Continal WCEXRF User guide

Type
User guide

Continal WCEXRF is a Quantum wiring extension-RF that increases the capabilities of your Quantum wiring center-RF. It allows you to attach up to 4 more thermostats, using simple push-in connectors. The device is easy to install and operate, with clear LEDs to keep you informed of its status. The extension-RF can be paired with the Quantum coordinator button, and it supports up to four actuators per zone. It complies with EU regulations for EMC, Low Voltage Directive, and RoHS.

Continal WCEXRF is a Quantum wiring extension-RF that increases the capabilities of your Quantum wiring center-RF. It allows you to attach up to 4 more thermostats, using simple push-in connectors. The device is easy to install and operate, with clear LEDs to keep you informed of its status. The extension-RF can be paired with the Quantum coordinator button, and it supports up to four actuators per zone. It complies with EU regulations for EMC, Low Voltage Directive, and RoHS.

UNDERFLOOR HEATING
Quantum wiring
extension-RF
Contents
1. Wiring diagram
2. Pairing thermostats with the Quantum wiring extension-RF
3. Installation
4. LED indications
5. Product compliance and safety information
Simple to operate and easy to install, our Quantum wiring extension-RF increases
the capabilities of your Quantum wiring centre-RF.
This plug-in unit allows you to attach up to 4 more thermostats, using simple push-
in connectors. Super-clear LEDs keep you in the picture.
UNDERFLOOR HEATING
1. Wiring diagram
2. Pairing thermostats with the Quantum wiring
extension-RF
Pairing thermostats should be done using the Quantum wiring centre-RF where the Quantum
coordinator is connected.
If you connect the Quantum wiring extension-RF to the Quantum wiring centre-RF on rst
installation, all of the thermostats on both the wiring centres will be automatically paired.
If you connect the Quantum wiring extension-RF to the Quantum wiring centre-RF after the
thermostats have been paired, you must pair thermostats with the Quantum wiring extension-RF.
To do this:
1. Turn o the power to the Quantum wiring centre-RF
2. Connect the Quantum wiring extension-RF to the Quantum wiring centre-RF
3. Power on the Quantum wiring centre-RF and the Quantum wiring extension-RF
4. Remove the front cover of the Quantum wiring centre-RF and press and hold the coordinator
button for ve seconds
5. Pair the thermostats in zones 9 to 12
6. Press and hold the Quantum coordinator button again for ve seconds
7. Replace the front cover of the Quantum wiring centre-RF
GROUP 2
GROUP 2
THERMOSTAT
(VS20WRF)
GROUP 2
THERMOSTAT
(VS20WRF)
GROUP 2
THERMOSTAT
(VS10WRF)
GROUP 2
THERMOSTAT
(VS10WRF)
SUPPLIED CABLES
UNDERFLOOR HEATING MANIFOLD
NL
UNDERFLOOR HEATING
Device
Power
50mm
110mm
10mm
10mm
3. Installation
Remove the white terminal connection board.Remove the plastic cover. Open the four
white screws with a quarter turn only.
Attach the back of the Quantum wiring
extension-RF
to the DIN rail or wall. If you
are tting to the side, use the short ribbon
cable. Otherwise, use the long ribbon cable
(see step 10). The following shows the
side-mounted, wall installation:
Cut the power and device cables to length.
Device
Power
50mm
110mm
10mm
10mm
1 2
3 4
Replace the white connection board. Insert the power wires.
56
Attach the white strain-relief using the
two screws to secure the power wires.
Push the actuator wires into the holes at the
bottom of the wiring extension-RF. You can
connect up to four actuators in each zone.
78
UNDERFLOOR HEATING
Attach the short ribbon cable between the
Quantum wiring centre-RF and the Quantum
wiring extension-RF for side installation,
otherwise use the long ribbon cable.
Remove the plastic cover from the Quantum
wiring centre-RF.
Push out the cut out on the bottom of the
cover of the Quantum wiring extension-RF.
Replace the plastic cover.
Switch on the mains power supply to the unit.
The red LED comes on.
910
11 12
13
UNDERFLOOR HEATING
5. Product compliance and safety information
Product compliance
This product complies with the essential requirements and other relevant provisions of the
following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU and RoHS
directive 2011/65/EU.
Safety information
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry
conditions. Installation must be carried out by a qualied person in accordance with national and
EU regulations.
Before attempting to setup and install, make sure that the devices are not connected to any power
source. Installation must be carried out by a qualied person. Incorrect installation may cause
damage to the devices. The Quantum wiring extension-RF should not be installed in areas where it
may be exposed to water or damp conditions.
4. LED indications
Name Colour Meaning
Connection Quantum wiring extension-RF is connected to the Quantum
wiring centre-RF
Power Quantum wiring extension-RF is supplied with 230VAC power
Zone 9 actuators Demand from zone 9 thermostat, actuator open
Zone 10 actuators Demand from zone 10 thermostat, actuator open
Zone 11 actuators Demand from zone 11 thermostat, actuator open
Zone 12 actuators Demand from zone 12 thermostat, actuator open
Want more information?
022 508 38 82
www.continal.ch
Rev:07/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Continal WCEXRF User guide

Type
User guide

Continal WCEXRF is a Quantum wiring extension-RF that increases the capabilities of your Quantum wiring center-RF. It allows you to attach up to 4 more thermostats, using simple push-in connectors. The device is easy to install and operate, with clear LEDs to keep you informed of its status. The extension-RF can be paired with the Quantum coordinator button, and it supports up to four actuators per zone. It complies with EU regulations for EMC, Low Voltage Directive, and RoHS.