Schlage D Series Lever User manual

Type
User manual

This manual is also suitable for

Schlage D Series Lever: A Versatile and Secure Locking Solution for Various Applications

The Schlage D Series Lever is a high-quality lock assembly designed to provide reliable security and functionality for a wide range of doors. With its ANSI A156.13, 1994 certification, you can trust the D Series Lever to meet industry standards for performance and durability.

Key Features:

• Multiple Functions: Choose from a variety of functions to suit your specific needs, including passage, privacy, keyed entry, and more.

• Fail-Safe and Fail-Secure Options: Select models that offer fail-safe or fail-secure operation for added security and peace of mind.

Schlage D Series Lever: A Versatile and Secure Locking Solution for Various Applications

The Schlage D Series Lever is a high-quality lock assembly designed to provide reliable security and functionality for a wide range of doors. With its ANSI A156.13, 1994 certification, you can trust the D Series Lever to meet industry standards for performance and durability.

Key Features:

• Multiple Functions: Choose from a variety of functions to suit your specific needs, including passage, privacy, keyed entry, and more.

• Fail-Safe and Fail-Secure Options: Select models that offer fail-safe or fail-secure operation for added security and peace of mind.

Service Manual D
1
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D10S F75 Passage Latch
Both levers always unlocked. Page 64-250
D12D F89 Exit Lock
Outside lever always fixed. Inside lever always
unlocked.
Page 64-271
D12DEL Electrically Locked (fail safe)
Outside lever continuously locked electrically. Unlocked
by swtich or power failure. Auxiliary latch deadlocks
latchbolt when door is closed. Inside lever always free
for immediate exit.
Page 64-272
D12DEU Electrically Unlocked (fail secure)
Outside lever continuously locked until unlocked by
electric current. Auxiliary latch deadlocks latchbolt when
door is closed. Inside lever always free for immediate
exit.
Page 64-273
D170 Single Dummy Trim
Dummy trim for one side of door. Used for door pull or
as matching inactive trim.
Page
D25D Exit Lock with Blank Plate Outside
Blank plate outside. Inside lever always unlocked. Page 64-253
D25xD70 x XC11-577 Blank Plate Outside with Keyed Lever
Same as D25 with keyed lever inside. Key locks or
unlocks inside lever. Specify per XC11-577.
Page
D Service Manual
2
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D25xD80 x XC03-543 Blank Plate Outside with Keyed Fixed Lever
Same as D25 with fixed keyed lever inside. Key in lever
retracs latch. Specify per XC03-543.
Page
D30D x XC11-801 Patio Lock
Push-button locking. Turning inside lever or closing door
releases button. Specify per XC11-801.
Page
D40S F76 Bath/Bedroom Privacy Lock
Push-button locking. Can be opened from outside with
small screwdriver. Turning inside lever or closing door
releases button.
Page 64-254
D44S Hospital Privacy Lock
Push-button locking. Unlocked from outside by turning
emergency turn-button. Turning inside lever or closing
door releases button.
Page 64-254
D50BD F82 Entrance/Office Lock with SFIC
Push-button locking. Push-button locks outside lever
until unlocked with key or by turning inside lever.
Page
D50PD F82 Entrance/Office Lock
Push-button locking. Push-button locks outside lever
until unlocked with key or by turning inside lever.
Page 64-255
D53BD F82 Entrance Lock with SFIC
Turn/push-button locking; pushing and turning button
locks outside lever, requiring use of key until button is
manually unlocked. Push-button locking; pushing button
locks outside lever until unlocked by key or by turning
inside lever.
Page
Service Manual D
3
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D53PD F82 Entrance Lock
Turn/push-button locking; pushing and turning button
locks outside lever, requiring use of key until button is
manually unlocked. Push-button locking; pushing button
locks outside lever until unlocked by key or by turning
inside lever.
Page
D60BD F88 Vestibule/Classroom Security Lock with SFIC
Latch retacted by key from outside when outside lever is
locked by key in inside lever. Inside lever is always
unlocked.
Page
D60PD F88 Vestibule/Classroom Security Lock
Latch retacted by key from outside when outside lever is
locked by key in inside lever. Inside lever is always
unlocked.
Page 64-256
D60 x XC03-928 D60 with Closed Outside Lever
Outside lever is locked by key in inside lever. Inside
lever is always unlocked. Specify per XC03-928.
Page
D66PD F91 Store Lock*
Key in either lever locks or unlocks both levers. Page 64-257
D66BD x XC11-942 Store Lock with SFIC*
Key in either lever locks or unlocks both levers. Specify
XCll-942.
Page
D70BD F84 Classroom Lock SFIC
Outside lever locked and unlocked by key. Inside lever
always unlocked.
Page
D Service Manual
4
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D70PD F84 Classroom Lock
Outside lever locked and unlocked by key. Inside lever
always unlocked.
Page
D70xD80 x XCo7-960 Classroom Lock with Keyed Inside Lever
Outside lever locked and unlocked by key. Inside lever
fixed. Key in inside lever retracts latch.
Specify Xc07-960.
Page
D72BD x XC11-767 Communicating Lock with SFIC
Latchbolt retracted by lever from either side. Key in
either lever locks and unlocks own lever.
Specify XCll-767
Page
D72PD x XC11-767 Communicating Lock
Latchbolt retracted by lever from either side. Key in
either lever locks and unlocks own lever.
Specify XCll-767
Page
D72BD x XC11-943 Communicating Lock with SFIC and
Vandlgard
Latchbolt retracted by lever from either side. Key in
either lever locks and unlocks own lever. Vandlgard is
designed to disengage outside spindle from latch when
in locked condition. Specify XCll-943
Page
D72PD x XC11-943 Communicating Lock with Vandlgard
Latchbolt retracted by lever from either side. Key in
either lever locks and unlocks own lever. Vandlgard is
designed to disengage outside spindle from latch when
in locked condition. Specify XCll-943
Page
D73BD F90 Corridor Lock with SFIC
Locked or unlocked by key from outside. Push-button
locking from inside. Turning inside lever or closing door
releases button.
Page
D73PD F90 Corridor Lock
Locked or unlocked by key from outside. Push-button
locking from inside. Turning inside lever or closing door
releases button.
Page
Service Manual D
5
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D80BD F86 Storeroom Lock with SFIC
Outside lever fixed. Entrance by key only. Inside lever
always unlocked.
Page
D80PD F86 Storeroom Lock
Outside lever fixed. Entrance by key only. Inside lever
always unlocked.
Page
D80BDEL Electrically Locked (Fail Safe) with SFIC
Outside lever continuouslty locked electrically. Unlocked
by key outside, switch, or power failure. Auxiliary latch
deadlocks latchbolt when door is closed. Isdie lever
always free for immediate egress.
Page
D80PDEL Electrically Locked (Fail Safe)
Outside lever continuouslty locked electrically. Unlocked
by key outside, switch, or power failure. Auxiliary latch
deadlocks latchbolt when door is closed. Isdie lever
always free for immediate egress.
Page 64-266
D80BDEU Electrically Unlocked (Fail Secure) with SFIC
Outside lever continuosly locked until unlocked by key
or electric current. Auxiliary latch deadlocks latchbolt
when door is closed. Inside lever always free for
immediate exit.
Page
D80PDEU Electrically Unlocked (Fail Secure)
Outside lever continuosly locked until unlocked by key
or electric current. Auxiliary latch deadlocks latchbolt
when door is closed. Inside lever always free for
immediate exit.
Page 64-267
D82BD x XC11-906 Institution Lock with SFIC*
Both levers fixed. Entrance by key in either lever.
Specify XCll-906.
Page
* CAUTION: Double cylinder locks on residences—or on any door in any structure which are used for egress—are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
D Service Manual
6
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D82PD F87 Institution Lock*
Both levers fixed. Entrance by key in either lever. Page 64-264
D85PD F93 Hotel/Motel Lock
Outside lever fixed. Entrance by key only. Push-button in
inside lever activates visual occupancy indicator
allowing only emergency masterkey to operate. Turning
inside lever or closing door releases visual occupancy
indicator. Rotation of inside spanner-button provides
lockout feature by keeping indicator thrown
Page 64-265
D91BD F82 Entrance/Office Lock with andlgard and SFIC
Push-button locking. Push-button disengages outside
lever until unlocked with key or by turning inside lever.
Vandlgard is designed to disengage outside spindle
from latch when in locked condition.
Page 64-655
D91PD F82 Entrance/Office Lock with andlgard
Push-button locking. Push-button disengages outside
lever until unlocked with key or by turning inside lever.
Vandlgard is designed to disengage outside spindle
from latch when in locked condition.
Page 64-555
D92BD F82 Entrance Lock with Vandlgard and SFIC
Turn/push-button locking; pushing and turning button
disengages outside lever, requiring use of key until
button is manually unlocked. Push-button locking;
pushing button disengages outside lever until unlocked
by key or by turning inside lever. Vandlgard is designed
to disengage outside spindle from latch when in locked
condition.
Page 64-662
D92PD F82 Entrance Lock with Vandlgard
Turn/push-button locking; pusihing and turning button
disengages outside lever, requiring use of key until
button is manually unlocked. Push-button locking;
pushing button disengages outside lever until unlocked
by key or by turning inside lever. Vandlgard is designed
to disengage outside spindle from latch when in locked
condition.
Page 64-562
D93BD F88 Classroom Security Lock with SFIC and
Vandlgard**
Latch retracted by key from outside when outside
lever is disengaged by key in inside lever. Inside
lever is always unlocked. Vandlgard is designed
to disengage outside spindle from latch when in
locked condition.
Page 64-563
Service Manual D
7
D93PD F88 Classroom Security Lock with Vandlgard**
Latch retracted by key from outside when outside
lever is disengaged by key in inside lever. Inside
lever is always unlocked. Vandlgard is designed
to disengage outside spindle from latch when in
locked condition.
Page 64-565
* CAUTION: Double cylinder locks on residences—or on any door in any structure which are used for egress—are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
D Service Manual
8
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994, Series 1000 Exploded View
Page
Assembled
Chassis Part
Number
D94BD F84 Classroom Lock with Vandlgard and SFIC
Outside lever disengaged and unlocked by key.
Inside lever always unlocked. Vandlgard is
designed to disengage outside spindle from latch
when in locked condition.
Page 64-658
D94BD F84 Classroom Lock with Vandlgard
Outside lever disengaged and unlocked by key.
Inside lever always unlocked. Vandlgard is
designed to disengage outside spindle from latch
when in locked condition.
Page 64-558
D96BD F86 Storeroom Lock with Vandlgard and SFIC
Outside lever always locked and disengaged.
Entrance by key only. Inside lever always
unlocked. Vandlgard is designed to disengage
outside spindle from latch when in locked
condition.
Page 64-560
D96PD F86 Storeroom Lock with Vandlgard
Outside lever always locked and disengaged.
Entrance by key only. Inside lever always
unlocked. Vandlgard is designed to disengage
outside spindle from latch when in locked
condition.
Page 64-660
* CAUTION: Double cylinder locks on residences—or on any door in any structure which are used for egress—are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Schlage D Series Lever User manual

Type
User manual
This manual is also suitable for

Schlage D Series Lever: A Versatile and Secure Locking Solution for Various Applications

The Schlage D Series Lever is a high-quality lock assembly designed to provide reliable security and functionality for a wide range of doors. With its ANSI A156.13, 1994 certification, you can trust the D Series Lever to meet industry standards for performance and durability.

Key Features:

• Multiple Functions: Choose from a variety of functions to suit your specific needs, including passage, privacy, keyed entry, and more.

• Fail-Safe and Fail-Secure Options: Select models that offer fail-safe or fail-secure operation for added security and peace of mind.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI