innovair 4-WAY CASSETTE User manual

Category
Split-system air conditioners
Type
User manual

This manual is also suitable for

,QQRYDLU0LQL95))XOO'&,QYHUWHU7HFKQRORJ\+]
R-410
Key Features
All DC Inverter Technology to Improve Compression Efficiency
Sensorless DC Inverter Fan Motor
All DC rotary inverter compressor and high-performance high pressure
chamber is adopted to reduce overheat loss improving compression
efficiency from direct intake.
Compared with low pressure chamber, the compression efficiency is
improved. High efficiency permasyn motor is adopted to provide better
performance than traditional inverter compressor.
The unique Innovair DC Twin Rotary compressor driving technology with
range from 30 to 90 Hz allows maximum adaptability to the required
conditions.
Compressor Efficiency
0 20 40 60 80 100
High-efficiency permasyn (permanent
magnets) motor is adopted to provide better
performance than traditional DC inverter
compressors.
Stepless speed regulation ranges from 5 Hz to 44 Hz. Compared
with traditional inverter motors, the operation is more energy-
saving.
Comfortable and Quiet Mode
Sensorless control technology ensures lower
noise, less vibration, and more stable operation.
Rotating speed (rps)
Concentrated Winding
Distributed Winding
510 15 20 25
35
30
40 45 50 55 60 65
Output of Inverter Compressor
Step Regulation
Innovair Stepless Regulation
Frequency of Inverter Fan motor
Before After
1
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
High Pressure chamber
structure can raise the high
and middle frequency
performance.
New DC motor (concentrated
winding) raises the low frequency
performance
The advanced sub-cooling control technology is applied to reduce the liquid
flow noise of indoor unit in cooling operation.
Noise of outdoor unit can be as low as 45dB thanks to nise optimized design
or fan system and compressor system, and multiple kinds of quiet modes of
outdoor unit.
Low Noise of 2XWGRRU Unit
High Efficiency and More Energy Saving
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
2
The patented high-efficiency centrifugal fan blade and low-noise volute are adopted.
Meanwhile, the imported silent valve is adopted to reduce noise of entire unit as low
as 22dB(A).
Optimal inlet angle of centrifugal fan and optimal diameter ratio between internal and
external circles of impeller, the air volume is increased and fan noise is decreased
greatly.
Low Noise of Indoor Unit
Quiet Indoor Unit
The CAN2 bus communication technology is adopted, with non-polar communication and high anti-interference ability.
Common communication wire can meet the communication demand with no need of specialized shielded wire.
Customers can buy the communication wire by themselves, greatly reducing installation difficulties.
Ultra-long Connection Pipe for More Convenient Connection
Under the subcooling control technology gained by adding subcooler, the indoor unit and outdoor unit of Innovair
Mini-VRF can operate reliably with longer connection pipe.
Top Advanced Light Compact Size
Innovair Mini-VRF adopt small and compact size design. Size and weight are reduced a lot.
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
3
Innovair Mini-VRF Full DC 50/60Hz
Lineup
Technical Specifications
IOV03H7MDC713
Model -IOV04H7MDC716 IOV05H7MDC719
HP 4
12.1
14
11.5
220 - 240V / 1 Ph / 50Hz and 208 - 230V / 1 Ph / 60Hz
28.1/32
3.05
3.27
7
5
55
Ø 9.52
900 * 340 * 1345
998 * 458 * 1515
110/120
Ø 15.87
5
14
16.5
10
31.8/32
3.98
3.99
8
5
56
6
16
18.5
9.7
33.6/40
4.85
4.67
9
5
58
Ø 19.05
kW
kW
A
kW
kW
unit
kg
kg
dB(A)
mm
mm
mm
mm
W/W
V/Ph/Hz
Capacity Range
Capacity
EER
Power Supply
Max. Circuit/Fuse Current
Power Comsumption
Max. drive IDU No
Refrigerant Charge Volume
Sound Pressure Volume
Connecting pipe
Net Weight/Gross Weight
Dimension
(W*D*H)
Liquid
Outline
Package
Gas
Cooling
Cooling
Heating
Heating
Ø 9.52
1. Testing conditions of rated cooling capacity: indoor 27oC/19oCDB, outdoor 35oCDB, connection pipe lenght of 5 m, no height
difference between units.
2.
Testing conditions of rated heating capacity: indoor 20oC, outdoor 7oCDB/6oCWB, connection pipe lenght of 5 m, no height
difference between units.
3.
The total indoor unit capacity shall be within 50% to 130% of outdoor capacity. Correction of other parameters can be referred to the
unit capacity correction sheet.
4. The above mentioned parameters are tested with standard connection pipe lenght. In actual engineering, please arrange correction
according to the capacity correction with long connection pipe.
NOTES:
R-410
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
3
Innovair Mini-VRF Full DC 50/60Hz
Lineup
Technical Specifications
IOV03H2MDC707
Model -IOV04H2MDC708 IOV05H2MDC709
Ton 3
37500 (3.0)
16
208 - 230V / 1 Ph / 60Hz

32
50
7
5/176
55
Ø 3/8
35 - 3/7 * 13 - 2/5 * 53
242.6 / 264.6
Ø 5/8
4

3

8
5/176
56
4-6
42 / 70
4

9
5/176
58
Btu/h (Ton)
A
unit
kg/OZ
Lbs
dB(A)
in
in
Btu-h/W
V/Ph/Hz
Capacity Range
Capacity
SEER
Power Supply
0$;&,5&8,7)86(&855(17
Power Comsumption
Max. drive IDU No
Refrigerant Charge Volume
Sound Pressure Volume
Connecting pipe
Net Weight/Gross Weight
Dimension
(W*D*H)
Liquid
Outline
Package
Gas
Cooling
Heating
R-410
Btu/h (Ton)
48000 (4.0) 60000 (5.0)
42000 (3.5) 54000 (4.5) 66000 (5.5)
37 * 12 - 3/5 * 56 - 2/7
40 - 2/3 * 17 * 62 -1/5
39 - 2/7 * 18 * 59 - 2/3
271 / 295
in
in
Ø 3/8
Ø 5/8
16 16
MCA
MOP
A
A
Innovair VRF Full DC Specifications of Indoor Units (50/60Hz)
Type of
Indoor
Unit
High Static
Pressure
Duct Type
ITV---H7A7
ITV--H7A7
ITV-H7L7
MODEL 008 010 013018020 025032 040 044 048 060 080 100
CAPACITY
(KBTU/h)
Specifications of Indoor Units
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
4
ITV-H7B7
ICV-H7S7
ICV-H7M7
ICV-H7O7
High Static
Pressure
Duct Type
Low Static
Pressure
Slim Duct Type
Low Static
Pressure
Duct Type
IWV-H2N7
4-Way
Cassette
Compact 4-Way
Cassette
1-Way Cassette
Wall-mounted
Type
Floor Ceiling
Type IUV-H7N7
Air Handler IDV-H7N7
Floor
Standing
Type ISV-H7N7
R-410
Notes
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
5
Ideas innovadoras en aires acondicionados
Conéctate con nosotros
INNEINVVIUE150201
www.innovair.com
© 2015 Innovair Corp. -Todos los derechos reservados. Discl. www.innovair.com
R-410
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

innovair 4-WAY CASSETTE User manual

Category
Split-system air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI