Dell iDRAC6 for Monolithic Servers Version 1.3 User guide

  • Hello! I am an AI chatbot trained to assist you with the Dell iDRAC6 for Monolithic Servers Version 1.3 User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Integrated Dell
â„¢
Remote
Access Controller 6 (iDRAC6)
Version 1.3
User Guide
Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
___________________
Information in this document is subject to change without notice.
© 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, OpenManage, and PowerEdge, are trademarks of
Dell Inc.; Microsoft, Windows, Windows Server, .NET, Internet Explorer, Windows Vista, and Active
Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States
and/or other countries; Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat,
Inc. in the United States and other countries; SUSE is a registered trademark of Novell Corporation;
Intel and Pentium are registered trademarks of Intel Corporation in the United States and other
countries; UNIX is a registered trademark of The Open Group in the United States and other countries;
Java is a trademark or registered trademark of Sun Microsystems, Inc. or its subsidiaries in the United
States and other countries.
Copyright 1998-2009 The OpenLDAP Foundation. All rights reserved. Redistribution and use in
source and binary forms, with or without modification, are permitted only as authorized by the
OpenLDAP Public License. A copy of this license is available in the file LICENSE in the top-level
directory of the distribution or, alternatively, at www.OpenLDAP.org/license.html. OpenLDAP is a
registered trademark of the OpenLDAP Foundation. Individual files and/or contributed packages may
be copyrighted by other parties and subject to additional restrictions. This work is derived from the
University of Michigan LDAP v3.3 distribution. This work also contains materials derived from public
sources. Information about OpenLDAP can be obtained at www.openldap.org/. Portions Copyright
1998-2004 Kurt D. Zeilenga. Portions Copyright 1998-2004 Net Boolean Incorporated. Portions
Copyright 2001-2004 IBM Corporation. All rights reserved. Redistribution and use in source and
binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public
License. Portions Copyright 1999-2003 Howard Y.H. Chu. Portions Copyright 1999-2003 Symas
Corporation. Portions Copyright 1998-2003 Hallvard B. Furuseth. All rights reserved. Redistribution
and use in source and binary forms, with or without modification, are permitted provided that this
notice is preserved. The names of the copyright holders may not be used to endorse or promote products
derived from this software without their specific prior written permission. This software is provided
"as is'' without express or implied warranty. Portions Copyright (c) 1992-1996 Regents of the
University of Michigan. All rights reserved. Redistribution and use in source and binary forms are
permitted provided that this notice is preserved and that due credit is given to the University of Michigan
at Ann Arbor. The name of the University may not be used to endorse or promote products derived
from this software without specific prior written permission. This software is provided "as is'' without
express or implied warranty. Other trademarks and trade names may be used in this document to refer
to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary
interest in trademarks and trade names other than its own.
December 2009
Contents 3
Contents
1 iDRAC6 Overview. . . . . . . . . . . . . . . . . . . 29
iDRAC6 Express Management Features. . . . . . . . . 29
iDRAC6 Enterprise and VFlash Media
. . . . . . . . . . 31
Supported Platforms . . . . . . . . . . . . . . . . . . . 34
Supported Operating Systems
. . . . . . . . . . . . . . 35
Supported Web Browsers
. . . . . . . . . . . . . . . . 35
Supported Remote Access Connections
. . . . . . . . 35
iDRAC6 Ports
. . . . . . . . . . . . . . . . . . . . . . . 35
Other Documents You May Need
. . . . . . . . . . . . 36
2 Getting Started With the iDRAC6 . . . . . . 39
3 Basic Installation of the iDRAC6
. . . . . . . 41
Before You Begin . . . . . . . . . . . . . . . . . . . . 41
Installing the iDRAC6 Express/Enterprise Hardware
. . 41
Configuring Your System to Use an iDRAC6
. . . . . . . 42
Software Installation and Configuration Overview
. . . 44
Installing Your iDRAC6 Software
. . . . . . . . . . 44
Configuring Your iDRAC6
. . . . . . . . . . . . . . 44
4 Contents
Installing the Software on the Managed System . . . . 45
Installing the Software on the Management Station
. . 45
Installing and Removing RACADM on a
Linux Management Station
. . . . . . . . . . . . . 45
Installing RACADM
. . . . . . . . . . . . . . . . . 46
Uninstalling RACADM
. . . . . . . . . . . . . . . . 46
Updating the iDRAC6 Firmware
. . . . . . . . . . . . . 47
Before You Begin
. . . . . . . . . . . . . . . . . . 47
Downloading the iDRAC6 Firmware
. . . . . . . . 47
Updating the iDRAC6 Firmware Using the
Web-Based Interface
. . . . . . . . . . . . . . . . 48
Updating the iDRAC6 Firmware Using
RACADM
. . . . . . . . . . . . . . . . . . . . . . 48
Updating the iDRAC6 Firmware Using
Dell Update Packages for Supported
Windows and Linux Operating Systems
. . . . . . 48
Clearing the Browser Cache
. . . . . . . . . . . . 49
Configuring a Supported Web Browser
. . . . . . . . . 49
Configuring Your Web Browser to
Connect to the iDRAC6 Web-Based Interface
. . . 49
List of Trusted Domains
. . . . . . . . . . . . . . . 49
32-bit and 64-bit Web Browsers
. . . . . . . . . . 50
Viewing Localized Versions of the
Web-Based Interface
. . . . . . . . . . . . . . . . 50
4 Configuring the iDRAC6 Using
the Web Interface
. . . . . . . . . . . . . . . . . . 53
Accessing the Web Interface . . . . . . . . . . . . . . 54
Logging In
. . . . . . . . . . . . . . . . . . . . . . 55
Logging Out
. . . . . . . . . . . . . . . . . . . . . 56
Using Multiple Browser
Tabs and Windows
. . . . . . . . . . . . . . . . . 56
Contents 5
Configuring the iDRAC6 NIC . . . . . . . . . . . . . . . 57
Configuring the Network and
IPMI LAN Settings
. . . . . . . . . . . . . . . . . 57
Configuring IP Filtering and
IP Blocking
. . . . . . . . . . . . . . . . . . . . . 63
Configuring Platform Events
. . . . . . . . . . . . . . . 65
Configuring Platform Event Filters (PEF)
. . . . . . 66
Configuring Platform Event Traps (PET)
. . . . . . 67
Configuring E-Mail Alerts
. . . . . . . . . . . . . . 68
Configuring IPMI
. . . . . . . . . . . . . . . . . . 69
Configuring iDRAC6 Users
. . . . . . . . . . . . . . . . 71
Securing iDRAC6 Communications Using
SSL and Digital Certificates
. . . . . . . . . . . . . . . 71
Secure Sockets Layer (SSL)
. . . . . . . . . . . . 72
Certificate Signing Request (CSR)
. . . . . . . . . 72
Accessing SSL Through the
Web-Based Interface
. . . . . . . . . . . . . . . . 73
Generating a Certificate Signing Request
. . . . . 73
Uploading a Server Certificate
. . . . . . . . . . . 75
Configuring and Managing Active Directory
. . . . . . 77
Configuring and Managing Generic LDAP
. . . . . . . 80
Configuring iDRAC6 Services
. . . . . . . . . . . . . . 80
Updating the iDRAC6 Firmware/System
Services Recovery Image
. . . . . . . . . . . . . . . . 84
iDRAC6 Firmware Rollback
. . . . . . . . . . . . . 85
Remote Syslog
. . . . . . . . . . . . . . . . . . . . . . 86
First Boot Device
. . . . . . . . . . . . . . . . . . . . . 88
6 Contents
5 Advanced iDRAC6 Configuration . . . . . . 89
Before You Begin. . . . . . . . . . . . . . . . . . . . . 89
Configuring iDRAC6 for Viewing Serial
Output Remotely Over SSH/Telnet
. . . . . . . . . . . . 89
Configuring the iDRAC6 Settings to
Enable SSH/Telnet
. . . . . . . . . . . . . . . . . 90
Starting a Text Console Through
Telnet or SSH
. . . . . . . . . . . . . . . . . . . . 90
Using a Telnet Console
. . . . . . . . . . . . . . . 91
Using the Secure Shell (SSH)
. . . . . . . . . . . . 93
Configuring Linux for Serial Console
Redirection During Boot
. . . . . . . . . . . . . . 94
Configuring iDRAC6 for Serial Connection
. . . . . . . 99
Configuring iDRAC for Direct Connect
Basic Mode and Direct Connect
Terminal Mode
. . . . . . . . . . . . . . . . . . 101
Switching Between RAC Serial Interface
Communication Mode and Serial
Console Redirection
. . . . . . . . . . . . . . . 103
Connecting the DB-9 or Null Modem Cable
for the Serial Console
. . . . . . . . . . . . . . . . . 104
Configuring the Management Station
Terminal Emulation Software
. . . . . . . . . . . . . 105
Configuring Linux Minicom for Serial
Console Emulation
. . . . . . . . . . . . . . . . 105
Configuring HyperTerminal for Serial
Console Redirection
. . . . . . . . . . . . . . . 107
Configuring Serial and Terminal Modes
. . . . . . . . 108
Configuring IPMI and iDRAC6 Serial
. . . . . . . 108
Configuring Terminal Mode
. . . . . . . . . . . . 110
Configuring the iDRAC6 Network Settings
. . . . . . 111
Contents 7
Accessing the iDRAC6 Through a Network . . . . . . . 111
Using RACADM Remotely
. . . . . . . . . . . . . . . . 113
RACADM Synopsis
. . . . . . . . . . . . . . . . . 114
RACADM Options
. . . . . . . . . . . . . . . . . . 115
Enabling and Disabling the RACADM
Remote Capability
. . . . . . . . . . . . . . . . . . . . 116
RACADM Subcommands
. . . . . . . . . . . . . . 116
Frequently Asked Questions About
RACADM Error Messages
. . . . . . . . . . . . . 118
Configuring Multiple iDRAC6 Controllers
. . . . . . . . 118
Creating an iDRAC6 Configuration File
. . . . . . . 120
Parsing Rules
. . . . . . . . . . . . . . . . . . . . 122
Modifying the iDRAC6 IP Address
. . . . . . . . . 124
Configuring iDRAC6 Network Properties
. . . . . . 125
Frequently Asked Questions about
Network Security
. . . . . . . . . . . . . . . . . . . . 127
6 Adding and Configuring
iDRAC6 Users
. . . . . . . . . . . . . . . . . . . . 129
Using the Web Interface to Configure
iDRAC6 Users
. . . . . . . . . . . . . . . . . . . . . . 129
Adding and Configuring iDRAC6 Users
. . . . . . . 129
Public Key Authentication over SSH
. . . . . . . . 133
Uploading, Viewing, and Deleting
SSH Keys Using the iDRAC6
Web-Based Interface
. . . . . . . . . . . . . . . . 136
Uploading, Viewing, and Deleting
SSH Keys Using RACADM
. . . . . . . . . . . . . 137
Using the RACADM Utility to
Configure iDRAC6 Users
. . . . . . . . . . . . . . . . . 138
8 Contents
Before You Begin . . . . . . . . . . . . . . . . . 138
Adding an iDRAC6 User
. . . . . . . . . . . . . . 139
Removing an iDRAC6 User
. . . . . . . . . . . . 140
Enabling an iDRAC6 User
With Permissions
. . . . . . . . . . . . . . . . . 140
7 Using the iDRAC6 Directory
Service
. . . . . . . . . . . . . . . . . . . . . . . . . 143
Using iDRAC6 With Microsoft Active Directory. . . . 143
Prerequisites for Enabling Active
Directory Authentication for the iDRAC6
. . . . . . . 144
Supported Active Directory
Authentication Mechanisms
. . . . . . . . . . . . . . 144
Extended Schema Active Directory Overview
. . . . 145
Extending the Active Directory Schema
. . . . . 145
Active Directory Schema Extensions
. . . . . . . 145
Overview of the iDRAC Schema Extensions
. . . 146
Active Directory Object Overview
. . . . . . . . 146
Accumulating Privileges Using
Extended Schema
. . . . . . . . . . . . . . . . . 148
Configuring Extended Schema Active
Directory to Access Your iDRAC
. . . . . . . . . 149
Installing the Dell Extension to the
Microsoft Active Directory Users
and Computers Snap-In
. . . . . . . . . . . . . . 155
Adding iDRAC Users and Privileges
to Microsoft Active Directory
. . . . . . . . . . . 156
Configuring Microsoft Active Directory
With Extended Schema Using the
iDRAC6 Web-Based Interface
. . . . . . . . . . 158
Configuring Microsoft Active Directory
With Extended Schema Using RACADM
. . . . . 161
Contents 9
Standard Schema Active Directory
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . 164
Single Domain Versus Multiple
Domain Scenarios
. . . . . . . . . . . . . . . . . 165
Configuring Standard Schema Microsoft
Active Directory to Access iDRAC6
. . . . . . . . 166
Configuring Microsoft Active Directory
With Standard Schema Using the iDRAC6
Web-Based Interface
. . . . . . . . . . . . . . . . 166
Configuring Microsoft Active Directory
With Standard Schema Using RACADM
. . . . . . 169
Testing Your Configurations
. . . . . . . . . . . . . . . 172
Enabling SSL on a Domain Controller
. . . . . . . . . . 172
Exporting the Domain Controller
Root CA Certificate to the iDRAC6
. . . . . . . . . 173
Importing the iDRAC6 Firmware
SSL Certificate
. . . . . . . . . . . . . . . . . . . 174
Using Microsoft Active Directory to Log
In to the iDRAC6
. . . . . . . . . . . . . . . . . . . . . 175
Using Microsoft Active Directory Single Sign-On
. . . 176
Configuring the iDRAC6 to Use Single Sign-On
. . 176
Logging Into the iDRAC6 Using Single Sign-On
. . 177
Generic LDAP Directory Service
. . . . . . . . . . . . 177
Login Syntax (Directory User versus
Local User)
. . . . . . . . . . . . . . . . . . . . . 178
Configuring Generic LDAP Directory
Service Using the iDRAC6 Web-Based
Interface
. . . . . . . . . . . . . . . . . . . . . . 178
Configuring Generic LDAP Directory
Service Using RACADM
. . . . . . . . . . . . . . 181
Frequently Asked Questions about Active Directory . . 182
10 Contents
8 Configuring Smart Card
Authentication
. . . . . . . . . . . . . . . . . . . . 187
Configuring Smart Card Login in iDRAC6 . . . . . . . 187
Configuring Local iDRAC6 Users for
Smart Card Logon
. . . . . . . . . . . . . . . . . . . 188
Exporting the Smart Card Certificate
. . . . . . . 188
Configuring Active Directory Users for
Smart Card Logon
. . . . . . . . . . . . . . . . . . . 189
Configuring Smart Card
. . . . . . . . . . . . . . . . 189
Logging Into the iDRAC6 Using the
Smart Card
. . . . . . . . . . . . . . . . . . . . . . . 191
Logging Into the iDRAC6 Using Active
Directory Smart Card Authentication
. . . . . . . . . 192
Troubleshooting the Smart Card
Logon in iDRAC6
. . . . . . . . . . . . . . . . . . . . 192
9 Enabling Kerberos Authentication . . . . 195
Prerequisites for single sign-on and
Active Directory Authentication
Using Smart Card
. . . . . . . . . . . . . . . . . . . . 196
Configuring the iDRAC6 for single sign-on
and Active Directory Authentication
Using Smart Card
. . . . . . . . . . . . . . . . . . . . 198
Configuring Active Directory Users for
single sign-on Logon
. . . . . . . . . . . . . . . . . . 198
Logging Into the iDRAC6 Using single
sign-on for Active Directory Users
. . . . . . . . . . 199
Contents 11
Configuring Active Directory Users
for Smart Card Logon
. . . . . . . . . . . . . . . . . . 199
10 Using GUI Console Redirection . . . . . . . 201
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 201
Using Console Redirection
. . . . . . . . . . . . . . . 201
Configuring Your Management Station
. . . . . . . 202
Clear Your Browser’s Cache
. . . . . . . . . . . . 203
Supported Screen Resolutions
and Refresh Rates
. . . . . . . . . . . . . . . . . 204
Configuring Console Redirection
in the iDRAC6 Web Interface
. . . . . . . . . . . . 205
Opening a Console Redirection Session
. . . . . . 207
Using iDRAC6 KVM (Video Viewer)
. . . . . . . . . . . 209
Disabling or Enabling Local Server Video
. . . . . 213
Launching vKVM and Virtual Media Remotely
. . . . . 214
URL Format
. . . . . . . . . . . . . . . . . . . . . 214
General Error Scenarios
. . . . . . . . . . . . . . 214
Frequently Asked Questions on
Console Redirection
. . . . . . . . . . . . . . . . . . . 215
11 Using the WS-MAN Interface . . . . . . . . 219
Supported CIM Profiles . . . . . . . . . . . . . . . . . 219
12 Using the iDRAC6 SM-CLP
Command Line Interface
. . . . . . . . . . . . 223
iDRAC6 SM-CLP Support . . . . . . . . . . . . . . . . 223
12 Contents
SM-CLP Features. . . . . . . . . . . . . . . . . . . . 224
Using SM-CLP
. . . . . . . . . . . . . . . . . . . 224
SM-CLP Targets
. . . . . . . . . . . . . . . . . . 224
13 Deploying Your Operating
System Using VMCLI
. . . . . . . . . . . . . . . 231
Before You Begin. . . . . . . . . . . . . . . . . . . . 231
Remote System Requirements
. . . . . . . . . . 231
Network Requirements
. . . . . . . . . . . . . . 231
Creating a Bootable Image File
. . . . . . . . . . . . 232
Creating an Image File for Linux Systems
. . . . 232
Creating an Image File for
Windows Systems
. . . . . . . . . . . . . . . . 232
Preparing for Deployment
. . . . . . . . . . . . . . . 232
Configuring the Remote Systems
. . . . . . . . . 232
Deploying the Operating System
. . . . . . . . . . . . 233
Using the VMCLI Utility
. . . . . . . . . . . . . . . . 234
Installing the VMCLI Utility
. . . . . . . . . . . . 235
Command Line Options
. . . . . . . . . . . . . . 235
VMCLI Parameters
. . . . . . . . . . . . . . . . 236
VMCLI Operating System Shell Options
. . . . . 239
14 Configuring Intelligent Platform
Management Interface (IPMI)
. . . . . . . 241
Configuring IPMI . . . . . . . . . . . . . . . . . . . . 241
Configuring IPMI Using the
Web-Based Interface
. . . . . . . . . . . . . . . 241
Contents 13
Configuring IPMI Using the
RACADM CLI
. . . . . . . . . . . . . . . . . . . . 242
Using the IPMI Remote Access
Serial Interface
. . . . . . . . . . . . . . . . . . . 246
Configuring Serial Over LAN Using
the Web-Based Interface
. . . . . . . . . . . . . . . . 246
15 Configuring and Using
Virtual Media
. . . . . . . . . . . . . . . . . . . . 247
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 247
Windows-Based Management Station
. . . . . . 248
Linux-Based Management Station
. . . . . . . . . 249
Configuring Virtual Media
. . . . . . . . . . . . . . . . 249
Running Virtual Media
. . . . . . . . . . . . . . . . . . 251
Supported Virtual Media Configurations
. . . . . . 251
Booting From Virtual Media
. . . . . . . . . . . . 253
Installing Operating Systems
Using Virtual Media
. . . . . . . . . . . . . . . . 254
Using Virtual Media When the Server’s
Operating System Is Running
. . . . . . . . . . . . 255
Frequently Asked Questions about Virtual Media
. . . 256
16 Configuring the VFlash Media
Card for Use With iDRAC6
. . . . . . . . . . 261
Configuring the VFlash Media Card Using
the iDRAC6 Web Interface
. . . . . . . . . . . . . . . . 261
SD Card Properties
. . . . . . . . . . . . . . . . . 261
VFlash Drive
. . . . . . . . . . . . . . . . . . . . 264
Viewing the Virtual Flash Key Size
. . . . . . . . . 264
14 Contents
Configuring the VFlash Media Card
Using RACADM
. . . . . . . . . . . . . . . . . . . . . 265
Enabling or Disabling the VFlash
Media Card
. . . . . . . . . . . . . . . . . . . . 265
Resetting the VFlash Media Card
. . . . . . . . . 265
17 Power Monitoring and
Management
. . . . . . . . . . . . . . . . . . . . . 267
Power Inventory, Power Budgeting, and Capping . . 268
Power Monitoring
. . . . . . . . . . . . . . . . . . . 268
Configuring and Managing Power
. . . . . . . . . . . 268
Viewing the Health Status of the
Power Supply Units
. . . . . . . . . . . . . . . . . . 269
Using the Web-Based Interface
. . . . . . . . . 269
Using RACADM
. . . . . . . . . . . . . . . . . . 270
Viewing Power Budget
. . . . . . . . . . . . . . . . 270
Using the Web Interface
. . . . . . . . . . . . . 270
Using RACADM
. . . . . . . . . . . . . . . . . . 271
Power Budget Threshold
. . . . . . . . . . . . . . . 271
Using the Web-Based Interface
. . . . . . . . . 272
Using RACADM
. . . . . . . . . . . . . . . . . . 272
Viewing Power Monitoring
. . . . . . . . . . . . . . 273
Using the Web Interface
. . . . . . . . . . . . . 273
Executing Power Control Operations
on the Server
. . . . . . . . . . . . . . . . . . . . . . 275
Using the Web Interface
. . . . . . . . . . . . . 275
Using RACADM
. . . . . . . . . . . . . . . . . . 276
Contents 15
18 Using the iDRAC6
Configuration Utility
. . . . . . . . . . . . . . . 277
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 277
Starting the iDRAC6 Configuration Utility
. . . . . . . . 278
Using the iDRAC6 Configuration Utility
. . . . . . . . . 278
iDRAC6 LAN
. . . . . . . . . . . . . . . . . . . . . 279
IPMI Over LAN
. . . . . . . . . . . . . . . . . . . 279
LAN Parameters
. . . . . . . . . . . . . . . . . . 280
Virtual Media Configuration
. . . . . . . . . . . . 283
Smart Card Logon
. . . . . . . . . . . . . . . . . . 284
System Services Configuration
. . . . . . . . . . . 284
LCD Configuration
. . . . . . . . . . . . . . . . . 285
LAN User Configuration
. . . . . . . . . . . . . . 286
Reset to Default
. . . . . . . . . . . . . . . . . . . 286
System Event Log Menu
. . . . . . . . . . . . . . 286
Exiting the iDRAC6 Configuration Utility
. . . . . . 289
19 Monitoring and Alert Management . . . . 291
Configuring the Managed System to
Capture the Last Crash Screen
. . . . . . . . . . . . . 291
Disabling the Windows Automatic Reboot Option
. . . 292
Disabling the Automatic Reboot
Option in Windows 2008 Server
. . . . . . . . . . 292
Disabling the Automatic Reboot
Option in Windows Server 2003
. . . . . . . . . . 292
Configuring Platform Events
. . . . . . . . . . . . . . . 292
Configuring Platform Event Filters (PEF)
. . . . . . 293
Configuring PET
. . . . . . . . . . . . . . . . . . . 295
Configuring E-Mail Alerts
. . . . . . . . . . . . . . 296
16 Contents
Testing E-mail Alerting . . . . . . . . . . . . . . 297
Testing the RAC SNMP Trap Alert Feature
. . . . 298
Frequently Asked Question about
SNMP Authentication
. . . . . . . . . . . . . . . . . 298
20 Recovering and Troubleshooting
the Managed System
. . . . . . . . . . . . . . . 301
First Steps to Troubleshoot a Remote System . . . . . 301
Managing Power on a Remote System
. . . . . . . . 301
Selecting Power Control Actions from
the iDRAC6 Web-Based Interface
. . . . . . . . 301
Selecting Power Control Actions
from the iDRAC6 CLI
. . . . . . . . . . . . . . . 302
Viewing System Information
. . . . . . . . . . . . . . 302
Main System Chassis
. . . . . . . . . . . . . . . 302
Remote Access Controller
. . . . . . . . . . . . 304
Using the System Event Log (SEL)
. . . . . . . . . . . 306
Using the Command Line to
View System Log
. . . . . . . . . . . . . . . . . 307
Using the POST Boot Logs
. . . . . . . . . . . . . . . 308
Viewing the Last System Crash Screen
. . . . . . . . 309
21 Recovering and Troubleshooting
the iDRAC6
. . . . . . . . . . . . . . . . . . . . . . 311
Using the RAC Log . . . . . . . . . . . . . . . . . . . 311
Using the Command Line
. . . . . . . . . . . . . . . . 313
Using the Diagnostics Console
. . . . . . . . . . . . 313
Contents 17
Using Identify Server . . . . . . . . . . . . . . . . . . 314
Using the Trace Log
. . . . . . . . . . . . . . . . . . . 315
Using the racdump
. . . . . . . . . . . . . . . . . . . . 315
Using the coredump
. . . . . . . . . . . . . . . . . . . 315
22 Sensors . . . . . . . . . . . . . . . . . . . . . . . . . 317
Battery Probes . . . . . . . . . . . . . . . . . . . . . . 317
Fan Probes
. . . . . . . . . . . . . . . . . . . . . . . . 317
Chassis Intrusion Probes
. . . . . . . . . . . . . . . . 317
Power Supplies Probes
. . . . . . . . . . . . . . . . . 318
Power Monitoring Probes
. . . . . . . . . . . . . . . . 318
Temperature Probe
. . . . . . . . . . . . . . . . . . . . 318
Voltage Probes
. . . . . . . . . . . . . . . . . . . . . . 318
23 Configuring Security Features . . . . . . . 321
Security Options for the iDRAC6 Administrator . . . . . 322
Disabling the iDRAC6 Local Configuration
. . . . . 322
Disabling iDRAC6 Remote Virtual KVM
. . . . . . . 324
Securing iDRAC6 Communications Using
SSL and Digital Certificates
. . . . . . . . . . . . . . . 325
Secure Sockets Layer (SSL)
. . . . . . . . . . . . 325
Certificate Signing Request (CSR)
. . . . . . . . . 325
Accessing the SSL Main Menu
. . . . . . . . . . 326
Generating a Certificate Signing Request
. . . . . 327
Viewing a Server Certificate
. . . . . . . . . . . . 328
18 Contents
Using the Secure Shell (SSH) . . . . . . . . . . . . . 329
Configuring Services
. . . . . . . . . . . . . . . . . . 329
Enabling Additional iDRAC6 Security Options
. . . . 333
Configuring the Network Security
Settings Using the iDRAC6 GUI
. . . . . . . . . . 337
A RACADM Subcommand Overview . . . . . 339
help . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
arp
. . . . . . . . . . . . . . . . . . . . . . . . . . . 340
clearasrscreen
. . . . . . . . . . . . . . . . . . . . . 340
config
. . . . . . . . . . . . . . . . . . . . . . . . . . 341
getconfig
. . . . . . . . . . . . . . . . . . . . . . . . 343
coredump
. . . . . . . . . . . . . . . . . . . . . . . . 346
coredumpdelete
. . . . . . . . . . . . . . . . . . . . 347
fwupdate
. . . . . . . . . . . . . . . . . . . . . . . . 348
getssninfo
. . . . . . . . . . . . . . . . . . . . . . . 350
getsysinfo. . . . . . . . . . . . . . . . . . . . . . . . 352
getractime
. . . . . . . . . . . . . . . . . . . . . . . 357
ifconfig
. . . . . . . . . . . . . . . . . . . . . . . . . 358
netstat
. . . . . . . . . . . . . . . . . . . . . . . . . 358
ping
. . . . . . . . . . . . . . . . . . . . . . . . . . . 359
setniccfg
. . . . . . . . . . . . . . . . . . . . . . . . 359
Contents 19
getniccfg . . . . . . . . . . . . . . . . . . . . . . . . . 361
getsvctag
. . . . . . . . . . . . . . . . . . . . . . . . . 362
racdump
. . . . . . . . . . . . . . . . . . . . . . . . . 363
racreset
. . . . . . . . . . . . . . . . . . . . . . . . . 364
racresetcfg
. . . . . . . . . . . . . . . . . . . . . . . . 365
serveraction
. . . . . . . . . . . . . . . . . . . . . . . 366
getraclog
. . . . . . . . . . . . . . . . . . . . . . . . . 367
clrraclog . . . . . . . . . . . . . . . . . . . . . . . . . 369
getsel
. . . . . . . . . . . . . . . . . . . . . . . . . . . 369
clrsel
. . . . . . . . . . . . . . . . . . . . . . . . . . . 370
gettracelog
. . . . . . . . . . . . . . . . . . . . . . . . 371
sslcsrgen
. . . . . . . . . . . . . . . . . . . . . . . . . 372
sslcertupload
. . . . . . . . . . . . . . . . . . . . . . 374
sslcertdownload
. . . . . . . . . . . . . . . . . . . . . 375
sslcertview
. . . . . . . . . . . . . . . . . . . . . . . . 377
sslkeyupload
. . . . . . . . . . . . . . . . . . . . . . . 379
testemail
. . . . . . . . . . . . . . . . . . . . . . . . . 380
testtrap . . . . . . . . . . . . . . . . . . . . . . . . . . 381
vmdisconnect
. . . . . . . . . . . . . . . . . . . . . . 383
vmkey
. . . . . . . . . . . . . . . . . . . . . . . . . . 384
usercertupload
. . . . . . . . . . . . . . . . . . . . . . 384
20 Contents
usercertview . . . . . . . . . . . . . . . . . . . . . . 386
localConRedirDisable
. . . . . . . . . . . . . . . . . 387
krbkeytabupload
. . . . . . . . . . . . . . . . . . . . 387
sshpkauth
. . . . . . . . . . . . . . . . . . . . . . . 388
B iDRAC6 Property Database
Group and Object Definitions
. . . . . . . . . . . 391
Displayable Characters . . . . . . . . . . . . . . . . 391
idRacInfo
. . . . . . . . . . . . . . . . . . . . . . . . 392
idRacProductInfo (Read Only)
. . . . . . . . . . 392
idRacDescriptionInfo (Read Only)
. . . . . . . . 392
idRacVersionInfo (Read Only)
. . . . . . . . . . . 392
idRacBuildInfo (Read Only)
. . . . . . . . . . . . 393
idRacName (Read Only)
. . . . . . . . . . . . . 393
idRacType (Read Only)
. . . . . . . . . . . . . . 393
cfgLanNetworking
. . . . . . . . . . . . . . . . . . . 394
cfgNicIPv4Enable (Read/Write)
. . . . . . . . . . 394
cfgNicSelection (Read/Write)
. . . . . . . . . . 394
cfgNicVLanEnable (Read/Write)
. . . . . . . . . 395
cfgNicVLanId (Read/Write)
. . . . . . . . . . . . 396
cfgNicVLanPriority (Read/Write)
. . . . . . . . . 396
cfgDNSDomainNameFromDHCP (Read/Write)
. . 396
cfgDNSDomainName (Read/Write)
. . . . . . . . 397
cfgDNSRacName (Read/Write)
. . . . . . . . . . 397
cfgDNSRegisterRac (Read/Write)
. . . . . . . . 398
cfgDNSServersFromDHCP (Read/Write)
. . . . . 398
cfgDNSServer1 (Read/Write)
. . . . . . . . . . . 398
cfgDNSServer2 (Read/Write)
. . . . . . . . . . . 399
cfgNicEnable (Read/Write)
. . . . . . . . . . . . 399
/