VIAIR 20005 is a 150 PSI HIGH-FLOW AIR SOURCE KIT with a 2.0 Gallon Air Tank that is capable of inflating tires, powering air tools, and more. It features a 1/2-inch tank port for easy connection to air lines, a 3/8-inch I.D. air line, and a 25-amp minimum fuse holder for protection. The kit also includes four grommets, four sets of bolts, nuts, washers, and locking washers for mounting. The air compressor is equipped with an Automatic Reset Thermal Protector to prevent overheating and damage. It has a maximum working pressure of 150 PSI and a 30% duty cycle at 100 PSI.

VIAIR 20005 is a 150 PSI HIGH-FLOW AIR SOURCE KIT with a 2.0 Gallon Air Tank that is capable of inflating tires, powering air tools, and more. It features a 1/2-inch tank port for easy connection to air lines, a 3/8-inch I.D. air line, and a 25-amp minimum fuse holder for protection. The kit also includes four grommets, four sets of bolts, nuts, washers, and locking washers for mounting. The air compressor is equipped with an Automatic Reset Thermal Protector to prevent overheating and damage. It has a maximum working pressure of 150 PSI and a 30% duty cycle at 100 PSI.

USER MANUAL
IMPORTANT:
It is essential that you and any other operator of this
product read and understand the contents of this
manual before installing and using this product.
SAVE THIS MANUAL FOR FUTURE REFERENCE
150 PSI HIGH-FLOW
AIR SOURCE KIT
30% Duty Compressor on
2.0 Gallon Air Tank
PART NO. 20005
IMPORTANT SAFETY INSTRUCTIONS:
CAUTION: To reduce risk of electrical shock or electrocution:
- Do not disassemble. Do not attempt repairs or
modications.Refertoqualiedserviceagenciesforall
serviceandrepairs.
- Do not use this product in or area where it can fall or be
pulledintowaterorotherliquids.
- Donotreachforthisproductifithasfallenintoliquid.
- Usethiscompressorwith12-voltDCsystemsonly.
- Thisproductshouldneverbeleftunattendedduringuse.
WARNING:Topreventinjuries:
- Neverallowchildrentooperatethiscompressor.
Closesupervisionisnecessarywhenthiscompressor
is being used near children.
- Thiscompressorwillbecomeveryhotduringand
immediately after use. Do not touch any part of this
compressor with bare hands other than the
ON/OFF switch during and immediately after use.
- Donotusethisproductnearamesorexplosive
materials or where aerosol products are being used.
- Donotoperatethisproductwhereoxygenis
being administered.
- Do not pump anything other than atmospheric air.
- Neverusethisproductwhilesleepyordrowsy.
- Donotuseanytoolsorattachmentswithoutrst
determiningmaximumairpressureforthattool
or attachment.
- Neverpointanyairnozzleorairsprayertoward
another person or any part of the body.
- ThisaircompressorisequippedwithanAutomatic
ResetThermalProtector,andcanautomaticallyrestart
afterthethermalprotectorresets.Alwayscutoffpower
sourcewhenthermalprotectorbecomesactivated.
- Wear safety glasses or goggles when operating this product.
- Useonlyinwellventilatedareas.
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
INSTALLATION:
Please read and follow the Installation Instructions
carefully to avoid injury or damage to the compressor
or your vehicle.
Selecting a Mounting Location:
The selection of a proper mounting location for your air
sourcekitwillhelpensurealongandtroublefreeservicelife.
Pleasepay close attention to the following guidelines:
1. Select a FLAT,UPRIGHTANDSECURE location where
the air source kit can be mounted.
2.Tomaximizeaircompressorperformance,locate
compressor as CLOSETOTHEBATTERY as possible so
thatlengthofpositiveleadwirerequiredisataminimum.
3.Choosemountinglocationthatisascoolaspossible
and AWAYFROMHEATSOURCES. The cooler the ambient
temperaturethelesschancethecompressorwilloverheat.
4.Thecompressorismoisture&splashresistant,but
NOTWATERPROOF. Do not mount air source kit in locations
where the unit is likely to come in contact with water.
5. If it is necessary to mount the air compressor further away
fromthebattery,suchasinsideyourvehicleorinthebedof
yourpickup,useaminimum8-10AWGpositiveleadwire
for remote installation.
6.Donotmountairsourcekitnearareaswhereammable
liquidsarestored.
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
MOUNTING AND WIRING:
1.Disconnectgroundcablefromvehicle’sbattery.
2. Temporarily position the air source kit in the location
where it will be mounted.
3.Routegroundwiretothenegativepostofthebatteryorto
an appropriate grounding point and cut ground wire to
length as needed.
4.Mountairsourcekitattanklegmountswiththefour
grommets,andfoursetsofbolts,nuts,washers,
andlockingwashersprovided.Useofthreadsealant
is recommended.
5.Route3/8-inchI.D.airlinefromthe1/2-inchtankport
toa3/8-inchcompressionttingandmakeyourairline
connection.Tightencompressionttingnutsecurely
using a wrench.
6.Connectground(Black)wiretoacleanground,(preferablya
negativepostofbattery)andsecurewitha
self-tapping screw.
7.Connectpositive(Red)leadwirefrompre-installed
pressureswitchtoafuseholder(25-ampminimum).
8.Oncethekitisproperlyfusedascloseaspossibleto
thepowersource,connectandtestcompressorsystem
by running the compressor for a short time to build up
pressure in your air tank.
9. Once air pressure reaches preset cut out pressure of
yourpressureswitch(100PSIcut-on,145PSIcut-off),the
compressor will shut off automatically. Inspect all air line
connections for leaks with soap and water solution. If a leak
isdetected,theairlinemaynotbecutsquarelyorpushed
all the way in. Tighten connections if needed.
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
OPERATING INSTRUCTIONS:
1. IMPORTANT:AlwaysoperatethecompressorBELOWthe
MAXIMUMPRESSURERATINGofthecompressor.
PleaserefertoApplication&SpecicationsSectionsof
this manual for details.
2.AlwaysobservetheMAXIMUMDUTYCYCLEofthe
aircompressor.RefertoCompressorApplications
andSpecicationsSectionofthismanualfordetails.
Operationexceedingmaximumpressureratingsandor
duty cycle will result in damage to air compressor.
3.YouraircompressorisequippedwithanAUTOMATIC
THERMALOVERLOADPROTECTOR.Thisfeatureis
designedtoprotecttheaircompressorfromoverheating
causing permanent damage to your air compressor.
Thethermaloverloadprotectorwillautomaticallycutoff
power to your air compressor should the internal operating
temperatureoftheaircompressorriseabovesafelevels
duringexcessiveuse.
4.Shouldatanytimeduringuse,youraircompressor
automatically shuts off; do not attempt to restart air
compressor. Turn power switch to the air compressor to
theOFFposition.Theautomaticthermaloverloadprotector
will automatically reset when internal temperature of the
aircompressordropsbelowsafelevels.Afterallowing
aircompressortocooloffforabout30minutes,youcan
safely resume use of the air compressor by turning on
the air compressor.
5.Topreventdischargeofyourvehicle’sbattery,westrongly
recommendthatyoukeepthevehicle’senginerunning
whileusingtheaircompressor.Compressorperformance
isenhancedwhenoperatingcompressorwithvehicle’s
engine running.
6. IMPORTANT:ONLYOPERATETHEAIRCOMPRESSOR
INWELL-VENTILATEDAREAS.
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
AIR TANK PRECAUTIONS:
IMPORTANT:
a.Theairsourcekitairtankisratedfor150PSImaximum
workingpressure.Donotoverll.Overllingmayresultin
deathorseriousinjury.
b.Tankisnottobeusedasabreathingdevice.
c.AlwayswearANSIapprovedsafetyglasseswhen
operating air tank.
d.Bleedpressurefromtankaftereachuse,andbefore
servicingoraddingattachments.
e.Useonlyattachmentsortoolsratedfor150PSIworking
pressure or less.
DRAIN TANK OFTEN TO REMOVE CONDENSATE.
FAILURE TO DRAIN TANK WILL ALLOW TANK TO
RUST INTERNALLY.
a.Toremoveanyaccumulatedcondensationinsidethetank,
bleedpressurefromtankuntilpressureisapproximately
5PSIto20PSI.
b.Drainwaterfromtankbyopeningthedraincockdrainvalve.
c.Ifdraincockisplugged,releaseallairpressurefromtank,
removedrainvalveandclean,thenreinstall.
d.Aftercondensatehasbeendrained,closethedraincock.
IMPORTANT:ObserveairtankDateofManufacture(stamped
ontankleg).Replaceairtank2to5yearsfromdateairtank
wasrstused,orusethedateofmanufactureasreference.
Youradherencetoairtankdrainingguidelineswilldetermine
thereplacementdateofyourairtank.RUSTEDTANKSCAN
FAILCAUSINGEXPLOSIONSORFATALINJURIES.Discard
tank immediately if tank is rusted.
NOTE: Whenusingasafetypressurereliefvalve,pointthe
safetypressurereliefvalveawayfromyourbody.Usethepull
ringonthesafetyreliefvalve;openthereliefvalvetoventany
pressureinsidethetankbeforeattemptingtoservicetank.
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
COMPRESSOR APPLICATION GUIDE:
ABOUT COMPRESSOR DUTY CYCLE:
Duty cycle refers to the amount of time a compressor can
beoperatedinagiventimeperiodat100PSI,andastandard
ambienttemperatureof72°F.Itiscommonlyexpressedin
percentageformat:Compressorontime÷(ontime+offtime)=
DutyCycle%.
ONE-HOUR DUTY CYCLE MINUTES ON /
(100PSI@72°F) MINUTES OFF
9% 5Min.On/55Min.Off
10% 6Min.On/54Min.Off
15% 9Min.On/51Min.Off
20% 12Min.On/48Min.Off
25% 15Min.On/45Min.Off
30% 18Min.On/42Min.Off
33% 20Min.On/40Min.Off
50% 30Min.On/30Min.Off
100% 1HourRunTime
NOTE:Allcompressors,regardlessofrateddutycycle,require
sufcientresttimeinbetweencyclestoallowforpartialor
completeheatdissipation.Heatdissipationratesmayvary
depending on ambient temperatures and operating conditions.
ABOUT RATED WORKING PRESSURE:
Toensuretroublefreeservicelifeofyourcompressor,always
operate compressor within rated working pressure of the
compressor.Neveruseapressureswitchwithahigher
cut-offpressurethancompressor’sratedworkingpressure.
SPECIFICATIONS:
280CAIRCOMPRESSOR
MotorVoltage: 12Volts
Max.CurrentConsumption: 20Amps
RecommendedFuse: 30Amps
MotorType: Perm.Magnetic
HorsePower: 1/4
Max.WorkingPressure: 150PSI
Max.DutyCycle(@72°F&100PSI): 30%
MinutesOn/Off(@72ºF&100PSI): 18On/42Off
ContinuousUse(@72ºF&40PSI): 40Minutes
Max.AmbientTemperature: 158°F
Min.AmbientTemperature: -40°F
Auto.ResetThermalProtection: Yes
Excessivemoistureindischarge 1.Excessivewaterinairtank
2.Highhumidity
1.Draintank,tilttanktodrain.
Draintankmorefrequently
2.Movecompressortoareawithlesshumidity,
oruseairlinelter.
Compressorwillnotrun 1.Nopower,orpowerswitch
in OFF position
2.Blownfuse
3.Motoroverheats
4. Faulty pressure switch.
1.MakesurecompressorswitchisON
2.Disconnectcompressorsfrompowersource,
replacefuse.(RefertoSpecicationssectionfor
correctfuseamperage.)
3.Letcompressorscooloffforabout30Minutes
toallowthermaloverloadswitchreset.
4.Replacepressureswitch
Thermaloverloadprotector
cuts out repeatedly
1.Lackofproperventilationor
ambient temperature too high
2.Compressorvalvesfailed
1.Movecompressortowellventilatedarea,
or area with lower ambient temperature
2.Repairorreplacecompressor
Excessiveknockingorrattling 1. Loose mounting bolts
2. Worn bearing on eccentric or
motor shaft
3.Cylinderorpistonringisworn
1. Tighten mounting bolts
2.Repairorreplacecompressor
3.Repairorreplacecompressor
CAUTION: NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED.
Tank pressure drops when
compressor(s)shutoff
1. Loose drain cock
2.Checkvalveleaking
3. Loose connections
1. Tighten drain cock
2.Replacecheckvalveorcompressor(s)
3.Checkallconnectionswithsoapand
water solution and tighten
Compressorrunscontinuouslyand
airowlowerthannormal
1.Excessiveairusage
2. Loose connections
3.Wornpistonringorinletvalve.
4.Cloggedairlterelement
1. Decrease air usage
2.Checkallconnectionswitsoapand
water solution and tighten.
3.Repairorreplacecompressor
4.Replaceairlterelement
Compressorrunscontinuouslycausing
safetyvalve(ifequipped)toopen
1.Badpressureswitch
2.Defectivesafetyvalve
1.Replacepressureswitch
2.Replacesafetyvalve
PROBLEM: POSSIBLECAUSE(S) CORRECTIVEACTION
TROUBLESHOOTING GUIDE:
150 PSI HIGH-FLOW AIR SOURCE KIT
USER MANUAL
LIMITED WARRANTY:
VIAIRCorporationwarrantsthisproduct,whenproperly
installedandundernormalconditionsofuse,tobefreefrom
defects in workmanship and materials for a period of one year
fromitsoriginaldateofpurchase.Toreceivewarrantyservice
orrepair,pleasecontactVIAIRCorporation.
Returnsshouldbemadewithinoneyearofthedateof
purchase,afteraReturnGoodsAuthorization(RGA)number
hasbeenassignedbyVIAIRCorporation.ToobtainRGA,
faxacopyofyourreceiptto(949)585-0188.Forcomplete
warrantydetails,pleasevisit:www.viaircorp.com/warranty
PLEASE NOTE:
THISWARRANTYCOVERSPRODUCTDEFECTSONLY;
ITDOESNOTCOVERINCIDENTALORCONSEQUENTIAL
DAMAGESASRESULTOFMISUSEORABUSE.
15EDELMAN•IRVINE,CA92618
TEL:(949)585-0011•FAX:(949)585-0188
www.viaircorp.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

VIAIR 20005 User manual

Category
Air compressors
Type
User manual

VIAIR 20005 is a 150 PSI HIGH-FLOW AIR SOURCE KIT with a 2.0 Gallon Air Tank that is capable of inflating tires, powering air tools, and more. It features a 1/2-inch tank port for easy connection to air lines, a 3/8-inch I.D. air line, and a 25-amp minimum fuse holder for protection. The kit also includes four grommets, four sets of bolts, nuts, washers, and locking washers for mounting. The air compressor is equipped with an Automatic Reset Thermal Protector to prevent overheating and damage. It has a maximum working pressure of 150 PSI and a 30% duty cycle at 100 PSI.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI