Microh Ultra Wash 1200 User manual

  • Hello! I am an AI chatbot trained to assist you with the Microh Ultra Wash 1200 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INTRODUCTION
This equipment is produced in accordance with CE standards and conforms to the
international standard DMX512 protocol.
On receiving this product, please carefully check that there has been no damage caused
in transportation and that the following parts are enclosed:
1 1200W WASH MOVING HEAD
1 SIGNAL CABLE
1 USER MANUAL
1 SAFETY CABLE
2 CLAMPS
IMPORTANT
BEFORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE
REAR PANEL OF THIS UNIT IS THE SAME AS THE SUPPLIED MAINS POWER IN YOUR
AREA.
READ THIS USER MANUAL CAREFULLY BEFORE OPERATION
SAFETY WARNING
This product must be installed by a qualified professional
All operation and maintenance must be carried out in accordance with this user manual.
Keep this device away from any form of water or moisture at all times.
Always disconnect the power before attempting to open the equipment housing or
carrying out any maintenance.
Avoid looking directly into the light source (especially those who suffer from epileptic
fits)
DO NOT touch the equipment casing during operation due to high temperatures of the
metal and plastic housing.
This equipment is designed for indoor use only.
ATTENTION
This product left our premises in perfect condition. In order for safe operation and to
maintain the original condition, the user must always follow the instructions and safety
warnings described in this user manual.
The manufacturer cannot accept liability for any resulting damages caused by non-
observance of this manual or any unauthorized modifications to the equipment and are
not subject to warranty.
Always make sure that the equipment is OFF before connecting the power cables.
Always make sure that the power cable is never cut or damaged by sharp edges. It is
advisable to check the state of the power cable from time to time.
DO NOT connect this equipment to a dimmer rack.
This device falls under Protection Class I. Therefore it is essential that the
yellow/green wire must be earthed.
If during transportation or storage the equipment has gone through drastic temperature
changes, it is advisable to allow some time for the equipment to first adjust to room
temperature before operation.
1
Never turn on the equipment without a lamp
Avoid shaking of strong impacts to the equipment.
Never lift the equipment by holding it at the head or arms. Always use the handles on
the base.
DO NOT turn on the lamp at short intervals as this will reduce the lamp's life.
The maximum ambient temperature of the housing is ta=45 . If the temperature is in
excess of this the thermal switch will shut off the power.
When transferring the product, it is advisable to use the original packaging that the unit
left the factory in.
REAR PANEL OF THE BASE
The head must be locked for transportation-the tilt lock button is pushed and the pan
lock/unlock lever is in lock position. To unlock the head, press the tilt unlock button and
move the pan lock/unlock lever to unlock position.
DESCRIPTION
5 Pin DMX output
5 Pin DMX input
Live fuse holder
Power switch
Power cord
Moving head
Tilt lock button
Pan lock button
Handel
3-pin DMX output
3-pin DMX input
2
Color wheel 1
Lamp chamber
Coluor wheel 2
Thermostat
Ignitor
Inside fresnel lens
CMY/CTO
filter module
Lamp cover
3
Description of the fixture
DIMENSIONS
489 mm
151 mm
585 mm
602 mm
525mm
506 mm
4
LAMP ADJUSTMENT
REPLACING LAMP
CAUTION: ALWAYS SWITCH OFF AND UNPLUG AT THE MAINS BEFORE
INSTALLING THE LAMP
1. Disconnect the power and all the unit to cool for at least 10 minutes.
2. Loosen screws indicated A & B on the lamp cover at the back of the head.
3. Gently pull and remove the lamp cover and lamp holder from the head.
4. Holding the lamp by its ceramic base, carefully pull the lamp straight out of the lamp
socket.
5. Holding the new lamp by its ceramic base, gently insert the lamp in to the lamp socket.
6. Reinsert the lamp cover and lamp holder and tighten screw A & B.
IMPORTANT:
Ø Always make sure that the lamp is installed tightly into the lamp socket.
Ø DO NOT install a lamp other than that specified in this user manual.
Ø DO NOT touch the glass area of the lamp with bare hands.
When this product left the factory, the lamp holder was calibrated here. However, due to
the possibility of small deviations between lamps, fine adjustments after replacement may
improve light output.
1. Turn on the lamp and operate with white beam (i.e. no effects)
2. Open the shutter and the iris with the dimmer intensity at 100%.
3. Focus the light beam on a flat surface (i.e. wall/floor)
4. Center the hot-spot (the brightest part of the image) using the 3 adjustment screws
X, Y & Z.
5. Once the hot-spot has been centered, remove the hot-spot and balance the light
output by turning the adjustment screws a quarter-turn clockwise one after another. If
the hot-spot cannot be located, adjust the lamp until the light output is evenly
Disconnect the fixture from AC power before re-lamping.
Lamp is hot! Risk of fire! Protect hands and eyes.
Wait at least 15min. before opening
the covers and removing
lamp from the fixture.
Lamp
Lamp holder
Fixed the lamp holder
of screw(A,B)
Adjust screw (X,Y,Z)
INSTALLATION
5
6
5, Inserting / Exchanging colours
Danger of fire! When installing the device, make sure there is no highly in ammable
material (decoration articles, etc.) In between a distance of min 1.3M.
CAUTION! Use 2 appropriate clamps to rig the fixture on the truss. Follow the instructions
mentioned at the bottom of the base. Make sure that the device is fixed properly! Ensure that
the structure (truss) to which you are attaching the fixture is secure.
The installation of the fixture has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. And
appropriate catch net. This secondary safety attachment must be constructed in a way that
no part of the installation can fall down if the main attachment falls.
The moving heads can be placed directly on the stage or rigged in any orientation on a truss
without altering its operation characteristics:
Open the bottom cover of the moving head by loosening the 4 quarter-turn fasteners on the
top cover and follow the instruction s below:
Gently bend out the colour module to release it from the fixative holes and eject it from the
pressing snap. Put the new colour module back under the pressing snap and push it to the 3
fixative notches.
CAUTION: Make sure the colour modules be locked well when you push it to fixative
notches.
For overhead use, always install a
safety-rope that can hold at least 10
times the weight of the fixture. You
must only use safety ropes with
screw-on carabines. Pull the safety
rope through the two apertures on the
bottom of the base and cover the
trussing system etc. Insert the end in
the carabine and tighten the fixation
screw.
Colour wheel
Colour module
Colours
Pressing snap
Colour module
6, Rigging the fixture
Clamp
Omega Holder
Plate
Safty-rope
Nut Ring
The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.
The sockets are wired in parallel.
DMX-OUTPUT
DMX-input
1- Ground
2 - Signal (-)
3 - Signal (+)
4 - Free
5 - Free
Occupation of the XLR-connection:
XLR mounting-socket:
XLR mounting-plug:
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator.
Solder a 120 resistor between Signal (-) and Signal (+) into a 3-pin XLR-plug and plug
it in the DMX-output of the last fixture.
The transform of the controller line of 3 pins and 5 pins (plug and socket)
DMX-512 connection/connection between fixtures
Possible omega holder 4 positions:
5
120
7
DMX512 CHANNEL FUNCTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Pan
Pan Fine 16BIT
Tilt
Tilt Fine 16BIT
Pan & Tilt Speed
Lamp on/off, Reset
Colour Wheel 1
Cyan
Magenta
Yellow
3200K Coversion Temperature Effect-- CTO
CYM +CTO Color Mix effect
Channel
Function
Colour Wheel 2
CYM +CTO Speed adjust
Fresnel Opening
Zoom
Strobe
Dimmer Intensity
8
Channel 1 Pan movement
Pan movement by 540
Function
Value
255 100
Channel 3 Tilt
Tilt movement by 280
Channel 2 Pan fine
0 0.0
Fine controlof
pan movement
proportional
Function
Value
255 100
0 0.0
Function
Value
255 100
0 0.0
9
Channel 4 Tilt Fine
Channel 5 Pan & Tilt speed
Channel 6 Lamp on/off, Reset
240~255
230~239
140~229
128~139
0~127
No effect
Lamp off after 3
seconds
No effect
Lamp on and Reset
No effect
94~100
90~94
55~90
50~55
0~50
Fine control of
Tilt movement
proportional
Function
Value
255 100
0 0.0
From fast to slow
Function
Value
255 100
0 0.0
Slow
Value
Function
Fast
Fast
10
Channel 9 Cyan
0~100% Cyan
proportional
Channel 7 Color wheel 1
197~255
182
169
156
143
130
117
104
83 97~
69 82~
56 68~
42 55~
28 41~
14 27~
013~
Forward rainbow effect
from slow to fast
UV filter
6000K Temperature filter
Deep Green
Deep Orange
Deep Blue
Deep Red
White
UV filter
6000K Temperature filter
Deep Green
Orange
Deep Blue
Deep Red
White
77~100
71
66
61
56
51
46
41
32~28
27 32~
22~27
16~22
11~16
5~11
0~5
Channel 8 Color wheel 2
197~255
182
169
156
143
130
117
104
83 97~
69 82~
56 68~
42 55~
28 41~
14 27~
013~
Forward rainbow effect
from slow to fast
White
Red ring
Blue dot
Yellow ring
UT Filter / Orange
Green / Orange
Blue/Yellow/Magenta/
Orange
White
77~100
71
66
61
56
51
46
41
32~28
27 32~
22~27
16~22
11~16
5~11
0~5
Blue/Yellow/Magenta/
Orange
Green / Orange
UT Filter/ Orange
Yellow ring
Blue dot
Red ring
Value
Function
Value
Function
Value
Function
255
100
0 0.0
11
Channel 12 3200K CTO
0~100% 6000K~3200K
Proportional
Channel 10 Magenta
0~100% Magenta
proportional
Channel 11 yellow
0~100% Yellow
Proportional
Value
Function
255
100
0 0.0
Value
Function
255
100
0 0.0
Value
Function
255
100
0 0.0
12
Channel 13 CMY+CTO Marcos
Channel 15: Fresnel Opening
200~207
192~199
168~175
80~87
72~79
64~71
56~63
48~55
40~47
32~39
24~31
16~23
8~15
0~7
78.5~81
75~78
66~68.5
31~34
28~31
25~28
22~25
19~21.5
15.5~18.5
12.5~15
10.5~12
6.5~10
3.5~6
0~3
Marco 25
Marco 24
Marco 21
Marco 10
Marco 9
Marco 8
Marco 7
Marco 6
Marco 5
Marco 4
Marco 3
Marco 2
Marco 1
No function
88~95
34.5~37
Marco 11
96~103
37.5~40
Marco 12
104 1~11
40.5~43.5
Marco 13
112~119
44~46.5
Marco 14
120~127
47~50
Marco 15
128~135
50~53
Marco 16
136~143
53.5~56
Marco 17
144~151
56.5~59
Marco 18
152~159
59.5~62
Marco 19
160~167
62.5~65.5
Marco 20
176~183
69~71.5
Marco 22
184~191
72~75
Marco 23
208~215
81.5~84
Marco 26
216~223
84.5~87.5
Marco 27
224~231
88~90.5
Marco 28
232~239
91~93.5
Marco 29
240~247
94~97
Marco 30
248~255 97~100
Marco 31
Channel 14 CMY filter + CTO speed assigning
From fast to slow
step
Function
Value
255 100
0 0.0
Value
Function
Internal Fresnel
Opening--From close
to open-light max mode
Function
Value
255 100
0 0.0
13
Channel 16 Zoom
Channel 17 Strobe
Channel 18 Dimmer
224~255
160~191
128~159
64~95
0~31
Shutter Open speedy
Shutter open dimmer
proportional
Strobe from slow to
fast(open slowly and
close quickly)
Random strobe from
slow to fast
Shutter close
88~100
75.5~87.5
63~75
37.5~49.5
0~12
32~63
Shutter open (dimmer
proportional)
12.5~24.5
96~127
Shutter open (dimmer
proportional)
50~62.5
192~223
Random strobe from
slow to fast
25~37
Max--proportional
Min.
Function
Value
255 100
0 0.0
Dimmer intensity
from 0 to 100%
proportional
Function
Value
255 100
0 0.0
Function
Value
14
10
6670
1668
741
417 Foot-candles(center)
71800
17950
7980
4490 LUX(center)
Beam angle 10 -LightMax mode
Beam opening(m)
5
0.87
10
1.75
15
20 Distance(m)
3.50 Diameter(m)
2.62
Distance=5m
8000
6000
4000
2000
0 0
0
(LUX) (Foot-candles)
Diameter(m)
0.20.20.4 0.4 0.60.6 0.80.8
1 1
1858
3716
5574
7432
13
2812
703
312
176 Foot-candles(center)
30270
7570
3360
1890 LUX(center)
Beam opening(m)
5
1.14
10
2.29
15
20 Distance(m)
4.56 Diameter(m)
3.42
Beam angle 13 -Min zoom
4000
3000
2000
1000
0 0
0
(LUX) (Foot-candles)
Diameter(m)
0.20.20.4 0.4 0.60.6 0.80.8
1 1
929
1858
2787
3716
Distance=5m
Beam angle 42 with frost
654
1760
780
164
72
41 Foot-candles(center)
440 LUX(center)
7040
5
4.0
10
8.0
15
20 Distance(m)
16.20 Diameter(m)
12.0
44
1
1
2
2
3
3
4
4
5
5
6
7
7
6
0
Beam opening(m)
Distance=5m
8000
6000
4000
2000
0 0
0
(LUX) (Foot-candles)
Diameter(m)
0.40.40.8 0.8 1.21.2 1.61.6
2.0 2.0
186
372
557
743
Lamp:MSR 1200 SA
Fresnel lensFresnel lens
15
16
8. Technical specifications
US-model: Voltage............................AC100/110/120V , 50/60Hz
Fuse................................ T 30 A@120V
EU-model:Voltage............................AC220/230/240V ,50/60Hz
Fuse ................................T15
Rated Power 1450W
DMX512 Channel 18CHS
Luminous 96000 LM
MSR1200 SA GY 22
-Colour temperature 6000K
-Average lifespan:750hrs
Focus: electronic linear focus
Zoom: electronic zoom 10 ~44
Colour wheel:
dichroic-filters, UV, CTF 6000K plus white step/linear rotation(plus bi-directional
rainbow -flow effect), Speed adjustable
CMY+CTC:
-CMY colour mixing system
-0-100% 3200K-6000K colour temperature correction
-Linear CMY and CTS
Rigging:
-Stands directly on the floor
-Mounts horizontally or vertically with 2 clamps
-2 truss orientation
-Safety chain/cord attachment bolt
Pan / Tilt Movement:
-Pan 530 , Tilt 280
-Micro-step scan effect, 8/16 Bit
-Auto-repositioning by photoelectric repositioning system
-Linearity move speed adjust.
Dimensions and weight:
-Length of base (including handles): 506 mm
-Width of yoke: 525 mm
-Height (head horizontal): 602 mm
-Weight (net): 58 kg
A @230V
Lamp:
-
Optical System:
-
-
-Dimmer: smooth dimmer 0~100%
-Strobe: Variable speed 1~10 flashes/sec (plus random strobe effect)
-Frost filter: smooth adjust 0~100%
-Iris: Electronic linear iris
-6
Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid
residues must not buildup on or within the fixture. Otherwise, the fixtures light-output will
be significantly reduced. Regular cleaning willnot only ensure the maximum light-output,
but will also allow the fixture to function reliably throughout its life.A soft lint-free cloth
moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER :Disconnect from the mains before starting anymaintenance work
The front objective lens will require weekly cleaning as smoke-fluid tends to building up
residues, reducing thelight-output very quickly. The cooling-fans should be cleaned
monthly.
The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at
least annually using a vacuum-cleaner or an air-jet.
The dichroic colour-filters, the gobo-wheel and the internal lenses should be cleaned
monthly.
To ensure a proper function of the gobo-wheel , we recommend lubrication in six month
intervals. The quantity of oil must not be excessive in order to avoid that oil runs out when
the gobo-wheel rotates.
There are no serviceable parts inside the device except for the lamp and the fuse.Please refer
to the instructions under "Fitting/Exchanging the lamp".Maintenance and service
operations are only to be carried out by authorized dealers.
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse
by a fuse of same type and rating.Before replacing the fuse, unplug mains lead.
Procedure:
1) Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the
housing (anti- clockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and fix it.
17
/