Nortek Contol WOR User manual

Type
User manual

This manual is also suitable for

INSTR,INST,WOR
Linear P/N: 212902 C
Material: 20 Lb. Mead Bond
Size: 8.500" x 11.000"
Ink: Black
Side 1 of 2
Scale: 1-1
WOR
Wiegand
Output
Receiver
Installation
Instructions
INTRODUCTION
The Model WOR remote radio receiver is designed for use as an access control interface for Linear’s block coded
digital transmitters. The unit receives signals from transmitters, adds a facility code to the data, and sends the
information to the Wiegand input of the access control panel via a 5-wire connection.
Several transmitter and receiver options can be set using the unit’s dipswitches. Three different Wiegand output
formats (26, 30, & 31-bit) are supported. Three receiver options (lockout, hold, & button offset) can be set.
Transmitter buttons on multi-button units can be selectively disabled. The facility code is set using 16 dipswitches.
Three antenna types can be used with this receiver. The local whip antenna (supplied) screws directly on to the
receiver. The directional (EXA-2000) and omni-directional (EXA-1000) remote antennas attach to the receiver’s
antenna input via RG-59 cable and a type “F” connector.
An on-board RADIO RANGE knob allows adjustment of the receiver’s gain. It can be set to limit the maximum
radio range that the receiver can achieve. Two indicators display the receivers performance and operation. The
red RADIO indicator lights when the receiver detects a radio signal. The two color red/green STATUS indicator
lights green when the receiver is sending Wiegand data and during the 1-second post receiver lockout timer (if
receiver lockout is enabled). The indicator turns red when the receiver’s HOLD input (connected to the access
control panel) is active. Receiver test points are provided for listening to the incoming signals with an audio
amplifier.
Power input to the receiver can be either regulated 5 volts or 8-24 volts DC (jumper selected).
The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and
a weather-tight wiring strain relief seal the unit from the elements.
1. OPEN CASE 2. LOCATE COMPONENTS
3. SET VOLTAGE INPUT JUMPER 4. SET OUTPUT FORMAT & RECEIVER OPTIONS
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
OPEN CASE FROM
ANTENNA END
REMOVE FOUR
SCREWS AND WASHERS
BOARD SLIDES OUT
FROM 3RD SLOT UP
INSIDE CASE
5. SET TRANSMITTER FACILITY CODE 6. SET TRANSMITTER BUTTON OPTIONS
ANTENNA
CONNECTOR
(HIDDEN)
RADIO RANGE KNOB
(CLOCKWISE FOR
MAXIMUM GAIN)
MAX
RADIO
TEST POINTS
GND
AUDIO
RADIO INDICATOR
STATUS INDICATOR
RED = HOLD, GREEN = DECODE
POWER AND
DATA TERMINALS
OPTION
DIPSWITCHES
INPUT
VOLTAGE
JUMPER
PROGRAM
BUTTON
PLACE VOLTAGE INPUT JUMPER
IN THIS POSITION TO SELECT A
REGULATED 5 VOLT DC INPUT
FROM THE ACCESS CONTROL
PANEL
PLACE VOLTAGE INPUT JUMPER
IN THIS POSITION TO SELECT A
8-24 VOLT DC INPUT FROM THE
ACCESS CONTROL PANEL
SELECT THE WIEGAND OUTPUT FORMAT
THAT MATCHES THE ACCESS CONTROL
SYSTEM BEING USED
SWITCH 1 26-BIT
SWITCH 2 30-BIT
SWITCH 3 31-BIT
RECEIVER OPTIONS
WIEGAND OUTPUT FORMAT
SWITCH 1 - LOCKOUT DISABLE
SWITCH 2 - HOLD ENABLE
SWITCH 3 - BUTTON OFFSET ENABLE
OFF
- (FACTORY SETTING) CAUSES RECEIVER TO IGNORE TRANSMITTER SIGNALS FOR ONE SECOND AFTER A VALIDATED TRANSMISSION.
ON
- ALLOWS RECEIVER TO PASS WIEGAND DATA INSTANTLY WITH EACH VALIDATED TRANSMISSION.
OFF
- (FACTORY SETTING) HOLD INPUT SIGNALS ARE IGNORED.
ON
- WHEN HOLD INPUT IS ACTIVE, ANY WIEGAND DATA WILL BE HELD FOR A MAXIMUM OF ONE SECOND THEN DISCARDED UNLESS THE
HOLD INPUT IS RELEASED DURING THE ONE SECOND TIME.
OFF
- (FACTORY SETTING) TRANSMITTERS PASS THEIR ID NUMBER TO THE WIEGAND OUTPUT WITHOUT ANY CHANGES.
ON
- THE TRANSMITTER ID IS OFFSET TO THE RANGE ABOVE, BASED ON WHICH BUTTON IS PRESSED.
BUTTON OFFSET TABLE
LEFT
RIGHT
TOP
BOTTOM LEFT OR RIGHT
0
16384 32768 49152
= S W I T C H O N
SET XMTR FACILITY CODE
SWITCHES TO MATCH THE FACILITY
CODE PRE-PROGRAMMED INTO
TRANSMITTER BLOCK
NOTE: THE FACTORY SETTINGS
OF FACILITY CODE "0" WILL
ALLOW VALIDATION OF ANY
TRANSMITTER FACILITY CODE
S W T 0
S W T 1
S W T 2
S W T 3
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
0
TRANSMITTER BLOCK
FACILITY CODE 0-15
(ASSIGNED WHEN
TRANSMITTER BLOCK IS
ORDERED FROM LINEAR)
= S W I T C H O F F
XMTR FACILITY
CODE SWITCHES
BOTH
FUNCTION
AS LEFT
BUTTON
LEFT
BUTTON
RIGHT
BUTTON
TOP
BUTTON
TOP
BUTTON
LEFT
BUTTON
RIGHT
BUTTON
BOTTOM-RIGHT
BUTTON
BOTTOM-LEFT
BUTTON
LEFT
BUTTON
LEFT
BUTTON
RIGHT
BUTTON
OPERATE
AS TOP
BUTTON
THE FACTORY SETTING ALLOWS ALL
TRANSMITTER BUTTONS TO OPERATE
SET XMTR BUTTON DISABLE SWITCH(ES) ON TO
PREVENT SELECTED TRANSMITTER BUTTONS
FROM OPERATING
SWITCH 4 - TOP
SWITCH 5 - BOTTOM RIGHT
SWITCH 6 - BOTTOM LEFT
SWITCH 7 - RIGHT OR TOP RIGHT
SWITCH 8 - LEFT OR TOP LEFT
INSTR,INST,WOR
Linear P/N: 212902 C
Material: 20 Lb. Mead Bond
Size: 8.500" x 11.000"
Ink: Black
Side 2 of 2
Scale: 1-1
7. SET OUTPUT FACILITY CODE
8. CONNECT TERMINALS 9. CONNECT ANTENNA
10. PROGRAM AND TEST SYSTEM LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date
is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s
normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling
dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation
for consequential damages arising out of or in connection with use or performance of this product or other indirect damages
with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties,
including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as
labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there
are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such,
they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or
near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these
facts should be communicated to the ultimate users.
Copyright © 2002 Linear Corporation 212902 C
OUTPUT FACILITY CODE 0
WILL PASS THROUGH THE
TRANSMITTER FACILITY CODE
SWITCH SETTINGS FOR OUTPUT FACILITY CODES 0-255
SWT 0
SWT 1
SWT 2
SWT 3
SWT 4
SWT 5
SWT 6
SWT 7
SWT 8
SWT 9
SWT 10
SWT 11
SWT 12
SWT 13
SWT 14
SWT 15
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
SWT 0
SWT 1
SWT 2
SWT 3
SWT 4
SWT 5
SWT 6
SWT 7
SWT 8
SWT 9
SWT 10
SWT 11
SWT 12
SWT 13
SWT 14
SWT 15
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
SWT 0
SWT 1
SWT 2
SWT 3
SWT 4
SWT 5
SWT 6
SWT 7
SWT 8
SWT 9
SWT 10
SWT 11
SWT 12
SWT 13
SWT 14
SWT 15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
0
SWT 0
SWT 1
SWT 2
SWT 3
SWT 4
SWT 5
SWT 6
SWT 7
SWT 8
SWT 9
SWT 10
SWT 11
SWT 12
SWT 13
SWT 14
SWT 15
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
64
= SWITCH OFF = SWITCH ON
OMNI-DIRECTIONAL
EXA-1000 ANTENNA
MOUNTED ON POLE
LOCAL WHIP
ANTENNA
(SUPPLIED)
CONNECTED
DIRECTLY TO
RECEIVER
DIRECTIONAL
EXA-2000 ANTENNA
MOUNTED ON POST
CHOOSE AN ANTENNA TO FIT THE INSTALLATION REQUIREMENTS
FOLLOW EXA ANTENNA
INSTRUCTIONS WHEN
CONSTRUCTING ANTENNA
SCREW CONNECTOR
ONTO RECEIVER
INDICATOR
VIEWING
WINDOW
ROUTE WIRE THROUGH
STRAIN RELIEF BEFORE
WIRING TO TERMINALS
(TIGHTEN LATER)
POWER AND
DATA TERMINALS
PWR (RED)
GND (BLK)
DAT1 (WHT)
DATO (GRN)
HOLD (BLU)
N/C
POWER
DATA
HOLD (OPTIONAL)
TO ACCESS
CONTROL
SYSTEM
WITH POWER APPLIED
TO THE RECEIVER,
PRESS AND RELEASE
THE PROGRAM BUTTON
TEST TRANSMITTERS FROM VARIOUS
LOCATIONS TO DETERMINE RADIO
RANGE
ADJUST THE RECEIVER'S
INTERNAL RADIO RANGE KNOB
TO LIMIT RADIO RECEPTION IF
REQUIRED
RECEPTION PATTERN WILL VARY
DEPENDING ON ANTENNA USED
AND SURROUNDING STRUCTURES
RADIO INDICATOR WILL
FLICKER AS SIGNAL IS
RECEIVED
STATUS INDICATOR LIGHTS
GREEN WHEN SENDING
WIEGAND DATA AND DURING
RECEIVER LOCKOUT
OPERATION, LIGHTS RED
WHEN HOLD INPUT IS
ACTIVE
  • Page 1 1
  • Page 2 2

Nortek Contol WOR User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI