VPC-6

Active Ventilation VPC-6, VPC-6-BL, VPC-6-WT User manual

  • Hello, I'm your chat assistant. I've reviewed the installation instructions for the Active Ventilation Products VPC-6 vent pipe cap. This document outlines the installation process and specifies the required hardware for proper installation. I'm ready to answer any questions you might have.
  • What is the recommended screw size?
    Are screws included?
    How many screws are needed?
3 1/8"
[7.94 cm]
6 1/4"
[15.75 cm]
5"
[12.76 cm]
1 1/4"
[3.05 cm]
9 1/4"
[23.49 cm]
Flashing Detail & Instructions
Active Ventilation Products, Inc.
Website: roofvents.com Email: [email protected]
Installation Instructions
Vent Pipe Cap Model: VPC-6 Diameter: 6"
3/24/2022
Exhaust Pipe
FastenerFastener
1. Slide the Vent Pipe Cap over the existing pipe.
2. Observe the screws located on top of the vent. Use this
as a pattern to attach the vent to the pipe.
3. To secure the vent, attach the vent to the pipe using a
#8 self-tapping sheet metal screw.
4. Total number of screws needed = 3
5. Recommended installation screw:
#8 x 1/2" Sheet Metal Screw
6. Screws not included.
* All Aluminum Construction, Thickness = 0.025" [0.635 mm]
/