Omega LVE115/116 Series Owner's manual

Category
Motorcycle Accessories
Type
Owner's manual

Omega LVE115/116 Series is an Electro-Optic Level Switch designed to detect the level of liquids in a variety of industrial applications. With its robust construction and advanced features, this device offers reliable and accurate liquid level monitoring.

Key Capabilities:

  • Versatile Mounting: Can be mounted horizontally or up to 45° from horizontal, providing flexibility in installation.
  • Wide Operating Range: Operates in temperatures from -40°F to 212°F (-40°C to 100°C) and pressures up to 2500 psig.
  • Open Collector Output: Provides a 18 mA sink maximum output for easy integration with control systems.

Omega LVE115/116 Series is an Electro-Optic Level Switch designed to detect the level of liquids in a variety of industrial applications. With its robust construction and advanced features, this device offers reliable and accurate liquid level monitoring.

Key Capabilities:

  • Versatile Mounting: Can be mounted horizontally or up to 45° from horizontal, providing flexibility in installation.
  • Wide Operating Range: Operates in temperatures from -40°F to 212°F (-40°C to 100°C) and pressures up to 2500 psig.
  • Open Collector Output: Provides a 18 mA sink maximum output for easy integration with control systems.
LVE 115/116 Series
Electro-Optic Level Switch
Installation:
1b 1/ 2 " NPT S wi t c h : Ap p l y a c uri ng t yp e t h re a d seal ant (s u c h as Loc-
ti te #56 5 wi t h prim e r "N" ), which is com p ati bl e wi t h th e liquid me d i a .
W e d o no t re c o m mend pipe t ap e . F or C a r b on Steel units t o rq u e one to
tw o tu rns (m a xi m u m ) past th e ha n d - ti g h t eng a gem e n t . For St a i n l e s s
Steel u ni t s t o r qu e on e tur n (m a xim u m ) past t h e han d - t i g h t en g a g e-
ment.Over T or q u e o f s e ns o r c an p e r m an e n t l y d a m ag e s e n s o r .
2. S e ns o r ma y be in s t a l l e d ho r i zo n t a l l y or up to 45 ° from hor i zont a l ,
on l y. ( S e e Fi g u r e 1 )
3. D o n o t i n s t al l s e n s o r c l os e t o i nf r a r e d s o u rc e s .
4. P ri s m s u r f a c e m u s t b e at l e a st 2" f r o m a n y reflective s u r f a c es .
5. Connect appropri a t e v o l t a g e suppl y t o red l ead. Fo r 1 2 V DC un i t s ,
con n e c t t o 1 2 V D C ± 5 % .
6. In d u c t i v e l o a ds m us t b e d i o de - s up p r ess e d .
7.
Maintenance:
Sensor may require a periodic cleaning of prism surface. A mild detergent may be
used to clean prism surface.
This product complies with EN61326 Electrical Equipment for Measurement, Control
and Laboratory use - EMC Requirements for Minimum Requirements and Industrial
Locations. Special caution should be taken to meet EN61000-4-5 Surge Immunity if
any of the following conditions apply to the installation: The product is installed
outside; the cable is greater than 30 meters in length. In order to meet the Surge
Immunity requirements, the following conditions must be followed during installation:
1. Shielded cable must be used, and the shield must be tied to earth ground (not
power supply ground) on at least one end of the cable shield/drain
wire. The shield must be maintained all the way from sensor to the
power supply.
2. If unshielded cable is used, an earth grounded metal conduit can
be used to replace the shielded cable.
3. For the sensor with metal body or enclosure the body/enclosure must be ground-
ed to earth. If a protective metal housing is used, the metal housing should be
grounded to earth.
4. If a protective plastic housing is used, the housing must be able to withstand at
least 2 kV from the housing to earth ground.
Important Points:
· Omega products must be maintained and installed in strict accordance with the
National Electrical Code and the applicable Omega Product Instruction Bulletin that
covers installation, operation and proper maintenance. Failure to observe this infor-
mation may result in serious injury or damages.
· For hazardous area applications involving such things as, but not limited to, ignita-
ble mixtures, combustible dust and flammable materials, use an appropriate explo-
sionproof enclosure or intrinsically safe interface device.
· Please adhere to the pressure and temperature limitations shown throughout this
catalog for our level and flow sensors. These limitations must not be exceeded.
These pressures and temperatures take into consideration possible system surge
pressures, temperatures and their frequencies.
· Selection of materials for compatibility with the media is critical to the life and
operation of Omega products. Take care in the proper selection of materials of
construction, testing is required.
· Our sensors have been designed to resist shock and vibration. However, shock
and vibration should be minimized.
· Filter liquid media containing particulate and/or debris to ensure the proper opera-
tion of our products.
· Electrical entries and mounting points in an enclosed tank may require liquid/
vaporsealing.
· Our sensors must not be field-repaired.
· Physical damage sustained by product may render it unserviceable.
M-5175/1112
Specifications
Materials:
Housing
Nickel-Plated Carbon Steel
Prism Fused Glass
Operating Pressure 0 to 2500 psig, Max
Operating Temperature -40°F to 212°F (-40°C to 100°C)
Current Consumption 12V ~34mA No Load
Output Open Collector Output,
18 mA Sink Max.
Electrical Termination 22 AWG, Polymeric, 12” to 14” Extended Lead
Wires
Repeatability ±1 mm
Approvals Units Labeled
C.E. EN 61326
Note: Not for use in freezing liquids.
These units must be
mounted horizontally
or up to 45° from
Mounting Attitude
1/2” NPT Thread Mounting
Typical Wiring Dia-
+12 VDC
+12 VDC
Max Ambient Light
Black Container Opaque Container
390 FT-CD 30 FT-CD
Note:
Above testing is based on minimum readings
of at least two (2) samples.
The test depicted to the left was performed to
determine the sensor immunity level to
ambient light. The recorded ambient is the
239576 rev B
  • Page 1 1
  • Page 2 2

Omega LVE115/116 Series Owner's manual

Category
Motorcycle Accessories
Type
Owner's manual

Omega LVE115/116 Series is an Electro-Optic Level Switch designed to detect the level of liquids in a variety of industrial applications. With its robust construction and advanced features, this device offers reliable and accurate liquid level monitoring.

Key Capabilities:

  • Versatile Mounting: Can be mounted horizontally or up to 45° from horizontal, providing flexibility in installation.
  • Wide Operating Range: Operates in temperatures from -40°F to 212°F (-40°C to 100°C) and pressures up to 2500 psig.
  • Open Collector Output: Provides a 18 mA sink maximum output for easy integration with control systems.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI