DUCTLESS CONVERSION KIT
INSTALLATION
GUIDE
TABLE OF CONTENTS
Safety Instructions.................................................... 1
Specifications...........................................................2
Installation............................................................... 3
Part No. HRECUXT30/36 ©2003 Maytag Appliances Sales Co. Litho U.S.A.
Model Number: HRECUXT30
HRECUXT36
Size: 30” & 36”
INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODELS: HRECUXT30 HRECUXT36
Installation
The installation in this manual is intended for qualified installers, service technicians or persons
with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could
result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded.
Ductless Conversion
Ductless conversion is intended for applications where an exhaust duct work is not possible to
be installed. When converted, the hood functions as a "purifying" hood rather than an exhaust
hood. Fumes and exhaust from cooking are drawn and filtered by a set of Carbon Filters. The
air is then purified and re-circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing
new duct work, if possible. The hood is most effective and efficient as an exhaust unit. Only
when the exhaust option is not possible should you recourse to converting the hood into a
"purifying"unit.
When converted to be a "purifying" unit, Carbon Filters are required. Carbon Filters purify
fumes exhausted from cooking for re-circulation.
* Please check for latest specification revisions before any custom work or cutouts.
IMPORTANT SAFETY NOTICE
WARNING
INSTALLATION
2
SPECIFICATIONS
1"
2 1/2"
2 5/8"
1/2" Elec. K.O.
4 1/4" (30" hood)
7 1/4" (36" hood)
1"
2"
12"
30" or 36"
INSTALLATION
3
MOUNTING THE DUCTLESS CONVERSION HOUSING
1. The ductless conversion housing is
mounted under a kitchen cabinet unit
2. Begin installation by installing wood
blocking under cabinet as required.
3. Temporarily position the ductless
conversion housing in the desired
mounting location. Measure and mark
the mounting holes, and electrical
access locations with a pencil.
4. Drill out the required openings for
electrical access.
5. Fasten mounting screws into the
cabinet wood blocking as marked.
do not completely tighten the screws,
leaving half of the length exposed.
6. Rout electrical cable through knock out
opening.
7. Hang the ductless conversion housing
onto screws through key holes and tighten.
8. Temporary remove the diffuser panels from
the range hood.
9. Connect the electrical cable to the range
hood and screw the hood onto the ductless
conversion housing.
10. Position the carbon filters onto the diffuser
panels, and attach with rectangular washer
and screw as shown.
11. Re-install the diffuser panels.
12. Carbon filters must be replaced after
every 120 hours of use (or approximately
every 2-3 months based on the average
of 1-2 hrs. OK daily cooking time).
  • Page 1 1