Miller Electric OM-1500-4 Owner's manual

Category
Welding System
Type
Owner's manual

This manual is also suitable for

SuitCase 8RC
OM-1500-16 210 243AA
2011−05
Processes
Description
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Wire Feeder
File: MIG (GMAW)
Visit our website at
www.MillerWelds.com
CE And Non-CE Models
R
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001 Quality System
Standard.
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Mil_Thank 2009−09
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1...................................
1-1. Symbol Usage 1........................................................................
1-2. Arc Welding Hazards 1..................................................................
1-3. Additional Symbols For Installation, Operation, And Maintenance 3.............................
1-4. California Proposition 65 Warnings 4.......................................................
1-5. Principal Safety Standards 4.............................................................
1-6. EMF Information 4......................................................................
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION 5............................
2-1. Symboles utilisés 5.....................................................................
2-2. Dangers relatifs au soudage à l’arc 5......................................................
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance 7......
2-4. Proposition californienne 65 Avertissements 8...............................................
2-5. Principales normes de sécurité 9..........................................................
2-6. Informations relatives aux CEM 9.........................................................
SECTION 3 − DEFINITIONS 11...................................................................
3-1. Warning Label Definitions 11..............................................................
3-2. WEEE Label (For Products Sold Within The EU) 12...........................................
3-3. Symbols And Definitions 12...............................................................
SECTION 4 − INSTALLATION 13..................................................................
4-1. Important Information Regarding CE Products (Sold Within The EU) 13...........................
4-2. Serial Number And Rating Label Location 13.................................................
4-3. Specifications 13........................................................................
4-4. 14-Pin Plug Information 13................................................................
4-5. Gun Recommendation Table 14............................................................
4-6. Equipment Connection Diagram 14.........................................................
4-7. Installing And Aligning Wire Guide And Drive Rolls 15.........................................
4-8. Connecting Welding Gun 16...............................................................
4-9. Connecting Shielding Gas 17..............................................................
4-10. Connecting Weld Cable 17................................................................
4-11. Weld Cable Sizes* 18....................................................................
4-12. Installing And Threading Welding Wire 19....................................................
SECTION 5 − OPERATION 20....................................................................
5-1. Controls 20.............................................................................
5-2. Controls For Meter (Optional) 21...........................................................
5-3. Setting Digital Meter Board PC4 DIP Switches 22.............................................
5-4. Gun Consumables Information 23..........................................................
SECTION 6 − MAINTENANCE & TROUBLESHOOTING 24...........................................
6-1. Routine Maintenance 24..................................................................
6-2. Overload Protection And Thermostat Protection 24............................................
6-3. Troubleshooting 25......................................................................
SECTION 7 − ELECTRICAL DIAGRAMS 26........................................................
SECTION 8 − PARTS LIST 28.....................................................................
WARRANTY
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product
Stock Number
SUITCASE 8 RC W/CE, EURO, TRIGGERHOLD 300660003
Council Directives:
2006/95/EC Low Voltage
2004/108/EC Electromagnetic Compatibility
Standards:
IEC 609741:2005 Arc welding equipment – Part 1: Welding power sources
IEC 609745:2007 Arc welding equipment – Part 5: Wire feeders
IEC 6097410:2007 Arc Welding Equipment – Part 10: Electromagnetic compatibility (EMC) requirements
EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding, arc
welding and allied processes with the basic restrictions related to human exposure to electromagnetic fields
(0 Hz – 300Hz)
Signatory:
_____________________________________
___________________________________________
David A. Werba
Date of Declaration
MANAGER, PRODUCT DESIGN COMPLIANCE
January 26, 2011
241469C
OM-1500-16 Page 1
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2011−01
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or ex-
plained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult sym-
bols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shock
s
or severe burns. The electrode and work circuit i
s
electrically live whenever the output is on. The inpu
t
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automati
c
wire welding, the wire, wire reel, drive roll housing
,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperl
y
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoid-
able or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit volt-
age. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter weld-
ing power sources AFTER removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on equip-
ment.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-1500-16 Page 2
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
ARC RAYS can burn eyes and skin.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or by-
pass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off compressed gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EM
F)
can affect Implanted Medical Devices.
D Wearers of Pacemakers and other Implante
d
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their docto
r
and the device manufacturer before going near arc welding, spo
t
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient num-
ber of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
OM-1500-16 Page 3
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manu-
ally lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can injure.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained.
D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-1500-16 Page 4
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproduc-
tive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Glob-
al Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 4221 Walney Road, 5th Floor,
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, web-
site: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (phone: 301-504-7923, website:
www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The Na-
tional Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may inter-
fere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, access restrictions for passers−by or individual risk assess-
ment for welders. All welders should use the following procedures in
order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recom-
mended.
OM-1500-16 Page 9
2-5. Principales normes de sécuri
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, de Global
Engineering Documents (téléphone : 1-877-413-5184, site internet :
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, de National Fire Protec-
tion Association, Quincy, MA 02269 (téléphone : 800-344-3555, site
Internet : www.nfpa.org et www.sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chan-
tilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, de Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (téléphone :
800-463-6727, site internet : www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protec-
tion, ANSI Standard Z87.1, de American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (téléphone : 212-642-4900,
site Internet : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General
Industry, Title 29, Code of Federal Regulations (CFR), Part 1910,
Subpart Q, and Part 1926, Subpart J, de U.S. Government Printing
Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA
15250-7954 (téléphone : 1-866-512-1800) (il y a 10 bureaux
régionaux−le téléphone de la région 5, Chicago, est 312-353-2220, site
Internet : www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (téléphone : 301-504-7923, site inter-
net : www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The
National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (télé[hone : 1-800-232-4636, site internet:
www.cdc.gov/NIOSH).
2-6. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant de soudage
crée un CEM autour du circuit et du matériel de soudage. Les CEM
peuvent créer des interférences avec certains implants médicaux
comme des stimulateurs cardiaques. Des mesures de protection pour
les porteurs d’implants médicaux doivent être prises: par exemple, des
restrictions d’accès pour les passants ou une évaluation individuelle
des risques pour les soudeurs. Tous les soudeurs doivent appliquer les
procédures suivantes pour minimiser l’exposition aux CEM provenant
du circuit de soudage:
1. Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
2. Ne pas se tenir au milieu des câbles de soudage. Disposer les
câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber et ne pas entourer les câbles autour de votre
corps.
4. Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
6. Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
7. Ne pas souder tout en portant la source de soudage ou le
dévidoir.
En ce qui concerne les implants médicaux :
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induc-
tion. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-1500-16 Page 11
SECTION 3 − DEFINITIONS
3-1. Warning Label Definitions
1 1.1 1.2 1.3
3 3.1 3.2 3.3
4 4.1
+
2
2.1
2.2
+
+
56
+
2.3
S-178 936
Warning! Watch Out! There are
possible hazards as shown by the
symbols.
Drive rolls can injure fingers
Welding wire and drive parts are at
welding voltage during operation −
keep hands and metal objects
clear.
1 Electric shock can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
1.2 Protect yourself from electric
shock by insulating yourself
from work and ground.
1.3 Disconnect input plug or
power before working on
machine.
2 Breathing welding fumes can
be hazardous to your health.
2.1 Keep your head out of the
fumes.
2.2 Use forced ventilation or local
exhaust to remove the fumes.
2.3 Use ventilating fan to remove
fumes.
3 Welding sparks can cause
explosion or fire.
3.1 Keep flammables away from
welding. Don’t weld near
flammables.
3.2 Welding sparks can cause
fires. Have a fire extinguisher
nearby and have a watch
person ready to use it.
3.3 Do not weld on drums or any
closed containers.
4 Arc rays can burn eyes and
injure skin.
4.1 Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
5 Become trained and read the
instructions before working on
the machine or welding.
6 Do not remove or paint over
(cover) the label.
OM-1500-16 Page 12
3-2. WEEE Label (For Products Sold Within The EU)
Do not discard product (where ap-
plicable) with general waste.
Reuse or recycle Waste Electrical
and Electronic Equipment (WEEE)
by disposing at a designated collec-
tion facility.
Contact your local recycling office
or your local distributor for further
information.
3-3. Symbols And Definitions
. Some symbols are found only on CE products.
Output Input
A
Amperes
V
Volts
X
Duty Cycle Wire Feed Percent
IP
Degree Of Protec-
tion
Input
Cold Jog (Inch) To-
wards Workpiece
Purge By Gas Fast
Constant Current Circuit Breaker Constant Voltage Slow
Trigger Hold Off Trigger Hold On
I
2
Rated Welding
Current
Increase
Read Instructions
U
1
Primary Voltage
U
2
Conventional Load
Voltage Hz
Hertz
I
1
Primary Current
OM-1500-16 Page 13
SECTION 4 − INSTALLATION
4-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
B. Information On Electromagnetic Compatibility (EMC)
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
ce-emc 3 2010-10
4-2. Serial Number And Rating Label Location
The serial number and rating information for this product is located inside the cover. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
4-3. Specifications
Type of
Input
Power
Welding
Power
Source
Type
Wire Feed
Speed
Range
Wire
Diameter
Range
Input
Welding
Circuit
Rating
IP
Rating
Max. Wire
Spool
Capacity
Overall
Dimensions
Weight
24 Volts AC
Single Phase
7 Amperes
50/60 Hz
Constant
Voltage (CV)
DC With
14-Pin And
Contactor
Control
50 to 700 ipm
(1.3 To 17.8
mpm)
.023 To 5/64 in.
(0.6 To 2 mm)
100 Volts,
400
Amperes,
60%
Duty Cycle
23
14 lb (6.4 kg),
8 in. (203 mm)
Length: 18 in.
(457 mm)
Width: 7-1/4 in.
(184 mm)
Height: 12-3/4 in.
(324 mm)
22 lb
(10 kg)
4-4. 14-Pin Plug Information
Pin* Pin Information
AJ
B
K
I
C
L
NH
D
M
G
E
F
A 24 volts AC with respect to socket G.
B Contact closure to A completes 24 volts AC contactor control circuit.
G Circuit common for 24 volts AC circuit.
C +10 volts DC input from power source to wire feeder with respect to socket D.
D Remote control circuit common.
E 0 to +10 volts DC output signal from wire feeder to power source with respect to socket D.
H Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
F Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
*The remaining pins are not used.
OM-1500-16 Page 14
4-5. Gun Recommendation Table
Process Gun
GMAW − Hard or Cored Wires Bernard Q300 or Q400
FCAW − Self-Shielding Wires FC-1260, Dura-Flux
4-6. Equipment Connection Diagram
805 126-A
1 Constant Voltage (CV)
Welding Power Source
Supplying 24 VAC To Feeder
Use optional PSA-2 adapter for
power sources having only 115
VAC supply.
2 Negative (−) Weld Cable
3 Positive (+) Weld Cable
4 Workpiece
5 Interconnecting Cord
(Customer Supplied)
6 14-Pin Plug And Cord
7 Wire Feeder
8 Gun
9 Gun Trigger Receptacle
10 Gas Hose
11 Gas Cylinder
. Shielding gas pressure not to
exceed 100 psi (689 kPa).
1
2
3
4
5
6
7
8
9
10
11
OM-1500-16 Page 15
4-7. Installing And Aligning Wire Guide And Drive Rolls
Installing Wire Guide And Drive
Rolls:
1 Drive Securing Roll Nut
2 Drive Roll Carrier
Turn nut one click until lobes of nut
line up with lobes of drive roll carrier.
3 Drive Roll
Slide drive roll onto drive roll carrier.
Turn nut one click.
Repeat procedure for top drive roll.
4 Inlet Wire Guide Screw
5 Inlet Wire Guide
Loosen securing screw. Align inlet
guide so inlet guide screw is
centered in groove in guide, or so tip
is as close to drive rolls as possible
without touching. Tighten screw.
Aligning Wire Guide And Drive
Rolls:
View is from top of drive rolls look-
ing down with pressure assembly
open.
6 Drive Roll Securing Nut
7 Drive Roll
8 Inlet Wire Guide
9 Welding Wire
10 Drive Gear
Turn screw in or out until drive roll
groove lines up with wire guide.
Close pressure roll assembly.
Only bottom drive roll alignment is
adjustable. Turn adjustment screw
in or out until groove in drive roll
lines up with wire guide as shown.
Cleaning Drive Rolls:
Remove drive rolls, and clean
grooves using a wire brush.
Tools Needed:
3/16 in.
Aligning Wire Guide And Drive Rolls
Correct Incorrect
8
7
6
10
9
1
2
3
4
5
Installing Wire Guide
And Drive Rolls
805 127-C / Ref. 132 808-F / Ref. 162 079-A / Ref. 180 967
OM-1500-16 Page 16
4-8. Connecting Welding Gun
246 102 / Ref. 805 129-B / 805 130-B
! Turn Off wire feeder and
welding power source.
Stop engine on welding
generator.
1 Gun Securing Knob
2 Gun Block
3 Gun Power Pin
4 Power Pin Groove
5 Gun Locking Tab
Loosen knob, insert gun end into
block. Position power pin as
close as possible to drive rolls
without touching. Align the gun
power pin groove with the gun
locking tab. Tighten knob.
6 Gun Trigger Plug
7 Gun Trigger Receptacle
Connect gun trigger plug to gun
trigger receptacle.
3
6
7
Internal Side View
Gun Locking Tab In Place
Gun Locking Tab
Out Of Place
5
5
4
2
1
OM-1500-16 Page 17
4-9. Connecting Shielding Gas
805 128-A
1 Gas Hose With 5/8-18
Right-hand Thread Fittings
(Customer Supplied)
2 Shielding Gas Cylinder
. Shielding gas pressure not to
exceed 100 psi (689 kPa).
3 Valve
4 Flowmeter
5 14-Pin Plug
Close valve on cylinder when fin-
ished welding.
Tools Needed:
5/8 in.
1
Rear View
2
3
4
5
4-10. Connecting Weld Cable
Ref. 132 808-F / Ref. 805 130-B
1 User-Suppled Weld Cable
Follow wire manufacturer’s recom-
mendations for weld cable polarity.
2 User-Suppled Male Connector
3 User-Suppled Female
Connector
Push female connector over male
connector, and turn 1/4 turn clock-
wise.
2
1
3
From Wire Feeder
Internal Side View
OM-1500-16 Page 18
4-11. Weld Cable Sizes*
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
! Turn off power befor
e
connecting to weld ou
t-
put terminals.
! Do not use worn, dam
-
aged, undersized, o
r
poorly spliced cables
.
Weld Output
Terminals
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 − 60%
Duty
Cycle
AWG (mm
2
)
60 − 100%
Duty
Cycle
AWG (mm
2
)
10 − 100% Duty Cycle
AWG (mm
2
)
100 4 (20) 4 (20) 4 (20) 3 (30) 2 (35) 1 (50) 1/0 (60) 1/0 (60)
150 3 (30) 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 3/0 (95)
200 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 4/0 (120)
250 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500 2/0 (70) 3/0 (95) 4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart)
Ref. S-0007-G 2009−08
OM-1500-16 Page 19
4-12. Installing And Threading Welding Wire
805 127-C / Ref. ST-159 048-A / S-0627-A
Installing Wire And Adjusting
Hub Tension:
1 Retaining Nut
2 Hub Tension Adjustment Nut
Remove retaining ring, and install
spool so hub pin fits spool hole. Re-
install retaining nut.
Adjust tension knob so only a slight
force is needed to turn spool.
. Do not over tighten tension
knob. It is not necessary to use
any tools to tighten the knob.
Threading Welding Wire:
3 Pressure Assembly
Adjustment Knob
Lay gun cable out straight.
Open pressure assembly, hold wire
tightly, and cut off end. Push wire
through guides into gun.
Close and tighten pressure assem-
bly. Press Jog switch until wire
comes out gun.
To set the proper drive roll tension,
release the tension on the drive
rolls. Position gun at about a 45 de-
gree angle, with nozzle about two
inches from a wooden surface. In-
crease the tension while feeding
the wire against the wooden sur-
face to one half turn past the point
where the wire stops slipping. If the
wire slips at maximum hand tight
tension there may be other prob-
lems. Check the gun liner, spool
tension, contact tips, drive roll wear,
drive roll alignment and inlet guide
as all these can cause feeding
problems.
Cut off wire, and close door.
Pull and hold wire; cut off end.
6 in.
(150 mm)
1
2
3
WOOD
Tighten
Clockwise
. Hold wire tightly
to keep it from
unraveling.
OM-1500-16 Page 20
SECTION 5 − OPERATION
5-1. Controls
1 Power Control Switch
2 Snap-In Blank
3 Voltage Control
4 Wire Speed Control
Use control to adjust wire speed
within range selected by switch.
5 Purge Switch
Press switch to momentarily ener-
gize gas solenoid and purge air
from gun, and to adjust shielding
gas regulator.
6 Jog Switch
Use Jog position to momentarily
feed welding wire at speed set on
Wire Speed control without ener-
gizing welding circuit or shielding
gas valve.
Close and latch door.
Internal Control Panel
Internal Side View
JOG
Ref. 805 130-B / 234 520-A
Front Panel
V
V
24VWireFeeder
1
OFF
ON
PURGE
HOLD
OFF
POWER
ON
VOLTAGE WIRE SPEED
2
4
6
8
1
2
3
4
5
6
18 m/min
7 ipm x 100
0
3
5
8
10
13
15
2
4
3
6
Internal Control Panel
PURGE
5
OM-1500-16 Page 21
5-2. Controls For Meter (Optional)
1 Power Control Switch
2 Trigger Hold Switch
Depress the left part of the switch
(turns trigger hold On) to weld with-
out holding gun trigger throughout
the weld cycle.
To start weld, press and release
gun trigger. To end weld, press and
release gun trigger.
Depress the right part of the trigger
hold switch to turn trigger hold Off.
3 Meter Display
4 Volts, Wire Feed Speed Or
Amps Select Switch
. Meter is factory set to display
voltage and wirefeed speed. To
display voltage and amps refer
to Section 5-3 for DIP switch
settings.
5 Voltage Control
6 Wire Speed Control
Use control to adjust wire speed
within range selected by switch.
Close and latch door.
Ref. 805 131-B / 251 045-A
Front Panel
V
1
VOLTAGE WIRE SPEED
2
4
6
8
1
2
3
4
5
6
18 m/min
7 ipm x 100
0
3
5
8
10
13
15
2
6
5
V
V
A
OFF
ON
POWER
ON OFF
HOLD
3
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Miller Electric OM-1500-4 Owner's manual

Category
Welding System
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI