FormNo.3329-370RevB
MuferandSparkArresterKit
forZMaster200/500Series
ModelNo.105–1678
ModelNo.105–1679
ModelNo.105–3633
InstallationInstructions
Important:Whennishedinstallingthesparkarrestor,storethissheetwithyour
Operator’ s Man ual
for
futurereference.
Installation
LooseParts
Usethechartbelowtoverifythatallpartshavebeenshipped.
ProcedureDescription
Qty.
Use
1
Nopartsrequired
–
Maintainthesparkarrestor
2
Nopartsrequired
–
Removetheexistingblades.
Cableheatshield
1
Bolt,(1/4x3/4inch)
1
3
Locknut,(1/4inch)
1
Installthecableheatshield(ForModels
74240and74241)
Mufer
1
4
Gasket
2
Installthemufer.
Sparkarrester
1
5
Clamp
1
Installthesparkarrester.
1
MaintainingtheSparkArrestor
NoPartsRequired
Procedure
Inspectthesparkarresterevery50hoursfordamage,
suchasholesinthescreen,andforbuild-uponthe
screen.Ifitisdamaged,replaceitwithanewspark
arrester.Ifitisdirty,removeitandcleanthescreen
withawirebrushand/orsoakitinsolvent.Installitas
indicatedinthefollowingprocedures.
2
RemovingtheMufer
NoPartsRequired
Procedure
1.StopthePTO,settheparkingbrake,stoptheengine,
andremovetheignitionkey.
2.Allowthetractionunittocoolcompletely.
3.Removethemuferheatshield
4.Removethefournutsandlockwasherssecuringthe
mufertothestudsontheengine.
5.Removetheoldmuferandgasketsfromtheengine,
ensuringthatyoucleanallpiecesofthegasketsoff
oftheengineexhaustmanifold.