7.8 Zone Signal Output.................................................................................................................. 104
7.9 Incremental Moves .................................................................................................................. 107
7.9.1 Judgment Method of End Position...................................................................... 109
7.9.2 Notes on Incremental Mode.................................................................................110
7.10 Jogging/Teaching Using PIO ....................................................................................................113
7.11 Operation in 7-point Type .........................................................................................................115
7.12 Operation in 3-point Type .........................................................................................................119
8. Parameters............................................................................................................ 123
8.1 Parameter Table ...................................................................................................................... 123
8.2 Detail Explanation of Parameters............................................................................................ 125
8.2.1 Parameters Relating to the Actuator Stroke Range ............................................ 125
Soft limit ......................................................................................................................125
Software limit margin .................................................................................................. 125
Zone boundary .......................................................................................................... 126
Home return direction ............................................................................................... 127
Home return offset ...................................................................................................... 127
8.2.2 Parameters Relating to the Actuator Operating Characteristics.......................... 127
PIO jog speed ............................................................................................................. 127
PIO inching distance................................................................................................... 127
Default speed.............................................................................................................. 127
Default acceleration/deceleration ............................................................................... 128
Default positioning band ........................................................................................... 128
Current-limiting value at standstill during positioning ................................................. 128
Current-limiting value during home return .................................................................. 128
Home sensor input polarity......................................................................................... 128
Speed override ........................................................................................................... 128
Default direction of excited-phase signal detectio ...................................................... 129
Excited-phase signal detection time ........................................................................... 129
Safety speed ............................................................................................................. 129
Automatic servo-off delay time ................................................................................. 130
Default standstill mode .............................................................................................. 130
Push speed ............................................................................................................... 131
Push completion judgment time ................................................................................. 131
Enable function ........................................................................................................... 132
Polarity of home check sensor input ......................................................................... 132
Load output judgment time ......................................................................................... 132
Torque check range .................................................................................................. 133
Ball screw lead length ............................................................................................... 133
Axis operation type ................................................................................................... 133
Rotational axis mode selection................................................................................... 133
Shortcut selection for rotational axis........................................................................... 133
Absolute unit ............................................................................................................... 134
Current-limiting value at standstill after missing work in push & hold operation ........ 134
8.2.3 Parameters Relating to the External Interface .................................................... 135
PIO pattern selection ................................................................................................ 135
Movement command type .......................................................................................... 136
Pause input disable selection ................................................................................... 137
Servo ON input disable selection .............................................................................. 137
Home-return input disable selection ........................................................................... 137
Operating-mode input disable selection ..................................................................... 137
Output mode of position complete signal ................................................................... 138
SIO communication speed.......................................................................................... 138