Miller ICE-80CX User manual

Category
Welding System
Type
User manual
Spectrum 3080
And ICE-80CX Torch
Processes
Description
Air Plasma Cutting
and Gouging
Air Plasma Cutter
OM-2225 190 009R
May 2004
R
Visit our website at
www.MillerWelds.com
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001:2000 Quality
System Standard.
Working as hard as you do
every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Mil_Thank 7/03
TABLE OF CONTENTS
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Plasma Arc Cutting Hazards 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 CONSIGNES DE SÉCURITÉ LIRE AVANT UTILISATION 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Signification des symboles 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers liés au coupage à l’arc au plasma 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Principales normes de sécurité 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Information sur les champs électromagnétiques 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 INSTALLATION 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Specifications 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Duty Cycle And Overheating 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Cutting Speed 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Selecting a Location 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Connecting Work Clamp And Gas/Air Supply 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Electrical Service Guide 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Connecting Input Power 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 OPERATION 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Controls 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Setting Gas/Air Pressure 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Sequence Of Operation 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 MAINTENANCE & TROUBLESHOOTING 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Routine Maintenance 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Trouble Lights 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Checking Shield Cup Shutdown System 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Checking/Replacing Retaining Cup, Tip, And Electrode 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Troubleshooting 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 ELECTRICAL DIAGRAM 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 PARTS LIST 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
OM-2225 Page 1
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING
pom _nd_8/03
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Plasma Arc Cutting Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-5. Read and follow all
Safety Standards.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
Y During operation, keep everybody, especially children, away.
CUTTING can cause fire or explosion.
Hot metal and sparks blow out from the cutting arc.
The flying sparks and hot metal, hot workpiece, and
hot equipment can cause fires and burns. Check
and be sure the area is safe before doing any cutting.
D Protect yourself and others from flying sparks and hot metal.
D Do not cut where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the cutting arc. If this
is not possible, tightly cover them with approved covers.
D Be alert that sparks and hot materials from cutting can easily go
through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that cutting on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not cut on closed containers such as tanks or drums.
D Connect work cable to the work as close to the cutting area as prac-
tical to prevent cutting current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Never cut containers with potentially flammable materials inside
they must be emptied and properly cleaned first.
D Do not cut in atmospheres containing explosive dust or vapors.
D Do not cut pressurized cylinders, pipes, or vessels.
D Do not cut containers that have held combustibles.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Do not locate unit on or over combustible surfaces.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any cutting.
Touching live electrical parts can cause fatal shocks
or severe burns. The torch and work circuit are
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. Plasma arc cutting requires
higher voltages than welding to start and maintain the arc (200 to 400
volts dc are common), but also uses torches designed with safety
interlock systems which turn off the machine when the shield cup is
loosened or if tip touches electrode inside the nozzle. Incorrectly
installed or improperly grounded equipment is a hazard.
ELECTRIC SHOCK can kill.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats or
covers big enough to prevent any physical contact with the work or
ground.
D Do not touch torch parts if in contact with the work or ground.
D Turn off power before checking, cleaning, or changing torch parts.
D Disconnect input power before installing or servicing this equip-
ment. Lockout/tagout input power according to OSHA CFR
1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its Owners
Manual and national, state, and local codes.
D Check and be sure that input power cord ground wire is properly
connected to ground terminal in disconnect box or that cord plug is
connected to a properly grounded receptacle outlet always verify
the supply ground.
D When making input connections, attach proper grounding conduc-
tor first.
D Frequently inspect input power cord for damage or bare wiring re-
place cord immediately if damaged bare wiring can kill.
D Turn off all equipment when not in use.
D Inspect and replace any worn or damaged torch cable leads.
D Do not wrap torch cable around your body.
D Ground the workpiece to a good electrical (earth) ground if required
by codes.
D Use only well-maintained equipment. Repair or replace damaged
parts at once.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Do not bypass or try to defeat the safety interlock systems.
D Use only torch(es) specified in Owners Manual.
D Keep away from torch tip and pilot arc when trigger is pressed.
D Clamp work cable with good metal-to-metal contact to workpiece
(not piece that will fall away) or worktable as near the cut as
practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
SIGNIFICANT DC VOLTAGE exists on
internal parts of inverter power
sources AFTER the removal of input
power.
D Turn Off unit, disconnect input power, check voltage on input ca-
pacitors, and be sure it is near zero (0) volts before touching any
parts. Check capacitors according to instructions in Mainte-
nance Section of Owner’s Manual or Technical Manual before
touching any parts.
ELECTRIC SHOCK can kill.
OM-2225 Page 2
D On inverter power sources, failed parts can ex-
plode or cause other parts to explode when
power is applied. Always wear a face shield
and long sleeves when servicing inverters.
EXPLODING PARTS can injure.
Sparks and hot metal blow out from the cutting arc.
Chipping and grinding cause flying metal.
FLYING SPARKS can cause injury.
D Wear approved face shield or safety goggles with side shields.
D Wear proper body protection to protect skin.
D Wear flame-resistant ear plugs or ear muffs to prevent sparks from
entering ears.
Arc rays from the cutting process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin.
ARC RAYS can burn eyes and skin.
D Wear face protection (helmet or shield) with correct shade of filter to
protect your face and eyes when cutting or watching. ANSI Z49.1
(see Safety Standards) suggests a No. 9 shade (with No. 8 as mini-
mum) for all cutting currents less than 300 amperes. Z49.1 adds
that lighter filter shades may be used when the arc is hidden by the
workpiece. As this is normally the case with low current cutting, the
shades suggested in Table 1 are provided for the operator’s conve-
nience.
D Wear approved safety glasses with side shields under your helmet
or shield.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather and wool) and foot protection.
Table 1. Eye Protection For Plasma Arc Cutting
Current Level In Amperes Minimum Shade Number
Below 20
20 40
40 60
60 80
#4
#5
#6
#8
Prolonged noise from some cutting applications can
damage hearing if levels exceed limits specified by
OSHA (see Safety Standards).
NOISE can damage hearing.
D Use approved ear plugs or ear muffs if noise level is high.
D Warn others nearby about noise hazard.
FUMES AND GASES can be hazardous.
Cutting produces fumes and gases. Breathing
these fumes and gases can be hazardous to
your health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use exhaust at the arc to remove
cutting fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the manufac-
turer’s instruction for metals to be cut, coatings, and cleaners.
D Work in a confined space only if it is well ventilated, or while wearing
an air-supplied respirator. Fumes from cutting and oxygen deple-
tion can alter air quality causing injury or death. Be sure the
breathing air is safe.
D Do not cut in locations near degreasing, cleaning, or spraying oper-
ations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not cut on coated metals, such as galvanized, lead, or cadmium
plated steel, unless the coating is removed from the cutting area,
the area is well ventilated, and if necessary, while wearing an air-
supplied respirator. The coatings and any metals containing these
elements can give off toxic fumes when cut.
D Do not cut containers with toxic or reactive materials inside or
containers that have held toxic or reactive materials they must be
emptied and properly cleaned first.
PLASMA ARC can cause injury.
The heat from the plasma arc can cause serious
burns. The force of the arc adds greatly to the burn
hazard. The intensely hot and powerful arc can
quickly cut through gloves and tissue.
D Keep away from the torch tip.
D Do not grip material near the cutting path.
D The pilot arc can cause burns keep away from torch tip when trig-
ger is pressed.
D Wear proper flame-retardant clothing covering all exposed body ar-
eas.
D Point torch away from your body and toward work when pressing
the torch trigger pilot arc comes on immediately.
D Turn off power source and disconnect input power before disas-
sembling torch or changing torch parts.
D Use only torch(es) specified in the Owners Manual.
Gas cylinders contain gas under high pressure. If
damaged, a cylinder can explode. Since gas cylin-
ders are normally part of metalworking processes,
be sure to treat them carefully.
CYLINDERS can explode if damaged.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flame, sparks, and arcs.
D Install and secure cylinders in an upright position by chaining them
to a stationary support or equipment cylinder rack to prevent falling
or tipping.
D Keep cylinders away from any cutting or other electrical circuits.
D Never allow electrical contact between a plasma arc torch and a
cylinder.
D Never cut on a pressurized cylinder explosion will result.
D Use only correct gas cylinders, regulators, hoses, and fittings de-
signed for the specific application; maintain them and associated
parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders, asso-
ciated equipment, and CGA publication P-1 listed in Safety
Standards.
OM-2225 Page 3
1-3. Additional Symbols For Installation, Operation, And Maintenance
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on torch.
MOVING PARTS can cause injury.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FLYING METAL can injure eyes.
D Wear safety glasses with side shields or face
shield.
MAGNETIC FIELDS can affect pacemakers.
D Pacemaker wearers keep away.
D Wearers should consult their doctor before go-
ing near plasma arc cutting operations.
OVERUSE can cause OVERHEATING.
D Allow cooling period; follow rated duty cycle.
D Reduce amperage (thickness) or reduce duty
cycle before starting to cut again.
EXPLODING HYDROGEN hazard.
D When cutting aluminum underwater or with the
water touching the underside of the aluminum,
free hydrogen gas may collect under the work-
piece.
D See your cutting engineer and water table instructions for help.
FALLING UNIT can cause injury.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift unit.
D If using lift forks to move unit, be sure forks are long enough to ex-
tend beyond opposite side of unit.
FIRE OR EXPLOSION hazard.
D Do not locate unit on, over, or near combustible
surfaces.
D Do not install unit near flammables.
D Do not overload building wiring be sure power supply system is
properly sized, rated, and protected to handle this unit.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
H.F. RADIATION can cause interference.
D High frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with elec-
tronic equipment perform this installation.
D The user is responsible for having a qualified electrician promptly
correct any interference problem resulting from the installation.
D If notified by the FCC about interference, stop using the equipment
at once.
D Have the installation regularly checked and maintained.
D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC CUTTING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D To reduce possible interference, keep cables as short as possible,
close together, and down low, such as on the floor.
D Locate cutting operation 100 meters from any sensitive electronic
equipment.
D Be sure this cutting power source is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures such
as moving the machine, using shielded cables, using line filters, or
shielding the work area.
1-4. California Proposition 65 Warnings
Y Welding or cutting equipment produces fumes or gases which
contain chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California Health &
Safety Code Section 25249.5 et seq.)
Y Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Y Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive
harm.
For Diesel Engines:
Y Diesel engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects, and
other reproductive harm.
OM-2225 Page 4
1-5. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Practices for Plasma Arc Cutting, American Welding
Society Standard AWS C5.2, from American Welding Society, 550 N.W.
LeJeune Rd, Miami, FL 33126
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale Bou-
levard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, from American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
1-6. EMF Information
Considerations About Welding Or Cutting And The Effects Of Low
Frequency Electric And Magnetic Fields
Welding or cutting current, as it flows through the welding or cutting
cables, will cause electromagnetic fields. There has been and still is
some concern about such fields. However, after examining more than
500 studies spanning 17 years of research, a special blue ribbon
committee of the National Research Council concluded that: “The body
of evidence, in the committee’s judgment, has not demonstrated that
exposure to power-frequency electric and magnetic fields is a human-
health hazard.” However, studies are still going forth and evidence
continues to be examined. Until the final conclusions of the research are
reached, you may wish to minimize your exposure to electromagnetic
fields when welding or cutting.
To reduce magnetic fields in the workplace, use the following proce-
dures:
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep cutting power source and cables as far away from operator
as practical.
5. Connect work clamp to workpiece as close to the cut as possi-
ble.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-2225 Page 8
2-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
2-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Le courant de soudage ou de coupage passant dans les câbles de puis-
sance crée des causera des champs électromagnétiques. Il y a eu et
il y a encore un certain souci à propos de tels champs. Cependant,
après avoir examiné plus de 500 études qui ont été faites pendant une
période de recherche de 17 ans, un comité spécial ruban bleu du Natio-
nal Research Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs ma-
gnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les
conclusions finales de la recherche soient établies, il vous serait sou-
haitable de réduire votre exposition aux champs électromagnétiques
pendant le soudage ou le coupage.
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1 Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
2 Mettre tous les câbles du côté opposé de l’opérateur.
3 Ne pas courber pas et ne pas entourer pas les câbles autour de
vous.
4 Garder le poste de soudage et les câbles le plus loin possible de
vous.
5 Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les consignes mentionnées précédemment font partie de celles desti-
nées aux personnes ayant recours à un stimulateur cardiaque. Veuillez
consulter votre médecin pour obtenir plus de détails.
OM-2225 Page 9
SECTION 3 INSTALLATION
3-1. Specifications
Amperes Input at
Rated Load
Output 60 Hz
Rated
Output
Type of
Output
Plasma
Gas
Rated
Cutting
Capacity
Maximum
Open-Circuit
Voltage DC
230 V 460 V KVA KW
Output
Output
Gas
C
apac
it
y
V
o
lt
age
DC
Single-
Phase
63 −− 14.6 13.9
80 A @ 140
Volts DC,
40% Duty
Cycle
Direct
Current,
Straight
7.2 CFM
(204 L/min)
At 80 PSI
(552 kPa)
7/8 in
(22 mm)
350
3-Phase 35 18 14.1 13.4
80 A @ 140
Volts DC,
60% Duty
Cycle
Straight
Polarity
(DCEN)
(552 kP
a
)
Air Or
Nitrogen
Only
(
22 mm
)
At 10 IPM
3
5
0
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before cutting.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
Three-Phase Input Power:
60% Duty Cycle
Overheating
0
15
A
OR
Reduce Duty Cycle
Minutes
duty1 4/95
Single-Phase Input Power:
40% Duty Cycle
4 Minutes Cutting 6 Minutes Resting
6 Minutes Cutting 4 Minutes Resting
OM-2225 Page 10
3-3. Cutting Speed
The cutting speed curve shows the
recommended maximum cutting
speed capabilities of the power
source and torch for mild steel of
various thickness.
Y Exceeding recommended
cutting speeds will cause
rapid erosion of the tip and
electrode.
191 831
Cutting speed is approximately
10 inches per minute at 0.88 in
(22 mm) mild steel thickness at
max setting/tip saver mode.
OM-2225 Page 11
3-4. Selecting a Location
loc_2 3/96 - 802 140 / Ref. 151 556
1 Lifting Handles
Use handles to lift unit.
2 Hand Cart
Use cart or similar device to move
unit.
3 Rating Label
Use rating label to determine input
power needs.
4 Line Disconnect Device
Locate unit near correct input
power supply.
Y Special installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or CEC
Section 20.
24 in
(610 mm)
17 in
(432 mm)
12-1/2 in
(318 mm)
Movement
1
1
2
Y Do not move or operate unit
where it could tip.
Location
4
3
Dimensions And Weight
18 in
(460 mm)
18 in
(460 mm)
74 lb (34.6 kg)
OM-2225 Page 12
3-5. Connecting Work Clamp And Gas/Air Supply
Ref. 803 640-A / 802 201-B
1 Work Clamp
2 Workpiece
Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.
. Use only clean, dry air supply
with 90 to 150 psi pressure.
Torch requires 80 psi pressure.
3 Gas/Air Inlet Opening
4 Hose
Use hose with an inside diameter of
at least 3/8 in. If hose is over 40 ft
(12.2 m) in length, use hose with 1/2
in inside diameter.
5 Teflon Tape
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
Adjust gas/air pressure according
to Section 4-2.
Tools Needed:
5/8, 1-1/8 in
From Gas/Air Supply
3
4
5
Rear of
Unit
1
2
3-6. Electrical Service Guide
Single Phase Three Phase
Input Voltage 230 230 460
Input Amperes At Rated Output 63 35 18
Max Recommended Standard Fuse Rating In Amperes
Circuit Breaker
1
, Time-Delay
2
70 40 20
Normal Operating 3 100 50 25
Min Input Conductor Size In AWG/Kcmil 8 10 14
Max Recommended Input Conductor Length In Feet (Meters)
71
(22)
97
(30)
152
(46)
Min Grounding Conductor Size In AWG/Kcmil 8 10 14
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
OM-2225 Page 13
3-7. Connecting Input Power
L1
input_2 3/96 - Ref. ST-144 221 / Ref. 070 399-C / 802 140
Check input voltage available at
site.
. The Auto-Link circuitry in this
unit automatically links the
power source to the primary
voltage being applied, either
230 or 460 volts ac.
1 Input And Grounding
Conductors
2 Line Disconnect Device
See Section 3-6.
For single-phase operation:
3 Black And White Input
Conductor
4 Red Input Conductor
5 Insulation Sleeving
6 Electrical Tape
Insulate and isolate red conductor
as shown.
Y Always connect green wire
to supply grounding termi-
nal, never to a line terminal.
Connect black, white, and
red wires (L1, L2, L3) to line
terminals.
3/8 in
3/8 in
2
2
1
1
1
3
1
6
5
4
L2
L3
L1
L2
Y Always connect grounding
conductor first.
1
3
= GND/PE
Tools Needed:
Green
Green
Green
OM-2225 Page 14
SECTION 4 OPERATION
1 Gas/Air Pressure Gauge
2 Gas/Air Pressure Adjustment Knob
3 Output Control
Use control to set cutting output.
Gas/air automatically flows at the set
pressure.
Use Gas/Air Set area of control range for set-
ting gas/air pressure (see Section 4-2).
4 Trouble Lights (see Section 5-2)
Power light comes On when Power switch is
placed in On position.
5 Power Light
6 Ready Light
Ready light comes On when unit is On to indi-
cate that all safety shutdown systems are
okay. If Ready light does not come On, check
trouble lights.
7 Trigger Hold Switch
To cut without holding torch trigger, depress
upper end of Trigger Hold switch, press trig-
ger to pilot, transfer torch to work, and release
torch trigger within five seconds. To stop cut-
ting, press and release trigger.
When lower end of Trigger Hold switch is de-
pressed, trigger must be held closed while
cutting.
8 Torch Quick-Disconnect Connector
9 Power Switch
10 Door for Consumables Storage
4-1. Controls
Ref. 187 861 / Ref. 802 201-B
10
9
Rear of
Unit
8
1
2
7
4
5
6
3
20
40
60
80
160
140
120
100
OM-2225 Page 15
1 Output Control
2 Power Switch
Place controls as indicated. Only gas/air cir-
cuit is activated when the Power switch is
turned On with Output Control in Gas/Air Set
position.
3 Gas/Air Pressure Adjustment Knob
Pull knob and turn to adjust pressure. Push
knob in to lock setting.
Select desired cutting output with Output
Control.
4-2. Setting Gas/Air Pressure
Ref. 802 140 / Ref. 802 201-B
1
Set Controls Turn On Gas/Air Supply Adjust Pressure
On Unit
Select Desired
Amperage To Be-
gin Cutting
Set To 80 PSI
Requires
90150 PSI Supply
Setting Gas/Air Pressure
Place Output Control in
Gas/Air Set Position
Power Switch On
Rear of
Unit
2
3
OM-2225 Page 16
4-3. Sequence Of Operation
Put On Personal
Safety
Equipment
After cutting arc starts, slowly
start moving torch across metal.
Adjust torch speed so
sparks go thru metal and
out bottom of cut.
Pause briefly at end of
cut before releasing trigger.
Install &
Connect
Equipment
EXAMPLE Of Cutting Operation
801 400-A
Press trigger. Pilot arc starts.
Postflow continues for approx. 20 to
30 seconds after releasing trigger;
cutting arc can be instantly
restarted during postflow by
pressing trigger.
Check Torch Tip,
Electrode, And
Retaining Cup
Check Gas/Air
Pressure
Set
Controls
Begin
Cutting
Turn On
Power Source
The pilot arc starts immediately when
trigger is pressed.
Place drag shield on edge of metal,
or allow correct standoff distance
approximately 1/8 in (3 mm).
Do not clean torch by hitting it against a
hard surface. Hitting hard surfaces can
damage torch parts and stop proper opera-
tion.
Inspect shield cup, tip, and electrode for
wear before cutting or whenever cutting
speed has been significantly reduced (see
torch Owners Manual). Do not operate
torch without a tip or electrode in place.
OM-2225 Page 17
SECTION 5 MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
Y Disconnect power
before maintaining.
. Maintain more often
during severe conditions.
Each Use
Check Torch
Tip, Electrode,
And Shield Cup
Check Gas/Air
Pressure
Every Week
Check Shield
Cup Shutdown
System
3 Months
Service Air
Filter/Regulator
Assembly Filter
Replace
Unreadable
Labels
Tape Torn Outer
Covering Or
Replace Cable
Replace
Cracked
Parts
Check
Gas/Air Hose
Check Torch
Body
6 Months
Blow Out Or
Vacuum Inside
OR
OM-2225 Page 18
5-2. Trouble Lights
1 Pressure Light
Lights if gas/air pressure is below
60 PSI (414 kPa).
Turn power Off, and check for prop-
er gas/air pressure (see Section
4-2).
2 Cup Light
Lights if shield cup is loose.
Turn power Off, and check shield
cup connection (see torch Owners
Manual). Power must be reset
whenever the cup shutdown is
activated.
Check shield cup shutdown system
once a week (see Section 5-3).
3 Temperature Light
Lights if power source overheats
(see Section 3-2).
1
2
3
Difficulty establishing pilot arc may indicate
consumables need to be cleaned or replaced.
5-3. Checking Shield Cup Shutdown System
Ref. 801 300-A
1 Torch Shield Cup
Turn Power On and loosen shield
cup. If shutdown system works
properly, Ready light goes off and
Cup light comes on. If not, immedi-
ately turn Off power and have Fac-
tory Authorized Service Agent
check safety control board PC1 op-
eration.
If system works properly, retighten
cup and reset power.
1
. Power must be reset whenever the cup shutdown
system is activated. Always turn Off power when
changing or checking consumables.
OM-2225 Page 19
5-4. Checking/Replacing Retaining Cup, Tip, And Electrode
Overtightening will strip threads. Do not overtighten electrode, tip, and retaining
cup during assembly. Do not cross-thread parts causing stripping. Use care dur-
ing torch assembly and parts replacement.
Inspect shield cup, tip, and electrode for wear before cutting or whenever cutting speed has been significantly
reduced. Do not operate torch without a tip or electrode in place. Be sure to use genuine replacement parts.
A good practice is to replace both the tip and electrode at the same time.
Ref. 801 396-A / 801 405
Turn Off power source.
1 Drag Shield
2 Retaining Cup
Remove retaining cup. Check retaining cup
for cracks, and replace if necessary.
3Tip
4 Opening
Remove tip. Check tip, and replace if open-
ing is deformed or 50% oversize. If inside of
tip is not clean and bright, clean with steel
wool. Be sure to remove any pieces of steel
wool afterwards.
5 Electrode
Check electrode. If center has a pit more
than a 1/16 in (2 mm) deep, remove and re-
place electrode.
6 Swirl Ring
Remove swirl ring. Check ring, and replace
if side holes are plugged.
7 O-Ring
Check O-rings on torch. If needed, coat with
thin film of silicone lubricant (part no.
169 231). Replace if damaged.
8 Plunger Area
Check this area for any debris or foreign ma-
terial. Clean out if necessary.
Carefully reassemble parts in reverse order.
Make sure this area is clean of
any debris.
Turn Off power source before checking torch parts.
New
Worn
New
Worn
5
1/16 in
(2 mm)
Pit
4
3
8
7
6
2
1
OM-2225 Page 20
5-5. Troubleshooting
Trouble Remedy
No pilot arc; difficulty in establishing an
arc.
Clean or replace worn consumables as necessary (see torch Owner’s Manual).
Check for damaged torch or torch cable (see torch Owner’s Manual).
No cutting output; Power light off;
Trouble lights off; Ready light off; fan mo-
tor FM does not run.
Place Power switch in On position.
Place line disconnect device in On position (see Section 3-7).
Check line fuse(s) and replace if needed or reset circuit breakers (see Sections 3-6 and 3-7).
Pilot arc working; no cutting output; Pow-
er light on; Ready light on; Trouble lights
off; fan motor running.
Be sure work clamp is connected.
Clean or replace worn consumables as necessary (see torch Owners Manual).
No gas/air flow; Power light on; Ready
light on; Trouble lights off; fan motor
running.
Have Factory Authorized Service Agent check for proper torch connections. Check operation of gas
valve GS1, and check gas/air system for leaks.
Pressure Trouble light On; Ready light
off.
Check for correct gas/air pressure adjustment (see Section 4-2).
Check for sufficient gas/air supply pressure (see Section 3-5).
Check for dirty air filter/regulator and clean, if needed (see manufacturers instructions).
Check air lines for leaks.
Have Factory Authorized Service Agent check pressure switch and control board.
Cup Trouble light On; Ready light off. Check torch shield cup (see Section 5-3). Reset power switch.
Have Factory Authorized Service Agent check for proper torch connections.
Temperature Trouble light On; Ready
light off.
Inverter heat sink or output heat sink overheating. Allow fan to run; the Trouble light goes out when the
unit has cooled.
Have Factory Authorized Service Agent check control board.
Trouble lights not working. Have Factory Authorized Service Agent check unit.
Power light flashing, Trouble lights off. Reset power switch.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Miller ICE-80CX User manual

Category
Welding System
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages