  • Hello! I've reviewed the operating manual for the Meitav-tec FHV-H1-PR-IR thermostat. This manual covers how to turn the device on/off, set the temperature, program the clock, and configure daily schedules with 'Wake', 'Day', and 'Sleep' modes, as well as how to adjust temperature offset. I'm ready to answer your questions about the thermostat's functionality.
  • How do I turn the unit on or off?
    How do I adjust the set-point temperature?
    How do I access the programming menu?
    How can I override the program?
    How long will the memory hold during a power failure?
File:fhv-h1-pr-ir.doc
Meitav-tec Ltd. (Contel group), 6 Sapir street, New Industrial Zone P.O.B 5221 Rishon-Lezion, 75150, Israel
Tel:
+
972
-
3
-
9626462, Fax:
+
972
-
3
-
9626620, Web: www.meitavtec.com, E
-
FHV-H1-PR-IR - Operating manual
1. Turnning the unit ON or OFF
Press the ON button to turn the unit ON or OFF – “ON” or “OFF” will appear on display.
2. Setting temperature
Press the (+) or (-) buttons – the set-point temperature will appear on display.
Adjust the set-point temperature using the (+) or (-) buttons.
3. Programming
Clock Set
Press the SELECT button – the hours will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Press the SELECT button again – days will flash.
Adjust the day of the week using the (+) or (-) buttons.
Weekdays – Monday through Friday
Program: ‘Wake’ – Start & Stop time
Press the SELECT button – the hours for start ‘wake’ program will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Press the SELECT button – the hours for stop ‘wake’ program will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Program: ‘Day’ – Start & Stop time
Press the SELECT button – the hours for start ‘Day’ program will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Press the SELECT button – the hours for stop ‘Day’ program will flash.
Adjust the hours using the (+) or (-) buttons.
File:fhv-h1-pr-ir.doc
Meitav-tec Ltd. (Contel group), 6 Sapir street, New Industrial Zone P.O.B 5221 Rishon-Lezion, 75150, Israel
Tel:
+
972
-
3
-
9626462, Fax:
+
972
-
3
-
9626620, Web: www.meitavtec.com, E
-
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Program: ‘Sleep’ – Start & Stop time
Press the SELECT button – the hours for start ‘Sleep’ program will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Press the SELECT button – the hours for stop ‘Sleep’ program will flash.
Adjust the hours using the (+) or (-) buttons.
Press the SELECT button again – the minutes will flash.
Adjust the minutes using the (+) or (-) buttons.
Saturday
Repeat the steps above for Saturday.
Sunday
Repeat the steps above for Sunday.
End Programming
Press the SELECT button again to return to normal display mode.
At any time during the programming, you can jump between the 5-1-1 days programs using the ON
button. This is also helpful when you want to review the program.
Every time a new program activates, it takes the thermostat up to 15 minutes to learn the
environmental conditions and activate settings.
The thermostat will automatically return to normal display mode when no key is pressed for 20
seconds.
The thermostat memory (program and real time clock) will hold for 12 hours during power failure
without the use of batteries.
Overriding the Program
Press and hold the ON button (10 seconds) - the word “Program” will disappear from display.
The return to program mode – press and hold the On button again (10 seconds).
File:fhv-h1-pr-ir.doc
Meitav-tec Ltd. (Contel group), 6 Sapir street, New Industrial Zone P.O.B 5221 Rishon-Lezion, 75150, Israel
Tel:
+
972
-
3
-
9626462, Fax:
+
972
-
3
-
9626620, Web: www.meitavtec.com, E
-
4. Technician settings – Offset for temperature reading
The Offset is used for field calibration of the measured temperature if necessary.
Set the temperature to 10°C.
Press and hold the SELECT button until “0” appears on display
Adjust the offset using the (+) and (-) buttons (range -6°C/+6°C – default 0°C).
/