QP_ 4-5 (Convertito)-5 9-05-2000 23:25 Pagina 8
Colori compositi
C M Y CM MY CY CMY K
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
(see note on the left)
ZC. y2 ZC. y3
ZC. Io.
ZCShi. ZC.u.y.1
ZC. y6
ZC.u.y6
U
0
1
2
3
4
0
1
2
3
4
5
T
0
1
2
3
4
5
6
7
8
9
10
23
24
25
F
ZC. C.j.
ZC. y4 ZC. y5
K
H
P-Q
R-S
ZC.l.i.1 ZC.l.i.3ZC.l.i.2
0
1
2
3
4
5
6
7
8
9
10
11
N
0
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
I-J
L
ZC. y1
0
1
2
3
4
O
0 …. 50°C
32 …. 122°F
273 …. 323 K
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
0…1
2…3
4…5
ZC.1n.r.
M
0
1
2
3
4
Control output type
Y1(▲) Y1(▼)
Relay
Logic
Continuous
Servomotors
Relay
Relay
Relay
Logic
Logic
Continuous
Continuous
Continuous
SingleDouble
-999…9999
Input beginning value
for linear scales
Input full value for
linear scales for
=999…C.1o. -100 or
C.1o+100…9999
minimum span 100 counts
None
Manual control (loop A)
1st memorized Set point
2nd memorized Set point
3rd memorized Set point
Remote Set point
Local Set point
Locked keyboard
2nd P.I.D. algorythm
Y1 Remote Set point input
Y1 Forcing value
Programme Launch/Stop
Programme Run/Hold
Programme Launch-Run/Hold
Programme Stop
Programme Hold (Local S.p)
Next segment
Back to the beginnining of sgm.
(see note on the left)
Functions
of the 3 logic inputs
Relay
Logic
Continuous
Relay
Continuous
Relay
Logic
Continuous
Codes 8,10 and 11, can be selected
if the 2nd analog output option (Y6)
is fitted. These codes depend on the
Tab. B (C.Con).
If control action is
(Tab. B ) Select
(Tab. n )
On - Off
single P.I.D.
double P.I.D.
Y1 output range
4…20 mA
0…20 mA
1…5 V
0…5 V
0…10 V
Current
Voltage
Y2-Y3-Y4-Y5
Alarm type
OPTION
Y6 2nd analog output type
Retransmission
Disabled
This code is available only if the
2nd analog output has not been used
as second control output
(C. y6 Tab. N codes 8,10,11)
The code is available only if the main
output (Y1) is of the analog type
(see Tab. N codes 2, 6, 9,11).
Remote Set point
scale range
Current
Voltage
Logic input notes
2,3,4,5 & 9 codes depend on
the type of Set point previously
entered. (Tab. C)
Index 8 and from 12 to 18 are
displayed if Programmable Set point
type has been chosen.
External cool joint
temperature
Admitted
range
Enter a value coherent with the
admitted range. Higher and lower
values will not be accepted.
This code is not available with internal
Cold joint compensation Y6 output range
Current
Voltage
The code is not available if C. y6 is
disabled, Tab. T - Codes 1,2,3,4,5
or if double output is selected and Y1
(channel ▼) is logic or continuous type.
Tab. N - Codes 8,10,11
Measure X1
Set point W
Output Y1
Output Y1(channel ▼)
Deviation 0…25%
Y4 and/or Y5 outputs are not available
if the control output has been already
used as single or double relay for
servomotor output. Tab. N
Codes. 0, 3, 4, 5, 6,7, 9
(1) Only for thermoelements,
4…20mA and 1…5V
(2) Displayed if Programmable Set
point version, only.
N.A.(close)
N.C. (open)
Active high
Active low
Active high
Active low
Active outside
Active inside
Active high
Active low
N.O.(close)
N.C. (open)
Disabled
X1 Input
interruption (1)
Independent
loop A
Deviation
loop A
Band
loop A
Output Y1
loop A
Out of Prgm.
max. Dev. (2)
Is present only if Remote Set point
has been selected Tab. C codes
2,3,4.
Configured to the Prgm. (2)
19