NXR AK3001 Installation guide

Category
Cookers
Type
Installation guide

This manual is also suitable for

Duro Corporation
Gas Range Manual for Installation,Care&Maintenance
AK3001 AK3605 AK4807
INSTALLATION INSTRUCTIONS
IMPORTANT
Keep appliance area clear and free from combustible materials,gasoline,and other
flammable vapors.
Gas Supply Requirements
Installation of this range must conform with local codes,or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1 / NFPA 54. In Canada,installation must
conform to the current natural Gas Installation /code,CAN 1-1.1-M81 and with local
codes where applicable.This range has been design-certified according to ANSI Z21.1-
2016/CSA 21.1-2016 latest edition.
A statement of the maximum gas supply pressure in accordance with the inlet pressure
rating of the gas appliance pressure regulator supplied.
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR LP GAS---14.0 IN.W.C.
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR NG --- 6 IN.W.C.
APPLIANCE REGULATOR IS SET AT 5.0 IN. W.C. OUTLET PRESSURE.
Do not obstruct the flow of combustion air into the range and ventilation air away from
the range.
Ventilation: it is recommended that the unit be operated with an oven head,vented
exhaust hood of sufficient size and capacity.
Before installing the range,you must locate and secure the included anti-tip bracket to the
wall for your range.
The use of cabinets for storage above the appliance may result in a potential
fire hazard.Combustible items may ignite;metallic items may become hot
and cause burns. If a cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects horizontally a minimum of
5" (12.7cm) beyond the bottom of the cabinets.
The appliance shall not be used for space heating.This information is based
on safety considerations.All openings in the wall behind the appliance and
in the floor under the appliance shall be sealed.
9
CAUTION
The range may be installed flush to the rear wall. You may install a non-
combustible material on the rear wall above the range and up to the vent hood.
It is not necessary to install non-combustible materials behind the range below
the counter top height.
The minimum distance from the side of the range above the counter top to
combustible sidewalls must be at least 10 inches.
INSTALLATION INSTRUCTIONS
Dimensions and Clearances
INSTALLATION INSTRUCTIONS
10
Heig
ht
39
4
5
30
27
3
4
depth
with door op
en
44
1
4
11
12
He
ight
39
4
5
d
e
pt
h
w
it
h
do
o
r
op
e
n
4
4
1
4
48
27
3
4
Dimensions and Clearances
13
INSTALLATION INSTRUCTIONS
The maximum depth of cabinets installed above cooking tops be 13 in(330mm) or a
great specified by the manufactures as tested by the certification agency.
14
Electric Power Supply Requirements
Your range must be electrically grounded in accordance with local codes or,in the
absence of local codes,in accordance with the National Electrical Code
(ANSI/NFPA 70, latest edition).In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or
local codes.A copy of this standard may be obtained from:National Fire Protection
Association,1 Batterymarch Park,Quincy,Massachusetts 02269-9101.
The power supply must be the correct polarity. Reverse polarity will result in
continuous sparking of the electrodes, even after flame ignition. If there is any
doubt as to whether the power supply has the correct polarity or grounded, have it
checked by a qualified electrician.
Use 120V,60Hz,and properly grounded branch circuit protected by a 15-amp or
20
-amp circuit breaker or time delay fuse.
Electrical Grounding Instructions:this indoor gas cooking appliance is
equipped with a three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-pronged
receptacle.
Do Not cut or removes the grounding prong from the plug.
Caution Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.Verify proper
operation after servicing.
15
Grounding
The power cord is equipped with a three-prong (grounding) plug which mates
with a standard three-prong grounding wall receptacle to minimize the
possibility of electrical shock hazard from the range.
All cord connected appliance shall include instructions relative to location of
the wall receptacle and a warning to the user to disconnect the electrical supply
before serving the appliance.
Where a standard two-prong wall receptacle is encountered,it is the
responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle. Do not cut or remove the
grounding prong from the power cord.
Connect Range to Gas Supply
Install a manual gas line shut-off valve in the gas line in an easily accessed
location outside the range in the gas piping external to the appliance for the
purpose of turning on or shutting off gas to the appliance.
Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of
regulator. On models equipped with standard twin burners, install the male
pipe thread end of the ½” flare union adapter to the ½” NPT internal thread at
inlet of pressure regulator.Use a wrench on the regulator fitting to avoid
damage.
Install male ½” or ¾” flare union adapter to the NPT internal thread of the
manual shut-off valve,taking care to secure the shut-off valve to keep it from
turning.
The gas supply pressure for checking the regulator setting is 6in (Natural Gas)
and 11inchLP gasconnect flexible gas line connector to the regulator on
the range.Position range to permit connection at the shut-off valve.
When all connections have been made,check that all range controls are in the
“off” position and turn on the main gas supply valve.
Leak testing of the appliance shall be conducted according to the
manufacture‟s instructions.Use some soap water (50% water and 50% soap) or
a leak detector at all joints and connections to check for leaks in the system.
Do not use a flame to check for gas leaks.
The appliance must be isolated from the building‟s gas supply piping system
by closing its individual manual shut-off valve during any pressure testing of
the gas supply piping system at test pressure equal to or less than ½ psig
(3.5kPa).
INSTALLATION INSTRUCTIONS
16
The bottom of the hood should be 30′min. to 36′′ above the counter top.This
would typically result in the bottom of the hood being 66′′ to 72′′ above the floor.
These dimensions provide safe and efficient operation of the hood.
After Installation:
Check ignition of cooktop burners.
Check the air shutter adjustment sharp blue flame,with no yellow tipping or
lifting flames.
Check ignition of oven burner.
Visually check tubular burner (oven burner) re-ignition to be sure both rows of
burner ports are relighting each time.
Check for gas leaks at all gas connections (using a gas detector,never a flame).
Check oven bake and convection bake function.
Hood/Composite Overlay Install
17
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

NXR AK3001 Installation guide

Category
Cookers
Type
Installation guide
This manual is also suitable for