Prolitec Air-Q 1100 User manual

  • Hello! I am an AI chatbot trained to assist you with the Prolitec Air-Q 1100 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Page1of18
AirQ1100
UserGuide
Rev1.05/13/09
©2009,ProlitecInc.
Air-Q 1100 User Guide Page2of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
AirQ1100
UserGuide
(Rev1.05/13/09)
©2009ProlitecInc.
I. IntroductiontoAirQ1100............................................................................... 1
A. ApplicationsandUses
1. AmbientScenting
2. OdorControl
II.SafetyPrecautions........................................................................................... 3
A. AppliancePrecautions
B. FragrancePrecautions
III.ApplianceandControls ................................................................................... 4
IV. GeneralMaintenance....................................................................................... 5
A. ChangingtheCartridge
B. Oringreplacement
C. BatteryReplacement
V. CommissioningAir
Q1100.............................................................................. 7
A. UnitProgramming
B. SettingScentIntensity
VI. Installation........................................................................................................ 9
A. PreInstallationChecklist
B. InstallationKit
C. AppliancePositioning
D. ApplianceInstallation
E. InjectorTubeInstallation
VII. Troubleshooting ............................................................................................. 15
VIII. GeneralCareandCustomerSupportContacts ............................................ 17
IX. Specifications.................................................................................................. 18
Page1of18
I.IntroductiontoAirQ1100
TheAirQ1100applianceisanairtreatmentsystemforinteriorspacesservedbyaductedHVACair
handlingsystem(“HVAC”).TheAirQ1100deliversafragranceorairtreatmentagent(“Agents”)
intotheairflowoftheHVACsystemeitherthroughthecentralfanunit(CFU)orat
suitable
locationsinthebranchedductwork.Itisdesignedforpermanentinstallationontheoutside or
insideoftheCFU.
TheAirQ1100ismanagedbyanonboardcomputerthatisfullyprogrammableforspacesizes
from1,000to250,000cubicfeetperapplianceandoneormore
intensitylevelsinthesameday.
MultipleappliancescanworktogetheronthesameormultipleCFUstotreattheairinthesame
spacesservedbytheHVAC.Inthisway,thereisnolimitationonthesizeofthespacethatcanbe
servedbyAirQ1100.
AirQ1100requireslittletonomaintenanceexceptperiodiccleaningforappearance.Installations
ofAirQ1100aredesignedsothattheconsumptionoftheconsumableCartridgesofAgent
(“Cartridges”)requiresreplacementnomorefrequentlythanonceamonth.

TypicalAirQ1100applicationsincludeairtreatmentforodorremediation,
scentbrandingand
ambientscentinginpublicspacessuchascasinos,malls,hotels,theaters,ballrooms,convention
centers,hospitals,andrestrooms.
TheAirQ1100generatesultrafine,ultralightdropletsapproximately500nanometersin
diameter.Bycomparison,adropletfromapressurizedaerosolis50microns(50000nanometers)in
diameteror166timeslargerthananAirQ1100droplet.Intermsofweightandvolumeofliquid,
thecomparisonisevenmoredramatic.A50micronaerosoldropletis4.6milliontimesheavier
thana300nanometerAirQdroplet.
1
ThistinyAirQdropletoffersmanyperformancebenefits
overaconventionalaerosolincluding:completelyuniformdistributionofthetreatmentagent;100
timesmoreexposedsurfaceareaallowinguseofmuchlessairtreatmentagentpercubicfoot;and
theabsenceofanyliquiddepositsonsurfacessuchasthe
interiorsurfacesinaHVACsystem.
TheAirQ1100Guideispackedwithimportantinformationthatwillhelptheusers,installersand
serviceengineersoptimizetheperformanceofthismodernairtreatmentsystem.Weencourage
youtoreaditcarefully.
1
This is calculated using the formula for the volume of a sphere
where V is the volume or weight and r is
the radius of the droplet.
Air-Q 1100 User Guide Page2of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
A. ApplicationsandUses:
AirQ1100isusedwithproprietaryfragrancesandodorremediationagents(“Agents”)toenhance
indoorairqualitybyerasingodorsandintroducingscent.Thisisaccomplishedbyconvertingliquid
stateAgentsintoultrafinedropletsandinjectingthemintothemintotheHVACsystemtoblend
withtheairflow.Usedasdirected,theconcentrationofAgentintheairwillusuallybelessthan1
partpermillion(<1ppm).Thismeansthatforevery1,000,000moleculesofair,lessthan1
moleculeisairtreatmentAgent.TheAirQ1100’sdropletsareabout500nanometers
indiameter
(halfamicron).Adropletofthissizepresents10,000timesmoresurfaceareatotheairthanthe
sameamountofliquidina50micronaerosoldroplet.TheAirQdropletis1/1,000,000
th
theweight
ofanaerosoldroplet.Thismeansthedropletsbehaveasiftheyweredry,donotleaveanyresidue
onthebladesorinteriorductsurfacesandcreatescenteffectwithconcentrationssolowitus
unlikelytotriggerallergicresponse.
TherearetwobasicapplicationsforAirQ1100:ambientscentingandodorremediation.TheAirQ
1100deliverysystemandProlitec’sproprietaryairtreatmentchemistrycandobothatthesame
timeoreitheronealone.
1. AmbientScenting
AmbientScentingistheuseoftheAirQ1100todeliverascenttocreateamoodor
ambience,associateascentwithabrand,enhanceavisualthemeorsimplymakeaspace
morepleasantforitsoccupants.
2. OdorControl
OdorControlistheuseofAirQ1100andspecialairtreatmentchemistrytoneutralize
odorsbyblockingcertainmalodorsthusallowingtheintroductionofverysmallquantities
offragranceintotheair.Normalairfreshenerssimplyusefragrancetodouseamalodor.
Air-Q 1100 User Guide Page3of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
II.SafetyPrecautions
A. AirQ1100AppliancePrecautions:
Theappliancemustbeoperatedinanuprightorverticalpositionandfirmlyattachedtoa
verticalsurfacesuchasawalloraduct.
TheapplianceshouldNOTbeusedwiththedoorintheopenposition.Thedoorisopened
onlytoperformacartridgeorprogramchange.
NEVERputyournosetotheoutputofAirQ.Within12inchesoftheoutput,thefragranceis
highlyconcentrated.Theimproperinhalationofhighconcentrationsoffragrance maycause
irritationincludingwateryeyes,headache,coughandupperrespiratorydiscomfort.
Theapplianceisbuilttobepluggedintoan110VACor220VACpoweroutlet.TheULandCE
compliantpowersupplyconvertspowerto12VDCtopowertheappliance.
Unplugbeforecleaning.
B. AirQCartridgePrecautions
ReadtheProductSafetyInformationSheetandtheMaterialSafetyDataSheetenclosed
providedwitheachshipmentofCartridges.Insurethattheseinformationsheetsare
availableforreviewbyemployees
UselatexglovestohandleaCartridgetoavoidtheliquidgettingonhands.TheAgentsare
formulatedsoastonotbeharmfulincontactwiththeskin,buttheconcentratednatureof
theagentsmakesthescentdifficulttoremovefromhandsandskin.
WashyourhandsafterallcontactwithCartridgesorfragranceandairtreatmentagents.
CartridgesmustbeprovidedbyandcontainAirTreatmentAgentformulationswhichhave
beencertifiedbyProlitec.
WhileAirQAirTreatmentAgentsdonotcontainingredientsdeemedharmfultotheskin,if
thereisskincontact,washwithsoapandwater.Ifthereiscontactwiththeeyes,irrigate
theeyewithfreshwaterfor5minutes.Ifthereisanyeyeirritation,consultaphysician
immediately.
Air-Q 1100 User Guide Page4of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
III.ApplianceandControls
AirQ1100





Cartridge
InjectorHose
ControlDisplay
ControlButtons
PowerCord
ProgramSelector
BatteryTab
AirNozzle
HoseConnector
HoseClamp
AirFilter
Air-Q 1100 User Guide Page5of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
IV.GeneralMaintenance
A. ChangingtheCartridge
Unlatchandopenthedoortoaccessthecartridge:Thedoorshouldbeopenedonlyto
performacartridgeorprogrammingchange.Wheninuse,thedoormustbeclosed.
1. Removeairnozzle(locatedonthesideofthe cartridgehead)byrotating90degreesand
pullingtowardsyou.(SeePicture#1)
2. DetachInjectorhoseandhoseconnectorfromthecartridgeoutputport(locatedonthe
topofthecartridgehead).Thisisdonebyunscrewingthehoseconnectorfromthe
cartridgeoutputportandpullingout.
3. Removecartridgefromapplianceenclosure.
4. Installnewcartridge,placeandtightenhoseconnectorfirmlyoncartridgeoutputport.
5. Insertairnozzleandrotatethehandle90degreesuntilsecured(bystemretainingtab
oncartridgehead).(SeePicture#2)
6. Turnapplianceon.Verifythattheplumeisnotescapinginsidetheapplianceandthatall
connectionsaretight.Closethedoorwhencomplete.
B. OringReplacementevery6monthsorasneeded:
Replacetheairnozzle3orings(Partnumber10208) ifworedownorswollen.Apartiallyfull
cartridgemayindicateanairleakbetweentheairnozzleandthecartridge,reducingplume
output.Replaceas
neededand/oreverysixmonthsforpreventativemaintenance.
IfthereisanyAgentthatleaksduringthecartridgeinstallation,cleanitcarefullywitha
papertowelwithsomeethanoloranotheralcohol.
C. AirFilterevery6monthsorasneeded.
Replaceairfilter(partnumber10417) ifdirty.Ifanydusthasgatheredinsidetheunit,
removeitwithadamppapertowel.
Picture1 Picture2
Cartridge
RetainingTab
Air-Q 1100 User Guide Page6of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
D. BatteryReplacementapprox.every2years:
(requires3VoltCR2032LithiumBattery,partnumber8111):
1. Unlatchandopenthedoortoaccesstheenclosure.
2. Usingapairoftweezersorneedlenosepliers,remove
batteryfromthecenteropeningoftheovalgrommet.The
grommetislocatedonthefrontofthebluebracketbelowthe
operatingbuttons.
3. InsertthenewCR2032battery.Thepositivesideofthe
batteryshouldfaceyourrightwhilelookingatthefrontofthe
appliance.Thebatterywillhavea+ormarkingonaside.
Air-Q 1100 User Guide Page7of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
V.CommissioningtheAirQ1100
A‐UnitProgramming
1. Openthedoorandunlockifneeded.
2. TurnonthepowerbypressingtheON/OFFbuttonintheupperleftcornerofthecontrolpanel.
(MakesuretheapplianceispluggedintotheACpoweroutlet.)Thepowerbuttonwilllightblue
3. SettingtheClock.
TurnthedialtoSetClock.Thetimewillblink.
Adjustthetimeforwardorbackwardusingthe+/–buttonsontherightside ofthecontrol
panel.AMorPMisindicatedonthelowerrightsideofthetimedigits.Hold+tofastforward.
4. Usingthe24/7Mode.
IfyouwanttheAir/Q™1100toruncontinuously7daysaweek,24hoursadayturn
thedialto24/7.Ifnot,skiptoStep5.
5. SettingspecificStart/StopTimes.
TurnthedialtoStart.
Adjusttheclocktothetimeyouwanttheappliancetostarteachdayusingthe+/–keys.
TurnthedialtoStop.
Adjusttheclocktothetimeyouwanttheappliancetostopeachdayusingthe+/–keys.
6. UsingtheProgramMode
TurnthedialtoProgramtooperatewiththespecifiedstart/stoptimes.
7. UsingtheProgramOverride
Pressthebuttoninthebottomleftcornertooperatetheapplianceoutsidethespecified
start/stoptimes.
Eachtimethebuttonispressed,anotherhourisaddedupto12hours.
Air-Q 1100 User Guide Page8of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
B‐SettingScentIntensity
1. ConsulttheSettingsTable,whichprovidesasettingforthesize incubic feet(lengthxwidthx
ceilingheight)ofthespaceyouaretreating.Usetheindicatedintensitysettingasastarting
pointfromwhichyoucanincreaseordecreasetotaste.Numberoffreshairchangesperhour
anduserpreferencewillaffectsettings.
SettingsTable:
Output Level Range
Settings
Space to be treated
in Cubic Feet
Space to be treated
in Cubic Meters
1 thru 5 3,000-15,000 85-425
6 thru 10 15,000-29,000 425-820
11 thru 15 29,000-48,000 820-1360
16 thru 20 48,000-68,000 1360-1,900
21 thru 25 68,000-91,000 1,900-2,600
26 thru 30 91,000-117,000 2,600-3,300
31 thru 35 117,000-146,000 3,300-4,100
36 thru 40 146,000-177,000 4,100-5,000
41thru 45 177,000-214,000 5,000-6,000
46 thru 50 214,000-250,000 6,000-7,100
2. Pressthepowerbuttonon.TurnthedialtoProgramandsettheintensitylevelwiththe+/–
keys.Youwillseethelevelnumbers(1to50)ontherightsideofthescreen.
Hint:Therearemanyvariablesinvolvedinfindingtherightsettingsforscent.Feelfreetoadjustto
taste.DonotsetscentleveltomaximumsettingorhigherthanrecommendedintheSettingTable,
butstartfromrecommendedlowestlevelandincreaseprogressivelyforoptimumresults.
TheLastStep
1. Setthedialtoeither24/7orProgramifyouhaveprogrammedastart/stoptime.
2. Makesurethepowerison.Thebluelightwillshowthroughthebutton.
3. Closeandlockthedoor,storingthekeyinaknownplace.
Air-Q 1100 User Guide Page9of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
VI.Installation
A. PreinstallationChecklist
Thischecklistshouldbecompletedbeforetheinstalldate.
1. Confirmtheareatobetargetedforairtreatment
2. DeterminetheAirHandlingUnitorductthatservesthetargetarea.
3. MakesuretheAHUdoesnotuseanopengasflame.
4. Findand
marktheoptimalinsertionpointfortheInjectorTube.(SeesectionC:Appliance
Positioning”)
5. Findandmarktheexactlocationforplacementoftheappliance(SeesectionC:Appliance
Positioning”)
6. Notethedistancebetweentheinsertionpointandtheproposedappliancelocation.(NEVER
MORETHAN6
FEET)andthereshouldNEVERbeaLOWPOINTinthehoserun.
7. Determineandmarkthelocationforthe110or220VACpoweroutlet.(NEVERDIRECTLY
BELOWTHEappliance)
B.InstallationKit(photosPage10)
One(1)AirQ1100appliance(notpictured)
One(1)ProlitecInjectorTube(a)
Three(3)Feet3/8
th
ID,½ODInjectorhose(b)
One(1)hoseconnectorassembly(c)
One(1)hoseclamp(d)
Seven(7)#10selftappingsheetmetalscrewsforsecuringtheapplianceandinjectortubeon
sheetmetal.(e)
1sparesetof3oringsfortheairthenozzle
(f)
Air-Q 1100 User Guide Page10of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
Optional:Onehosequickdisconnectfittingwith3feethoseextensionwithhoseclamps,to
increasedistanceupto6feet(seenote#6above)
(a)
(b)
(c) (d)
(e)
(f)
Air-Q 1100 User Guide Page11of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
C. AppliancePositioning
Itisimportanttofindaninsertionpointwheretheplumeoutputwillbesmoothlydrawninto
andmixedwiththeairflow.ThisusuallymeansthosepartsoftheAHUwherethestatic
pressureisnegative.Ideallocationsinclude:
BeforethesupplyfanwithinjectionthroughthewalloftheAHU.Positioningimmediately
beforethefanandafterthecoilsifpossibleorinthemixedairchamber.
BehindtheblowerwiththewholeappliancemountedinsidetheAHUinthemixedair
chamber.
OutsidetheAHUintheSupplyairduct.
BestpracticewheninstallinginanAHUistoplacetheinjectortubeaftertheheatingand
coolingcoils.Ifthisisnotpossible,thePlumeoutputcanpassoverhotwater,steam,chilled
water,andDXcoils.

Opengasflamesshouldabsolutelybeavoided.Ifinstallationmustbeovergasheatedcoilsor
opengasflames,contactProlitecTechnicalSupport.
ThebestlocationfortheApplianceisbelowtheinjectortube(SeeFigure1).Theinjectorhose
shouldberunupwardasshortadistanceaspossibleandNEVERMORETHAN6FEETOR180
CENTIMETERS.Ifanupwardinjectorhoserunisnotpossible,careshouldbetakensupportthe
hosetopreventsaggingoranylowspotintheruntoavoidanypossibilityofcondensationand
liquidcollectionwhichwillblocktheplumeoutput.Theinjectorhoseispronetostretching,so
supportpointsshouldbeplacedevery5to6inchesonhorizontalruns.Givethehoseaslight
upwardslantalongitsrun(SeeFigure2).Thehosemustnotberunhorizontally.Astrongtape
(suchasVenturetape)maybeusedtosupportshortruns.ThehosemayberunthroughPVC
pipeforlongerdistances.
Figure1
InjectorTube
PowerJunctionbox
Injectorhose
AirQ1100
Air-Q 1100 User Guide Page12of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
D.ApplianceInstallation
1. TheAPPLIANCEiswallmounted.PlacetheAPPLIANCEontothedesiredlocationonthewall
orAHUandensurethatitislevel.
2. FastentheAPPLIANCEtothewallorAHUusingthenecessary screws.
3. ConnectthepowercordtoajunctionboxorattachanACplugtothecordandconnecttoa
nearbyoutlet.
4. Opentheenclosuredoorandunscrewthealuminumcapofthewaterproofcollarlocated
ontopoftheapplianceenclosure.Removeandsetasidethegrommet(seephotoonPage
13).
5. Assemblehoseandhoseconnectortogether(seephotobelow).Besuretoleave
approximately1/8ofaninchclearancebetweenthetopofthecartridgehoseconnector
andtheendofthehose.Thensecurewithclamp,ensuringthatthehoseconnectorisstill
freetorotate.
AQ
1100
DUCT or
PLENUM
DIP
INCORRECT
AQ
1100
DUCT or
PLENUM
CORRECT
Figure 2
Clamp
Leave 1/8"
clearance
Hose
Connecto
r
Air-Q 1100 User Guide Page13of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
6. Fromtheinsideoftheenclosure,slidehoseassemblyupwardthroughtothewaterproof
collar.
7. LubetheinsideofthegrommetifneededtoallowtheInjectorhosetoeasilyslidethrough.
Leaveapproximately2inchesofhoselengthinsidetheappliancetoprovideenoughplay
whenreplacingthecartridge.Tightenaluminumcapofwaterproofcollartoensurea
watertightseal.
8. Usetheoptional quickdisconnectfitting(SeephotoonPage10)toaddahoseextensionif
needed.
Waterproof
Colla
r
Air-Q 1100 User Guide Page14of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
E.InjectorTubeInstallation
TheinjectortubeisinstalleddirectlyintotheAHUortheductwork.Itsorientationcanbeadjusted
relativetotheairflow.
Forinstallationsintothenegative/suctionsideoftheAHUfan,orientthetubewiththe
elbowpointedupwards(SeeFigure2),sothatanyplumecondensationwillsipbackin
thetube.
Forinstallationsafterthesupplyfan,suchasinasupplyduct,itisnecessarytoconfigure
andorienttheInjectorTubetoobtainagoodaspirationoftheoutputintotheair
stream.Theinjectortubeshouldbepointedinthedirectionoftheairflowandinclined
45
o
upwardapproximately.Turbulenceintheairflowcanpreventevenaspirationofthe
plume.Itisbesttoplacethetubeinastraightsectionofduct,andfarawayfromany
turns,branches,orcrosssectionchangesaspractical,andnotimmediatelyafterthe
supplyfan.
1. Attheinsertionpoint,drillaholeusinga½”drill bit.
2. InserttheInjectorTubethroughthe hole.
3. FindanorientationoftheinjectorTubethatappearstoproduceagooddrawofairinto
theendofthebarb.
4. Fastentheflangeusingthethree#10sheetmetalscrews
5. TurntheAPPLIANCEonandverifythataplumeisproduced.
6. BeforeattachingtheInjectorhosetotheinjector,verifythattheplumecanfloweasily
throughtheinjector.Thiscanbedonebyplacingtheendofthehose½inchawayfrom
theinjectorandverifyingthattheplumeisbeingdrawnin(aflashlightwillmakethe
plumeeasiertosee).Iftheplumedoesnotriseintothehose,adjusttheorientationof
theInjectorTubeuntilaspirationisachieved.
7. AttachtheInjectorhoseontothehosebarboftheInjectorTube.
For
CartridgeInstallationSee"ChangingtheCartridge"onPage5.
Air-Q 1100 User Guide Page15of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
VII.Troubleshooting
Condition Causes Solutions
Powerlightoff. TheApplianceisnot
pluggedinortheplug
hasnopower
Makesurethepowerconnectionisoperational.
Verifythatthepowerbuttonlightisbluewhen
pressed.
Unitdoesnotstart
automaticallyafterapower
interruption
Backupbatterynot
operational
Verifytheprotectiveyellowbatterytabhas
beenremoved.
Verifythebatteryispositionedwiththepositive
sidefacingtheright.
Replacethebackupbattery.
Thefragrancecannotbe
detectedwhencominginto
thetreatedareafroman
untreatedarea.
Theoutputrateistoo
loworthereisan
insufficientnumberof
appliancesservingthe
space
TheORingsonthestem
thatfitsintothehead
maybewornoutand
causingan
airleak.
Increasetheoutputratebyoneortwosettings
andevaluatedetectionin30minutes.Repeatas
needed.IfconsumptionrequiresCartridge
changemorefrequentlythaneachmonth,
installanadditionalappliance.
ReplacetheORingsbyremovingthewornone
withapointytoolandrollingon
thenewones
Fragranceintensityis
strongerthanjust
detectable.
Theoutputrateistoo
high.
Lowertheoutputrateinincrementsofoneor
twosettingsordowntothestartingrates
suggestedintheroomsizechart.
Thepowerlightisonbut
thethereisnooutputor
youcannothearthe
compressorinthe
appliance.
Youareinan“OFF”
periodintheTimercycle.
Simplywaitafewminutesfortheapplianceto
cycleon.Iftherealproblemisthatthescent
cannotbe
detected,increasetheoutputrateas
instructedabove.
Thepowerlightisonand
thecompressorcanbe
heardbutnofragrance
detected.
Theoutputtubemaybe
blocked.
Theairintakemaybe
blocked.
Removethehosefromtheoutputtubeleaving
theCartridgeinplaceintheappliance.Turnthe
applianceonsoyoucanhearthecompressor.
Useaflashlighttoobservethetopoftheoutput
headforaplumeofdroplets.Ifyoucanseethe
plumethentheblockagemaybeinthehoseor
theinjectortubeintotheHVAC.Checkthese.If
thereisno
plumesomethingisblockingthe
outputtube.Checkandremoveit.
Anothermethodforclearingobstructionsis,
whiletheappliancecompressorisrunning,
blocktheoutputtubewithafingerfor2or3
secondsandthenopenit.Byremovingyour
finger.
Air-Q 1100 User Guide Page16of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
TheORingsonthestem
thatfitsintothehead
maybewornoutand
causinganairleak
ReplacetheORingsbyremovingthewornone
withapointytoolandrollingonthenewones
Youdetectthefragrance
whenenteringtheroombut
afterawhileyounolonger
noticeit.
Thisiscalledolfactory
adaptationandis
normal.
Leavetheareafor5to10minutes.Comeback
inside,youwillsmellthefragranceonceagain.
Donothesitatetorepeatthisprocessevery
timethatyoudoubtthepresenceofthe
fragranceinthearea.
Air-Q 1100 User Guide Page17of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
VIII.GeneralCareandCustomerSupportContacts
DonotinstallorstoreAirQ1100inplaceswheretheambienttemperaturemayfallbelow
0degreesCelsius(32degreesFahrenheit)orriseabove54degreesCelsius(130degrees
Fahrenheit).(Ifoperatingconditionsmustbeoutsidetheseranges,contactProlitecSafety
andSupportHotlineat888.615.9282).
DonotdropAirQ1100onthefloor.Donotdropitinorpositionitnearanopenbasinof
water.
Donotpaintorotherwisetrytoalterthecoloroftheoutercover.
AlwayskeepthelidsonCartridgeswhenstoredoutsideoftheAirQ1100.
DonotoperateAirQ1100inverydustyareasthatmaycausetheairintaketoclog.
PleasecallProlitecCustomerServiceat866.387.4333forinstructionsonreturnshipping
instructionsorquestions.
Air-Q 1100 User Guide Page18of18
(rev 1.0 5/13/09)
© Copyright 2009 Prolitec Inc
IX.Specifications
TechnicalCharacteristics 
ReferenceAirQ1100:ModelAQ1100
Type1headnebulizerintegratedwithcartridge
Diameterofparticles300nmtomicron
PowerInput 
Input100240VACat0.6A
Frequency50/60Hz
ProtectionSwitchingpowersupply
InternalPower12VDCat1.5A
Backupbattery
Lithium3V,#CR2032
Performance 
Upto250,000cu.feet(7,080cumeters)subjecttoairflowconditions
Control
Programmablestart&stoptimes
Programmableoutput0to50

Dimensions 
HeightXWidthXDepth 151/2”X133/8”X66/8”(39.4cmX34.0cmX17.2cm)
Weightwith
fullcontainer 13.7lb(6.2kg)
Cartridge 
Reservoir‐1250ml
Disposable/Recyclable
PatentedProlitecInc. ......... Multiplepatentspending
/