Renkforce Network extender Coax Range (max.): 1500 m 100 Mbps Owner's manual

Type
Owner's manual
Intended use
The product is used to establish a network connection via a coaxial cable. Hence, an already
existing coaxial cable can be used for the operation of a network or of corresponding network
devices without having to lay a new cable.
The transceiver supports PoE. A suitable power adapter is not included and must be purchased
separately.
The safety instructions must be observed at all times!
Any use other than that described above could lead to damage to this product and involves
the risk of short circuits, re, electric shock, etc. No part of the product may be modied or
converted!
This product complies with the applicable national and European requirements. All names of
companies and products are the trademarks of the respective owners. All rights reserved.
Contents
1x transceivers
1x BNC-T adapter
Quick guide
Manufacturer’s operating instructions in English
Safety Instructions
The warranty will be void in the event of damage caused by failure to observe
these safety instructions! We do not assume any liability for any resulting
damage!
We shall not accept liability for damage to property or personal injury caused
by incorrect handling or non-compliance with the safety instructions! The
warranty will be void in such cases!
Unauthorised conversion and/or modication of the product is not allowed for
safety and approval reasons (CE).
The product is not a toy and should be kept out of the reach of children!
Do not leave packaging material carelessly lying around, since it could become a
dangerous plaything for children.
If you have any questions that are not answered in this manual, please contact our
technical service or another specialist.
Connection
The manufacturer’s operating instructions contain an illustration of a possible connection be-
tween the transceivers, two end devices and the network.
One of the transceivers must be connected to the existing network using a 1:1 wired network
cable (e.g. with a switch or router).
Furthermore, a suitable power adapter has to be connected to the transceiver which provides
the voltage/power for PoE (48 V/DC, output power depends on the devices connected).
The other transceivers must be connected to the terminal devices via RJ45 connector such as
a network camera, an access point, etc. If you use PoE-compatible end devices, the transceiv-
ers will provide the required power for the operation of these devices.
Connect the transceivers using the coaxial cable. For the operation of two end devices a BNC-
T adapter piece is enclosed in the package. In this case, you will need additional BNC cables
to connect the transceivers to the BNC-T adapter piece. These are available as accessories.
In this way, you can operate a total of up to four end devices (for each end device
one transceiver is required).
The arrangement of the BNC-T adaptor piece is insignicant. However, open ends
or branches are not permitted! Please also avoid terminations.
During start-up, the transceivers recognise each other. Hence, a conguration is not required.
For specic applications the transceivers can be “joined” with one another or “un-joined”. For
more information please refer to the manufacturers English operating instructions.
Example for 2 end devices:
Example for one end device:
A = End device 1
B = End device 2
C = Connection to switch/router
D = External power adapter (48 V/DC, output dependent upon the connected devices)
An “end device” is e.g. an IP camera, an access point, another switch or a VoiP
telephone.
The power LED lights up if there is voltage/power supply via a power adapter. The BNC LED
lights up if there is a data connection via the BNC cable. The PoE LED lights up with an existing
PoE connection.
For a permanent installation of the transceiver, the housing provides the corresponding open-
ings. However, you can also use double-sided adhesive tape or cable ties for the attachment.
Disposal
Electrical and electronic devices should not be disposed of in the household waste.
Dispose of an unserviceable product in accordance with the relevant statutory regu-
lations.
Technical data
Network ................................ 10/100Base T, half/full-duplex, IEEE802.3 af/at
Connection ........................... RJ45 or BNC (RG-59/U or similar)
Impedance ............................ 50 bis 100 Ω
Frequency band .................... 1.8 to 30 MHz
BNC cable length ................. Max. up to 1500 m (depending on the quality of the BNC cable/
plug used)
Operating voltage ................. 48 V/DC (via an external power adapter)
Power consumption .............. Approx. 2.5 W
Operating temperature ......... -10 to +50 °C
Operating air humidity .......... 0% to 90% relative air humidity, non-condensing
Dimensions ........................... 42 x 40 x 102.5 mm (W x H x D)
G
O P E R AT I N G I N S T R U C T I O N S www.conrad.com
Network extension
via coaxial cable
Item no. 800914
Version 10/14
A
B
C
D
A
C
D
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
(www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. This publication represent the technical status at the time of
printing.
© Copyright 2014 by Conrad Electronic SE.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Renkforce Network extender Coax Range (max.): 1500 m 100 Mbps Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI