Safety
Never use the Multitester on direct or alternating current circuits with
an effective voltage over 600 V, or at an effective voltage of ± 600 V
compared to the earth voltage.
Always check the condition of the batteries before using your Multitester 709.
Never carry out resistance tests on a circuit under tension.
Never open the Multitester case without first disconnecting it from any power source.
Never connect the Multitester to the circuit to be tested if the case is not properly
closed.
Specifications
Dimensions : 170 x 65 x 30 mm.
Weight : 200 g including batteries.
2 batteries : 1.5 volt
(R6 or LR6 type).
Endurance : 10,000 tests of 10 seconds each using R6 batteries.
20,000 tests of 10 seconds each using LR6 batteries.
Consumption : < 5 mA used as voltmeter.
< 20 mA used as ohmmeter with audible signal.
< 50 mA with lighting.
Capacity
Voltmeter : 600 volt maximum in AC and in DC.
Ohmmeter : 2 k maximum.
Stops automatically when contacts are no longer connected.
NB: Operates automatically when contacts are connected to electrical tension.
Operating temperature : -10° to +55° C
Storage temperature : -40° to +70° C
Relative humidity in use : 10% to 90% RH
Relative humidity in storage : 5% to 95% RH
Double isolation : Installation category III - contamination degree 2
(in accordance with IEC standard 1010-1).
Isolation protection indicator : IP 54
(in accordance with IEC 529).
Radiated fields : 3 V/m
(in accordance with IEC 801-3).
Free fall : 1 m
(in accordance with IEC 1010).
Vibration : 0.75 mm
(in accordance with IEC 68.2.6).
Shock : 0.5 Joule
(in accordance with IEC 68.2.27).
Electric shock : 3 kV
(in accordance with IEC 801-5).
Electrostatic discharge : 4 kV class 2
(in accordance with IEC 801-2).
Surges : 2 kV
(in accordance with IEC 801-4).
Automatic lighting : Over 50 lux.
Anti-slip protector
Winding groove for lead
2 captive screws enabling the lower half of the case to be removed to change the
batteries.
Housing for removable contact.
Slide for engaging and protecting black contact.
Beep for continuity test (R 500 ± 50 )
Comes with a black lead
(length 1.40 m)
with a non-removable contact, a removable
red contact, an instruction booklet, a one-year certificate of guarantee and 2 1.5 volt
R6 batteries
(not fitted).
10
Reading the display
Liquid crystal display with 2,000 measurement gradations
(figure height: 10
mm)(maximum 600 V)
and measurement frequency of two measurements per second.
Automatic symbol display. The left-hand side "
1
" is a flashing display. Automatic
setting selection.
The symbol indicated below lights up when the particular function is activated.
Batteries are low.
HOLD Last value stored in memory.
~ Present measurement is of alternating current.
Present measurement is of direct current.
Continuity test function is active
(beep function is activated)
.
k mV The test unit symbol is activated.
The figures display the value of the test unit.
A - Fit the removable red plug in the housing on the top side of the equipment.
B - Fit the plug at the end of the black lead as indicated by «B» in the diagram below.
Thus positioned, the distance between the two contacts is the same as that found on
standard electric plugs.
B
11
Measuring direct or alternating current voltages
Place the contacts in parallel on the circuit to be measured.
The equipment will begin to operate automatically, recognising whether the
current is direct or alternating and choosing the most appropriate of the four
possible settings to measure the tension.
Read the value shown on the display.
The value can be stored by pressing HOLD.
AC voltmeter * ~ Settings
DC voltmeter 2 V 20 V 200 V 600 V
Resolution 1 mV 10 mV 100 mV 1 V
Impedance 600 k
260 k
AC precision ~ ± 3 % of figure displayed ± 5 points
DC precision ± 2 % of figure displayed ± 2 points
Permitted overload 1000 V effective voltage over 5 seconds
* Operational range: 10 Hz to 400 Hz sinusoidal.
NB: If there is no readout on the display, there is no voltage or the voltage
is lower than 600 mV.
Automatic stop: once disconnected from the circuit, the Multitester 709 will
switch off automatically and the display will go out.
The 709 can detect phase and neutral in an outlet socket:
Non-earthed socket:
Introduce the red contact into the socket
(the black contact is not used)
:
if the display lights up, this is phase.
if the display does not light up, this is neutral.
Earthed socket:
By attaching the black contact to earth and the red contact to phase or
neutral, the earth/phase or earth/neutral tension can be measured without
causing any break in the differentials
(consumption of 1.4 mA at 380 V)
.
...
12
Measuring continuity and resistance
Remove supply to the circuit or resistance to be tested.
Connect the Multitester to the terminals of the circuit or resistance to be
tested.
Press the push button on the back of the equipment and keep
this button pressed in for the duration of the test; in this way the
display is programmed at the 2 k setting.
Read the value shown on the display.
The value can be stored by pressing HOLD.
Disconnect the 709 from the circuit and stop pressing the push button: the
equipment stops automatically.
(Ohm) : 2 k
(1)
Resolution : 1
Precision : ± 3% of figure displayed ± 2 points
Maximum tension on open circuit : 400 mV
Maximum short circuit tension : 150 µA
Electronic protection : 600 V effective tension
(maximum 5 seconds)
(1)
Produces continuous beep sound when
for total resistance : R 500 ± 50
for a specific resistance : R > 1,999 k and the «1» is flashing.
Volt test:
If the circuit is accidentally placed under tension during the resistance test,
the red warning light above the volt test symbol comes on.
Stop pressing the ohmmeter button immediately; the 709 will display the
value of the voltage present.
13
Servicing
To store the equipment:
Place the red contact in its housing on the back of the equipment.
Wind the black lead around the winding groove and fit the black
contact onto the side
(see diagram below).
To change the batteries, first remove the two screws from the lower
half of the equipment case.
Spare parts
709
1 709.02 Removable contact
2
R6 or LR6 battery
1.5 volt battery (2)
1
2
36
UNITED KINGDOM
EIRE
FACOM Tools Ltd
Bridge Wharf - Bridge Road
CHERTSEY - SURREY KT16 8LJ
UNITED KINGDOM
: (01932) 566099
Fax : (01932) 562653
DEUTSCHLAND
FACOM GmbH
Postfach 13 22 06
42049 Wuppertal
Otto-Wels-Straße 9
42111 Wuppertal
DEUTSCHLAND
: (0202) 704051
Fax : (0202) 706958
NEDERLAND
FACOM Gereedschappen BV
Kamerlingh Onnesweg 2
Postbus 134
4130 EC Vianen
NEDERLAND
: (0347) 372334
Fax : (0347) 376020
ESPAÑA
PORTUGAL
FACOM Herramientas, S.L
Poligono industrial de Vallecas
C/.Luis 1°, s/n-Nave 95 - 2°Planta
28031 Madrid
ESPAÑA
: (91) 778 21 13
Fax : (91) 778 27 53
ITALIA
U.A. FACOM Italia
Via Ronchetti 3
21041 Albizzate (VA)
ITALIA
: (0331) 985811
Fax : (0331) 985930
®
BELGIQUE/BELGIE
S.A. FACOM N.V
Weihoek 4 1930 Zaventem
BELGIQUE
: (02) 714 09 00
Fax : (02) 721 24 11
SUISSE/SCHWEIZ
AUSTRIA
FACOM S.A./AG
12 route Henri-Stéphan
1762 Givisiez/Fribourg
SUISSE
: (4126) 466 42 42
Fax : (4126) 466 38 54
UNITED STATES
FACOM TOOLS Inc.
3535 West 47th Street
Chicago Illinois 60632
U.S.A.
: (773) 523 1307
Fax : (773) 523 2103
SINGAPORE
FAR EAST
FACOM Tools FAR EAST Pte Ltd
15 Scotts Road
Thong Teck Building # 08-01-02
Singapore 228218
SINGAPORE
: (65) 732 0552
Fax : (65) 732 5609
FRANCE
Société FACOM
6-8 rue Gustave Eiffel BP.99
91423 Morangis cedex
FRANCE
: 01 64 54 45 45
Fax : 01 69 09 60 93
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Facom 709 Owner's manual

Category
Measuring & layout tools
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI