Sloan Valve 3396076 Installation guide

Type
Installation guide

This manual is also suitable for

Sloan Valve 3396076 is a vacuum breaker trap primer designed to provide a constant water seal in a floor drain, preventing sewer gases from escaping into the air. It is suitable for use with Sloan Royal and Regal flushometers, and features a high back pressure vacuum breaker. The installation process involves connecting the vacuum breaker to the floor drain and to the flushometer, and then connecting a flexible tube to the wall flange.

Sloan Valve 3396076 is a vacuum breaker trap primer designed to provide a constant water seal in a floor drain, preventing sewer gases from escaping into the air. It is suitable for use with Sloan Royal and Regal flushometers, and features a high back pressure vacuum breaker. The installation process involves connecting the vacuum breaker to the floor drain and to the flushometer, and then connecting a flexible tube to the wall flange.

Code No. 0816188 – Rev. 4 (08/12)
ROYAL FLUSHOMETER MODELS
(Features High Back Pressure Vacuum
Breaker)
• VBF-72-A1
• VBF-73-A1with2”(50mm)Offset
REGAL FLUSHOMETER MODELS
• VBF-72-A2
• VBF-73-A2with2”(50mm)Offset
The Sloan vacuum breaker trap primer provides a constant
water seal in a floor drain. Each time the flushometer is
activated, a small amount of water is diverted to the floor
drain to maintain the water seal. This seal prevents
objectionable sewer gases from escaping into the air.
Perform the following functions using the rough-in guides illustrated in Figures A and B:
• Installflushometerfollowingtheinstructionsincludedwiththevalve.UsetheseinstructionstoreplaceONLYthe
instructions for a Vacuum Breaker Flush Connection.
• Installpipingfromconnectiononthefloordraintoadesiredlocationonthewall(determinedbyinstaller).(Sloan
doesnotsupplythepipingforthisconnection.)
Note:Besurethatapproximately1”(25mm)ofa½”(13mm)NPTmalepipeprotrudesfromthewall.
INSTALLATION INSTRUCTIONS VACUUM BREAKER
TRAP PRIMER
PRIOR TO INSTALLATION
TOOLS REQUIRED FOR INSTALLATION
INSTALLATION
TheseinstallationinstructionsreplaceONLYthestandardstepforaVacuumBreakerFlushConnectionInstallation.
• SmoothjawedspudwrenchorSloanA-50“Super-Wrench™”forcouplings
• TubeBender
• TubeCutter(ifnecessary)
• Threadsealant
LIMITED WARRANTY
Unlessotherwisenoted,SloanValveCompanywarrantsthisproduct,manufacturedandsoldforcommercialorindustrialuses,
tobefreefromdefectsinmaterialandworkmanshipforaperiodofthree(3)years(one(1)yearforspecialfinishes,SFfaucets,
PWTelectronicsand30daysforPWTsoftware)fromdateoffirstpurchase.Duringthisperiod,SloanValveCompanywill,atits
option,repair,replace,orrefundthepurchasepriceofanyproductwhichfailstoconformwiththiswarrantyundernormaluse
andservice.Thisshallbethesoleandexclusiveremedyunderthiswarranty.ProductsmustbereturnedtoSloanValveCom-
pany,atcustomer’scost.Noclaimswillbeallowedforlabor,transportationorothercosts.Thiswarrantyextendsonlytopersons
ororganizationswhopurchaseSloanValveCompany’sproductsdirectlyfromSloanValveCompanyforpurposeofresale.This
warrantydoesnotcoverthelifeofthebatteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS
SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
VBF-73-AWITH2”(50mm)
OFFSETAVAILABLEFORMODELS115
AND116ONLY.(FORUSEWITHGRAB
BARSINCLUDEDASPARTOFTHE
INSTALLATION.)
Figure A
CENTERLINE
OFFIXTURE
4¾”(121mm)
1”I.P.S.
SUPPLY
(DN25mm)
“C”
FIN.
FLOOR
FIN.
WALL
“B”
“A”
“C”
GRAB
BAR
2¼”MIN.
(57mm)
2”
(51mm)
“B”
“A”
4¼”MIN.
(108 mm)
Table1
“L” “A” “B” “C”
ForRoyalorRegal LengthofVacuum Centerlineof Centerlineof
FlushometerModel BreakerFlush SupplytoTopof SupplytoTrap CriticalLinetoTrap
Connection Bowl PrimerOutlet PrimerOutlet
110/111‡ 8½”(216mm) 11½”(292mm) 7”(178mm) 2¼”(57mm)
113/113-1.6 13”(330mm) 16”(406mm) 11”(280mm) 6¼”(159mm)
115/115-1.6 21”(533mm) 24”(610mm) 11”(280mm) 6¼”(159mm)
116/116-1.6 24”(610mm) 27”(696mm) 11”(280mm) 6¼”(159mm)
VBF-73-AWith2”(50mm)Offset
115/115-1.6 22½”(572mm) 25”(635mm) 11”(280mm) 6¼”(159mm)
116/116-1.6 25½”(648mm) 28”(711mm) 11”(280mm) 6¼”(159mm)
RefertoFigureAfordimensions“A,”“B”and“C.”RefertoFigureBfordimensions“L”and“C.”
ConsultlocalcodesforapprovaloftheuseoftheVBF-72trapprimerwithflushometermodels110/111.Some
codesrequireaminimumdistanceof6”(153mm)betweenthecriticallineofthevacuumbreakerandthetrap
primeroutlet.Inthesecases,specifymodels113,115or116.
Figure B
“L”
“C”
DISTANCETOBE
DETERMINEDBY
INSTALLER
CRITICALLINE
1½”(38mm)O.D.
VACUUMBREAKER
OUTLETTUBE
5/8”(16mm)
2¾”(70mm)
ELBOW
Insertthesmallerendoftheblackplasticwaterdeflectorintothethreadedendoftheelbowfitting.Theflatendofthe
elbow fitting will face outward from the vacuum breaker.
Placeseveraldropsofthreadsealantonthethreadsoftheelbowfitting.Inserttheelbowfittingandwaterdeflectorinto
thethreadedholeofthevacuumbreakertube.Screwthefittingintoplace.DONOTovertightenthisconnection.The
final position of the elbow should allow water flow from the vacuum breaker in a downward direction.
Figure1
Figure2
Figure3
Slidethespudcoupling,nylonslipgasket,
rubber gasket and spud flange (all supplied with
a standard flushometer vacuum breaker) over the
vacuum breaker tube and insert the tube into the
fixture spud. Tighten the spud coupling onto the
fixturespudbyhand.
VACUUMBREAKER
OUTLETTUBE
WATERDEFLECTOR
¼”I.P.S.
ELBOWFITTING
INSTALL
FITTING
INTHIS
RANGE
90°
1½”
(38mm)
WATER
DEFLECTOR
CENTERLINE
OFTRAP
PRIMER
WATER
FLOW
VACUUMBREAKER
OUTLETTUBE
ELBOWFITTING
WALLFLANGE
½”(13mm)NPTMALEPIPE
FORTRAPPRIMEROUTLET
½”(13mm)NPT
FEMALETUBEFITTING
1”
(25mm)
TO
TRAP
FINISHEDWALL
VACUUM
BREAKERTUBE
RUBBER
GASKET
SPUD
FLANGE
SPUD
COUPLING
NYLONSLIP
GASKET
1-INSTALLWATERDEFLECTORANDELBOW(FIG.1)
2-INSTALLWALLFLANGE(FIG.2)
3-INSTALLVACUUMBREAKERFLUSHCONNECTION
(FIG.3)
Placewallflangeoverthe½”(13mm)NPTmalepipeusedasthetrapprimeroutlet.Pushwallflangeuntilitisflush
againstthewall.Connectthe½”(13mm)NPTfemaletubefittingtothepipe.Thefittingwillhelpkeepthewallflange
in position.
DONOTuseabrasiveorchemicalcleanerstocleanflushometers,theymaydullthelusterandattackthefinish.Use
ONLYsoapandwater,andthenwipedrywithacleantowelorcloth.Whencleaning,protecttheexposedflushometer
fromanysplatteringofcleaner.Acidsandcleaningfluidscandiscolororremovechromeplating.
Whenfurtherassistanceisrequired,please
contact Sloan Technical Support at:
1-888-SLOAN-14(1-888-756-2614).
ManufacturedintheU.S.A.bySloanValveCompanyunderoneormoreofthe
followingpatents:5,373,592;5,564,460.OtherPatentsPending:Permex
®
.
Prior to inserting the flex tube into the elbow fitting, ensure
that the restrictor washer has been inserted into the elbow
fitting. The restrictor washer prevents too much water from
beingdivertedawayfromthebowl.Thishelpsensure
optimal bowl performance, even when used with 1.28 gpf
(4.8Lpf)High-EfficiencyToilets.
Usethe3/8”(9mm)diameterflextubingtoconnectthe
bottom of the elbow fitting with the restriction washer to the
tubefittingatthewallflange.Sloanprovidesa12”(305
mm) length of flex tubing. Cut tubing to appropriate length.
Tighten compression fittings at both ends of the flex tubing.
Complete the valve installation according to the installation
instructionsincludedwithyourSloanflushometer.
Figure4
SLOANHEADQUARTERS•10500SEYMOURAVENUE•FRANKLINPARK,IL60131
Phone:1-800-9-VALVE-9or1-847-671-4300•Fax:1-800-447-8329or1-847-671-4380•http://www.sloanvalve.com
©2012SloanValveCompanyCodeNo.0816188–Rev.4(08/12)
1A
2A
1B
8
3
10A
10B
7
9
4
5
6
1A
2B
1B
VACUUM
BREAKER
OUTLET
TUBE
ELBOW
FITTING
RESTRICTION
WASHER
½”(13mm)NPT
FEMALETUBE
FITTING
3/8”O.D.x12”
(9mmx305mm)
FLEXTUBING
4-INSTALLFLEXIBLETUBING(FIG.4)
CARE AND CLEANING
PARTS LIST
Item No. Part No. Description
1A V-579 VacuumBreakerCouplingforRoyalflushometers
1B V-553-A VacuumBreakerCouplingAssemblyforRegalflushometers
2A VBF-2 1½”(38mm)x“L”VacuumBreakerOutletTube(seeTable1forlength)
2B VBF-4 1½”(38mm)x“L”VacuumBreakerOutletTubewith2”(50mm)Offset
(see Table 1 for length)
3 F-75-AA AssemblyKitforTrapPrimer
4 F-7 WallFlange
5 F-73-A TubingFitting
6 F-75-A ElbowCompressionFitting
7 F-76 3/8”(9mm)x12”(305mm)FlexibleTubing
8 F-88 WaterDeflector
9 VBF-9 RestrictorWasher
10A V-651-A HighBackPressureVacuumBreakerRepairKit(standardwithRoyalflushometers)
10B V-551-A VacuumBreakerRepairKit(standardwithRegalflushometers)
The information contained in this document is subject to change without notice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Sloan Valve 3396076 Installation guide

Type
Installation guide
This manual is also suitable for

Sloan Valve 3396076 is a vacuum breaker trap primer designed to provide a constant water seal in a floor drain, preventing sewer gases from escaping into the air. It is suitable for use with Sloan Royal and Regal flushometers, and features a high back pressure vacuum breaker. The installation process involves connecting the vacuum breaker to the floor drain and to the flushometer, and then connecting a flexible tube to the wall flange.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI