Contents
Safety notices .................................v
Service information for the PCIe storage enclosures ................1
Overview of 58/88 or ED/R1 PCIe storage enclosure service ...................1
PCIe storage enclosure infrastructure ..........................2
PCIe storage enclosure features .............................3
Cabling the PCIe storage enclosure ............................4
Cabling the 58/88 PCIe storage enclosure to an 02E/4C or 05E/6C system .............4
Cabling the ED/R1 PCIe storage enclosure to an 02E/4D or 05E/6D system .............9
Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure that is attached to an 02E/4D
or 05E/6D ..................................14
Cabling the 58/88 PCIe storage enclosure to an 31E/1C or 31E/2C system .............15
Cabling the ED/R1 PCIe storage enclosure to an 31E/1D or 31E/2D system.............18
Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure that is attached to an 31E/1D
or 31E/2D ..................................20
Cabling the ED/R1 PCIe storage enclosure to an 46L/2T system ................20
Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure that is attached to an 46L/2T 22
Cabling the ED/R1 PCIe storage enclosure to an 08E/8D or 09R/MD system ............23
Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure that is attached to an 08E/8D
or 09R/MD .................................25
Cabling the ED/R1 PCIe storage enclosure to a 17M/MD or 79M/HD system ............25
Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure that is attached to a 17M/MD
or 79M/HD .................................30
Overview of problem determination ...........................32
LED use for the 58/88 or ED/R1 PCIe storage enclosure ...................33
RAID controller location code ............................33
Determining the ERM location from the RAID controller location ...............33
Determining the ERM location from the RAID controller location when using AIX ........33
Determining the ERM location from the RAID controller location when using ..........35
Determining the ERM location from the RAID controller location when using Linux ........36
Updating microcode for PCIe storage enclosure components ..................37
FRUs for the 58/88 or ED/R1 PCIe storage enclosure ....................38
Identifying a SAS fabric FRU for the 58/88 or ED/R1 PCIe storage enclosure ............38
Storage enclosure topology .............................39
Notices ...................................41
Trademarks ...................................42
Electronic emission notices ..............................42
Class A Notices .................................42
Class B Notices .................................46
Terms and conditions ................................48
iii