Atos GS700 Owner's manual

Type
Owner's manual
Digital electrohydraulic servoactuators
with integral axis controller, for closed loop position and force control
AZC /-- - /
M*** EHSF CK 200 100
M V0 40
0500D D
/
1MODEL CODE
Position transducer type:
A= analog
D= digital
Cycle Generation type:
- = none
I = injection
M= mold
P= parison
S= synchronism
X= positioning
9 = customized
Digital electrohydraulic
servoactuator for linear
axis position control
Design number
Optional alternated Position/Force control:
SN = none
SP = with integral single pressure transducer
SF = with integral double pressure transducer
SL = with integral load cell transducer
XL = with remote load cell transducer
Servocylinder Type, tech table B310:
CN = ISO 6020-1, Pmax 250 bar - tech table B180
CK = ISO 6020-2, Pmax 250 bar - tech table B137
CH = ISO 6020-3, Pmax 250 bar - tech table B140, B160
CC = ISO 6022, Pmax 320bar - tech table B241
Servoproportional valve
configuration, zero spool overlap:
40 = with fail safe, sleeve execution,
direct (tech table FS180)
60 = without fail safe, sleeve execu-
tion, direct (tech table FS180)
or piloted (tech table FS178)
70 = spring central position,
direct (tech table FS168)
or piloted (tech table FS178)
Servoproportional valve size with
axis controller, tech table FS230:
V0 = direct, size 06
V1 = direct or piloted, size 10
V2 = piloted size 25
V4 = piloted size 25 or size 27
Stroke [mm]
Rod
S= single rod
D= double rod
Rod diameter [mm]
Bore diameter [mm]
Cylinder position transducer type, see section
:
Analog
(only for AZC-A)
P= potentiometer, max stroke 900mm
F = analog magnetosonic, max stroke 2500mm
N= analog magnetostrictive, max stroke 4000mm
T = LVDT, max stroke 16mm
L = LVDT, max stroke 30mm
V= inductive, max stroke 900mm
6
Digital (only for AZC-D)
M= SSI magnetosonic,
max stroke 900mm
Analog or Digital
9 = special
X= remoted
GS700
*** AZC-D-SF-EH/CKM200/100D0500/V040
Servocylinder with integral position transducer
Servoroportional valve with integral axis controller
Mainfold with double pressure transducer
Main connector
Position transducer connectors
Pressure transducer connector
Fieldbus connectors
AZC
Digital electrohydraulic servoactuators are
stand-alone units performing closed loop
position controls.
The complete motion control cycle can be
operated by external signals (from
machine PLC) or programmed internally
to the controller.
S options add alternate pressure / force
control to the basic position one with
pressure transducers or load cell factory
pre-assembled and wired.
The servoacuators are composed by a
servocylinder with position transducer,
servoproportional valve with integral
driver + axis controller, factory assembled
and tested.
They can be provided with optional
fieldbus interfaces for functional
parameters setting, reference signals and
real time diagnostics.
The USB interface is always present for
connection to Atos PC software which
allows to easily customize the AZC
configuration to the specific application
requirements.
 
Table GS700-2/E
Fieldbus interfaces, USB port always present:
NP = Not present
BC = CANopen EW = POWERLINK
BP = PROFIBUS DP EI = EtherNet/IP
EH = EtherCAT EP = PROFINET RT/IRT
2MAIN CHARACTERISTICS
4ALTERNATED P/Q CONTROLS
Assembly position Any position
Ambient temperature range standard execution = -20°C ÷ +60°C
Storage temperature range Standard execution = -20°C ÷ +70°C
Protection degree to EN60529 IP66 / IP67
Duty factor Continuous rating (ED=100%)
S options add the closed loop control of pressure (SP) or force (SF and SL) to the position control function. A dedicated algorithm alternates
pressure (force) depending on the actual hydraulic system conditions.
For detailed information about SP, SF, SL controls, see tech table GS002.
Digital servoproportionals direct or pilot operated include integral valve’s driver + axis controller to perform the position closed loop of hydraulic
actuator. Axis controllers are operated by an external or internally generated reference position signal.
For detailed information about integral axis controller see tech table FS230.
3AXIS CONTROLLER
SP SF SL
DRIVER P
T
AB
PT
M
CONTROLLER
DRIVER
T
AB
PT
M
CONTROLLER
P
P
DRIVER
T
AB
PT
M
CONTROLLER
L
Mineral oils
Hydraulic fluid
DIN 51524
ISO 12922
HL, HLP, HLPD, HVLP, HVLPD
HFDU, HFDR
HFC
Classification Ref. Standard
Flame resistant without water
Flame resistant with water
Recommended fluid temperature -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Recommended viscosity 20 ÷ 100 mm2/s - max allowed range 15 ÷ 380 mm2/s
Fluid contamination class ISO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10 μm (β10 _> 75 recommended)
Fieldbus allows the direct communication of the servoactuator with machine control unit for digital reference signal, diagnostics and settings
of functional parameters. Analog reference signal remain available on the main connector for quick commissioning and maintenance.
For detailed information about fieldbus features and specification see tech table GS510.
5FIELDBUS
03/19
6 ACTUATOR’S TRANSDUCER CHARACTERISTICS
6.1 Position transducers
The accuracy of the position control is strongly dependent to the selected position transducer. Four different transducer interfaces are
available on the controllers, depending to the system requirements: potentiometer or analog signal (A execution), SSI or Encoder (D exe-
cution). Transducers with digital interface allow high resolution and accurate measures, that combined with fieldbus communication grants
highest performances. Transducers with analog interface grant simple and cost effective solutions.
6.2 Pressure/force transducers
The accuracy of the pressure/force control is strongly dependent to the selected pressure/force transducer. Alternated pressure/force
controls require to install pressure transducers or load cell to measure the actual pressure/force values.
Pressure transducers allow easy system integration and cost effective solution for both alternated position/pressure and position/force
controls (see tech table GS465 for pressure transducers details).
Load cell transducers allow the user to get high accuracy and precise
regulations for alternated position/force control.
The characteristics of the remote pressure/force transducers must be always selected to match the application requirements and to
obtain the best performances: transducer nominal range should be at least 115%÷120% of the maximum regulated pressure/force.
6.3 Transducers characteristics & interfaces - following values are just for reference, for details please consult the transducer’s datasheet
(1) power supply provided by digital controller (2) percentage of total stroke (3) Balluff BTL7 with SSI interface is not supported
Position Pressure/Force
Execution A D SP, SF, SL
Input type Potentiometer Analog SSI (3) Incremental Encoder Analog
Power supply (1) ±10 VDC +24 VDC +5 VDC / +24 VDC +5 VDC / +24 VDC +24 VDC
Controller Interface ±10V 0 ÷ 10V 4 ÷ 20 mA Serial SSI binary/gray TTL 5Vpp - 150 KHz ±10 VDC 4 ÷ 20 mA
Max speed 0,5 m/s 1 m/s 2 m/s 2 m/s -
Max Resolution < 0.4 % FS < 0.2 % FS 1 μm1 μm (@ 0.15 m/s) < 0.4 % FS
Linearity error (2) ± 0.1% FS < ±0.03% FS < ± 0.01 % FS < ± 0.001 % FS < ±0.25% FS
Repeatability (2) ± 0.05% FS < ± 0.005% FS < ± 0.001 % FS < ± 0.001 % FS < ±0.1% FS
valve’s spool transducer actuator’s position transducer pressure transducer load cell
T
M
P
L