Tripp Lite PDUMH32HVNET Owner's manual

Category
Power distribution units (PDUs)
Type
Owner's manual
1
Owner’s Manual
1111 W. 35th Street • Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2011 Tripp Lite. All rights reserved.
PDUMH30NET
120V, 50/60Hz Input and Output
PDUMH30HVNET/PDUMH30HV19NET/
PDUMH32HVNET
208/230V, 50/60Hz Input and Output
Switched Rack PDU
Important Safety Instructions 2
Installation 3
Configuration and Operation 7
Features 7
Technical Support 9
Warranty and Warranty Registration 10
Español 11
Français 21
Warranty
Registration
Register online today for a
chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
201105095 93-3048.indb 1 6/15/2011 3:07:21 PM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should
be followed during the installation, operation, and storage
of this product. Failure to heed these instructions and
warnings will void the product warranty.
Important Safety Instructions
•ThePDUprovidesconvenientmultipleoutlets,butitDOESNOTprovidesurgeor
line noise protection for connected equipment.
•ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfrom
excessmoisture,temperatureextremes,conductivecontaminants,dustordirect
sunlight.
•DonotconnectthePDUtoanungroundedoutletortoextensioncordsoradapters
that eliminate the connection to ground.
•ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmust
not exceed the individual outlet’s load rating.
•ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceed
themaximumloadratingforthePDU.
•DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-
serviceablepartsinside.
•DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
•DonotattempttousethePDUifanypartofitbecomesdamaged.
•DonotattempttomountthePDUtoaninsecureorunstablesurface.
•Neverattempttoinstallelectricalequipmentduringathunderstorm.
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipment
canreasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenor
nitrous oxide.
•OperatethePDUatindoortemperaturesbetween32degreesFand104degreesF
(between0degreesFand40degreesC)only.
•Provideadequateprotectionagainstexcesscurrents,shortcircuitsandground
faultsinaccordancewithlocalandnationalelectricalcodes,suchasNECinthe
US.
•ThemainsocketoutletthatsuppliesthePDUshouldbenearthePDUandeasily
accessible.
201105095 93-3048.indb 2 6/15/2011 3:07:21 PM
3
Installation
Mounting the PDU
Caution! Before mounting the PDU, ensure that a compatible, easily
accessible and properly grounded AC outlet is available in the location.
ThePDUsupportstwomountingconfigurations:2URackandUnder-Counter.
Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before
mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may
not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the
mounting brackets and cord retention shelf to the PDU are included. Use only the screws supplied by the
manufacturer, or their exact equivalent (#8-32, 3/8” flat head screw for mounting bracket, #6-32, 1/4” flat
head screws for cord retention shelf).
1-1
2U Rack Mounting: Attach the
includedbracketstothesidesof
thePDU(STEP
1A
)withthe
included screws. After installing the
brackets,positionthePDUinthe
rackandinstallfouruser-supplied
screwsthroughtheunit'sbrackets
(STEP
1B
)andintotherackrails
as shown.
1-2
Under-Counter Mounting: Use4
included screws
A
to attach each
ofthe2mountingbrackets
B
to
thePDUasshown.MountthePDU
underthecounterbyinserting2or
moreuser-suppliedscrews
C
throughthemountingbrackets
D
and into secure mounting points.
1-3
Cord Retention Shelves
Attachment (Optional): Use
included screws
A
to attach the
cord retention shelves
B
to the top
andbottomofthefrontpanelof
thePDUasshown.
1A
1-2
1B
1-2
1-3
A
B
D
C
B
A
201105095 93-3048.indb 3 6/15/2011 3:07:22 PM
4
Connecting the PDU
2-1
Plug the PDU into a Compatible
Electrical Outlet: (120VL5-30R
forModelPDUMH30NET;
208/230VL6-30RforModels
PDUMH30HVNET&
PDUMH30HV19NET;IEC3092P
+EforModelPDUMH32HVNET).
2-2
Connect Equipment to the PDU's
Output Receptacles: Plug
equipmentintotheNEMA
5-15/20R(ModelPDUMH30NET),
IEC60320C13(Models
PDUMH30HVNET&
PDUMH32HVNET)orIEC60320
C13&C19(Model
PDUMH30HV19NET)output
receptaclesofthePDU.TheLED
A
near each output receptacle will
illuminate when the receptacle is
readytodistributeliveACpower.
The digital load meter
B
maybe
set with the switch
C
to display in
ampsthePDU'stotalconnected
load(alloutlets),ortheload
carriedbyeithertheupperorlower
bankofoutletreceptacles.When
the total connected load display is
selected,bothofthegreenLEDsto
the right of the display
D
will
illuminate.Whenthetopbank
displayisselected,onlythetop
LEDwillilluminate;whenthe
bottombankdisplayisselected,
onlythebottomLEDwillilluminate.
2-3
Cord Retention (Optional): Ifyou
attached the cord retention shelves
(STEP
1-3
),usethemtosecure
equipment power cords. Attach
eachcordtotheretentionshelfby
looping the cord and securing it to
an attachment point with one of
theincludedcableties.Makesure
that each equipment power cord
canbeunpluggedfromthePDU
withoutremovingthecabletie.
Installation
2-1
2-2
2-2
2-2
2-3
Your model may vary.
DB A
C
BC D A
C B D A
201105095 93-3048.indb 4 6/15/2011 3:07:23 PM
5
Cord Retention System (PDUMH32HVNET Only)
ToassureasecureconnectionwhenpluggingequipmentintothePDU,usethe
included cord retention system. Follow this procedure for each item of equipment you
connect:
Installation
3-1
Insertacordretentionstrap
A
into
the mounting hole to the right of
thePDUoutlet
B
,pressingfirmly
untilitlocksinplace.IMPORTANT:
when installing the cord retention
strap,ensurethatitsgrooved
surface faces right. The strap will
not function properly if it is
installed with its grooved surface
facing left.
3-2
PlugtheequipmentintothePDU
outlet.
3-3
Slipacordretentionsleeve
C
over
the equipment power cord.
3-4
Slidethecordretentionstrap
through the slot on the cord
retentionsleeve.Pressoutonthe
smalltab
D
at the front of the slot
toinsertthestrap;releaseitto
lockthestrapinplace.
3-5
Lockthecordretentionsleeveover
thepowercordbypressingback
thetabtoengagethelocking
threads.
3-6
Tighten the cord retention strap as
necessary to secure the power
cord against accidental
disconnection.
To disconnect equipment, press out on the slot tab to unlock the cord
retention strap and pull back the cord retention sleeve until it disengages.
3-1
3-2
3-4
3-5
3-3
A
B
Grooved Surface
C
D
201105095 93-3048.indb 5 6/15/2011 3:07:25 PM
6
Installation
Networking the PDU (Only Applicable to Models with
SNMP Network Card Installed)
ForinstructionsonnetworkingthePDU,pleaserefertotheSNMPWEBCARDQuick
StartGuideontheincludedCD-ROM.
Note: The MAC address of the PDU (a 12-digit string in this format: 000667xxxxxx) is printed on a label
attached to the PDU enclosure. The MAC address is also printed on a label attached to the internal network
card.
Testing Network Connection
4-1
Access PDU with Web Browser:
AfteranIPaddresshasbeen
assignedtothePDU,attemptto
accessitwithaWebbrowserthat
supportsframes,formsandJava™.
OpenaWebbrowserona
computerconnectedtotheLAN
andentertheIPaddressassigned
tothePDU.Youshouldbe
prompted for a password
A
. The
user name is admin and the
default password is admin. After
you enter the user name and
password,thePowerAlertStatus
page
B
willappearinthebrowser
window. For more information
aboutconfigurationandoperation
ofthePDUviathePowerAlert
interface,refertothe
SNMPWEBCARDUser'sGuide,
includedontheCD-ROMbundled
withthePDU.
Note for Network Management System Users
Only: Two MIB files—Tripplite.mib and
RFC1628.mib—must be loaded on each
Network Management Station that will
monitor the PDU via SNMP. The files are
provided on the CD-ROM included in the
product package.
A
B
201105095 93-3048.indb 6 6/15/2011 3:07:26 PM
7
Output Receptacles: ThesereceptaclesdistributeACpowertoconnected
equipment.Whenareceptacleislive,theassociatedgreenLEDisilluminated.
Features
Configuration and Operation
Remote Monitoring and Control
ThePDUprovidesremotemonitoring
A
,
outlet control
B
andmoreviaWeb
browser,telnetandSNMP-based
NetworkManagementSystems.Formore
informationaboutconfigurationand
operationofthePDUviathePowerAlert
Webbrowserinterface,refertothe
SNMPWEBCARDUser'sGuide,included
ontheCD-ROMbundledwiththePDU.
Primary AC Input Power Cord: ConnecttheinputplugtoacompatibleACpower
outlet.ThecordispermanentlyattachedtothePDU.
208/230VIEC60320C13
OutputReceptacles
(PDUMH30HV19NET,
PDUMH30HVNET&
PDUMH32HVNET)
208/230VIEC60320C19
OutputReceptacles
(PDUMH30HV19NET)
L5-30PInputPlug:120V,
(PDUMH30NET)
IEC3093-PoleInputPlug:
208/230V,(PDUMH32HVNET)
L6-30PInputPlug:208/230V,
(PDUMH30HVNET&
PDUMH30HV19NET)
120VNEMA5-15/20ROutput
Receptacles(PDUMH30NET)
A
B
201105095 93-3048.indb 7 6/15/2011 3:07:28 PM
8
Features
Digital Load Meter (Ammeter): The digital load meter
displaystheloadinamps.ItmaybesetusingtheMeter
SelectswitchtodisplaythePDU'stotalconnectedload
(all16outlets-bothLEDsilluminated),ortheloadcarried
byeithertheupperbank(Bank1LEDilluminated)or
lowerbank(Bank2LEDilluminated)of8outlet
receptacles.FormodelswithSNMPNetworkCard
installed,pressandholdtheswitchtodisplaytheIP
addressoftheSNMPcardinthePDU.
Output Circuit Breakers: Twocircuitbreakers(oneper
outletbank)protectconnectedequipmentagainst
dangeroussystemoverloads.Ifthetotalloadoneitherof
thePDU'soutletbanksexceeds20amps(PDUMH30NET
&PDUMH32HVNET)or15amps(PDUMH30HVNET),the
associatedcircuitbreakerwilltrip,cuttingpowertothe
entireoutletbank.Reducetheloadontheoutletbankby
unpluggingsomeequipment,thenpressthecircuit
breakerin/settotheONpositiontorestorepower.
Cord Retention Shelves (Optional): Wheninstalledon
thePDU,theseshelvesprovidesecureattachmentpoints
forconnectedequipmentpowercords.Usetheincluded
cabletiestosecurecordstotheshelf.
Mounting Brackets: Thesedetachablebracketsenable
thePDUtobeinstalledina2Urackmountconfiguration
oranunder-counterconfiguration.
Factory Port: Theportisreservedforconfigurationby
factoryauthorizedpersonnelonly.Donotconnect
anything to the port.
Ground Connection: Usethistoconnectanyequipment
that requires a chassis ground.
PS/2 Port: UsethisporttoconnectaTrippLite
ENVIROSENSEenvironmentalsensortoprovideremote
temperature/humidity monitoring and a dry contact
interfacetocontrolandmonitoralarm,securityand
telecomdevices.ContactTrippLiteCustomerSupportat
773.869.1234fororderinginformation.Note: Do not
connect a keyboard or mouse to this port.
Meter Select
Bank 2
Bank 1
LOAD (AMPS)
201105095 93-3048.indb 8 6/15/2011 3:07:30 PM
9
Features
Mini-DIN Serial Port: Usethisporttoprovideadirect
terminal connection to a computer with a terminal
emulationprogram.Aserialcable(partnumber73-1025)
isincludedwiththePDU.Ifyouneedtoordera
replacementcable,contactTrippLiteCustomerSupport
at773.869.1234.
Ethernet Port: UsethisRJ-45jacktoconnectthePDU
tothenetworkwithastandardEthernetpatchcable.The
LinkLED
A
andStatusLED
B
indicate several operating
conditions,asshowninthetablebelow.Note: This port is
not compatible with PoE (Power Over Ethernet)
applications.
Network Operating Conditions
A
Link LED Color
Off NoNetworkConnection
FlashingAmber 100MbpsNetworkConnection
FlashingGreen 10MbpsNetworkConnection
B
Status LED Color
Off CardNotInitialized
SteadyGreen CardInitializedandOperational
FlashingAmber Error-CardNotInitialized
www.tripplite.com/support
Technical Support
A B
201105095 93-3048.indb 9 6/15/2011 3:07:30 PM
10
LIMITED WARRANTY
Sellerwarrantsthisproduct,ifusedinaccordancewithallapplicableinstructions,tobefreefromoriginaldefectsinmaterial
andworkmanshipforaperiodof2years(exceptinternalUPSsystembatteriesoutsideUSAandCanada,1
year)fromthedateofinitialpurchase.Iftheproductshouldprovedefectiveinmaterialorworkmanshipwithin
thatperiod,Sellerwillrepairorreplacetheproduct,initssolediscretion.ServiceunderthisWarrantycanonly
beobtainedbyyourdeliveringorshippingtheproduct(withallshippingordeliverychargesprepaid)to:Tripp
Lite,1111W.35thStreet,Chicago,IL60609USA.Sellerwillpayreturnshippingcharges.CallTrippLite
CustomerServiceat(773)869-1234beforesendinganyequipmentbackforrepair.
THISWARRANTYDOESNOTAPPLYTONORMALWEARORTODAMAGERESULTINGFROMACCIDENT,MISUSE,
ABUSEORNEGLECT.SELLERMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYEXPRESSLY
SETFORTHHEREIN.EXCEPTTOTHEEXTENTPROHIBITEDBYAPPLICABLELAW,ALLIMPLIEDWARRANTIES,
INCLUDINGALLWARRANTIESOFMERCHANTABILITYORFITNESS,ARELIMITEDINDURATIONTOTHE
WARRANTYPERIODSETFORTHABOVE;ANDTHISWARRANTYEXPRESSLYEXCLUDESALLINCIDENTALAND
CONSEQUENTIALDAMAGES.(Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,and
somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabove
limitationsorexclusionsmaynotapplytoyou.ThisWarrantygivesyouspecificlegalrights,andyoumayhave
otherrightswhichvaryfromjurisdictiontojurisdiction).
WARNING:Theindividualusershouldtakecaretodeterminepriortousewhetherthisdeviceissuitable,
adequateorsafefortheuseintended.Sinceindividualapplicationsaresubjecttogreatvariation,the
manufacturermakesnorepresentationorwarrantyastothesuitabilityorfitnessofthesedevicesforany
specific application.
WARRANTY REGISTRATION
Visitwww.tripplite.com/warrantytodaytoregisterthewarrantyforyournewTrippLiteproduct.You'llbe
automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*
*Nopurchasenecessary.Voidwhereprohibited.Somerestrictionsapply.Seewebsitefordetails.
FCC Notice
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)
Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,
including interference that may cause undesired operation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuantto
part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful
interferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstruction
manual,maycauseharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidential
areaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterference
athisownexpense.Theusermustuseshieldedcablesandconnectorswiththisproduct.Anychangesor
modificationstothisproductnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe
user's authority to operate the equipment.
Regulatory Compliance Identification Numbers
Forthepurposeofregulatorycompliancecertificationsandidentification,yourTrippLiteproducthasbeen
assignedauniqueseriesnumber.Theseriesnumbercanbefoundontheproductnameplatelabel,alongwith
allrequiredapprovalmarkingsandinformation.Whenrequestingcomplianceinformationforthisproduct,
alwaysrefertotheseriesnumber.Theseriesnumbershouldnotbeconfusedwiththemarkingnameormodel
numberoftheproduct.
ThepolicyofTrippLiteisoneofcontinuousimprovement.Specificationsaresubjecttochangewithoutnotice.
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
201105095•933048-EN
Warranty and Warranty Registration
201105095 93-3048.indb 10 6/15/2011 3:07:30 PM
21
Manuel du propriétaire
1111 W. 35th Street • Chicago, IL 60609 USA
www.tripplite.com/support
Copyright 2010 Tripp Lite. Tous droits réservés.
PDUMH30NET
120V, 50/60Hz Input and Output c.a. entrée et sortie
PDUMH30HVNET/PDUMH30HV19NET/
PDUMH32HVNET
208/230V, 50/60Hz c.a. entrée et sortie
Unité de distribution d'alimentation (PDU) en bâti
Importantes consignes de sécurité 22
Installation 23
Configuration et fonctionnement 27
Caractéristiques 28
Assistance technique 30
Garantie 30
English 1
Español 11
201105095 93-3048.indb 21 6/15/2011 3:07:35 PM
32
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
201105095•933048-FR
201105095 93-3048.indb 32 6/15/2011 3:07:40 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Tripp Lite PDUMH32HVNET Owner's manual

Category
Power distribution units (PDUs)
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI