Miller LE107546 Owner's manual

Category
Welding System
Type
Owner's manual
AC/DC, 300/200 AC/DC, 225, And 300
Processes
Description
Arc Welding Power Source
OM-316 087 083P
December 2003
Thunderbolt XL
R
Stick (SMAW) Welding
225 And 300 Models:
AC/DC, 300/200 AC/DC Models:
Visit our website at
www.MillerWelds.com
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001:2000 Quality
System Standard.
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Mil_Thank 7/03
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE AVANT UTILISATION 5 . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Signification des symboles 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de l’appareil. 7 . . . . . . . . . . .
2-4. Principales normes de sécurité 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Information sur les champs électromagnétiques 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Symbols And Definitions 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Manufacture’s Rating Labels 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Specifications 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Duty Cycle Charts 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Volt-Ampere Curves 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Selecting A Location 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Installing Electrode Holder And Work Clamp 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Weld Output Cables 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Electrical Service Guide 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Internal Connections For Operating 115/230 Volts, 225 Amperes AC
And AC/DC Models From 115 Volts 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Internal Connections For Operating 230/400 Volts, 300/200 Amperes AC/DC Or 300 Amperes AC Mod-
els From 230 Volts 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10. Connecting Input Power 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − OPERATION 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Controls 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − MAINTENANCE & TROUBLESHOOTING 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Lubricating Shunt Block And Anti-Noise Adjustment 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Reinstalling Amperage Adjustment Indicator 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Troubleshooting 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − ELECTRICAL DIAGRAMS 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − WELDING METHODS & TROUBLESHOOTING 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Shielded Metal Arc Welding (SMAW) Procedure 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-2. Electrode And Amperage Selection Chart 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-3. Striking An Arc 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-4. Positioning The Electrode Holder 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-5. Weld Bead Characteristics 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-6. Conditions That Affect Weld Bead Shape 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-7. Electrode Movement During Welding 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-8. Butt Joints 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-9. Lap Joints 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-10. Tee Joints 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − PARTS LIST 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
OM-316 Page 1
Return To Table Of Contents
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _8/03
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-5. Read and follow all
Safety Standards.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
Y During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first − double-check connections.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturers instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-316 Page 2
Return To Table Of Contents
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
ARC RAYS can burn eyes and skin.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant mate-
rial (leather and wool) and foot protection.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
MAGNETIC FIELDS can affect pacemakers.
D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
OM-316 Page 3
Return To Table Of Contents
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
MOVING PARTS can cause injury.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained.
D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. California Proposition 65 Warnings
Y Welding or cutting equipment produces fumes or gases which
contain chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California Health &
Safety Code Section 25249.5 et seq.)
Y Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Y Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive
harm.
For Diesel Engines:
Y Diesel engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects, and
other reproductive harm.
OM-316 Page 4
Return To Table Of Contents
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
(phone: 305-443-9353, website: www.aws.org).
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping, American Welding Society Standard
AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Mi-
ami, FL 33126 (phone: 305-443-9353, website: www.aws.org).
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA
02269−9101 (phone: 617−770−3000, website: www.nfpa.org and www.
sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1735 Jefferson Davis Highway,
Suite 1004, Arlington, VA 22202−4102 (phone: 703−412−0900, web-
site: www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone:
800−463−6727 or in Toronto 416−747−4044, website: www.csa−in-
ternational.org).
Practice For Occupational And Educational Eye And Face Protection,
ANSI Standard Z87.1, from American National Standards Institute, 11
West 42nd Street, New York, NY 10036−8002 (phone: 212−642−4900,
website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone:
617−770−3000, website: www.nfpa.org and www. sparky.org).
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there
are 10 Regional Offices−−phone for Region 5, Chicago, is
312−353−2220, website: www.osha.gov).
1-6. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-316 Page 8
Revenez à la table des matières
2-4. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, norme ANSI Z49.1,
de l’American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
(téléphone : (305) 443−9353, site Web : www.aws.org).
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping, norme American Welding Society AWS
F4.1, de l’American Welding Society, 550 N.W. LeJeune Rd, Miami, FL
33126 (téléphone : (305) 443−9353, site Web : www.aws.org).
National Electrical Code, norme NFPA 70, de la National Fire Protection
Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA
02269−9101 (téléphone : (617) 770−3000, sites Web : www.nfpa.org et
www.sparky.org).
Safe Handling of Compressed Gases in Cylinders, brochure CGA P−1,
de la Compressed Gas Association, 1735 Jefferson Davis Highway,
Suite 1004, Arlington, VA 22202−4102 (téléphone : (703) 412−0900,
site Web : www.cganet.com).
Code for Safety in Welding and Cutting, norme CSA W117.2, de la Ca-
nadian Standards Association, Standards Sales, 178 boulevard
Rexdale, Rexdale (Ontario) Canada M9W 1R3 (téléphone : (800)
463−6727 ou à Toronto : (416) 747−4044, site Web : www.csa−interna-
tional.org).
Practice For Occupational And Educational Eye And Face Protection,
norme ANSI Z87.1, de l’American National Standards Institute, 11 West
42nd Street, New York, NY 10036−8002 (téléphone : (212) 642−4900,
site Web : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, norme NFPA 51B, de la National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (télé-
phone : (617) 770−3000, site Web : www.nfpa.org et www.sparky.org).
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, de l’U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (il y a
10 bureaux régionaux − Téléphone pour la Région 5, Chicago : (312)
353−2220, site Web : www.osha.gov).
2-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et les effets des champs magnéti-
ques basse fréquence sur l’organisme
En parcourant les câbles de soudage, le courant crée des champs élec-
tromagnétiques. Les effets potentiels de tels champs restent
préoccupants. Cependant, après avoir examiné plus de 500 études qui
ont été faites pendant une période de recherche de 17 ans, un comité
de spécialistes du National Research Council a conclu : « L’accumula-
tion de preuves n’a pas démontré que l’exposition aux champs
magnétiques et aux champs électriques à haute fréquence constitue un
risque pour la santé humaine ». Toutefois, les études et l’examen des
preuves se poursuivent. En attendant les conclusions finales de la re-
cherche, il serait souhaitable de réduire l’exposition aux champs
électromagnétiques pendant le soudage ou le coupage.
Afin de réduire les champs électromagnétiques en milieu de travail, res-
pecter les consignes suivantes :
1. Garder les câbles ensemble en les torsadant ou en les fixant avec du
ruban adhésif.
2. Mettre tous les câbles du côté opposé à l’opérateur.
3. Ne pas s’enrouler les câbles autour du corps.
4. Garder le poste de soudage et les câbles le plus loin possible de soi.
5. Placer la pince de masse le plus près possible de la zone de soudage.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur médecin. Si ce dernier les déclare aptes, il leur est recom-
mandé de respecter les consignes ci-dessus.
OM-316 Page 9
Return To Table Of Contents
SECTION 3 − DEFINITIONS
3-1. Symbols And Definitions
A
Amperes Single Phase
Single Phase
Transformer
Single Phase
Transformer AC &
Rectifier DC Power
Source
On Off Output
Hz
Hertz
Alternating
Current
Electrode Positive Electrode Negative
I
2
Rated Welding
Current
X
Duty Cycle Direct Current Line Connection
U
2
Conventional Load
Voltage
U
1
Primary Voltage
I
1
Rated Supply Cur-
rent
Input
V
Volts
Work Electrode
U
0
Rated No Load
Voltage (Average)
Welding Arc
3-2. Manufacture’s Rating Labels
217 854-A / 217 855-A / 165 371
U
2
X
LR5071
111
EVIDENCE OF LABEL TAMPERING VOIDS WARRANTY
TOUTE ALTÉRATION DE L’ÉTIQUETTE ANNULLE
LA GARANTIE
MILLER ELECTRIC MFG. CO.,
APPLETON, WI USA
1
Hz
A
V
A
V
%
I
2
I
1
U
1
VU
0
XXXXXX03
XXXXXXXXXXX04
XXX21
XX10
XXXXX05
XX11
X06
X27
X48
Rating Label For AC EN/FR Machines
LR5071
EVIDENCE OF LABEL TAMPERING VOIDS WARRANTY
TOUTE ALTÉRATION DE L’ÉTIQUETTE ANNULLE LA GARANTIE
MILLER ELECTRIC MFG. CO., APPLETON, WI USA
1
A
V
%
U
2
X
Hz
A
V
A
V
%
I
2
I
1
U
1
UV
0
XXXXXX03
XXXXXXXXXXX04
XXX21
XX10
XXXXX05
XX11
X06
X27
X48
XX12
X07
X28
Rating Label For AC/DC EN/FR Machines
INPUT
VOLTS
AMPERES
KW
PHASE HERTZ
SERIALNO.
STOCK NO.
EVIDENCEOFLABELTAMPERINGVOIDSWARRANTY
LR5071
Rating Label For All Other Machines
OM-316 Page 10
Return To Table Of Contents
SECTION 4 − INSTALLATION
4-1. Specifications
AC/DC Models
Mode
Rated Welding
Output
Amperage
Range
Maximum
Open-
Circuit
Amperes Input at Rated Load Output
50 Or 60 Hz, Single-Phase
Weight
Mode
Output
Range
Circuit
Voltage
115 V 220 V 230 V 400 V 460 V
Weight
AC
225 A @ 25 Volts AC,
20% Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
Low: 30 − 150
High: 40 − 235
80 VAC
95
47.5
23.7
104 lb
(47 kg)
DC
150 A @ 25 Volts DC,
20% Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
30 − 160 80 VDC
95
4.6*
47.5
2.3*
23.7
1.2*
104 lb
(47 kg)
AC
300 A @30 Volts AC,
20% Duty Cycle @ 50/60 Hz
Low: 40 − 200
High: 65 − 300
80 VAC
70
67
39
34
134 lbs
(61 kg)
DC
200 A @ 25 Volts DC,
20% Duty Cycle @ 50/60 Hz
30 − 200 80 VDC
70
5.4*
67
3.6*
39
1.8*
34
1.3*
134 lbs
(61 kg)
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
*While idling
AC Models
Rated Welding Output
Amperage
Range
Max Open
-
Circuit
Voltage
Amperes Input at Rated Load
Output 50 Or 60 Hz, Single-Phase
Weight
Rated Welding Output
Range
Circuit
Voltage
115 V 220 V 230 V 400 V KW
Weight
225 A @ 25 Volts AC, 20%
Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
Low: 30 − 150A
High: 40 − 235A
80 VAC
95
4.6*
47.5
2.3*
7.2
0.22*
85 lb
(39 kg)
300 A @ 30 Volts AC,
20% Duty Cycle @ 50/60 Hz
Low: 40 − 200
High: 65 − 300
80 VAC
70
5.4*
67
3.6*
39
1.8*
11.5
0.22*
107 lb
(49 kg)
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
*While idling
OM-316 Page 11
Return To Table Of Contents
4-2. Duty Cycle Charts
2 Minutes Welding 8 Minutes Resting
SB-086 727 / SB-099 602-A
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
Y 20% Duty Cycle at 225 Amperes. Ex-
ceeding duty cycle can damage unit
and void warranty.
B. For 220, 230/400, And 460 Volt Models
(300/200 Amperes)
A. For 115/230, 230, And 460 Volt Models
(225/150 Amperes*)
*These models have a 15% duty cycle when used with 50 Hz input power.
2 Minutes Welding 8 Minutes Resting
ST-001 836-A / SB-099 603-A
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
Y 20% Duty Cycle at 225 Amperes. Ex-
ceeding duty cycle can damage unit
and void warranty.
B. For 220, And 230/400 Volt Models
(300 Amperes)
A. For 115/230 And 230 Volt Models
(225 Amperes*)
*These models have a 15% duty cycle when used with 50 Hz input power.
OM-316 Page 12
Return To Table Of Contents
4-3. Volt-Ampere Curves
193 509 / 193 510 / 193 511 / 193 512
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities.
Curves of other settings fall be-
tween the curves shown.
A. For 115/230, 230 And 460 Volt Models
(225/150 Amperes)
B. For 220, 230/400, And 460 Volt Models
(300/200 Amperes)
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400
DC Amperes
DC Volts
MIN
MAX
0
10
20
30
40
50
60
70
80
90
100
0 50 100 150 200 250 300 350 400 450
AC Amperes
A=LOW RANGE
B=HIGH RANGE
A
A
B
B
0
10
20
30
40
50
60
70
80
0 50 100 150 200 250
DC Amperes
DC Volts
0
10
20
30
40
50
60
70
80
90
0 50 100 150 200 250 300 350
AC Amperes
AC Volts
AC Volts
OM-316 Page 13
Return To Table Of Contents
B. For AC Models
193 508 / 193 513 / 193 511
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities.
Curves of other settings fall be-
tween the curves shown.
A. For 115/230 And 230 Volt Models
(225 Amperes)
B. For 220 Volt Model
(300 Amperes)
C. For 230/400 Volt Model
(300 Amperes)
0
10
20
30
40
50
60
70
80
90
0 100 200 300 400 500
AC Amperes
AC Volts
0
10
20
30
40
50
60
70
80
90
100
0 50 100 150 200 250 300 350 400 450
AC Amperes
AC Volts
A=LOW RANGE
B=HIGH RANGE
A
A
B
B
0
10
20
30
40
50
60
70
80
90
0 50 100 150 200 250 300
AC Amperes
AC Volts
A=LOW RANGE
B=HIGH RANGE
A
A
BB
OM-316 Page 14
Return To Table Of Contents
4-4. Selecting A Location
Ref. ST-151 556 / ST-217 855-A
1 Rating Label (See Section
3-2)
Locate unit near correct input
power.
Y Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
18 in (457 mm) for airflow
1
OM-316 Page 15
Return To Table Of Contents
4-5. Installing Electrode Holder And Work Clamp
ST-802 251 / ST802 105-C
Y Turn Off unit and disconnect
input power before installing
electrode holder or work
clamp.
Removing Barrel From Elec-
trode Holder
1 Electrode Holder
2 Barrel
3 Access Hole
4 Set Screw
Loosen set screw through access
hole and slide barrel away from
electrode holder.
Installing Electrode Cable and
Barrel onto Electrode Holder
5 Electrode Cable From Unit
(Has Bare Conductors on
End)
6 Terminal Screw
Back out terminal screw from elec-
trode holder. Insert electrode cable
through barrel into end of electrode
holder and tighten terminal screw
securely.
Move barrel toward electrode hold-
er and tighten set screw to secure
barrel in place.
Installing Work Cable onto Work
Clamp
7 Work Clamp
8 Work Cable From Unit (Has
Ring Terminal on End)
9 Mounting Bolt
Route work cable through work
clamp as shown and install onto
mounting bolt using supplied hard-
ware.
1
4
2
3
8
9
7
6
5
1/4 in
Tools Needed:
1/2 in
4-6. Weld Output Cables
For weld output cable replacements or extensions, contact your Factory
Authorized Service Agent.
NOTE
OM-316 Page 16
Return To Table Of Contents
4-7. Electrical Service Guide
Input Voltage
115 220 230 400 460
Input Amperes At Rated Output
95 [70]
47.5
[67]
[39]
23.7
[34]
Max Recommended Standard Fuse Or Circuit Breaker Rating
In Amperes
150 [110]
70
[100]
[60]
35
[50]
Min Input Conductor Size In AWG/Kcmil
8 [8]
12
[10]
[14]
14
[14]
Max Recommended Input Conductor Length In Feet (Meters)
32 (10) [75 (23)]
87 (26)
[82 (25)]
[101
(31)]
138 (42)
[87 (27)]
Min Grounding Conductor Size In AWG/Kcmil
8 [8] 12 [10] [14]
14
[14]
[ ] Electrical Service Requirements For 300/200 AC/DC And 300 AC Models
Reference: 1997 National Electrical Code (NEC) Ref. S-0092-J
OM-316 Page 17
Return To Table Of Contents
4-8. Internal Connections For Operating 115/230 Volts, 225 Amperes AC
And AC/DC Models From 115 Volts
Follow applicable electrical codes and have a competent electrician make internal
connections. Note the input amperes as stated in Section 4-7.
NOTE
Y Turn Off unit and disconnect input
power.
1 Wrapper
Remove wrapper.
2 Jumper Leads
Cut tie wrap securing jumper leads to power
cord lead and remove jumper leads.
3 Lead 2
4 Lead 3
Remove insulated sleeving, and disconnect
lead 2 from lead 3.
5 Lead 4
6 Power Switch S1 (As Viewed From
Rear Of Switch)
Disconnect lead 4 from terminal 2 on S1.
Connect lead 3 and one end of jumper lead to
terminal 2.
Connect other end of jumper lead to terminal
4 on S1. Be sure existing connection to that
terminal remains.
7 230 V Input Power Cord Black Leads
8 Green Ground Lead (On Rear Panel)
Disconnect input power cord black leads from
S1, and disconnect green ground lead from
ground terminal on rear panel.
9 Input Power Cord Strain Relief
Loosen strain relief, and remove 230 volt in-
put power cord.
Obtain correct size and length 115 volt input
power cord (see Section 4-7). Install correct
size ring terminals to cord leads.
Route cord through strain relief, and connect
green lead to ground terminal.
. To install large power cords, remove
knock-out located on lower rear panel of
unit, insert power cord, and install plug
into original power cord hole.
Y Make sure paint has been removed
from area where ground terminal is
secured on unit.
10 115 V Input Power Cord White Lead
Connect lead 2, lead 4, and white input power
cord lead together, and secure with existing
hardware. Reinstall insulated sleeving.
11 115 V Input Power Cord Black Lead
Connect black input power cord lead and
jumper lead to terminal 3 on S1.
Connect other end of jumper lead to terminal
1 on S1.
Use tie-wraps to secure all leads away from
transformer, stabilizer and fan. Be sure leads
are clear of movable shunt.
Tighten strain relief, and install wrapper.
Connect input power according to Section
4-10.
5/16, 3/8 in
(cut tie wraps)
Ref. 802 247-E
7
6
4
3
2
230V Connection 115V Connection
1
Tools Needed:
7/16 in
5
8
9
4
1
2
3
Power Switch
S1 Terminals
6
3
2
4
5
8
2
10
11
To Fan
To Fan
To Fan
To Fan
OM-316 Page 18
Return To Table Of Contents
4-9. Internal Connections For Operating 230/400 Volts, 300/200 Amperes AC/DC Or 300
Amperes AC Models From 230 Volts
Follow applicable electrical codes and have a competent electrician make internal
connections. Note the input amperes as stated in Section 4-7.
NOTE
Ref. ST-802 247-D
1
2
3
4
5
6
7
2
3
5
6
Connected For 400 Volts
Connected For 230 Volts
5/16, 3/8 in
(cut tie wraps)
Y Turn Off unit and disconnect
input power.
1 Primary Coil Lead 4
2 Lead 4 Insulation Sleeving
3 Power Switch Lead 4
4 Lead Connection Hardware
Slide Sleeving down, and discon-
nect one lead 4 from the other. Re-
move sleeving.
5 Fan Motor (FM) Lead 2
6 Lead 2 Insulation Sleeving
Disconnect fan motor lead 2 at fan
motor, and remove sleeving.
Take lead 2 sleeving and secure it
over the end of primary coil lead 4.
Replace lead 2 sleeving with lead 4
sleeving.
7 Primary Coil Lead 2
Slide sleeving out of the way, and
connect power switch Lead 4 to pri-
mary coil lead 2, and secure with
existing hardware. Secure sleeving
over connection.
Connect fan motor lead 2 back onto
fan motor.
Reinstall wrapper.
7
Tools Needed:
OM-316 Page 19
Return To Table Of Contents
4-10. Connecting Input Power
ST-802 246
Y Disconnect and lockout/tag-
out input power before con-
necting input conductors
from unit.
Y Have only qualified persons
make this installation. See
rating label in Section 4-4, and
be sure to supply correct in-
put power.
1 Line Disconnect Device
2 Input And Grounding
Conductors For Models Not
Supplied With Plug
See Section 4-7 for conductor and
fuse size and ratings. Size and
ratings must comply with applicable
codes.
3 Plug
4 Proper Receptacle
(User-Supplied)
GND/PE
L1
2
3
Install conductors into a deenergized line
disconnect device.
Y Always connect
grounding
conductor first.
4
L2
1
OM-316 Page 20
Return To Table Of Contents
SECTION 5 − OPERATION
5-1. Controls
A. Controls For AC/DC Models
Ref. ST-190 600-B / ST-802 105-C
1 Amperage Adjustment Control
2 Power Switch
3 Mode Switch
For DC Weld Output
Use mode switch to select polarity
of dc output, Electrode Posi-
tive/DCEP (+),or Electrode Nega-
tive/DCEN (−).
For AC Weld Output
Use mode switch to select ac low
range or high range output.
3
1
2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Miller LE107546 Owner's manual

Category
Welding System
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages