 2500
*Wattages listed are approximateonly. Checktool or
appliancefor actual wattage.
13
EHGINETECHNICALIHFORMATION
This isa single cylinder, overheadvaive(ORV),air cooled
engine, it isa low emissions engine.
Inthe Stateof California, ModelSeries 200000 enginesare
certified by the CaliforniaAir ResourcesBoardto meet
emissions standardsfor 250 hours. Suchcertification does
not grant the purchaser,owner or operator of this engine any
additional warranties with respectto the performance or
operational life of this engine.Theengine is warranted solely
according to the product and emissions warranties stated
elsewherein this manual.
Power Ratings
Thegross power rating for individual gas engine models is
labeledin accordancewith SAE(Societyof Automotive
Engineers)codeJ1940 (Small Engine Power & Torque
Rating Procedure),and rating performance hasbeen
obtained andcorrected in accordancewith SAEJ1995
(Revision2002-05). Torquevalues are derived at3060 RPM;
horsepower values are derivedat 3600 RPM.Actual gross
engine power will be lower and is affected by, among other
things, ambient operating conditions and engine-to-engine
variability. Givenboth the wide array of products on which
enginesare placedand the variety of environmental issues
applicableto operatingthe equipment, the gas engine will not
developthe ratedgross power when used in a given pieceof
power equipment (actual "on-site"or net power). This
difference is due to a variety of factors including, but not
limited to, accessories (air cleaner, exhaust,charging,
cooling, carburetor, fuel pump, etc.), application limitations,
ambient operating conditions (temperature,humidity,
altitude), and engine-to-engine variability. Dueto
manufacturing and capacity limitations, Briggs & Stratton
maysubstitute an engine of higher ratedpower for this
Seriesengine.
This generator is ratedand certified to be compliant with CSA
(CanadianStandards Association) standard C22.2 No. 100-04
(motors and generators).
PRODUCTSPECIFICATIOHS
Generator Specifications
StartingWattage.................... 8600 Watts(8.6 kW)
Wattage .......................... 5600 Watts(5.6 kW)
ACVoltage.............................. 120/240Volts
ACCurrent
at240 Volts ............................. 23.3Amps
at 120Volts ............................. 46.6Amps
Frequency .......................... 60 Hzat 3600rpm
Phase .................................. SinglePhase
FuelCapacity............................ 5 U.S.gallons
Engine Specifications
Bore ................................ 3.12in.(79 ram)
Stroke ............................... 2.44in.(62 ram)
Displacement ........................ 18.64in.(305 cc)
SparkPlug
Type: ............ Briggs& Stratton491055S or 5066D
SetGapTo: .................... 0.030 inch(0.76ram)
ArmatureAir Gap:.......... 0.008-0.012in. (0.20-0.30ram)
Valveclearancewithvalvespringsinstalledand piston1/4in.
(6 ram)pasttopdeadcenter(checkwhenengineiscold).
Intake ................... 0.004-0.006in. (0.10-0.15mm)
Exhaust.................. 0.004-0.006in. (0.10-0.15mm)
Oil Capacity .................... 28 Ounces(0.8 Liters)
NOTE:Forpractical operation, the generator load should not
exceed 85% of rated wattage. Enginepower will decrease
3-1/2% for each1,000 feet (300 meters) abovesea leveland
1% for each 10° F(5.6° C) above77° F(25° C). It should
operatesatisfactorily at an angle up to 15°.
14
MAINTENANCESCHEDULE
Followthe hourly or calendarintervals, whichever occurs
first. More frequent service is required when operating in
adverseconditions noted below.
* Changeengineoil
* Cleandebris
Checkengine oil level
Service engineair cleaner'
* Changeengineoil'
* Servicespark plug
* Servicespark arrestor
* Cleancooling systemr
* Checkvalveclearance
Service more often under dirty or dusty conditions.
General Becommendations
Regularmaintenancewill improve the performanceand
extendthe life of the generator. Seea Searsor other qualified
dealerfor service.
Thegenerator's warranty doesnot cover items that have
been subjectedto operator abuseor negligence.To receive
full valuefrom the warranty, the operator must maintain
generatoras instructed in this manual.
Someadjustments will needto be madeperiodically to
properly maintain your generator.
All serviceand adjustments should be madeat least once
eachseason.Follow the requirementsin the Maintenance
Schedulechart above.
NOTE:Oncea year you should clean or replacethe spark
plug and replacethe air filter. A new spark plug and clean air
filter assure proper fuel-air mixture and help your engine run
better and last longer.
EmissionsContrnl
Maintenance, replacement,or repair of the emissionscon-
trol devicesand systemsmay be performedby any non-
roadengine repair establishmentor individual. However,
to obtain "no charge" emissions control service, the work
must be performed by a factory authorized dealer.Seethe
Emissions Warranty.
GENERATORMAINTENANCE
Generatormaintenanceconsists of keepingthe unit cleanand
dry. Operateand store the unit in a clean dry environment
where it will not beexposedto excessivedust, dirt, moisture
or anycorrosive vapors. Coolingair slots in thegenerator
must not becomeclogged with snow, leaves,or any other
foreign material.
Checkthe cleanlinessof the generator frequently and clean
when dust, dirt, oil, moisture or other foreign substancesare
visible on its exterior surface.
NOTE:DONOTusea garden hoseto cleangenerator. Water
can enterthe engine fuel system and causeproblems. In
addition, if water enters the generatorthrough cooling air
slots, some of the water will be retainedin voids and cracks
of the rotor and stator winding insulation. Water and dirt
buildup on the generator internal windings will eventually
decreasethe insulation resistance of these windings.
Generator Cleaning
Daily or before use,clean accumulated debrisfrom
generator. Keeplinkage,spring and controls clean. Keeparea
around and behind muffler free from anycombustible debris.
Inspect cooling air slots and openings on the generator.
Theseopenings must be kept clean and unobstructed.
Generatorparts should be kept cleanto reducethe risk of
overheating and ignition of accumulated debris.
* Usea dampcloth to wipe exterior surfaces clean.
NOTICE
Improper treatment of generator can damageit and shorten
its life.
DONOTexposegeneratorto excessivemoisture,dust,dirt, or
corrosivevapors.
DONOTinsertanyobjectsthroughcoolingslots.
Usea soft bristle brush to loosencaked on dirt, oil, etc.
* Usea vacuumcleanerto pick uploosedirtand debris.
15
StatStatienTM
TheStatStationTM displaysthe nominal load on generator
basedon output frequency, it also has a built in maintenance
reminder.
WattageMonitor Operation
Thedisplay is two seven-segmentLEDsthat provide an easy-
to-read indication of the amount of power being supplied by
the generator. Theload monitor displays the generator's
output as a percentage.
As generatorload increases,the display values will increase.
Whenthe displayedvalues begin flashing, the user should
stop adding electrical loads to the generator.
If the power usagebecomestoo high, the letters "OL" (for
Over Load)will flash on the display. The usershould reduce
the amount of load attachedto the generator.
MaintenanceReminder
The LEDwill display certain codes to alert you to check oil,
changeoil, check or replaceair filter and checkor replace
spark plug. Thefollowing codes will display:
"C1" Checkoil at 8 hour increments
"C2" Changeoil at 50 hour increments
"C3" Checkor replaceair filter at 25 hour increments
"C4" Checkor replacespark plug at 100 hour increments
Totake advantage ofthe StatStation "maintenance reminder"
capabilities, the user must press the resetbutton after
completing the maintenancecalled for in the displayedcode
(Cl, C2, C3, or C4). This results in a display of "Co" or "CA",
depending on how long the button is pressed:
1) "Co" - Pressingthe resetbutton once quickly will display
"Co"(clearingto zero). This will clearany maintenance
codes that haveelapsedup to that point and they will
begin timing again from zero.
2) "CA" - Pressing and holding the reset button for
2 secondswill display "CA"(clearing all). This clears all
maintenancecodes,even if they havenot yet reached
their service point, and they will begin timing again from
ze ro.
If nominal load and maintenancecodes appear
simultaneously, the LEDshall display,alternately, the
nominal load and codeas follows:
Thecode will display for 3 seconds, then 1/2 second off. The
load will display for 6 seconds and then 1/2 second off.
ENGINEMAIHTENANCE
WARHIHG
f'_J Unintentionalsparking can result in fire or
electric shock.
WHENADJUSTINGORMAKINGREPAIRSTOYOURGENERATOR
* Disconnectthe sparkplugwirefromtile sparkplugandplace
thewirewhereit cannotcontactsparkplug.
WHENTESTINGFORENGINESPARK
* Useapprovedsparkplugtester.
* DONOTcheckfor sparkwith sparkplugremoved.
Oil
Oil Recommendations
We recommendthe use of Briggs & Stratton Warranty
Certifiedoils for best performance. Other high-quality
detergentoils are acceptableif classified for service SF,SG,
SH,SJ or higher. DONOTusespecial additives.
Outdoortemperatures determinethe proper oil viscosity for
the engine. Usethe chart to selectthe best viscosity for the
outdoor temperature range expected.
oF
104 m __
86 __
68 -- w --_
32
14
-4
-22
°C
2O
_ m 0
L--J L--2o
;--#X_/_---30
* Below40°F(4°C)theuseof SAE30will resultinhardstarting.
** Above80°F(27°0)theuseof 10W30maycauseincreasedoil
consumption.Checkoil levelmorefrequently.
_ OTE:Synthetic oil meeting ILSACGF-2,API
certification mark and APIserv,!cesymbol with
"SJ/CFENERGYCONSERVINGor higher, is an
acceptableoil atall temperatures. Use of synthetic oil
does not alter required oil changeintervals.
16
ChecldngOilLevel
Oil level should be checked prior to each useor at least every
8 hours of operation. Keepoil levelmaintained.
1. Make sure generatoris on a levelsurface.
2. Cleanarea around oil fill and remove oil fill cap.
3. Verify oil is at the point of overflowing at oil fill opening.
4. Replaceand tighten oil fill cap.
AddingEngineOil
1. Make sure generatoris on a levelsurface.
2. Checkoil levelas described in CheckingOil Level
3. If needed,slowly pour oil into oil fill opening to the point
of overflowing at oil fill.
4. Replaceand tighten oil fill cap.
Service Air Cleaner
Your enginewill not run properly and may be damagedif you
run it with a dirty air cleaner.
Replacethe air cleanerevery 25 hours of operation or once
eachyear, whichevercomes first. Replacemore often if
operating under dirty or dusty conditions.
Toservicetheair cleaner,feflew thesesteps:
1. Loosenscrews and removeair cleanercover. Remove
paper filter.
Cover
\
Cartridge
\
Sore!
Base
2. Install clean (or new) air cleanerassembly inside cover.
Disposeof old filter properly.
3. Assembleair cleanercover onto baseandtighten
screws.
NOTE:You can purchase newair cleanerelementsby calling
1-80O-4-NIY-HONIE(46g-4663).
Changing Engine Oil
Changethe oil after the first 5 hours of operation. Changeoil
every 50 hours thereafter, if you are using your generator
underextremely dirty or dusty conditions, or in extremely hot
weather,changethe oil more often.
CAUTION
Avoid prolonged or repeatedskin contact with used motor
oil.
Usedmotoroil hasbeenshownto causeskincancerincertain
laboratoryanimals.
Thoroughlywashexposedareaswith soapandwater.
KEEPOUTOFREACHOFCHILDREN.DON'T
POLLUTE.CONSERVERESOURCES.RETURN
USEDOILTOCOLLECTIONCENTERS.
Changethe oil while the engine is still warm from running, as
follows:
1. Makesure unit is on a levelsurface.
2. Disconnectthe spark plug wire from the spark plug and
placethe wire where it cannot contact spark plug.
3. Cleanareaaround oil drain plug.The oil drain plug is
locatedat baseof engine,opposite carburetor.
4. Removeoil drain plug and drain oil completely into a
suitable container.
5. Reinstalloil drain plug and tighten securely. Removeoil
fill cap.
6. Slowly pour recommendedoil (about 28 oz.) into oil fill
opening to the point of overflowing at oil fill cap.
7. Reinstalloil fill cap. Fingertighten capsecurely.
8. Wipe up anyspilled oil.
9. Reconnectspark plug wire to spark plug.
Clean/Replace Spark Plug
Changethe spark plug every 100 hours of operation or once
eachyear, whichever comes first. This will help your engine
to start easierand run better.
1. Cleanareaaround spark plug.
2. Removeand inspect spark plug.
3. Replacespark plug if electrodesare pitted, burned or
porcelainis cracked. Usea recommendedreplacement
plug.
4. Checkelectrode gap with wire feelergauge and set spark
plug gap to 0.030 inch (0.76ram) if necessary.
5. install spark plug and tighten firmly.
NOTE:You canpurchase a new spark plug bycalling
1-800-4-NIY-HONIE(46g-4663).
17
Clean Spark Arrester Screen
Theengine exhaust muffler hasa spark arrester screen.
Inspectand cleanthe screen every 100 hours of operation or
once eachyear, whichever comes first.
NOTE:You can purchasea newspark arrester screen by
calling 1-800-4-MY-HOME (46g-4663).
If you useyour generatoron any forest-covered, brush-
covered,or grass-coveredunimproved land, it must havea
spark arrester.Thespark arrester must be maintainedin good
condition bythe owner/operator.
WARHIHG
s_ Contact with muffler area can result in serious
burns.
._ Exhaustheat/gases can ignite combustibles,structures or damagefuel tank causing a fire.
. DO NOTtouch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
. Keepat least 5feet (152 cm) of clearanceon all sides of
generator including overhead.
Codeof FederalRegulation (CFR)Title 36 Parks, Forests,and
Public Property require equipment powered by an internal
combustion engine to have aspark arrester, maintained in
effective working order, complying to USDAForestservice
standard 5100-1C or later revision. Inthe State of California a
spark arrester is requiredunder section 4442 of the California
Public resources code. Other statesmay havesimilar laws.
Cleanand inspectthesparkattester asfollows:
1. To remove muffler heatshield from muffler, remove four
screws that connect guard to muffler bracket.
_. SparkArrester
'_ Screen
Muffler
HeatShield
Air Coofing System
Overtime debris may accumulate in cylinder cooling fins and
cannot be observed without partial engine disassembly. For
this reason,we recommendyou havea Searsor other
qualifiedservice dealercleanthe cooling system per
recommendedintervals (see MaintenanceSchedule).Equally
important is to keeptop of engine free from debris. See
GeneratorCleaning.
CLEAN
\
Check Valve Clearance
Regularvalveclearancecheck and adjustment will improve
performanceand extend engine life. This procedurecannot
be done without partial engine disassembly andthe use of
special tools. Forthis reasonwe recommend that you havea
Searsor other qualified service dealercheckand adjust valve
clearanceat recommendedintervals.
Carburetor Adjustment
Thecarburetor on this engine is low emission. It is equipped
with a non-adjustable idle mixture valve and governed idle, if
equipped. Governedidle and top speed havebeenset atthe
factory. If adjustment is required,seea Searsor other
ualifiedservice dealer.
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessivel lows eeds Bose a heavy load.
DONOTtamper with governed speed.Generator supplies
correct ratedfrequency andvoltage when running at governed
speed.
DO NOTmodify generator in anyway.
2. Removefour screws that attach spark arrester screen.
3. Inspect screen and replaceif torn, perforated or
otherwise damaged. DONOTusea defective screen. If
screen is not damaged,cleanit with commercial solvent.
4. Reattachscreen and muffler guard.
18
GENERAL
Thegenerator should be started at least once every seven
days and allowedto run at bast 30 minutes, if this cannot be
done and you must store the unit for morethan 30 days, use
the following information asa guide to prepare it for storage.
LongTerm Storage instructions
It is importantto prevent gum deposits from forming in
essentialfuel system parts, such asthe carburetor, fuel filter,
fuel hose or tank during storage. Also, a]cohoi-bbnded fuels
(calledgasoho],ethanol or methanol) can attract moisture,
which leadsto separation and formation of acids during
storage.Acidic fuel can damagethe fuel system of an engine
whib in storage.
Protect Fuel System
WARNING
_J Fueland its flammable and
vapors
are
extremely
explosive.
Fireor explosion can causesevere burns or
death.
WHENSTORINGFUELDREQUIPMENTWITHFUELIN TANK
* Storeawayfromfurnaces,stoves,waterheaters,clothesdryers
or otherappliancesthathavepilotlightor otherignitionsource
becausetheycanignitefuelvapors.
WHENDRAININGFUEL
, TurngeneratorOFFandletit coolatleast2 minutesbefore
removingfuelcap.Loosencapslowlyto relievepressurein
tank.
, Drainfueltankoutdoors.
* Keepfuelawayfromsparks,openflames,pilotlights,heat,and
otherignitionsources.
, DONOTlighta cigaretteor smoke.
FuelPreserver:
Fillthe fueltank with fresh fuel allowing at bast 1.5"of tank
spacefor fuel expansion as shown on page8, when using a
fuel preserver cartridge with the fresh start fuel cap. If only
partially filled, air in the tank will promote fuel deterioration
during storage. Engineand fuel canbe stored upto 6 months
with fuel preserver.
Checklevelof fuel preserver cartridge. Fuelpreserver is
dark in color.
Ifcartridge is almost empty or empty, replacewith a new
fuel preserver cartridge following the instructions in Fresh
StarY FuelCap.
If fuel preserver is not used, remove all fuel from tank and
run engine until it stops from lack of fuel.
ChangeOil
While engine isstill warm, drain oil from crankcase. Refill
with recommendedgrade. See ChangingEngine Oil.
Oil CylinderBore
Removespark plug and pour about 1 ounce (30ml) of
cleanengine oil into the cylinder.
Install spark plug and crank slowly to distribute oil.
WARHIHG
_'_ Unintentionalsparking can result in fire or
_,¢ electric shock.
* NEVERcrankenginewith sparkplugremoved.
generator
1. Cleangeneratoras outlined in GeneratorCleaning.
2. Checkthat cooling air slots and openings on generator
are openand unobstructed.
Other Storage Tips
1. DONOTstore fuel from one seasonto another unless it
hasbeentreated asdescribed in Protect FuelSystem.
2.
Replacefuel can if it starts to rust. Contaminatedfuel
will cause engine problems.
If possible, store unit indoors and cover it to give
protection from dust and dirt.
Coverunit with a suitable protective cover that does not
retain moisture.
WARHIHG
_ Storagecovers can be flammable.
* DONOTplacea storagecoveroverahotgenerator.
* Letequipmentcoolfora sufficienttime beforeplacingthe
coverontheequipment.
5. Storegenerator in clean, dry area.
19
Problem
Engineis running,hutno A€ output is
available.
Engine runs goodat no-load hut "hogs
down"when loadsare connected.
Cause
1. Circuit breakersis open.
2. Faultin generator.
3. Poor connection or defective cord
set.
4. Connecteddevice is bad.
1. Short circuit in a connectedload.
2. Enginespeedis too slow.
3. Generatoris overloaded.
4. Shorted generator circuit.
1. RockerSwitch set to "Off".
2. FuelValveis in "Off"position.
3. Dirty air cleaner.
4. Out of fuel.
5. Stalefuel.
6. Spark plug wire not connectedto
Cerreclien
1. Resetcircuit breaker.
2. Contact Searsor other qualified
service dealer.
3. Checkand repair.
4. Connectanother device that is in
good condition.
1. Disconnectshorted electrical load.
2. Contact Searsor other qualified
service dealer.
3. SeeDon't OverloadGenerator.
4. Contact Searsor other qualified
service dealer.
1. Setswitch to"On".
2. Turn fuel valveto "Open"position.
3. Cleanor replaceair cleaner.
4. Fillfuel tank.
5. Draingas tank and carburetor; fill
with fresh fuel.
6. Connectwire to spark plug.
Engine will not start;orstartsand runs
rough.
spark plug.
7. Badspark plug.
8. Water in fuel.
9. Flooded.
7. Replacespark plug.
8. Drainfuel tank and carburetor; fill
with fresh fuel.
9. Wait 5 minutes and re-crank engine.
Engine shutsdown when running.
Enginelacks power.
Engine"hunts" (speed constantly
fluctuates) or falters.
10. Excessivelyrich fuel mixture.
11. Intakevalve stuck open or closed.
12. Enginehaslost compression.
Out of fuel.
1. Loadis too high.
2. Dirty air filter.
Carburetor is running too rich or too
lean.
10. ContactSearsor other qualified
service dealer.
11. ContactSearsor other qualified
service dealer.
12. ContactSearsor other qualified
service dealer.
Fillfuel tank.
1. SeeDon't OverloadGenerator.
2. Replaceair filter.
ContactSears or other qualifiedservice
dealer.
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Craftsman 580.675611 Owner's manual

Category
Power generators
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages