National Instruments MON-10467 User manual

Type
User manual
USER GUIDE
MON-10467
12-Channel Wireless Vibration Measurement Device
MON-10467
This document explains how to install the MON-10467. You can use the MON-10467 to
wirelessly connect up to 12 sensors, such as piezoelectric accelerometers, proximity probes,
tachometers, voltage, and temperature, to your network without conduit for power or network
lines. This device is available in lithium battery, 24 V DC, and 120/220 V AC variants to
support your application’s requirements. Rated for outdoor use, the MON-10467 has a rugged
enclosure and a built-in mounting flange. With a five second data buffer per channel and full
waveform transmission, this device is ideal for applications that require wireless monitoring.
Note Read the MON-10467 Safety, Environmental, and Regulatory Information
document on ni.com/manuals before installing.
Note In this document, the MON-10467 (AC), MON-10467 (DC), and
MON-10467 (BATTERY) are referred to inclusively as the MON-10467. The
information in this document applies to all versions of the MON-10467 unless
otherwise specified.
Note The guidelines in this document are specific to the MON-10467. The other
components in the system might not meet the same safety ratings. Refer to the
documentation for each component in the system to determine the safety and EMC
ratings for the entire system.
Contents
Related Documentation.............................................................................................................3
Unpacking................................................................................................................................. 3
Kit Contents.............................................................................................................................. 3
What You Need to Get Started..................................................................................................4
Safety........................................................................................................................................ 5
Electromagnetic Compatibility Notices.................................................................................... 7
Parts Diagrams.......................................................................................................................... 8
MON-10467 with Door Closed.........................................................................................8
MON-10467 (AC) Parts Diagram.....................................................................................9
MON-10467 (DC) Parts Diagram...................................................................................10
MON-10467 (BATTERY) Parts Diagram.......................................................................11
Pinouts.....................................................................................................................................11
Analog Input Pinout........................................................................................................ 11
24 V DC Power Bus Terminals Pinout........................................................................... 12
Opening and Closing the Door................................................................................................13
Mounting.................................................................................................................................13
Installing the Antenna and Boot..............................................................................................14
Proximity Probe Drivers and Electronic Accessories............................................................. 15
Wiring......................................................................................................................................18
Wiring Guidelines........................................................................................................... 18
Using the Desiccant Kit.......................................................................................................... 26
MON-10401 Replacement Battery Pack for the MON-10467 (BATTERY)..........................28
Safety.............................................................................................................................. 28
Replacing the Battery Pack............................................................................................. 28
Battery Pack Recycling...................................................................................................29
Using the Reset Button........................................................................................................... 30
Where to Go Next................................................................................................................... 32
Product Certifications and Declarations................................................................................. 32
Worldwide Support and Services............................................................................................ 32
2 | ni.com | MON-10467 User Guide
Related Documentation
The following documents contain information about the MON-10467. To view them, go to
ni.com/manuals.
MON-10467 Safety, Environmental, and Regulatory Information
MON-10467 Specifications
For help using your device in InsightCM, refer to the InsightCM Help in software or online at
ni.com/r/insightcmhelp.
Unpacking
Notice Electrostatic Discharge (ESD) can damage the device. To prevent damage,
use industry-standard ESD prevention measures during unpacking, installation,
maintenance, and operation.
Notice Never touch exposed signal terminals, power terminals, or antenna
connector.
Remove the device from the package and inspect it for loose components or any other signs of
damage. Notify NI if the device appears damaged in any way. Do not install a damaged
device.
Kit Contents
MON-10467 (AC) and MON-10467 (DC) Kit Contents
3
1 2 4 5 6
1. MON-10467
2. MON-10467 Safety, Environmental, and
Regulatory Information
3. NI Monitoring Devices Card
4. 1 Antenna with weather-protective boot
5. 12 M16 Glands
6. 1 PG16 Gland
MON-10467 User Guide | © National Instruments | 3
MON-10467 (BATTERY) Kit Contents
3
1 2 4 5 6
1. MON-10467
2. MON-10467 Safety, Environmental, and
Regulatory Information
3. NI Monitoring Devices Card
4. 1 Antenna with weather-protective boot
5. 12 M16 Glands
6. 1 M16 Gland
What You Need to Get Started
MON-10467 (AC)
Hardware needed:
M6 to M8 bolts and nuts or 1/4 in. to 5/16 in. bolts and nuts
Washers (recommended)
M16 glands (supplied by NI)
Plugs rated for Type 3 or greater ingress protection for unused ports
PG16 gland (supplied by NI) or 0.5 in. conduit fitting
Power cable with a smooth, round jacket and individual conductors up to 12 AWG that
comply with your local electrical code
Tools needed:
2.5 mm flat-blade screwdriver (your own or NI part number 786911-01)
19 mm deep socket or wrench
22 mm socket or wrench
27 mm deep socket
30 mm socket or wrench
24 mm socket or wrench
(Optional) multi-prong actuation tool (WAGO part number 279-433)
(Optional) 19 mm gland dome nut tightening tool (SEALCON part number S-1900-WR)
(Optional) 24 mm gland dome nut tightening tool (SEALCON part number S-2400-WR)
4 | ni.com | MON-10467 User Guide
MON-10467 (DC)
Hardware needed:
M6 to M8 bolts and nuts or 1/4 in. to 5/16 in. bolts and nuts
Washers (recommended)
M16 glands (supplied by NI)
Plugs rated for Type 3 or greater ingress protection for unused ports
PG16 gland (supplied by NI) or 0.5 in. conduit fitting
Power cable with a smooth, round jacket and individual conductors up to 14 AWG that
comply with your local electrical code
Tools needed:
2.5 mm flat-blade screwdriver (your own or NI part number 786911-01)
#2 Phillips screwdriver
19 mm deep socket or wrench
22 mm socket or wrench
27 mm deep socket
30 mm socket or wrench
24 mm socket or wrench
(Optional) multi-prong actuation tool (WAGO part number 279-433)
(Optional) 19 mm gland dome nut tightening tool (SEALCON part number S-1900-WR)
(Optional) 24 mm gland dome nut tightening tool (SEALCON part number S-2400-WR)
MON-10467 (BATTERY)
Hardware needed:
M6 to M8 bolts and nuts or 1/4 in. to 5/16 in. bolts and nuts
Washers (recommended)
M16 glands (supplied by NI)
Plugs rated for Type 3 or greater ingress protection for unused ports
Chassis ground cable with a smooth, round jacket and spade or ring lug
Tools needed:
2.5 mm flat-blade screwdriver (your own or NI part number 786911-01)
#2 Phillips screwdriver
19 mm deep socket or wrench
22 mm socket or wrench
(Optional) multi-prong actuation tool (WAGO part number 279-433)
(Optional) 19 mm gland dome nut tightening tool (SEALCON part number S-1900-WR)
Safety
MON-10467 User Guide | © National Instruments | 5
Caution Observe all instructions and cautions in the user documentation. Using
the model in a manner not specified can damage the model and compromise the
built-in safety protection. Return damaged models to NI for repair.
Attention Suivez toutes les instructions et respectez toutes les mises en garde de la
documentation utilisateur. L'utilisation d'un modèle de toute autre façon que celle
spécifiée risque de l'endommager et de compromettre la protection de sécurité
intégrée. Renvoyez les modèles endommagés à NI pour réparation.
Caution The protection provided by the MON-10467 can be impaired if it is used
in a manner not described in the user documentation.
Attention La protection apportée par le MON-10467 risque d'être endommagée s'il
est utilisé d'une autre façon que celle décrite dans la documentation utilisateur.
Caution All wiring must be insulated for the highest voltage used.
Attention Tout le câblage doit être isolé pour la plus haute tension utilisée.
Caution An external circuit breaker box must be installed according to applicable
electrical codes by trained personnel to serve as the power disconnect when
installing the MON-10467 (AC). The circuit breaker box must be easy to reach and
marked as the power disconnect for the device.
Attention Un boîtier de disjoncteur externe doit être installé par du personnel
qualifié, conformément aux normes électriques en vigueur, afin de servir de
dispositif de coupure de courant lors de l'installation du MON-10467 (AC). Le
boîtier du disjoncteur doit être facilement accessible et marqué en tant que dispositif
de coupure de courant pour l'appareil.
Caution Disconnect external power to the MON-10467 (AC) and use the external
circuit breaker box to completely remove mains power before opening the device for
service.
Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le
boîtier de disjoncteur externe pour couper complètement l'alimentation secteur avant
d'ouvrir l'appareil pour l'entretien.
Caution Remove power to the MON-10467 (DC) before opening it for service.
Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour
l'entretien.
Caution Conduit or gland fittings must be installed by trained personnel according
to applicable electrical standards and the torque specified by the manufacturer.
6 | ni.com | MON-10467 User Guide
Attention Les raccords de conduits ou presse-étoupe doivent être installés par du
personnel qualifié conformément aux normes électriques applicables et au couple
spécifié par le fabricant.
Electromagnetic Compatibility Notices
Refer to the following notices for cables, accessories, and prevention measures necessary to
ensure the specified EMC performance.
Notice For EMC declarations and certifications, and additional information, refer
to the Product Certifications and Declarations section.
Notice The length of the signal cable must be no longer than 30 m (100 ft).
Notice Operate this product only with shielded cables and accessories.
Notice The performance of this product can be disrupted if subjected to
Electrostatic Discharge (ESD) during operation. To prevent damage, industry-
standard ESD prevention measures must be employed during installation,
maintenance, and operation.
MON-10467 User Guide | © National Instruments | 7
Parts Diagrams
MON-10467 with Door Closed
MON-10467
1
2
3
3
3
3
2
4
5
1. Antenna
2. Mounting flanges
3. Captive screws
4. Glands
5. Door
8 | ni.com | MON-10467 User Guide
MON-10467 (AC) Parts Diagram
3
5
2
1
4
1. 24 V DC power bus terminals
2. Reset button
3. Analog input terminals
4. AC power input terminals
5. Door pocket for desiccant pack
MON-10467 User Guide | © National Instruments | 9
MON-10467 (DC) Parts Diagram
1
2
3
6
5
4
1. 24 V DC power bus terminals
2. Reset button
3. Analog input terminals
4. Chassis ground screw
5. Ground shelf
6. Door pocket for desiccant pack
10 | ni.com | MON-10467 User Guide
MON-10467 (BATTERY) Parts Diagram
4
7
2
1
3
5
6
1. Battery
2. Battery power connector port
3. Reset button
4. Analog input terminals
5. Chassis ground screw
6. Ground shelf
7. Door pocket for desiccant pack
Pinouts
Analog Input Pinout
AI0+
AI0–
AI4+
AI4–
AI8+
AI8–
AI1+
AI1–
AI5+
AI5–
AI9+
AI9–
AI2+
AI2–
AI6+
AI6–
AI10+
AI10–
AI3+
AI3–
AI7+
AI7–
AI11+
AI11–
MON-10467 User Guide | © National Instruments | 11
Table 1. Signal Descriptions
Terminal Signal Description
0...11 AI+ Positive input of the analog input channel
0...11 AI- Negative input of the analog input channel
0...11 Chassis ground
You can connect ground-referenced or floating signal sources to the MON-10467. Each analog
input channel has a 3-pin connector to which you can connect a signal source. The AI+
terminal accepts the positive input signal and provides the IEPE excitation when enabled. The
AI- terminal provides the excitation return path and connects to the AI ground reference. The
chassis ground terminal provides a direct connection to the MON-10467 enclosure to which
the input signal cable shield or drain wire can be connected.
Notice Refer to the MON-10467 Specifications on ni.com/manuals to ensure that
the devices you connect to the MON-10467 are compatible with the device
specifications.
24 V DC Power Bus Terminals Pinout
Note MON-10467 (AC) and MON-10467 (DC) only.
V C
Table 2. Terminal Descriptions
Terminal Description
V 24 V DC supply input
C 0 V supply return
Use only one V and C terminal to power the device. You can use the other terminals to bus
power to accessories such as proximity probe drivers. Refer to the Proximity Probe Drivers
and Electronic Accessories section for more information on using proximity probe drivers and
electronic accessories with this device.
12 | ni.com | MON-10467 User Guide
Opening and Closing the Door
Caution Disconnect external power to the MON-10467 (AC) and use the external
circuit breaker box to completely remove mains power before opening the device for
service.
Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le
boîtier de disjoncteur externe pour couper complètement l'alimentation secteur avant
d'ouvrir l'appareil pour l'entretien.
Caution Remove power to the MON-10467 (DC) before opening it for service.
Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour
l'entretien.
Notice Do not put a load on the device door while it is open.
Complete the following steps to open and close the door of the MON-10467.
1. Loosen the four captive screws on the door of the device with a 1/4 in. socket or 6 mm
(1/4 in.) flat-blade screwdriver.
2. Open the door of the device slowly.
3. Clean the gasket and gasket mating surface with a dry or damp cloth prior to closing the
device door.
4. Close the door slowly.
5. Tighten the four captive screws on the door of the device to 1.3 N · m (11.5 lb · in.).
Mounting
The MON-10467 must be mounted upright to a rigid surface such as a wall, panel, strut
channel, or metal post. For installations that may experience vibration, NI recommends using a
thread locking compound or lock nuts.
Each flange has several bolt locations as shown in the following figure. The flanges are 4 mm
(0.157 in.) thick. The V-notch on the rear facilitates mounting to a round surface such as a pipe
or pole using a pipe clamp bracket.
MON-10467 User Guide | © National Instruments | 13
Figure 1. Mounting Dimensions
293.86 mm
(11.569 in.)
267.00 mm
(10.512 in.)
312.94 mm
(12.321 in.)
279.34 mm
(10.998 in.)
286.00 mm
(11.260 in.)
139.67 mm
(5.499 in.)
76.00 mm
(2.992 in.)
56.00 mm
(2.205 in.)
127.00 mm
(5.000 in.)
127.00 mm
(5.000 in.)
20.00 mm
(0.787 in.)
Hardware needed:
M6 to M8 bolts and nuts or 1/4 in. to 5/16 in. bolts and nuts
Washers (recommended)
Complete the following steps to mount the MON-10467.
1. Place the device against the surface on which you want to mount it.
2. Insert bolts into the mounting holes, placing at least two bolts on each flange. You must
use at least four bolts in total to secure the device, but may use more than four for
additional security.
3. (Optional) place washers between the bolt and the flange and/or between the mounting
structure and nuts as needed.
4. Place nuts onto the bolts and tighten to secure them.
Installing the Antenna and Boot
Notice Never apply power or operate the MON-10467 without the antenna
installed. Doing so may damage the device.
14 | ni.com | MON-10467 User Guide
Figure 2. Antenna and Boot Parts
1
2
3
1. Antenna
2. Large boot
3. Small boot
Complete the following steps to install the antenna.
1. Slide the large boot over the base of the antenna.
2. Place the small boot over the RP-SMA connector.
3. Attach the antenna to the device and tighten to a torque of 0.45 N · m (4 lb · in.).
4. Slide the large boot down the antenna to the base.
5. Press the large boot into place to create a snug seal.
Proximity Probe Drivers and Electronic
Accessories
You can use third-party accessories such as proximity probe drivers with the
MON-10467 (AC) and MON-10467 (DC). You can install up to two proximity probe drivers
per device using the industry-standard 2 in. by 2 in. hole pattern. Refer to the figures below for
the hole patterns on the MON-10467 (AC) and MON-10467 (DC). The MON-10467 (DC) has
additional holes for mounting a small panel and can also accommodate a DIN rail up to
254 mm (10 in.). The maximum height for accessories is 88 mm (3.465 in.) from the mounting
surface. The maximum height does not apply to CTC drivers, which should be installed using
MON-10467 User Guide | © National Instruments | 15
their provided protective cap for the unused BNC connector. For two-dimensional drawings
and three-dimensional models of your device, visit ni.com/dimensions.
Figure 3. MON-10467 (AC) Proximity Probe Drivers and Electronic Accessories Hole
Pattern
14.90 mm
(0.587 in)
72.60 mm
(2.858 in)
50.80 mm
(2.00 in)
50.80 mm
(2.00 in)
79.2 mm
(3.118 in)
50.80 mm
(2.00 in)
16 | ni.com | MON-10467 User Guide
Figure 4. MON-10467 (DC) Proximity Probe Drivers and Electronic Accessories Hole
Pattern
15.10 mm
(0.594 in)
79.20 mm
(3.118 in)
92.00 mm
(3.622 in)
50.80 mm
(2.00 in)
50.80 mm
(2.00 in)
14.90 mm
(0.587 in)
72.60 mm
(2.858 in)
108 mm
(4.252 in)
27.40 mm
(1.079 in)
27.60 mm
(1.087 in)
50.80 mm
(2.00 in)
88.90 mm
(3.50 in)
119.90 mm
(4.720 in)
3.90 mm
(0.547 in)
6.20 mm
(0.638 in)
6.20 mm
(0.638 in)
6.20 mm
(0.638 in)
If you are planning to use proximity probe drivers with the MON-10467 (AC) or
MON-10467 (DC), install them before wiring your device. The following figure shows how to
connect proximity probe drivers.
MON-10467 User Guide | © National Instruments | 17
Figure 5. Typical Proximity Probe Power and Signal Wiring (MON-10467 (AC) and
MON-10467 (DC) only)
MON-10467 (AC),
MON-10467 (DC)
AI<a>–
AI<a>+
AI<b>–
V
C
AI<b>+
Typical Proximity Probe Drivers
(Case isolated from Power and Signal)
COM
Signal OUT
COM
24
VDC
–24 VDC
COM
Signal OUT
COM
–24 VDC
+
Note Ensure that you are wiring in the correct orientation. The MON-10467 is
powered by a positive-polarity DC supply voltage, whereas many proximity probe
drivers are powered by a negative-polarity DC supply voltage.
Wiring
Wiring Guidelines
Adhere to the following guidelines when wiring the MON-10467.
Caution All wiring must be insulated for the highest voltage used.
Attention Tout le câblage doit être isolé pour la plus haute tension utilisée.
Caution Disconnect external power to the MON-10467 (AC) and use the external
circuit breaker box to completely remove mains power before opening the device for
service.
Attention Débranchez l'alimentation externe du MON-10467 (AC) et utilisez le
boîtier de disjoncteur externe pour couper complètement l'alimentation secteur avant
d'ouvrir l'appareil pour l'entretien.
Caution Remove power to the MON-10467 (DC) before opening it for service.
18 | ni.com | MON-10467 User Guide
Attention Mettez le MON-10467 (DC) hors tension avant de l'ouvrir pour
l'entretien.
Notice The length of the signal cable must be no longer than 30 m (100 ft).
Notice Operate this product only with shielded cables and accessories.
Notice Refer to the MON-10467 Specifications on ni.com/manuals to make sure
that any devices you connect to the MON-10467 are compatible.
Analog Input Circuitry
Figure 6. Analog Input Circuitry (One of Four)
AI0±
AI4±
AI8±
ADC
Multiplexer
Channels 0, 4, 8
Channels 1, 5, 9
Channels 2, 6, 10
Channels 3, 7, 11
AC/DC Coupling
Amplifier
and
Prefilter
+
IEPE On/Off
Protection
Protection
Protection
AI
Ground
Current
Limited
Resistor
The MON-10467 analog input terminals are referenced to a common AI ground through a
50 Ω resistor. AI ground is not directly accessible. The MON-10467 provides overvoltage
protection for each channel. Refer to the MON-10467 Specifications on ni.com/manuals for
more information about overvoltage protection. Input signals on each channel are conditioned,
buffered, and then sampled by a 24-bit Delta-Sigma ADC. The MON-10467 has four
independent signal conditioning paths and ADCs, enabling simultaneous sampling of up to
four input channels. The following channels are sampled simultaneously:
AI0, AI1, AI2, and AI3
AI4, AI5, AI6, and AI7
AI8, AI9, AI10, and AI11
Each ADC can scan through three independent input channels for a total of 12 input channels.
You can configure each channel to AC or DC coupling. The AC coupling cutoff frequency is
configurable to 10 Hz or 2.0 Hz. You can turn the IEPE excitation on or off for each channel.
The IEPE excitation circuitry includes open and short circuit detection.
MON-10467 User Guide | © National Instruments | 19
Connecting Signals
You can connect ground-referenced or floating signal sources to the MON-10467. Refer to the
following figures for typical IEPE sensor and typical dual sensor wiring.
Figure 7. Typical IEPE Sensor Wiring
Signal Out / IEPE In
AI<0...11>+ (IEPE Source)
MON-10467
Typical IEPE Sensor
(Case Isolated from Power and Signal)
AI<0...11>–
Signal COM / IEPE Return
Figure 8. Typical Dual Sensor Wiring
Signal 1 Out / IEPE In
Signal COM / IEPE Return AI<a>–
AI<a>+ (IEPE Source)
MON-10467
Typical Dual Output (IEPE + Temperature) Sensor
(Case Isolated from Power and Signal)
AI<b>–
AI<b>+
Signal 2 OUT
Note You must install a jumper wire between the two AI- terminals as shown
above.
Note Connect the two dual-sensor outputs to simultaneously sampled channels.
Hardware needed:
0.08 mm
2
to 1.5 mm
2
(24 AWG to 14 AWG) solid or fine-stranded wire or, for better
mechanical performance, ferrules with a plastic collar over fine-stranded 0.25 mm
2
to
1 mm
2
(24 AWG to 18 AWG) wire
M16 glands (supplied by NI)
Plugs rated for Type 3 or greater ingress protection for unused ports
Tools needed:
2.5 mm flat-blade screwdriver (your own or NI part number 786911-01)
19 mm deep socket or wrench
22 mm socket or wrench
(Optional) multi-prong actuation tool (WAGO part number 279-433)
(Optional) 19 mm gland dome nut tightening tool (SEALCON part number S-1900-WR)
20 | ni.com | MON-10467 User Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

National Instruments MON-10467 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI