Using the analytical device Mini Identifier R-1234yf
16
6 Using the analytical device
6.1 Analysing refrigerant
A
➤ Plug in the connection cable (fig. 1 7, page 2) on the underside of the
analytical device (fig. 2 4, page 2).
➤ Connect the battery terminals to the car battery. Observe the correct
polarity.
✓ The LEDs on the analytical device flash one by one.
➤ Press the “Next” button (fig. 2 3, page 2).
✓ The analytical device begins its warm-up process.
After around 90 seconds, the “Calibrating” LED flashes (fig. 2 8,
page 2).
➤ Press the manual pump 5 times to clean the sensor of the device.
➤ Press the “Next” button (fig. 2 3, page 2).
✓ The “Calibrating” LED lights up for (fig. 2 8, page 2) 60 seconds.
➤ Connect the connection hose with the maintenance opening in the refrig-
erant container when the “Analysing” LED (fig. 2 7, page 2) flashes.
➤ Press the “Next” button (fig. 2 3, page 2).
✓ During the analysis, the “Analysing” LED (fig. 2 7, page 2) lights up for
approx. 45 seconds.
After analysis, the “Pass” (fig. 2 1, page 2) or “Fail” LED (fig. 2 2,
page 2) lights up (see chapter “Measurement results” on page 17).
➤ Remove the connection hose from the maintenance opening of the refrig-
erant container.
➤ Press the “Next” button (fig. 2 3, page 2).
NOTICE!
Before use, make sure the filter and hose are free from oil to
ensure the device is protected against oil and soiling. If this is
not the case, replace it.
Switch off the ignition and, if applicable, the vehicle's air con-
ditioning system before using the analytical device and let the
vehicle rest for 3 minutes. If the input pressure is too high, the
analytical device can be damaged.