INSTALLATION AND OPERATION MANUAL
CNGE5MS
ENVIRONMENTALLY HARDENED MANAGED ETHERNET SWITCH
WITH (3) 10/100/1000BASE-TX & (2) 10/100/1000BASE-TX/FX
COMBO PORTS
v1.4 February 21, 2013
The ComNet
CNGE5MS is a hardened, industrial five port all gigabit managed
Ethernet switch. It has three 10/100/1000Base-TX and two Gigabit combo ports
that utilize ComNet Small Form Factor (SFP) pluggable modules for the selection of
fiber and connector type and distance. The IEEE 802.3 compliant unit is a redundant
switch offering multiple Ethernet redundancy protocols, C-Ring, ComRing, C-RSTP
and MSTP/RSTP/STP. This redundancy feature protects your applications from network
interruptions or temporary malfunctions by redirecting transmission within the
network. The CNGE5MS offers centralized and convenient management through a
windows-based utility called eConsole. Redundant DC power inputs provide non-stop
operation in case of power supply disruption. The backup power input will take over
immediately when the primary DC power input fails. The unit provides relay outputs
that can be set up to indicate events and notify in case of potential problems.
INS_CNGE5MS_REV–
02/19/13 PAGE 2
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Contents
Regulatory Compliance Statement 3
Warranty 3
Disclaimer 3
Safety Indications 3
Overview 4
Introduction 4
Software Features 5
Hardware Features 6
Installing Switch on DIN-Rail 7
Wall Mounting Installation 9
Hardware Overview 10
Front Panel 10
Front Panel LEDs 12
Bottom Panel 13
Cables 14
Ethernet Cables 14
10/100/1000BASE-T(X) Pin Assignments 14
SFP 16
Console Cable 17
WEB Management 19
Configuration by Web Browser 19
About Web-based Management 19
Command Line Interface Management 76
About CLI Management 76
Command Level 80
Commands Set List—System Commands Set 81
Commands Set List—Port Commands Set 83
Commands Set ListTrunk command set 85
Commands Set List—VLAN command set 86
Commands Set List—Spanning Tree command set 87
Commands Set List—QoS command set 88
INS_CNGE5MS_REV–
02/19/13 PAGE 3
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Commands Set ListIGMP command set 89
Commands Set List—MAC/Filter Table command set 89
Commands Set List—SNMP command set 90
Commands Set List—Port Mirroring command set 91
Commands Set List802.1x command set 91
Commands Set ListTFTP command set 92
Commands Set List—SYSLOG, SMTP, EVENT command set 92
Commands Set List—SNTP command set 94
Commands Set List— Ring command set 95
Technical Specifications 96
INS_CNGE5MS_REV–
02/19/13 PAGE 4
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Regulatory Compliance Statement
Product(s) associated with this publication complies/comply with all applicable regulations. Please
refer to the Technical Specifications section for more details.
Warranty
ComNet warrants that all ComNet products are free from defects in material and workmanship
for a specified warranty period from the invoice date for the life of the installation. ComNet will
repair or replace products found by ComNet to be defective within this warranty period, with
shipment expenses apportioned by ComNet and the distributor. This warranty does not cover
product modifications or repairs done by persons other than ComNet-approved personnel, and
this warranty does not apply to ComNet products that are misused, abused, improperly installed,
or damaged by accidents.
Please refer to the Technical Specifications section for the actual warranty period(s) of the
product(s) associated with this publication.
Disclaimer
Information in this publication is intended to be accurate. ComNet shall not be responsible for its
use or infringements on third-parties as a result of its use. There may occasionally be unintentional
errors on this publication. ComNet reserves the right to revise the contents of this publication
without notice.
Safety Indications
» The equipment can only be accessed by trained ComNet service personnel.
» This equipment should be installed in secured location.
INS_CNGE5MS_REV–
02/19/13 PAGE 5
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Overview
Introduction
The CNGE5MS is a powerful, managed, hardened Ethernet switch that contains many features.
The switch will work under a wide variety of temperature, dirty and humid conditions. It can be
managed through WEB, TELNET, Consol or other third-party SNMP software. The CNGE5MS also
can be managed by a utility called eConsole.
eConsole is network management software that is very effective. With easy to use and intuitive
interface, you can easily configure multiple switches at the same time, and monitor the status of
those switches.
INS_CNGE5MS_REV–
02/19/13 PAGE 6
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Software Features
» Fast Redundant Ethernet Ring : C-Ring Technology (Recovery time < 20ms over 250 units
connection)
» Supports Ring Coupling, Dual Homing over C-Ring
» Supports SNMPv1/v2c/v3 & RMON & Port base/802.1Q VLAN Network Management
» Event notification by Email, SNMP trap and Relay Output
» Web-based ,Telnet, Console, CLI configuration
» Enable/disable ports, MAC based port security
» Port based network access control (802.1x)
» VLAN (802.1q ) to segregate and secure network traffic
» Radius centralized password management
» SNMPv3 encrypted authentication and access security
» RSTP (802.1w)
» Quality of Service (802.1p) for real-time traffic
» VLAN (802.1q) with double tagging and GVRP supported
» IGMP v2/v3 (support IGMP Snooping) for multicast filtering
» Port configuration, status, statistics, mirroring, security
» Remote Monitoring (RMON)
INS_CNGE5MS_REV–
02/19/13 PAGE 7
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Hardware Features
» 3 × Redundant DC power inputs
» Operating Temperature: -40 – 75ºC
» Storage Temperature: -40 – 85ºC
» Operating Humidity: 5% – 95%, non-condensing
» Casing: IP-30
» 3 × 10/100/1000Base-T(X) Gigabit Ethernet port
» 2 × 100/1000Base-X SFP & 10/100/1000Base-TX Combo ports
» Console Port
» Dimensions (W × D × H): 54.1 × 106.1 × 145.4mm
(2.13 × 4.18 × 5.72in)
INS_CNGE5MS_REV–
02/19/13 PAGE 8
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Installing Switch on DIN-Rail
The rear panel components of CNGE5MS shown below:
1. Screw holes for wall mount kit.
2. Din-Rail kit
1
1
2
INS_CNGE5MS_REV–
02/19/13 PAGE 9
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Each switch has a DIN-Rail kit on the rear panel. The DIN-Rail kit affixes the switch to the DIN-Rail.
It is easy to install the switch on the Din-Rail:
Mount Series on DIN-Rail
Step 1: Tilt the switch and mount the metal spring to DIN-Rail.
Step 2: Push the switch toward the DIN-Rail until you hear the spring snap into place
.
INS_CNGE5MS_REV–
02/19/13 PAGE 10
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Wall Mounting Installation
Each switch has another installation method for users to install the switch. A wall mount kit can be
found in the package. The following steps show how to mount the switch on the wall:
Mounting the CNGE5MS on a Wall
Step 1: Remove DIN-Rail kit if it is attached to the switch.
Step 2: Use the 6 included screws to attach the wall mount panel as shown in the diagram below.
In order to prevent switches from being damaged, use only the screws included with the mounting
kit for the CNGE5MS switch.
INS_CNGE5MS_REV–
02/19/13 PAGE 11
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Hardware Overview
Front Panel
The following table describes the LEDs and ports that are on the front of the CNGE5MS.
Port Description
10/100/1000Base-T(X)
RJ-45 fast Ethernet
ports
3 × 10/100/1000Base-T(X) RJ-45 fast Ethernet ports support
auto-negotiation.
Default Settings:
Speed: auto
Duplex: auto
Flow control: disable
Combination Port 2 × 100/1000Base-X SFP and 2x10/100/1000Base-T(X) ports
Console Use RS-232 with RJ-45 connecter to manage switch.
INS_CNGE5MS_REV–
02/19/13 PAGE 12
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
1
8
9
10
2
3
4
5
6
7
CNGE5MS Front Panel .
1. Model name
2. LED for PWR1. When the PWR1 UP, the green LED will be light on
3. LED for PWR2. When the PWR2 UP, the green LED will be light on.
4. LED for PWR3. When the PWR3 UP, the green LED will be light on.
5. LED for R.M (Ring Master). When the LED light is on, it means that the switch is the ring
master of Ring.
6. LED for Ring. When the LED light on, it means the C-Ring is activated.
7. LED for Fault. When the light on, it means Power failure or Port down/fail.
8. 10/100/1000 Base-T(X) Ethernet ports (RJ-45)
9. 100/1000Base-X SFP port (combo port)
10. 10/100/1000 Base-T(X) Ethernet port (combo port)
INS_CNGE5MS_REV–
02/19/13 PAGE 13
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Front Panel LEDs
LED indicators
LED Color Status Description
PWR1 Green On DC power module 1 activated
PWR2 Green On DC power module 2 activated
PWR3 Green On DC Power module 3 activated
R.M Green On Ring Master.
Ring Green On Ring enabled.
Slowly blinking Ring has only One link. (lack of one link to
build the ring.)
Fault Amber On Fault relay. Power failure or Port down/
fail.
10/100/1000Base-T(X) Ethernet ports
LNK /ACT Green On Port link up.
Blinking Data transmitted.
100Mbps
indicator
Amber On Port speed is 100Mbps
SFP
LNK /ACT Green On Port link up.
Blinking Data transmitted.
INS_CNGE5MS_REV–
02/19/13 PAGE 14
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Bottom Panel
The bottom panel of CNGE5MS is displayed as below:
CNGE5MS Rear Panel
1. Terminal block includes: PWR1, PWR2 (12-48V DC) and Relay output (1A@24VDC).
2. Power jack for PWR3 (12-45VDC).
3. Console port (RJ-45).
1
3
2
INS_CNGE5MS_REV–
02/19/13 PAGE 15
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Cables
Ethernet Cables
The CNGE5MS switches have standard Ethernet ports. According to the link type, the switches
use CAT 3, 4, 5, & 5e UTP cables to connect to any other network device (PCs, servers, switches,
routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 10 UTP 100m (328ft) RJ-45
100BASE-TX Cat. 5 100Ω UTP UTP 100m (328ft) RJ-45
1000BASE-TX Cat. 5/Cat. 5e 100Ω UTP UTP 100m (328ft) RJ-45
10/100/1000BASE-T(X) Pin Assignments
With 100BASE-T(X)/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6
are used for receiving data.
10/100 Base-T RJ-45 Pin Assignments
Pin Number Assignment
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
INS_CNGE5MS_REV–
02/19/13 PAGE 16
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
1000 Base-T RJ-45 Pin Assignments
Pin Number Assignment
1 BI_DA+
2 BI_DA-
3 BI_DB+
4 BI_DC+
5 BI_DC-
6 BI_DB-
7 BI_DD+
8 BI_DD-
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
The CNGE5MS switches support auto MDI/MDI-X operation. You can use a straight-through cable
to connect PC to switch. The following table below shows the 10/100BASE-T(X) MDI and MDI-X
port pin-outs:
10/100 Base-T MDI/MDI-X pin assignments
Pin Number MDI port MDI-X port
1 TD+ (transmit) RD+ (receive)
2 TD- (transmit) RD- (receive)
3 RD+ (receive) TD+ (transmit)
4 Not used Not used
5 Not used Not used
6 RD- (receive) TD- (transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
INS_CNGE5MS_REV–
02/19/13 PAGE 17
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
1000 Base-T MDI/MDI-X pin assignments
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
SFP
The Switch has fiber optic ports that utilize SFP connectors. ComNet offers a wide selection of SFP
modules that offer different fiber type, connector type and distances. Please remember that the
TX port of Switch A should be connected to the RX port of Switch B.
Switch A Fiber Cord Switch B
INS_CNGE5MS_REV–
02/19/13 PAGE 18
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
Console Cable
Each CNGE5MS switch can be managed by its console port. You can connect them to PC via an
RJ-45 cable with DB-9 female connector.
DB-9 to RJ-45 Cable
PC pin out
(male) assignment
RS-232 with
DB9 female connector
DB9 to RJ 45
Pin #2 RD Pin #2 TD Pin #2
Pin #3 TD Pin #3 RD Pin #3
Pin #5 GD Pin #5 GD Pin #5
INS_CNGE5MS_REV–
02/19/13 PAGE 19
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
5
9
1
6
DB-9 Male
1
6
5
9
DB-9 Female
Pin Male Connector Female Connector
1 Received Line Signal Detect (Received by DTE
Device)
Received Line Signal Detect (Transmitted
from DCE Device)
2 Received Data (Received by DTE Device) Transmitted Data (Transmitted from DCE
Device)
3 Transmitted Data (Transmitted from DTE Device) Received Data (Received by DCE Device)
4 DTE Ready (Transmitted from DTE Device) DTE Ready (Received by DCE Device)
5 Signal Ground Signal Ground
6 DCE Ready (Received by DTE Device) DCE Ready (Transmitted from DCE Device)
7 Request to Send (Transmitted from DTE Device) Clear to Send (Received by DCE Device)
8 Clear to Send (Received by DTE Device) Request to Send (Transmitted from DCE
Device)
9 Ring Indicator (Received by DTE Device) Ring Indicator (Transmitted from DCE Device)
INS_CNGE5MS_REV–
02/19/13 PAGE 20
INSTALLATION AND OPERATION MANUAL CNGE5MS
Tech SupporT: 1.888.678.9427
WEB Management
Attention: While installing and upgrading firmware, please remove physical loop connection first.
DO NOT power off equipment while the firmware is upgrading!
Configuration by Web Browser
This section provides instruction on configuration through the Web browser.
About Web-based Management
An embedded HTML web site resides in the flash memory on the CPU board. It contains
advanced management features and allows you to manage the switch from anywhere on the
network through a standard web browser such as Microsoft Internet Explorer.
The Web-Based Management function supports Internet Explorer 5.0 or later. It utilizes Java
Applets with an aim to reduce network bandwidth consumption, enhance access speed and
present an easy viewing screen.
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. You need to
explicitly modify the browser setting in order to enable Java Applets to use network ports.
Preparing for Web Management
The default value is as below:
IP Address: 192.168.10.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.10.254
User Name: admin
Password: admin
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Comnet CNGE5MS User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI