Cooper Lighting CT Circuit T Installation guide

Type
Installation guide
Risk of Fire and Electrical Shock- MWS must
be installed by qualified personnel. If not
qualified, consult an electrician.
Risk of Electric Shock- Disconnect power at
fuse or circuit breaker before installing or
servicing.
Ensure both latches are securely fastened-
Unlatched connections can separate causing
arcing and overheating of the connectors.
WARNING
IMPORTANT: Read, understand and follow all MWS
safety and installation instructions. Retain for future
reference.
NOTICE: Installation must comply with all applicable
national and local codes. Manufactured wiring systems
covered by Article 604 of the National Electrical Code.
NOTICE: Do not use any MWS component for other
than it’s intended purpose.
NOTICE: Do not tamper with the internal wiring of any
MWS component or physically modify in any way.
NOTICE: Starter fitting/starter fixture cable is
the starting point of the MWS system. All MWS
components attached to the system will be energized.
Cap all unused connector openings.
Installation Instructions – MWS 0-10V Dimming
Instructions d’installation–Système de câblage modulaire de
gradation0 à 10V
Instrucciones de instalacn – Atenuacn MWS 0-10V
IMPORTANT: Save installation instructions for future changes.
IB519111EN
MWS
Failure to comply with these instructions may result in
death, serious bodily injury and property damage.
DISCLAIMER OF LIABILITY: Eaton assumes no liability
for damages or losses of any kind that may arise
from the improper, careless, or negligent installation,
handling or use of this product.
INSTALLATION
1. Standard carton size 14”W x 14”L x 12”H
Half carton size 14”W x 14”L x 6”H.
2. Each carton label list component cat. no. quantity,
length voltage with photograph.
3. Standard pallet size: 32”W x 46”L x 42”H
Max. 18 cartons per pallet. Pallets are shrink
wrapped by Cooper.
120V/277V/347V
Grey
Purple
Black
White/Neutral
Green
0-10V Dimming
5
4
3
2
1
5
4
3
2
1
MWS Standard Contact Configuration
CAUTION
Only use with compatible MWS 0-10V
components.
0-10V Dimming
12/2G
10/2G
2
Consult MWS Installation, Application and Specification Manual for
additional comprehensive system information.
Starter Fitting/Starter Cable
MWS IB519111EN Installation instructions
Installation Instructions – MWS 0-10V Dimming
System View (not to scale)
Dimensional and Mounting Details
Starter (ST)
Converts conventional wiring to MWS. Branch circuits are fed from the panel to a junction box with conduit and wire. The Starter is
mounted to the junction box with a 1/2” threaded lock nut connector. Circuits are then connected to the appropriate leads of the Starter.
Starter Cables have 9’, 15’ or 21’ of MC cable.
Fixture Cable
System View (not to scale)Dimensional and Mounting Details
Fixture Cable (FC)
Feeds power to fixtures and allows circuits to be carried through to other fixtures. Locks into 1/2” KO of access plate, fixture body or
J-box. The unit adds 7/8” to overall height of the fixture.
Typical MWS Wiring System Application shown utilizing Fixture Cable (FC).
Extender Cables
System View (not to scale)Dimensional and Mounting Details
Extender Cable (EC)
Supplies power between MWS components. Cables connect together without use of couplers.
Typical MWS Wiring System Application shown utilizing Extender Cable (EC).
STARTER FITTING STARTER CABLE
Unit with no cable
Unit with no cable
Starter
Starter Cable
Fixture Cable
Fixture Cable
Extender or Fixture Cable
Extender or Fixture Cable
Front
3/4”
[19mm]
3/4”
[19mm]
4-3/8”
[112mm]
1-7/8”
[47mm]
4-3/8”[112mm] 4-3/8”[112mm]
3/4”
[19mm]
5/8”
[16mm]
4-3/8”
[112mm]
5/8”
[16mm]
1-7/8”
[47mm]
4-3/8”
[112mm]
3/4”
[19mm]
4-3/8”
[112mm]
Front
To p
Front
Fixture Cable Fixture Cable Fixture Cable
Quick Connect
Front
Front Front
Starter
Circuit T
Extender Cable
Switch Drop
Fixture Cable
Fixture
Cable
Fixture
Cable
Fixture Cable
Extender
Cable
Extender Cable
Drop SO Cord
Switch
Drop
To p
Side
To p
Side
To p
Side Side
3
MWS IB519111EN Installation instructions
Installation Instructions – MWS 0-10V Dimming
Circuit T
System View (not to scale)Dimensional and Mounting Details
Circuit T (CT)
Feeds power through and taps desired circuit to other fixtures.
Typical MWS Wiring System Application shown utilizing Circuit T (CT).
T Cable
System View (not to scale)Dimensional and Mounting Details
T Cable (TC)
Consult MWS Installation, Application and Specification Manual for
additional comprehensive system information.
Drop Cable
System View (not to scale)Dimensional and Mounting Details
Drop Cable (DC)
Supplies power to out of system units. (Fixtures, J-boxes, etc.).
Typical MWS Wiring System Application shown utilizing Drop Cable (DC).
Front
Side
Extender Cable Extender CableT Cable
To p
Side
Drop Cable
Extender Cable
Extender Cable
Junction Box
or any Out of
System Unit
supplied by
others.
Splitter or
Circuit T
To p
To p
Right
2-1/4”
[57mm]
2-1/4”
[57mm]
2-1/4”
[57mm]
5-5/16”
[136mm]
5-5/16”
[136mm]
5/8”
[16mm]
1-7/8”
[47mm]
4-3/8”
[112mm]
1-13/16”
[45mm]
Circuit T
Extender Cable
Extender Cable
Drop SO Cord Drop SO Cord
4
Consult MWS Installation, Application and Specification Manual for
additional comprehensive system information.
MWS IB519111EN Installation instructions
Installation Instructions – MWS 0-10V Dimming
Starter Fixture Cable
Dimensional and Mounting Details
Starter Fixture Cable (SF)
Fixture Fitting
System View (not to scale)Dimensional and Mounting Details
Fixture Fitting (FF)
Feeds power to fixture and allows circuits to be carried through to other fixture.
Locks into 1/2” KO of access plate, fixture body or J-box. The FF adds only 7/8”
to overall height of the fixture.
Typical MWS Wiring System Application shown utilizing (FF).
3/4” [19mm]
4-3/8”
[112mm]
Front
Side
To p
Quick Connect
Quick Connect
Extender Cable Extender CableFixture Fitting
5-5/16”
[136mm]
2-1/4”
[57mm]
Front
Side
To p
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2019 Eaton
All Rights Reserved
Printed in USA
Imprimé aux États-Unis
Impreso en los EE. UU.
Publication No. IB519111EN
September 5, 2019
Eaton is a registered trademark.
All trademarks are property
of their respective owners.
Eaton est une marque de commerce
déposée. Toutes les autres marques
de commerce sont la propriété de leur
propriétaire respectif.
Eaton es una marca comercial
registrada. Todas las marcas
comerciales son propiedad de sus
respectivos propietarios.
Product availability, specifications,
and compliances are subject to
change without notice
La disponibilité du produit, les
spécifications et les conformités
peuvent être modifiées sans préavis
La disponibilidad de productos, las
especificaciones y los cumplimientos
están sujetos a cambio sin previo aviso
Conector de la luminaria
Vista del sistema (no a escala)Detalles dimensionales y de montaje
Conector de la luminaria (FF)
Alimenta a las luminarias y permite que los circuitos se transporten a otras
luminarias. Se bloquea en un orificio ciego de 1/2” de la placa de acceso, el
cuerpo de la luminaria o la caja de conexiones. El conector de la luminaria (FF)
agrega solo 7/8” a la altura total de la luminaria.
Aplicación típica del sistema de cableado MWS que se muestra utilizando el
conector de la luminaria (FF).
Conexión rápida
Cable de extensión Cable de extensión
Conector de la
luminaria
5-5/16"
[136 mm]
2-1/4"
[57 mm]
Frente
Lado
Parte superior
Warranties and Limitation of Liability
Please refer to www.eaton.com/LightingWarrantyTerms for our terms and conditions.
Garanties et limitation de responsabilité
Veuillez consulter le site www.eaton.com/LightingWarrantyTerms pour obtenir les conditions générales.
Garantías y Limitación de Responsabilidad
Visite www.eaton.com/LightingWarrantyTerms para conocer nuestros términos y condiciones.
FCC Statement
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Declaración de la FCC
Nota: Este equipo ha sido probado y cumple con los límites para un
dispositivo digital de Clase A, de conformidad con la parte 15 de las
Normas de la FCC. Estos límites están diseñados para proporcionar
una protección razonable contra interferencias perjudiciales cuando el
equipo se opera en un entorno comercial. Este equipo genera, utiliza y
puede emitir energía de radiofrecuencia y, si no se instala y utiliza de
acuerdo con el manual de instrucciones, puede causar interferencias
perjudiciales en las comunicaciones de radio. El funcionamiento
de este equipo en un área residencial puede causar interferencias
perjudiciales, en cuyo caso el usuario deberá corregir las interferencias
por su cuenta.
Instrucciones de instalación – Atenuacn MWS 0-10V
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Cooper Lighting CT Circuit T Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI