DKS 6003 Quick start guide

Type
Quick start guide
7”
7”
QUICKSTART “BASIC” GUIDELINES FOR MODEL 6003 - FOR A GATE UP TO 10 FEET, 300LBS AND “PULL TO OPEN”
40.5” Fixed Position
90°
Securely mount a
control box near
the actuator arm
with appropriate
hardware (not
supplied).
Gate Hinge Pivot Point
Coaxial
Cable
Antenna
Actuator
Cable
Power Conduit
Loops Conduit
Front Bracket Pivot Point
Front Bracket
Rear Bracket
(Adjustable, See Manual)
Rear Bracket Pivot Point
Manual Key Release
Closed Position
Open
Position
Control
Box
115 VAC
or Solar
Power
Input
Actuator arm and brackets MUST be level!
6003-066-R-4-20
OPEN
CLOSE
Limit
Slow Down
Unscrew 4 screws to remove cover.
Loosen nut to adjust limit sensor.
Note: This illustration shows NO
gate hinge inset. If gate hinge is
inset on wall, see “Rear Bracket
Configurations for Different Gate
Hinge Insets” in the 6003 Actuator
Arm and Control Box Mounting
manual.
Limit Sensors Adjustment
Circuit board power must
be ON to adjust limit
sensors, LEDs will light.
Cut Off Excess Bracket
Cut Off Excess Bracket
Bottom
Middle
Top
The 6003 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to
6003 Actuator Arm and Control Box Mounting manual, 115 VAC or Solar Control Box Wiring/Owner’s manuals.
3 Limit
5 Limit
4 Slo Dwn
6 Slo Dwn
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
Visit
www.dkslocator.com
to find a professional installing and servicing dealer in your area.
Manually release the arm and fully extend the powered shaft. Rotate it back two full turns before installing the arm.
Unlock operator to manually move gate.
Prevent Powered Shaft from Bottoming Out
Wiring to Circuit Board
Rotate back 2 turns before installing.
Manual Release
Fully Extended (Bottomed Out)
OPEN
CLOSE
Powered Shaft
Brown wire
Blue wire
Orange wire
Red wire
Yellow wire
Green wire
Green/Yellow wire
NOT USED
7-Wire Operator
Actuator Cable
A support bar must be
installed the entire
length of the gate to
support the pickets.
Coaxial Cable Antenna Kit
P/N 1514-073 (Sold separately)
Gate Closed
21”
Typical
27.5”
Max
Photo Sensors Height
Close Beam
Open Beam
Open Beam
Close Beam
Reversing Edge
Photo Sensor
Photo Sensor
Sensor mounted
just below actuator
arm cable.
Gate Opened
Gate Closed
Copyright 2020 DoorKing
®
, Inc. All rights reserved.
External
Entrapment
Protection
Devices
Outside
Property
Inside
Property
DO NOT
cycle operator before limit sensors and
DIP-switches have been adjusted, damage could
occur to gate and operator.
Single operator connects to
PRIMARY connection ONLY
on the 115 VAC OR Solar
control box circuit board.
1
7
8
6
5
4
3
2
PRIMARY
4302
4302
4302
5” or less
Opening Direction DIP-Switch 1 (SW 1)
Refer to YOUR chosen 115 VAC OR
Solar powered control box manuals
for complete DIP-switch settings.
Manually move the gate to the desired open or closed position. Loosen the limit nuts and
slowly slide the limit assemblies until the LIMIT LEDs on the circuit board light up.
Rear Bracket Configurations
Wall
2”
2
1
/
2
3”
Straight
5
1
/
2
Reversing Edge
is mounted
along ENTIRE
end of gate.
Potential
Entrapment
Area
“PULL to Open” Installation
Operator Pull to Open
Operator Pull to Open
Note: Only 1 monitored Device can be connected for
each cycling direction. An OPTIONAL Expansion Kit
(sold separately) will allow connection for additional
devices.
Refer to YOUR chosen 115 VAC OR Solar powered
control box manuals to wire entrapment protection
devices.
Pull to Open
Push to Open - Refer to 6003 manual
Note: Refer to 6003 manual for “Push to Open” installation.
The operator MUST OPEN GATE upon initial power up and OPEN command.
If the operator closes gate after giving open command, shut off power and
reverse this switch setting otherwise operator will NOT function correctly.
Entrapment Protection must be
provided for the gate system
where the risk of entrapment
or obstruction exists. The
operator will not run without
one or more monitored type B1
or B2 entrapment protection
devices in EACH entrapment
area.
UL 325 August
2018 Standard
ON setting.
Opens clockwise.
ON setting.
Opens counter-clockwise.
Note: If factory wired jumpers are on
operator terminal, they MUST be removed.
Connect to the 115 VAC OR Solar control box circuit board.
SW 1
1
ON
2 3 4 5 6 7 8
  • Page 1 1