ADTZWM Series Wi-Fi® and Z-Wave® Module
Installation and Setup Guide
General Information
The Communication Module allows the Control Panel to communicate with the WTS700 Wireless Keypad and Amazon Alexa via Wi-Fi.
The ADTZWM communications module is intended to provide compatible ADT Control Panels with a Wi-Fi connection as well as
connection with and the ability to control Z-Wave devices. The module connects directly to the Control Panel and is powered via the
Control Panel’s connection. The ADTZWM Series includes models ADTZWM and ADTZWMX.
Compatible Control Panels:
ADT7AIO/ADT5AIO Series - Installation Guide P/N 800-24121 or higher.
ADTHYBWL Series - Installation Guide P/N 800-24125 or higher.
ADT2X16AIO Series – Installation Guide P/N 800-24341 or higher.
NOTE: Control Panel Firmware Release 4.5 or later is required for the ADTZWMX.
Installing the Module in the ADT7AIO/ADT5AIO or ADT2X16AIO Series
Ensure that all electrical power is removed from the control before installing the module. Unplug
the power supply and disconnect the backup battery.
1. Affix the provided FCC/IC label (P/N 800-24286 on
the Control Panel’s case back (refer to Figure 1).
2. If the Control Panel is not powered up proceed to step
5. If the Control Panel is powered up, it must be
powered down as follows:
a. ADT7AIO/ADT5AIO or WTS700 Touchscreen –
At the Advanced screen select “System
Shutdown” and confirm. Wait 30-60 seconds.
b. ADT2X16AIO or WTP100/WLTP100 Touchpad –
Enter Master Code + # +* + 9. Wait 30-60
seconds.
3. Unplug the power supply.
4. Disconnect the battery.
grip-020-V0
HONEYWELL
FCC / IC STATEMENT
800-24167 2/18 Rev A
This device complies with Part 15 of the FCC Rules, and
RSS 210 of IC. Operation is subject to the following two
conditions: (1) This Device may not cause harmful interfer-
ence. (2) This device must accept any interference received,
including interference that may cause undesired operation.
FCC ID: CFS8DL-GRIPAIO7
IC: 573F-GRIPAIO7 IC MODEL: GRIPAIO7
CONTAINS MODULE:
FCC ID: RI7LE910NAV2
IC:5131A-LE910NAV2
CONTAINS MODULE:
FCC ID: RI7LE910NAV2
IC:5131A-LE910NAV2
Figure 1. FCC/IC Label Location
5. Remove the screw securing the rear case to the front
case.
6. Slide the rear case down and separate from the front
case.
7. Remove the communication module access cover.
8. Unplug the power supply (if connected).
9. Secure the module with the provided screw.
10. Re-install the communication module access cover.
11. Connect the battery
12. Install the rear case and secure with the screw.
13. Plug the power supply into a 24-hour, 110VAC
unswitched outlet.
SCREW
grip-011-V0
COVER
SCREW
Figure 2. Installing the ADTZWM Module
Installing the Module in the ADTHYBWL Series
Ensure that all electrical power is removed from the Control Panel before installing the module. Unplug
the power supply and disconnect the backup battery and earth ground.
1. Affix the provided FCC/IC label (ADTZWM, P/N
800-24286) on the ADTHYBWL cabinet (refer to
Figure 3)
2. If the Control Panel is not powered up proceed to
step 5. If the Control Panel is powered up, it must
be powered down as follows:
a. WTP100/WLTP100 Touchpad - Enter Master
Code + # +* + 9. Wait 30-60 seconds.
b. WTS700 Touchscreen – At the Advanced
screen select “System Shutdown” and confirm.
Wait 30-60 seconds.
3. Unplug the power supply.
4. Disconnect the battery and earth ground.
BATT+ BATT -
AUX/BELL_OC LED
RUN LED
IB2/ACTIVE LED
RESERVED LED
TRIGGER 2
12V
GND
TRIGGER 1
BATTERY POWER LED
NOT
USED
HI
LO
ZONE 2
2000
OHMS
EOLR
ZONE 1
USE FOR
2-WIRE SMOKE
DETECTORS
MAXIMUM
NUMBER OF
2-WIRE SMOKE
DETECTORS
ON ZONE 1
IS 16
ZONE 1
2000
OHMS
EOLR
HI
HI
LO
LO
HI
LO
2000
OHMS
EOLR
ZONE 3
2000
OHMS
EOLR
ZONE 4
HI
HI
LO
LO
2000
OHMS
EOLR
ZONE 5
2000
OHMS
EOLR
ZONE 6
HI
HI
LO
LO
2000
OHMS
EOLR
ZONE 7
2000
OHMS
EOLR
ZONE 8
EARTH
GROUND
300-10211
13.5 VDC, 1.8A
POWER
SUPPLY TO
10VAC
UNSWITCHED
OUTLET
(24HR)
DC+
DC -
DC+
DC -
ADTHYBWL-Series - Summary of Connections
800-24129 2/18 Rev.A
RJ-45
CONNECTOR
TAMPER
SWITCH
BLACK
RED
RECHARGEABLE BATTERY
(12V, 7AH)
SEALED LEAD ACID TYPE
SEE
INSTRUCTIONS**
FOR PROPER
GROUNDING
TO INTERNET
CONNECTION
© 2018 ADT Security Services
GND
AUX
SLOT 3
GENERAL
SLOT 2
WiFi / ZWAVE
SLOT 1
LTE
8-PIN TRIGGER
CONNECTOR
AC POWER LED
TRIGGER OUTPUT 1: 100mA MAX
TRIGGER OUTPUT 2: 100mA MAX
AUX OUTPUT LED
NOT
USED
24-HR BATTERY
STANDBY REQUIRED
FOR FIRE
INSTALLATIONS.
USE 12V, 7AH
BATTERY FOR
120mA AUX POWER.
SEE INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST
4 HRS.
CHARGING VOLTAGE 13.8VDC.
MAXIMUM CHARGING CURRENT
650mA.
SEALED LEAD-ACID TYPE. BATTERY
NORMALLY NEED NOT BE REPLACED
FOR AT LEAST THREE YEARS
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER AND REMOTE TOUCHPAD
CURRENTS
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. IN ADDITION, THIS
SYSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
BLACK: TOUCHPAD GND (-) RETURN
YELLOW: TOUCHPAD IB2A
GREEN: TOUCHPAD IB2B
RED: TOUCHPAD POWER (+)
AUX. PWR
OUTPUT
10.5-13.8VDC
200mA MAX.
(120mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER
LIMITED.
}
CONNECTION OF
THE FIRE ALARM
SIGNAL TO A FIRE
ALARM HEAD-
QUARTERS OR
CENTRAL STATION
SHALL BE PERMIT-
TED ONLY WITH
THE PERMISSION
OF THE LOCAL
AUTHORITY HAVING
JURIDICTION. THE
BURGLAR ALARM
SIGNAL SHALL NOT
BE CONNECTED
TO A POLICE
EMERGENCY
NUMBER
THIS EQUIPMENT
SHOULD BE
INSTALLED
IN ACCORDANCE
WITH THE NATIONAL
FIRE PROTECTION
ASSOCIATION'S
STANDARD 72
(NATIONAL FIRE
PROTECTION
ASSOCIATION,
BATTERYMARCH
PARK, QUINCY,
MA 02169). PRINTED
INFORMATION
DESCRIBING
INSTALLATION,
TESTING,
MAINTENANCE,
EVACUATION
PLANNING AND
REPAIR SERVICE IS
TO BE PROVIDED
WITH THIS
EQUIPMENT.
820 OHMS
EOLR
ALARM
OUTPUT
10.5–13.8VDC,
2A MAX. (600mA
MAX. FOR UL
USAGE, INCLUDING
AUX POWER)
STEADY FOR
BURGLARY/PANIC,
TEMPORAL PULSE
SOUNDING FOR FIRE.
USE 702 SIREN, OR
12V BELL. SEE
INSTRUCTIONS.
FOR BELL
SUPERVISION, AND
CONNECT RESISTOR
DIRECTLY ACROSS
EXTERNAL SOUNDER.
WTP100
TOUCHPAD
1501 Yamato Road
Boca Raton, Florida 33431
ALARM STATUS
CANCEL
PANIC OFF
CODE CHIMEINSTANT
READY
TEST BYPASSMAX
STAYAWAY
TROUBLE
** FOR COMPLETE INFORMATION SEE INSTRUCTIONS 800-24126 OR HIGHER
-+AB
MAX. ZONE RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
(USE EOLR PART NUMBER P4100 PART OF KIT SAHDWR1)
ASSEMBLED IN MEXICO
ETL Listed
Household Fire
and Burglar
Warning Unit
800-21465 10/15 Rev.A
3091091
Conforms to UL STD 985, 1023, 1635
Classified to ANSI/SIA CP01-2010
Model LCP500-L
800-24232 3/18 Rev A
HONEYWELL GRIP HYBRID CONTROLLER
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions:
(1) This Device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: CFS8DL-GRIPH
IC: 573F-GRIPH
HVIN: GRIPH
For Patent Information see: www.honeywell.com/patents
Country of Origin: Mexico
grip-028-V0
CONTAINS MODULE:
FCC ID: RI7LE910NAV2
IC:5131A-LE910NAV2
CONTAINS MODULE:
FCC ID: RI7LE910NAV2
IC:5131A-LE910NAV2
Figure 3. FCC/IC Label Location