Hunter Fan 59180 Owner's manual

Category
Household fans
Type
Owner's manual

Hunter Fan 59180 is a reliable device that provides comfort and performance in your home or office for many years. It is easy to install following the instructions provided in the manual and comes with all the necessary tools. It includes a standard downrod for ceilings that are 8-10 feet high, but you can also purchase a shorter or longer downrod depending on your needs. The fan has a 7 feet minimum blade to floor clearance and requires a mounting option from building structure or fan-rated outlet box that can support 70 lbs.

Hunter Fan 59180 is a reliable device that provides comfort and performance in your home or office for many years. It is easy to install following the instructions provided in the manual and comes with all the necessary tools. It includes a standard downrod for ceilings that are 8-10 feet high, but you can also purchase a shorter or longer downrod depending on your needs. The fan has a 7 feet minimum blade to floor clearance and requires a mounting option from building structure or fan-rated outlet box that can support 70 lbs.

www.HunterFan.com
1.888.830.1326
Table of Contents
Congratulations on purchasing
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or ofce for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
Blades Switch Housing
PAGE
15
PAGE
14
PAGE
16
PAGE
21
TroubleshootingLight Kit
?
?
?
18
PAGE
Operation, Maintenance
& Cleaning
PAGE
7
PAGE
10
PAGE
11
30 inches
7 feet
PAGE
2
What to Expect with
Your Installation
Ladder
PAGE
3
Tools Needed
Secondary Hanging
System
WiringDownrod
D
I
S
C
A
R
D
D
I
S
C
A
R
D
PAGE
5
Preparation
Mounting Options
PAGE
4
Canopy
PAGE
13
Ceiling Bracket
PAGE
6
1
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
2
1.888.830.1326
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
What to Expect with Your Installation
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
Assess ceiling angle
Must be able to
secure the fan to
building structure or
fan-rated outlet box
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg)
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch
location. If you cannot lock the circuit breakers in the off
position, securely fasten a prominent warning device, such as a
tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and if not
installed and used in accordance with the instructions may cause
harmful interference to radio communications.
This product may cause interference to radio equipment and
should not be installed near maritime safety communications
equipment, ships at sea, or other critical navigation or
communications equipment operating between 0.45-30 MHz.
This device complies with Part 18 of the FCC Rules.
76.2 cm /
30 in.
from blade tip
to nearest wall
or obstruction
2.15 m /
7 ft.
from bottom
edge of blade
to the oor
Select a downrod length
1
2
3
Standard Downrod
(included, pre-assembled)
for ceilings 2.4–3 meters /
8–10 feet high
Shorter Downrod
(included)
for fans installed close to ceiling
Longer Downrod
(sold separately)
for ceilings 3 meters / 10 feet or
higher
www.HunterFan.com
1.888.830.1326
Tools Needed
Ladder
Screwdrivers
Pliers Wire Strippers
If mounting to a support structure, you will also need these tools.
Power Drill
(optional)
.36 cm / 9/64 in.
Drill Bit
(optional)
3
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
4
1.888.830.1326
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Guide Touches
BOTH Ceiling & Wall
S
I
T
U
A
T
I
O
N
1
Guide Touches
Wall
but
NOT Ceiling
S
I
T
U
A
T
I
O
N
2
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
You need ONLY
a Longer
Downrod
*most common
If you have a at ceiling:
Hang your fan by a standard downrod (included).
Mounting Options
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
34
O
CEILING
WALL
OPTION
1
Standard
Mounting
OPTION
2
Angled
Mounting
2 3
SLIDE
toward ceiling
PLACE
against wall
1
FOLD
on dotted line
34°
Use the three steps below to determine if your ceiling angle is greater than 34°
Support
Structure
Ceiling
Outlet Box
(required)
Angled
Mounting
Style
Standard
Mounting
Style
Support
Structure
Ceiling
Outlet Box
(required)
www.HunterFan.com
1.888.830.1326
Preparation
D
I
S
C
A
R
D
D
I
S
C
A
R
D
Remove the shipping ring from
bottom of the motor housing by
unscrewing the ve screws. Discard
the shipping ring and the screws.
Do not discard the hardware bags or mix
parts from different bags. Make note of
the symbol printed on each hardware
bag. The symbols can be used to identify
the appropriate hardware for each step.
5
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Ceiling Bracket
Refer to warning w.1 on pg. 2
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
For angled ceilings, point
opening toward peak.
If you are unable to do this,
call Technical Support at
1-888-830-1326.
Make sure all four bumpers are
still attached.
Use wood screws
(included) when securing
to support structure with
approved electrical outlet
box. Drill 9/64” pilot holes
in support structure to aid
in securing ceiling bracket
with hardware found in
the hardware bag.
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
OFF
Turn Power
6
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Downrod
Slide
Slide
1 2 3 4 5
678910
Sold Separately
Included
Shorter
Downrod
for fans installed
close to ceiling
Option 1Option 2
Option 3
skip to next page
If you need a different downrod length follow these steps:
Steps 1–5 to remove standard downrod pipe
Steps 6–10 to reassemble with new pipe
Included
(pre-assembled)
Longer
Downrod
for angled ceilings
or ceilings 3 m /
10 ft. or higher
Standard
Downrod
for ceilings 2.4–3 m /
8–10 ft. high
7
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Downrod (continued)
KEEP!
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4–5 full turns) until it stops.
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
If the setscrew is not tightened
securely, the fan may fall.
K
E
E
P
!
The wires can be cut, but
leave at least 20 cm / 8 in.
extending from the top of
the downrod.
8 in.
3/8 in.
C
U
T
&
S
T
R
I
P
(not to scale)
.95 cm
3/8 in.
20 cm
8 in.
20 cm / 8 in.
.95 cm
3/8 in.
88
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Downrod (continued)
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
of the fan.
9
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Secondary Hanging System
Insert the looped end of the
braided cable through the ceiling
bracket and one of the holes in the
outlet box into the ceiling. Access
the support brace in the ceiling.
You may not be able to do this from
below the ceiling depending on
your installation site.
Drive the wood screw and
washer found in the bag
into the side of the support
brace that holds the outlet box.
Leave 3 mm (1/8 in.) of space
between the support brace
and the washer.
Wrap the braided cable around
the support brace once
creating a complete circle.
Hook the looped end of the
cable over the wood screw so
that the cable lies between the
washer and the support brace.
Tighten the loop and secure the
screw and washer all the way
down to the support brace. Coil
up the excess cable.
Outlet Box
Ceiling
Support
Brace
Braided
Cable
3 mm (1/8 in.)
10
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Wiring
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
11
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
F
R
O
M
C
E
I
L
I
N
G
F
R
O
M
C
E
I
L
I
N
G
B
R
A
C
K
E
T
green/yellow
stripe (grounding)
green/yellow
stripe
green/yellow stripe
Note: To connect the wires, hold
the bare metal leads together and
place a wire connector over them,
then twist clockwise until tight.
Using an orange wire connector
from the hardware bag:
Connect the 3 grounding wires
(green, green/yellow stripe, or bare
copper) coming from the ceiling,
downrod, and ceiling bracket.
F
R
O
M
F
A
N
Place the receiver on top of the downrod
assembly as shown.
Tip: If you have difculty tting the receiver
into place, make sure you have cut the excess
wires from the fan. See page 8 for more details.
Receiver
www.HunterFan.com
1.888.830.1326
Wiring (continued)
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
12
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
Using the orange wire connectors
from the hardware bag:
Connect the black (ungrounded)
wire from the ceiling to the black
wire from the receiver.
Connect the white (grounded)
wire from the ceiling to both the
white wire from the receiver and
the white wire from the fan.
F
R
O
M
R
E
C
E
I
V
E
R
black
blue
yellow
blue
Using the orange wire connectors
from the remote control hardware bag:
Connect the yellow wire from
the receiver to the black wire
from the fan.
Connect the blue wire from the
receiver to the blue wire (or
possibly black with white stripe
wire) from the fan.
F
R
O
M
F
A
N
F
R
O
M
R
E
C
E
I
V
E
R
F
R
O
M
C
E
I
L
I
N
G
black
(ungrounded)
white (grounded)
black
white
F
R
O
M
F
A
N
white
Note: If you have a dual switch,
please cap the secondary power
wire from the ceiling. This will
result in one unused switch.
www.HunterFan.com
1.888.830.1326
Canopy
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Insert the two canopy screws
found in the hardware bag.
Screw
Holes
13
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Blades
14
Lightly attach the blade irons to the
motor with screws found in
the hardware bag, then securely
tighten after both screws are attached.
Repeat this step for each blade assembly.
Install the blade grommets, found in
the hardware bag, in the blades by hand.
Place each blade between a blade iron
and medallion. Install three blade screws,
found in the hardware bag, to attach the
medallion to the blade iron. Repeat this step
for each blade.
14
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Switch Housing
Feed the 9-pin wire plug through the
center hole of the upper switch housing,
then wrap keyhole slots around the
screws and twist counterclockwise.
Screw two housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
Insert the third screw, found in
the hardware bag, into place and
tighten all three screws securely.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all three assembly screws could result in the
switch housing xture falling.
Note: Remove the shipping
ring before installing the
switch housing. See page 6
for more details.
15
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Light Kit
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the light xture falling.
Install three switch housing assembly
screws, found in the hardware bag.
Tighten all three screws securely.
Connect the plugs from the upper and
lower switch housings. Make sure to line up
the colored markings on the connectors.
Align the screw holes in the upper switch
housing assembly with the screw holes in
the light kit assembly.
Screw
Holes
16
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Attach the globe by lifting and turning
clockwise one third of a full turn of the
glass until it stops.
NOTE: Check to ensure proper
engagement.
Install the included LED bulbs into
the sockets. When necessary, replace
with bulbs of same wattage.
Bulb
Lift the globe and align the notches in
the globe with the tabs in the light kit.
Tab
Notch
CONGRATULATIONS!
YOU’RE DONE!
17
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
Note: In compliance with Canadian federal energy regulations, this
ceiling fan contains a device that restricts its light output. Exceeding
the wattage limit marked on the MAX wattage sticker afxed to the
light socket(s) may result in re hazard or improper operation.
See next page for fan
operation instructions.
www.HunterFan.com
1.888.830.1326
Operation, Maintenance, & Cleaning
The remote transmitter is already paired to the
receiver and ready to use.
Note: If your need to pair your remote, turn fan
power off and back on at the wall switch. Within 3
minutes, press and hold both the Fan Off button
and the High button for 4 seconds to pair the
remote. To prevent faulty operation, please
ensure all other ceiling fans within range are
turned off at the wall switch while pairing.
To access the battery compartment, remove the
small Phillips head screw that secures the battery
door to the transmitter assembly. Install one
3-Volt, CR2032 battery, found in the remote control
hardware bag, into the transmitter. Clean the battery
contacts and also those of the device prior to battery
installation. The battery should be installed with the
positive (+) side up. Please contact your local battery
recycling center for proper battery disposal information.
ON
Turn Power
This product contains a button battery. If swallowed,
it could cause severe injury or death in just two hours.
Seek medical attention immediately.
CAUTION:
• Always purchase the correct
size and grade of battery most
suitable for the intended use.
• Replace all batteries of a set at
the same time.
• Clean the battery contacts and
also those of the device prior to
battery installation.
• Ensure the batteries are
installed correctly with regard to
polarity (+ and -).
• Remove batteries from equipment
which is not to be used for an
extended period of time.
• Remove used batteries promptly.
Phillips
Head
Screw
Battery
Door
18
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
The Fan Off button only turns the
fan off. To turn the fan on, press
one of the fan speed buttons.
High
Medium
Low
Operation, Maintenance, & Cleaning
ooo
oo
o
Quickly press the Light button to turn
the lights off and on. Hold the Light
button to raise and dim the light level.
Dimming Mode: To enable dimming,
your remote must be set to Dimming
Mode. To toggle Dimming Mode on
or off, hold down the Fan Off button
while pressing the Light button twice.
Low
Medium
High
Fan Off
Light
Your remote comes with a wall
plate that has two posts on which
to mount your remote transmitter
when not in use.
19
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
Operation, Maintenance, & Cleaning (continued)
Press the Fan Off button for at
least three seconds to initiate the
Safe-Exit Mode.
The lights will ash for visual
conrmation.
The lights will stay on 50%
brightness for 15 seconds and
then begin to dim. After a total
of 30 seconds, the lights will be
completely off.
The Safe-Exit Program gives
you about thirty seconds of light
when you turn the lights off to
exit the room before the lights
go out. To use Safe-Exit:
Safe-Exit
For cleaning the fan, use soft
brushes or cloths to prevent
scratching. Cleaning products may
damage the nishes.
Reverse
Switch
To switch the direction of air ow,
move the reverse switch to the
opposite position. You will need to
remove the light kit glass to do so.
20
M3573-01 • 08/08/17 • © 2017 Hunter Fan Company
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Hunter Fan 59180 Owner's manual

Category
Household fans
Type
Owner's manual

Hunter Fan 59180 is a reliable device that provides comfort and performance in your home or office for many years. It is easy to install following the instructions provided in the manual and comes with all the necessary tools. It includes a standard downrod for ceilings that are 8-10 feet high, but you can also purchase a shorter or longer downrod depending on your needs. The fan has a 7 feet minimum blade to floor clearance and requires a mounting option from building structure or fan-rated outlet box that can support 70 lbs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI