Haier AB25S2SC1FA, 1U71S2SG1FA, 3U52S2SG1FA, 3U68S2SG1FA, 4U70S2SH1FA, 4U85S2SH1FA, AB35S2SC1FA, AD25S2SS1FA, AD35S2SS1FA, AD50S2SM1FA, AD71S2SM1FA User manual

  • Hello! I am an AI chatbot trained to assist you with the Haier AB25S2SC1FA User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SYJS-04-2017 REV.A Edition: 2017-04
service manual
R32
CONTENTS
Part 1 General Information .......................................................................................................................................1
1. Indoor/outdoor unit models................................................................................................................................2
2. Feature .................................................................................................................................................................3
Part 2 Indoor Units ....................................................................................................................................................5
1. Specification ........................................................................................................................................................6
2. Dimension ..........................................................................................................................................................12
3. Wiring diagram ..................................................................................................................................................14
4. Air velocity and temperature distribution .......................................................................................................17
5. Installation .........................................................................................................................................................21
Part 3 Outdoor Units ...............................................................................................................................................42
1. Specification ......................................................................................................................................................43
2. Dimension ..........................................................................................................................................................52
3. Wiring diagram ..................................................................................................................................................55
4. Wiring connection .............................................................................................................................................58
5. Refrigerant diagram ..........................................................................................................................................60
6. Limitation values on pipe installation .............................................................................................................63
7. Combination and the data ................................................................................................................................65
8. Sound pressure level ........................................................................................................................................79
9. Outdoor performance curves ...........................................................................................................................83
10. Installation........................................................................................................................................................88
Part 4 Electric Control and Debugging ................................................................................................................112
1. Indoor unit PCB photo, dip switch setting and function .............................................................................113
2. Outdoor unit PCB photo, dip switch setting and function ..........................................................................120
3. Diagnostic code ............................................................................................................................................... 137
4. Trouble shooting .............................................................................................................................................141
5. Controller function ..........................................................................................................................................159
Appendix Sensor characteristic ........................................................................................................................175
1
Part 1 General Information
1. Indoor/outdoor unit models................................................................................................................................2
2. Feature .................................................................................................................................................................3
2
1.
Indoor/outdoor unit models
Compact cassette
AB25S2SC1FA
AB35S2SC1FA
Low ESP duct
AD25S2SS1FA
AD35S2SS1FA
Medium ESP duct
AD50S2SM1FA
AD71S2SM1FA
Indoor unit models
1U71S2SG1FA
3U52S2SG1FA
3U68S2SG1FA
4U70S2SH1FA
4U85S2SH1FA
Outdoor unit models
3
2. Feature
New valve cover design
Less screws to open valve cover
Easy to vacuum
Appearance
Installation
Compared with the current 1:3 valve cover , we design the new valve cover , which is more slim in the appearance;
In the installation course , installer need to take down the valve cover , then to do wiring and piping , next is the
comparison in taking down the valve cover;
General stop valve vacuum every indoor unit from one valve only , save time. ( for 1:4 outdoor unit)
Current R410a 1:3
Cover length
72.5mm
New R32 1:3
Cover length
60mm
3 screws
for right side
7 Screws to take down ; (Current R410a 3U cover )
4 screws
for left side
3 Screws to take down ; (R32 3U cover )
2 screws
for right side
1 screws
for left side
General stop valve
4
Easy to carry
Easy start up & maintenance
Left & right two handles are easy for two people carry the units;
* “88” screen show compressor frequency or failure code,
* On site testing software check all running data ;
This two tools make easy start up & maintenance ;
Cooling only /heating only
Central control/BMS control
Solution Supplier
Cooling only /heating only function for special requirement;
Central control / BMS control function meet the various needs for designer;
Note: BMS control is the function in the future
Central control
BMS control
12345678 12345678
ON
ON
SW5
SW5-1 ON cooling only
SW5-2 ON heating only
SW5
5
Part 2 Indoor Units
1. Specification ..........................................................................................................................................................6
2. Dimension ...........................................................................................................................................................12
3. Wiring diagram ....................................................................................................................................................14
4. Air velocity and temperature distribution .............................................................................................................17
5. Installation ...........................................................................................................................................................21
6
Item Model AB25S2SC1FA
Function —— Cooling Heating
capacity W 2600 3200
sensible heat ratio W 0.71 /
Dehumidifying capacity 10-³xm³/h 1.0
indoor unit
power supply 1PH, 220-240V~, 50/60Hz
Fan
Type × Number —— centrifugal*1
Speed(H-M-L) r/min 690/620/560/500
Fan motor output/input power W 10/15
Air-ows (H/M/L) m³/h 620/520/450/350
Heat exchanger
Type / Diameter mm inner grooved pipe/
7.0
Row —— 1
Total area 0.272
Temp.scope
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 570*570*260
Package mmxmmxmm 718*680*380
Drainage pipe (material,I.D/O.D) mm PVC 26/32
control type(Remote/Wired) Remote YR-HBS01(O) or Wired YR-E17(O)
Fresh air hole dimension mm 95
Electricity Heater kW none
Noise level(H-
M-L)
Sound power level dB(A) 52
Sound pressure level dB(A) 36/33/30/27
weight(Net/Shipping) kg/kg 17/20
panel
panel model(color) PB-700IB(White)
Dimension
External(L*W*H) mmxmmxmm 700*700*60
Package(L*W*H) mmxmmxmm 740*750*115
Weight(Net/Shipping) kg/kg 2.8/4.8
Piping
Refrigerant Type R32
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ9.52(3/8)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter.
1. Specification
7
Item Model AB35S2SC1FA
Function —— Cooling Heating
capacity W 3500 4000
sensible heat ratio W 0.71 /
Dehumidifying capacity 10-³xm³/h 1.5
indoor unit
power supply 1PH, 220-240V~, 50/60Hz
Fan
Type × Number —— centrifugal*1
Speed(H-M-L) r/min 690/620/560/500
Fan motor output/input power W 10/15
Air-ows (H/M/L) m³/h 620/520/450/350
Heat exchanger
Type / Diameter mm inner grooved pipe/
7.0
Row —— 2
Total area 0.544
Temp.scope
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 570*570*260
Package mmxmmxmm 718*680*380
Drainage pipe (material,I.D/O.D) mm PVC 26/32
control type(Remote/Wired) Remote YR-HBS01(O) or Wired YR-E17(O)
Fresh air hole dimension mm 95
Electricity Heater kW none
Noise level(H-
M-L)
Sound power level dB(A) 52
Sound pressure level dB(A) 36/33/30/27
weight(Net/Shipping) kg/kg 18.5/22
panel
panel model(color) PB-700IB(White)
Dimension
External(L*W*H) mmxmmxmm 700*700*60
Package(L*W*H) mmxmmxmm 740*750*115
Weight(Net/Shipping) kg/kg 2.8/4.8
Piping
Refrigerant Type R32
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ9.52(3/8)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter.
8
Item Model AD25S2SS1FA
Function —— Cooling Heating
capacity W 2500 3000
sensible heat ratio W 0.71 /
Dehumidifying capacity 10-³xm³/h 1.0
indoor unit
power supply 1PH, 220-240V~, 50/60Hz
Fan
Type × Number —— centrifugal*2
Speed(H-M-L) r/min 850/750/650/600
Fan motor output/input power W 11/15
Air-ows (H/M/L) m³/h 530/460/390/330
External static pressure pa 0/10/20/30
Heat exchanger
Type / Diameter mm inner grooved pipe/
7.0
Row —— 2
Total area 0.11
Temp.scope
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 850x420x185
Package mmxmmxmm 1045x540x270
Drainage pipe (material,I.D/O.D) mm PVC 27/31
control type(Remote/Wired) Wired YR-E17(O) or Remote YR-HBS01(O)
Fresh air hole dimension mm none
Electricity Heater kW none
Noise level(H-
M-L)
Sound power level dB(A) 51
Sound pressure level dB(A) 33/30/26/23
weight(Net/Shipping) kg/kg 16/21
panel
optional
panel model(color) P1B-890IA/D
Dimension
External(L*W*H) mmxmmxmm
890/190/100
(outlet panel)/
890/290.5/32.4
(inlet panel)
Package(L*W*H) mmxmmxmm 938/335/220
Weight(Net/Shipping) kg/kg 4/5
Piping
Refrigerant Type R32
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ9.52(3/8)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter.
9
Item Model AD35S2SS1FA
Function —— Cooling Heating
capacity W 3500 4000
sensible heat ratio W 0.71 /
Dehumidifying capacity 10-³xm³/h 1.5
indoor unit
power supply 1PH, 220-240V~, 50/60Hz
Fan
Type × Number —— centrifugal*2
Speed(H-M-L) r/min 950/850/750/700
Fan motor output/input power W 16/21
Air-ows (H/M/L) m³/h 600/480/420/350
External static pressure pa 0/10/20/30
Heat exchanger
Type / Diameter mm inner grooved pipe/
7.0
Row —— 2
Total area 0.11
Temp.scope
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 850x420x185
Package mmxmmxmm 1045x540x270
Drainage pipe (material,I.D/O.D) mm PVC 27/31
control type(Remote/Wired) Wired YR-E17(O) or Remote YR-HBS01(O)
Fresh air hole dimension mm none
Electricity Heater kW none
Noise level(H-
M-L)
Sound power level dB(A) 53
Sound pressure level dB(A) 35/32/29/26
weight(Net/Shipping) kg/kg 16/21
panel
optional
panel model(color) P1B-890IA/D
Dimension
External(L*W*H) mmxmmxmm
890/190/100
(outlet panel)/
890/290.5/32.4
(inlet panel)
Package(L*W*H) mmxmmxmm 938/335/220
Weight(Net/Shipping) kg/kg 4/5
Piping
Refrigerant Type R32
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ9.52(3/8)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter.
10
Item Model AD50S2SM1FA
Function —— Cooling Heating
capacity W 5000 6000
sensible heat ratio W 0.73 /
Dehumidifying capacity 10-³xm³/h 1.8
indoor unit
power supply 1PH, 220-240V~, 50/60Hz
Fan
Type × Number —— centrifugal*2
Speed(H-M-L) r/min 900/820/770/720
Fan motor output/input power W 45/70
Air-ows (H/M/L) m³/h 1080/900/780/660
External static pressure Pa 150/130/120/110/100/90/70/50/37/25
Heat exchanger
Type / Diameter mm inner grooved pipe/
7.0
Row —— 2
Total area /
Temp.scope
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 957/655/250
Package mmxmmxmm 1170/860/340
Drainage pipe (material,I.D/O.D) mm PVC 25/29
control type(Remote/Wired) Wired YR-E17(O) or Remote YR-HBS01(O)
Fresh air hole dimension mm 145
Electricity Heater kW none
Noise level(H-
M-L)
Sound power level dB(A) 57
Sound pressure level dB(A) 37/34/32/29
weight(Net/Shipping) kg/kg 26/33
Piping
Refrigerant Type R32
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ12.7(1/2)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter.
11
Item Model AD71S2SM1FA
Function cooling heating
Capacity KW 7.1(2.0~8.2) 8.0(2.5~8.5)
Sensible heat ratio 0.74 /
Total power input KW 2.15(0.6~2.6) 2.16(0.6~2.6)
Max. power input W
3000 3000
EER or COP W/W 3.30 3.71
Dehumidifying capacity 10
-
³×m³/h 2.5
Power cable H05RN-F 4G 6.0mm2
Power source N, V, Hz
1PH, 220-240V~, 50/60Hz
Running /Max.Running current A / A 9.7(2.3-12)/16 9.8(2.3-12)/16
Start Current A 3
Indoor unit
Unit model (color) AD71S2SM1FA
Fan
Type × Number CENTRIFUGALX2
Speed(H-M-L) r/min 1130/950/820/780
Fan motor output/ input power W 85/111
Air-ow(H-M-L) m³/h 1440/1140/900/800
External static pressure Pa 25/37//50/70/90/100/110/120/130/150
Heat
exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 3
Total Area 7.668
Dimension
External(L×W×H) mm×mm×mm 957/655/250
Package(L×W×H) mm×mm×mm 1170/860/340
Drainage pipe (material , I.D./O.D.) mm PVC 25/29
Controller
(O-Optional,S-Standard)
Wired YR-E16(O)/YR-E17(S)
Fresh air hole dimension mm NONE
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 58
Sound pressure Noise level (H-M-L) dB(A) 42/38/35
Pipe
Liquid Pipe(mm) 9.52
Gas Pipe(mm) 15.88
Connecting Method ared
Weight (Net / Shipping) kg / kg 31.2/36.8
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity
meter. It is a sound pressure noise level.
12
AB25S2SC1FA AB35S2SC1FA
AD25S2SC1FA AD35S2SC1FA
420
370
892
850
185
640
90
760
152
2. Dimension
957
990
1050
595.5
655
720
250
148
57
57
57
103
797
Note: The cushion pasted in the bottom plate isn't included in the thickness data.
unit : mm
13
AD50S2SM1FA AD71S2SM1FA
14
3. Wiring diagram
AB25S2SC1FA AB35S2SC1FA
TO OUT DOOR
0150523323
BM1-1
BM1-7
BM1-8
TYPE DEFINE
OFFOFF
BM1-2 BM1-3
BTU
B:BLACK
R:RED
W:WHITE
Y/G:YELLOW/GREEN
TEMP.
SENSOR
ROOM
SENSOR
FLOAT
SWITCH
HEATER
PUMP
UP/DOWN
CN9
CN1
CN6
PANNEL
CN4
CN11
CN19
CN13
CN3
ON
CN7
CN21
T5A/250VAC
FUSE
BM3
2
1
3
B
W
R
Y/G
OFF OFF OFF
ON OFF OFF
OFF ON OFF
ON ON OFF
OFF OFF ON
ON OFF ON
OFF ON ON
ON ON ON
9000
12000
18000
24000
28000
36000
48000
60000
NOTE1.DASHED PART ARE OPTIONAL.
2. USER SHOULD NOT TO SET BM1 AND BM3
CH1
OFF OFF
BM1-4
BM1-5
BM1-6
OFF
OFF
CN16
G
CN8
G
TEMP.
PIPING
DC FAN
ROOMCARD
U-HOME
WIRED
CONTROLLER
B
A
C
BA
C
REMOTE
CENTRAL
87654321
ON
BM1
OFF
87654321
N
OFF
Room card
available
unavailable
ON
AB25S2SC1FA
AB35S2SC1FA
Default
15
AD25S2SC1FA AD35S2SC1FA
Y/G:YELLOW/GREEN
NOTE:
1.DASHED PARTS ARE OPTIONAL.
2.
USER SHOULD NOT SET SW01 AND
SW03 WITHOUT GUIDENCE.
3.WHEN ONE WIRED CONTROLLER CONTROL MULTIPLE INDOOR UNIT,
IT CAN CONNECT ANOTHER INDOOR UNIT BY CN22 OR CN22-1.
WHEN TWO WIRD CONTROLLERS CONTROL ONE INDOOR UNIT,
THE WIRED CONTROLLER NEED CONNECT WITH CN22 AND CN22-1.
TEMP.
SENSOR
ROOM
SENSOR
PIPING
TEMP.
ROOMCARD
R O T O M N A F C D
SW03
FUSE
WIRED
CONTROLLER
FLOAT
SWITCH
WIFI
MODULE
PUMP
TO OUT DOOR
2
1
3
Y/G
M
12345678
ON
INFRARED
REMOTE RECEIVER
M
B
A
C
B
A
C
OFF
0150523322
2
1
3
N L S
B A
C
SW01
12345678
ON
OFF
FRESH AIR MOTOR
(SW01-6 select OFF) /
EXTERNAL ALARM OUTPUT
(SW01-6 select ON)
( Contact rating_230VAC,3A)
M
CN21
Heater_L
CH4
Heater_N
CH2
CN5
CN4
CN34
CN16
CH1
SW01-1
SW01-2
SW01-3
OFF
SW01-4
SW01-5
SW01-6
SW01-7
SW01-8
MODEL
OFF
AD35S2SS1FA
OFF
OFF
OFF
ON
ON
OFF
CN13
CN6
CN41
CN22
CN22-1
4.SW03-5
->SW03-08 ARE USED FOR
ADDRESS SETTING ON THE
SITUATION OF ONE WIRED CONTROLLER CONTROL MORE THAN
ONE INDOOR UNIT.
5.REFER TO SERVICE MANUL TO GET MUCH MORE DETAILS
ABOUT THE STATIC PRESSURE LEVEL SELECTION.
CN1
AD25S2SS1FA
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW03-1 SW03-2 SW03-3 SW03-4 SW03-5 SW03-6 SW03-7 SW03-8
OFF OFF OFF OFF OFF OFF OFF OFF
FOR ALL
DUCT MODEL
16
AD50S2SM1FA AD71S2SM1FA
Y/G:YELLOW/GREEN
NOTE:
1.DASHED PARTS ARE OPTIONAL.
2.SW03-4 IS AT ON POSITION,DO NOT CHANGE
THE SETTINGS OF SWITCHS WITHOUT GUIDANCE.
3.WHEN ONE WIRED CONTROLLER CONTROL MULTIPLE INDOOR UNIT,
IT CAN CONNECT ANOTHER INDOOR UNIT BY CN22 OR CN22-1.
WHEN TWO WIRD CONTROLLERS CONTROL ONE INDOOR UNIT,
THE WIRED CONTROLLER NEED CONNECT WITH CN22 AND CN22-1.
TEMP.
SENSOR
ROOM
SENSOR
PIPING
TEMP.
ROOMCARD
R O T O M N A F C D
SW03
FUSE
WIRED
CONTROLLER
FLOAT
SWITCH
WIFI
MODULE
PUMP
TO OUT DOOR
2
1
3
Y/G
M
12345678
ON
REMOTE RECEIVER
M
B
A
C
B
A
C
OFF
0150523302
2
1
3
N L S
B A
C
SW01
12345678
ON
OFF
FRESH AIR MOTOR
(SW01-6 select OFF) /
EXTERNAL ALARM OUTPUT
(SW01-6 select ON)
( Contact rating_230VAC,3A)
M
CN21
Heater_L
CH4
Heater_N
CH2
CN5
CN4
CN34
CN16
CH1
SW01-1
SW01-2
SW01-3
ON
SW01-4
SW01-5
SW01-6
SW01-7
SW01-8
MODEL
OFF
AM24LP2VHA
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ADH071M3ERG
OFF
OFF
ON
CN13
CN6
CN41
CN22
CN22-1
4.SW03-5
->SW03-08 IS USED FOR
ADDRESS SETTING ON THE
SITUATION OF ONE WIRED CONTROLLER CONTROL MORE THAN
ONE INDOOR UNIT.
5.REFER TO SERVICE MANUL TO GET MUCH MORE DETAILS
ABOUT THE STATIC PRESSURE LEVEL SELECTION.
CN1
AD71S2SM1FA
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF OFF
ON
AD50S2SM1FA
SW03-1
SW03-2
SW03-3
FOR ALL DUCTED
MODEL
SW03-4 SW03-5 SW03-6
SW03-7
SW03-8
OFF OFF OFF OFF OFF OFF OFF ON
17
4. Air velocity and temperature distribution
a. Cooling / Air Velocity Distribution
Cooling
Blowy angle:40
Air Velocity Distribution
1.5m/s
1.5m/s
1.0m/s
1.0m/s
0.5m/s
2.7m
2m
2m2m
1m
1m
1m
4m
3m
3m
4m
0m
0m
0.5m/s
b. Cooling / Temperature Distribution
Cooling
Blowy angle:40
Temperature Distribution
27
52
22
22
27
25
2.7m
2m
1m
0m
4m
3m
2m
1m
0m
1m
2m 3m
4m
AB25S2SC1FA AB35S2SC1FA
18
2.7m
2m
1m
0m
1.5m/s
1.5m/s
1.0m/s
1.0m/s
0.5m/s
2m2m
1m
1m
4m
3m
3m
4m
0m
0.5m/s
c. Heating / Air Velocity Distribution
Heating
Blowy angle:70
Air velocity Distribution
d. Heating / Temperature Distribution
Heating
Blowy angle:70
Temperature Distribution
22
27
25
22
25
27
4m
3m
2m2m
1m
1m
3m
4m
0m
2.7m
2m
1m
0m
/