To Start The Engine
Disconnectall electrical loadsfrom the generator. NEVER
start or stop engine with electrical devicesplugged in and
turned ON. Follow start instruction steps in numerical order:
1. Make sure unit is on a levelsurface.
IMPORTANT:Failureto start and operateunit on a level
surfacewill cause the unit not to start or shut down during
operation.
2. Turn red fuel valveto "On" position.
3. Place choke lever in "Choke" position.
4. Set On/Offswitch to "On" position.
oo o,,sw,t h, howo
in On position _y
5. Grasprecoil handle and pull slowly until slight resistance
is felt. Thenpull rapidlyto start engine.
WARNING
Startercord kickback(rapid retraction) can result
in bodily injury. Kickbackwill pull handand arm
_,1_.< toward enginefaster than youcan let go.
Brokenbones, fractures, bruises, or sprains
could result.
, Whenstartingengine,pullcordslowlyuntilresistanceisfelt
andthenpull rapidlyto avoidkickback.
* NEVERstartor stopenginewithelectricaldevicespluggedin
andturnedon.
IMPORTANT:If enginefloods, placechoke leverin "Run"
position and crank until engine starts.
6. Move choke lever to "Run" position a short distanceat a
time over severalseconds in warm weather or minutes
in cold weather. Letengine run smoothly beforeeach
change. Operatewith choke in "Run" position.
NOTE:If engine starts after 3 pulls but fails to run, or if unit
shuts down during operation, makesure unit is on a level
surfaceand checkfor proper oil level in crankcase.This unit
may beequipped with a low oil protection device.If so, oil
must be at proper levelfor engineto start.
WARHIHG
_ ontact with muffler area can result in serious
burns.
_ Exhaustheat/gases can ignite combustibles,
structures or damagefuel tank causing a fire.
, DONOTtouchhotpartsandAVOIDhotexhaustgases.
• Allowequipmenttocoolbeforetouching.
, Keepatleast5 feet(1.5m) ofclearanceonall sidesof
generatorincludingoverhead.
, Codeof FederalRegulation(CFR)Title36Parks,Forests,and
PublicPropertyrequireequipmentpoweredbyaninternal
combustionengineto haveasparkarrester,maintainedin
effectiveworkingorder,complyingto USDAForestservice
standard5100-1Cor laterrevision.IntheStateof Californiaa
sparkarresterisrequiredundersection4442oftheCalifornia
Publicresourcescode.Otherstatesmayhavesimilarlaws.
Connecting Electrical Loads
• Letthe engine stabilize and warm up for a few minutes
after starting.
• DONOTconnect240Voltloadsto 120Voltreceptacles.
• DONOTconnect 3-phase loadsto the generator.
• DONOTconnect 50 Hzloadsto the generator.
• Plugin and turn on the desired 120 Volt AC, single phase,
60 Hertzelectrical loads.
• DONOTOVERLOADTHEGENERATOR.SeeDon't
OverloadGenerator.
NOTICE
Exceedinggenerators wattage/amperagecapacity can
damagegeneratorand/or electricaldevicesconnectedto it.
SeeDon'tOverloadGenerator.
Startgeneratorandletenginestabilizebeforeconnecting
electricalloads.
Connectelectricalloadsin OFFposition,thenturnONfor
operation.
TurnelectricalloadsOFFanddisconnectfromgeneratorbefore
stoppinggenerator.
Stopping the Engine
1. Turn off and unplug all electrical loadsfrom unit. NEVER
start or stop engine with electrical devicesplugged in
and turned on.
2. Letengine run at no-load for two minutes to stabilize
unit's internal temperatures.
3. Move On/Offswitch to "Off" position.
4. Move fuel valveto "Off" position.
WARHIHG
Backfire,fire or engine damagecould occur.
DONOTstopenginebymovingchokeleverto "Choke"
position.
11