Unbranded Wireless Remote Controller, Controllers and Accessories Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Unbranded Wireless Remote Controller Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Wired Remote Controller WRC3 and
Wireless Remote Controller WLRC3
Commercial Air Conditioners
Owner's Manual
NORTEK GLOBAL HVAC, LLC
Please read this owner's manual carefully before operation and retain for future reference.
6SHFL¿FDWLRQVLOOXVWUDWLRQVVXEMHFWWRFKDQJHZLWKRXWQRWLFHRULQFXUULQJREOLJDWLRQV
If you have lost the owners manual, please visit www.NortekHVAC.com for electronic version.
User Notice
ƹ
'RQRWLQVWDOOUHPRWHFRQWUROOHULQKXPLGHQYLURQPHQW$YRLGH[SRVXUHWRGLUHFWVXQOLJKW
ƹ
Do not throw, drop, or mishandle remote controller.
ƹ
Do not operate remote controller with wet hands.
Please read the manual carefully before using and installing this product.
Children and persons with reduced mental, sensory or physical capabilities should not be
allowed to operate or maintain this equipment.
,IWKHSRZHUFRUGLVGDPDJHGLWPXVWEHUHSODFHGE\DQHZFRUGWKDWPHHWVWKHVDPH
VWDQGDUGVDVWKHRULJLQDO,WPXVWEHLQVWDOOHGE\DTXDOL¿HGSURIHVVLRQDO)DLOXUHWRFRPSO\FRXOG
UHVXOWLQGDPDJHWRWKHHTXLSPHQWRUFDXVHDILUH7KLVSURGXFWPXVW QRWEH GLVSRVHGRWKHU
household waste. Please dispose of properly.
Contents
ĉ
Wired Remote Controller WRC3 .................................................................... 1
1 Symbols on LCD ........................................................................................... 1
1.1 Outside View of the Wired Remote Controller ...................................................... 1
1.2 LCD of the Wired Remote Controller .................................................................... 1
2 Buttons ......................................................................................................... 2
2.1 Buttons on the Wired Remote Controller .............................................................. 2
)XQFWLRQRIWKH%XWWRQV ......................................................................................... 3
3 Operation Instructions ..................................................................................... 4
3.1 On/Off ...................................................................................................................4
0RGH6HWWLQJ ......................................................................................................... 4
7HPSHUDWXUH6HWWLQJ .............................................................................................. 4
)DQ6HWWLQJ ............................................................................................................ 5
7LPHU6HWWLQJ ......................................................................................................... 5
6ZLQJ6HWWLQJ ........................................................................................................ 7
6OHHS6HWWLQJ ......................................................................................................... 8
7XUER6HWWLQJ ......................................................................................................... 9
(KHDWHU6HWWLQJ .................................................................................................. 10
%ORZ6HWWLQJ ...................................................................................................... 11
2WKHU)XQFWLRQV ................................................................................................. 12
4 Installation and Dismantlement .................................................................. 13
&RQQHFWLRQRIWKH6LJQDO/LQHRIWKH:LUHG5HPRWH&RQWUROOHU .......................... 13
4.2 Installation of the Wired Remote Controller ........................................................ 13
4.3 Dismantlement of the Wired Remote Controller ................................................. 15
5 Errors Display .............................................................................................. 15
Ċ
Wireless Remote Controller WLRC3 ........................................................... 17
)XQFWLRQRI3UHVV%XWWRQV .......................................................................... 17
2 Guide for General Operation ...................................................................... 19
3 Guide for Optional Operation .....................................................................20
Wired Remote Controller WRC3
1
ĉ
Wired Remote Controller WRC3
1 Symbols on LCD
1.1 Outside View of the Wired Remote Controller
Enter/cancel
Enter/Cancel
Fan
Mode
Function
Timer
On/Off
SHIELD
MEMORY
MASTER
SAVE
BLOW
QUIET
CO
2
AUTO TURBO
SET
HOUR
F
E-HEATER
A
U
T
O
)LJ2XWVLGH9LHZRIWKH:LUHG5HPRWH&RQWUROOHU
1.2 LCD of the Wired Remote Controller
SHIELD
MEMORY
MASTER
SAVE
BLOW
QUIET
CO
2
AUTO TURBO
SET
HOUR
F
E-HEATER
A
U
T
O
12
3
4
5
6
7
8
9
10
1211
13 14
15 16
17 18 19
)LJ/&'RIWKH:LUHG5HPRWH&RQWUROOHU
Wired Remote Controller WRC3
2
7DEOH
No. Symbols Description
1
6ZLQJIXQFWLRQ
2
Sleep function (Only sleep 1).
3
5XQQLQJPRGHVRIWKHLQGRRUXQLW&RROLQJ'U\)DQDQG+HDWLQJ
4
'HIURVWLQJIXQFWLRQIRUWKHRXWGRRUXQLW
5
Gate-control function (this function is yet unavailable for this unit).
6
Lock function.
7
+LJKPLGGOHORZRUDXWRIDQVSHHGRIWKHLQGRRUXQLW
8
Shield functions (buttons, temperature, On/Off or Mode is shielded
by the remote monitor.
9
7XUERIXQFWLRQ
10
0HPRU\IXQFWLRQ7KHLQGRRUXQLWUHVXPHVWKHRULJLQDOVHWWLQJVWDWH
after power failure and then power recovery).
11
Master wired remote controller (this function is yet unavailable for
this unit).
12 It blinks under on state of the unit without operation of any button.
13
(QHUJ\VDYLQJIXQFWLRQWKLVIXQFWLRQLV\HWXQDYDLODEOHIRUWKLVXQLW
14
Ambient/preset temperature value.
15
(OHFWULFDX[LOLDU\KHDWLQJIXQFWLRQ
16
Blow function.
17
7LPLQJYDOXH
18
Quiet function (two types: quiet and auto quiet)
(this function is yet unavailable for this unit).
19 6(7 ,WZLOOEHGLVSOD\HGXQGHUWKHGHEXJJLQJPRGH
2 Buttons
2.1 Buttons on the Wired Remote Controller
Enter/cancel
Enter/Cancel
Fan
Mode
Function
Timer
On/Off
123
4
5
6
7
8
)LJ%XWWRQVRQWKH:LUHG5HPRWH&RQWUROOHU
Wired Remote Controller WRC3
3
)XQFWLRQRIWKH%XWWRQV
7DEOH
No. Name )XQFWLRQ
1 Enter/Cancel )XQFWLRQVHOHFWLRQDQGFDQFHOODWLRQ
2 Ÿ
ķ
5XQQLQJWHPSHUDWXUHVHWWLQJRIWKHLQGRRUXQLWUDQJH
̚
30
ć
ĸ
7LPHUVHWWLQJUDQJHKU
6 ź
3 )DQ 6HWWLQJRIWKHKLJKPLGGOHORZDXWRIDQVSHHG
4 Mode 6HWWLQJRIWKH&RROLQJ+HDWLQJ)DQ'U\$XWRPRGHRIWKHLQGRRUXQLW
5 )XQFWLRQ 6ZLWFKRYHUDPRQJWKHIXQFWLRQVRI7XUER
/Save/E-heater/Blow etc.
7 7LPHU 7LPHUVHWWLQJ
8 On/Off 7XUQRQRIIWKHLQGRRUXQLW
4+2 Ÿ0RGH
Press and hold for 5s under off state of the unit to Enter/Cancel the Memory
function(If memory is set, indoor unit after power failure and then power
UHFRYHU\ZLOOUHVXPHWKHRULJLQDO VHWWLQJVWDWH,IQRWWKHLQGRRUXQLWLV GH-
faulted to be off after power recovery. Memory off is default before delivery.).
3
+6
)DQź
%\SUHVVLQJWKHPDWWKHVDPHWLPHXQGHURIIVWDWHRIWKHXQLW
will be dis-
SOD\HGRQWKHZLUHGUHPRWHFRQWUROOHUIRUWKHFRROLQJRQO\XQLWZKLOH
will
EHGLVSOD\HGRQWKHZLUHGUHPRWHFRQWUROOHUIRUWKHFRROLQJDQGKHDWLQJXQLW
2
+6
Ÿź
After successful startup or under off state of the unit,press and hold both
keys for 5s to enter the lock state, in which case, any other buttons won’t
respond. Repress and hold both keys for 5s to quit this state.
4+6 0RGHź
8QGHU2))VWDWHWKH&HOVLXV DQG)DKUHQKHLWVFDOHVFDQEH VZLWFKHGE\
SUHVVLQJ³0RGH´DQG³ź´IRU¿YHVHFRQGV
5+7 )XQFWLRQ7LPHU
8QGHU2))VWDWH \RXFDQVHOHFW FRPPLVVLRQLQJVWDWXVE\SUHVVLQJ³)XQF-
WLRQ´DQG³7LPHU´IRU¿YHVHFRQGV,I³´LVQRW VKRZQRQWKHWHPSHUDWXUH
GLVSOD\FRQWLQXHWRSUHVV ³0RGH´XQWLOLWDSSHDUV7KHQDGMXVWWKHRSWLRQV
ZKLFKLVVKRZQRQWKHWLPHUDUHDE\SUHVVLQJ³Ÿ´DQG³ź´7KHUHDUHIRXU
options, as follows:
ķ
Indoor ambient temperature is sensed by the return air temperature sen-
sor ( 01 displayed on the timer area).
ĸ
Indoor ambient temperature is sensed by the wired controller (02 dis-
played on the timer area).
Ĺ
7KHUHWXUQDLUWHPSHUDWXUHVHQVRU LVVHOHFWHGXQGHUWKHFRROLQJ GU\RU
fan mode; while the wired controller temperature sensor is selected under
WKHKHDWLQJRUDXWRPRGHLVGLVSOD\HGRQWKHWLPHUDUHD
ĺ
7KHZLUHGFRQWUROOHUWHPSHUDWXUHVHQVRU LVVHOHFWHGXQGHUWKHFRROLQJ
dry, or fan mode; while the return air temperature sensor is selected under
WKHKHDWLQJPRGHLVGLVSOD\HGRQWKHWLPHUGLVSOD\DUHD
5+7 )XQFWLRQ7LPHU
8QGHU2))VWDWH \RXFDQVHOHFW FRPPLVVLRQLQJVWDWXVE\SUHVVLQJ³)XQF-
WLRQ´DQG³7LPHU´IRU¿YHVHFRQGV3UHVV³0RGH´EXWWRQWRXQWLO³´LFRQLV
VKRZQDWWKHWHPSHUDWXUHGLVSOD\DUHD7KHVHWWLQJVWDWXVZLOOEHVKRZQDW
WLPHUDUHD3UHVV³Ÿ´DQG ³ź´EXWWRQWRDGMXVWDQGWZRRSWLRQVDUH DYDLO-
able:
ķ
7KUHHORZOHYHOV
ĸ
7KUHHKLJKOHYHOV
Wired Remote Controller WRC3
4
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
1RWH7KHVWDWH VKRZQLQ )LJLQGLFDWHV WKH³2II´VWDWHRIWKHXQLWDIWHUSRZHURQ7KHVWDWH
VKRZQLQ)LJLQGLFDWHVWKH³2Q´VWDWHRIWKHXQLWDIWHUSRZHURQ
AUTO
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
)LJ³2II´6WDWH)LJ³2Q´6WDWH
0RGH6HWWLQJ
8QGHUWKH³2Q´VWDWHRIWKHXQLWSUHVV 0RGHWR VZLWFKWKH RSHUDWLRQPRGHVDVWKH IROORZLQJ
VHTXHQFH$XWR&RROLQJ'U\)DQ+HDWLQJ
Auto Cooling
Dry Fan
Heating
7HPSHUDWXUH6HWWLQJ
3UHVVŸRUźWRLQFUHDVHGHFUHDVHWKHSUHVHWWHPSHUDWXUH3UHVVDQGKROGHLWKHUEXWWRQDQG
the temperature will be increased or decreased by 1
ć
every 0.5s
DVVKRZQLQ)LJ
,QWKH&RROLQJ'U\)DQRU+HDWLQJPRGHWKHWHPSHUDWXUHVHWWLQJUDQJHLV
ć̚
30
ć
,QWKH$XWRPRGHWKHVHWWLQJWHPSHUDWXUHLVQRWDGMXVWDEOH
Wired Remote Controller WRC3
5
Enter/Cancel
Fan Mode
Function Timer
On/Off
AUTO
)LJ
)DQ6HWWLQJ
8QGHUWKH³2Q´´2II´VWDWHRI WKHXQLW SUHVV)DQ DQGWKHQIDQVSHHG RIWKH LQGRRUXQLW ZLOO
FKDQJHFLUFXODUO\DVVKRZQLQ)LJ
Low Middle
High
Enter/Cancel
Fan Mode
Function
Timer
On/Off
AUTO
)LJ
Wired Remote Controller WRC3
6
7LPHU6HWWLQJ
8QGHUWKH³2Q´´2II´VWDWHRIWKHXQLWSUHVV7LPHUWRVHWWLPHURIIRQ
7LPHURQVHWWLQJSUHVV7LPHU/&'ZLOOGLVSOD\³[[[KRXU´ZLWK³KRXU´EOLQNLQJ,QWKLV FDVH
SUHVVŸRUźWRDGMXVWWKHWLPLQJYDOXH7KHQSUHVV(QWHU&DQFHOWRFRQ¿UPWKHVHWWLQJ
7LPHURIIVHWWLQJSUHVV7LPHU/&'WLPHUGLVSOD\ZLOOGLVDSSHDU
7LPHURIIVHWWLQJXQGHUWKH³2Q´VWDWHRIWKHXQLWLVVKRZQDV)LJ
HOUR
AUTO AUTO
Turn on the unit,without setting timer
Press “Timer”button to set
Press “Increase”or
button to adjust time
“Decrease”
Press “Timer” button to cancel
timer setting
Press “Enter/Cancel”to finish
timer setting
HOUR
AUTO
Enter/Cancel
Fan Mode
Function
Timer
On/Off
HOUR
AUTO
Enter/Cancel
Fan Mode
Function Timer
On/Off
AUTO
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
)LJ7LPHURII6HWWLQJXQGHUWKH³2Q´6WDWHRIWKH8QLW
7LPHUUDQJHKU(YHU\SUHVVRIŸRUźZLOOPDNHWKHVHWWLPHLQFUHDVHGRUGHFUHDVHGE\
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.
Wired Remote Controller WRC3
7
6ZLQJ6HWWLQJ
6ZLQJ2Q3UHVV)XQFWLRQXQGHURQVWDWHRIWKHXQLWWRDFWLYDWHWKHVZLQJIXQFWLRQ,QWKLVFDVH
ZLOOEOLQN$IWHUWKDWSUHVV(QWHU&DQFHOWRPDNHDFRQ¿UPDWLRQ
6ZLQJ2II:KHQWKH6ZLQJIXQFWLRQLVRQSUHVV)XQFWLRQWRHQWHUWKH6ZLQJVHWWLQJLQWHUIDFH
with
EOLQNLQJ$IWHUWKDWSUHVV(QWHU&DQFHOWRFDQFHOWKLVIXQFWLRQ
6ZLQJVHWWLQJLVVKRZQDV)LJ
Enter/Cancel
Fan Mode
Function Timer
On/Off
Turn on the unit,without turning on
swing function
Press ”button into swing stateFunction
Press “Enter/Cancel” to confirm
Press “Enter/Cancel” to cancel swing
Press “Function”button into swing state
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
)LJ6ZLQJ6HWWLQJ
Note:
ķ
6OHHS7XUERRU%ORZIXQFWLRQVDUHHQJDJHGWKHVDPHDVWKH6ZLQJVHWWLQJ
ĸ
$IWHUVHOHFWLQJWKHGHVLUHG VHWWLQJSUHVV WKH³(QWHU&DQFHO´ EXWWRQZLWKLQVHFRQGVWR
FRQ¿UP
Wired Remote Controller WRC3
8
6OHHS6HWWLQJ
6OHHSRQ3UHVV)XQFWLRQXQGHURQ VWDWHRI WKHXQLW WLOOWKH XQLWHQWHUV WKH6OHHS VHWWLQJ
LQWHUIDFH3UHVV(QWHU&DQFHOWRFRQ¿UPWKHVHWWLQJ
6OHHSRII:KHQ WKH6OHHSIXQFWLRQLVDFWLYDWHGSUHVV)XQFWLRQWRHQWHUWKH6OHHSVHWWLQJ
interface. After that, press Enter/Cancel to cancel this function.
,QWKH&RROLQJRU'U\PRGHWKHWHPSHUDWXUHZLOOLQFUHDVHE\
ć
after the unit runs under Sleep
1 for 1hr and 1
ć
after another 1hr. After that, the unit will run at this temperature.
,QWKH+HDWLQJPRGHWKHWHPSHUDWXUHZLOOGHFUHDVHE\
ć
after the unit runs under Sleep 1 for
1hr and 1
ć
after another 1hr. After that, the unit will run at this temperature.
6OHHSVHWWLQJLVVKRZQDV)LJ
AUTO AUTO
AUTO
AUTO
Turn on the unit,without turning on sleep
Press ”button into sleepFunction
Press “Function” button into sleep
Press “Enter/Cancel”to cancel sleep
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
AUTO
Press “Enter/Cancel”button to
turn on sleep
Enter/Cancel
Fan Mode
Function Timer
On/Off
)LJ6OHHS6HWWLQJ
Wired Remote Controller WRC3
9
7XUER6HWWLQJ
7XUERIXQFWLRQ7KHV\VWHPFDQUXQDWKLJKIDQVSHHGWRPRUHTXLFNO\KHDWFRROWKHURRPWRWKH
desired temperature.
,QWKH&RROLQJRU+HDWLQJPRGHSUHVV)XQFWLRQWLOOWKHXQLWHQWHUVWKH7XUERVHWWLQJLQWHUIDFH
DQGWKHQSUHVV(QWHU&DQFHOWRFRQ¿UPWKHVHWWLQJ
:KHQWKH7XUERIXQFWLRQLVDFWLYDWHGSUHVV)XQFWLRQWRHQWHUWKH7XUERVHWWLQJLQWHUIDFHDQG
then press Enter/Cancel to cancel this function.
7XUERIXQFWLRQVHWWLQJLVDVVKRZQLQ)LJ
Enter/cancel
Fan Mode
Function Timer
On/Off
Enter/cancel
Fan Mode
Function Timer
On/Off
Enter/cancel
Fan Mode
Function Timer
On/Off
Enter/cancel
Fan Mode
Function Timer
On/Off
TURBO
TURBO
Turn on the unit,without turning on turbo
Press“ ”button into stateFunction turbo
Press “Enter/cancel”to
turbo function
turn on
Press “Enter/Cancel”to turn off
turbo function
Press “Function”button into turbo
state
Enter/cancel
Fan Mode
Function Timer
On/Off
TURBO
)LJ7XUER6HWWLQJ
Wired Remote Controller WRC3
10
(KHDWHU6HWWLQJ
(KHDWHUDX[LOLDU\HOHFWULFKHDWLQJIXQFWLRQ,QWKH+HDWLQJPRGH(KHDWHULVDOORZHGWREH
WXUQHGRQIRULPSURYHPHQWRIHI¿FLHQF\
2QFHWKHZLUHGUHPRWHFRQWUROOHURUWKHUHPRWHFRQWUROOHUHQWHUVWKH+HDWLQJPRGHWKLVIXQFWLRQ
will be turned on automatically.
3UHVV)XQFWLRQLQWKH+HDWLQJPRGHWRHQWHUWKH(KHDWHUVHWWLQJLQWHUIDFHDQGWKHQSUHVV
Enter/Cancel to cancel this function.
3UHVV)XQFWLRQWRHQWHUWKH(KHDWHUVHWWLQJLQWHUIDFHLIWKH(KHDWHUIXQFWLRQLVQRWDFWLYDWHG
and then press Enter/Cancel to turn it on.
7KHVHWWLQJRIWKLVIXQFWLRQLVVKRZQDV)LJEHORZ
E-HEATER
E-HEATER
Auxiliary electric heating function
will be automatically turned on
under heating mode
Press ”button into this functionFunction
Press “Enter/Cancel”button to
turn off this function
Press “Function” button into auxiliary
electric heating function
Press “Enter/Cancel”button to
turn on this function
Enter/Cancel
Fan Mode
Function Timer
On/Off
E-HEATER
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function
Timer
On/Off
AUTO
Enter/Cancel
Fan Mode
Function Timer
On/Off
E-HEATER
)LJ(KHDWHU6HWWLQJ
Wired Remote Controller WRC3
11
%ORZ6HWWLQJ
Blow function: After unit cycles off, the blower will continue to run for 2 minutes to evaporate
DQ\PRLVWXUHWKDWKDVFRQGHQVHGRQWKHLQGRRUFRLO'U\LQJWKHLQGRRUFRLODYRLGVPLOGHZ
,QWKH&RROLQJRU 'U\PRGH SUHVV)XQFWLRQ WLOOWKHXQLWHQWHUVWKH%ORZVHWWLQJLQWHUIDFHDQG
then press Enter/Cancel to active this function.
:KHQWKH%ORZIXQFWLRQLVDFWLYDWHG SUHVV)XQFWLRQ WRWKH %ORZVHWWLQJ LQWHUIDFHDQG WKHQ
press Enter/Cancel to cancel this function.
%ORZIXQFWLRQVHWWLQJLVDVVKRZQLQ)LJ
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
Enter/Cancel
Fan Mode
Function Timer
On/Off
BLOW
BLOW
BLOW
Turn on the unit,without turning
on blow function
Press ”button into blow stateFunction
Press ”button to
turn on blow function
Enter/Cancel
Press“Enter/Cancel” button to
turn off blow funtion
Press “Function” button into blow state
AUTO AUTO
AUTO
AUTO
AUTO
)LJ%ORZ6HWWLQJ
Notes:
ķ
:KHQWKH%ORZIXQFWLRQ LVDFWLYDWHG DIWHUWXUQLQJ RIIWKHWKHV\VWHPE\SUHVVLQJ2Q
Off on the unit or remote controller, the indoor fan will run at the low fan speed for 2 min, with
³%/2:´GLVSOD\HGRQWKH/&':KLOHLQ%ORZPRGHLIIXQFWLRQLVFDQFHOOHGWKHEORZHUZLOOWXUQRII
immediately.
ĸ
%ORZIXQFWLRQLVXQDYDLODEOHLQWKH)DQRU+HDWLQJPRGH
Wired Remote Controller WRC3
12
2WKHU)XQFWLRQV
(1). Lock
$IWHUVXFFHVVIXOVWDUWXSRUXQGHUWKH³2II´VWDWHRIWKHXQLWSUHVVŸDQGź
at the same time for
5s till the wired remote controller enters the Lock function. In this case, LCD displays
.
After that,
repress these two buttons at the same time for 5s to quit this function.
8QGHUWKH/RFNVWDWHDQ\RWKHUEXWWRQSUHVVZRQ¶WJHWDQ\UHVSRQVH
(2). Memory
0HPRU\VZLWFKRYHU8QGHUWKH³2II´VWDWHRIWKHXQLWSUHVV0RGHDQGŸDWWKHVDPHWLPHIRU
5s to switch memory states between memory on and memory off. When this function is activated,
0HPRU\ZLOOEHGLVSOD\HG,IWKLVIXQFWLRQLVQRWVHWWKHXQLWZLOOEHXQGHUWKH³2II´VWDWHDIWHUSRZHU
failure and then power recovery.
Memory recovery: If this function has been set after power failure the remote controller will
UHVXPHLWVRULJLQDOUXQQLQJ VWDWHXSRQ SRZHUUHFRYHU\0HPRU\FRQWHQWV2Q2II0RGH VHW
temperature, set fan speed and Lock function.
(3). 6HOHFWLRQRIWKH7HPSHUDWXUH6HQVRU
8QGHU2))VWDWHRIWKHXQLW SUHVVERWK ³)XQFWLRQ´DQG ³7LPHU´IRUILYHVHFRQGVWRJRWKH
FRPPLVVLRQLQJVWDWXV8QGHUWKLVVWDWXVDGMXVWWKHGLVSOD\LQWKHWHPSHUDWXUHGLVSOD\DUHDWR³´
WKURXJKWKHEXWWRQ³0RGH´DQGWKHQDGMXVWWKHRSWLRQRIWKHWHPSHUDWXUHVHQVRULQWKHWLPHUGLVSOD\
DUHDWKURXJKWKHEXWWRQŸRUź
ķ
Indoor ambient temperature is sensed at the return air inlet(01 in the timer display area).
ĸ
Indoor ambient temperature is the sensed at the wired controller(02 in the timer display area).
Ĺ
6HOHFWWKHWHPSHUDWXUHVHQVRUDWWKHUHWXUQDLULQOHWXQGHUWKHFRROLQJGU\DQGIDQPRGHV
ZKLOHVHOHFWWKHWHPSHUDWXUHVHQVRUDWWKHZLUHGFRQWUROOHUXQGHUWKHKHDWLQJDQGDXWR
modes.(03 in the timer display area).
ĺ
6HOHFWWKHWHPSHUDWXUHVHQVRUDWWKHZLUHGFRQWUROOHUXQGHUWKHFRROLQJGU\DQGIDQPRGHV
DQGVHOHFWWKHWHPSHUDWXUHVHQVRUDWWKHUHWXUQDLULQOHWXQGHUWKHKHDWLQJPRGHDQGDXWR
modes (04 displayed in the timer display area).
7KHIDFWRU\GHIDXOWHGVHWWLQJLV
Ĺ
.
$IWHUWKHVHWWLQJSUHVV³(QWHU&DQFHO´WRPDNHDFRQ¿UPDWLRQDQGTXLWWKLVVHWWLQJVWDWXV
3UHVVLQJWKHEXWWRQ³2Q2II´DOVRFDQTXLWWKLVFRPPLVVLRQLQJVWDWXVEXWWKHVHWGDWDZRQ¶WEH
saved.
8QGHUWKHFRPPLVVLRQLQJVWDWXVLIWKHUHLVQRDQ\RSHUDWLRQLQVHFRQGVDIWHUWKHODVWEXWWRQ
SUHVVLWZLOOUHYHUWWRWKHSUHYLRXVVWDWHZLWKRXWVDYLQJWKHFXUUHQWGDWD
(4). 6HOHFWLRQRIWKH)DQ6SHHG
8QGHU2))VWDWHRIWKHXQLWSUHVVERWKWKHEXWWRQV³)XQFWLRQ´DQG³7LPHU´IRU¿YHVHFRQGVWR
JRWRWKHFRPPLVVLRQLQJVWDWXVDQGWKHQDGMXVWWKHGLVSOD\LQWKHWHPSHUDWXUHGLVSOD\DUHDWR
WKURXJKWKHEXWWRQ³0RGH´DQGDGMXVWWKHVHWWLQJRIWKHIDQVSHHGZKLFKFRPHVWRWZRRSWLRQV
7KUHHORZIDQVSHHGV7KUHHKLJKIDQVSHHGV
$IWHUWKHVHWWLQJSUHVV³(QWHU&DQFHO´WRPDNHDFRQ¿UPDWLRQDQGTXLWWKLVVHWWLQJVWDWXV
3UHVVLQJWKHEXWWRQ³2Q2II´DOVRFDQTXLWWKLVFRPPLVVLRQLQJVWDWXVEXWWKHVHWGDWDZRQ¶WEHVDYHG
8QGHUWKHFRPPLVVLRQLQJVWDWXVLIWKHUHLVQRDQ\RSHUDWLRQLQVHFRQGVDIWHUWKHODVWEXWWRQ
SUHVVLWZLOOUHYHUWWRWKHSUHYLRXVVWDWHZLWKRXWVDYLQJWKHFXUUHQWGDWD
Wired Remote Controller WRC3
13
4 Installation and Dismantlement
&RQQHFWLRQRIWKH6LJQDO/LQHRIWKH:LUHG5HPRWH&RQWUROOHU
Ɣ Open the cover of the electric control box of the indoor unit.
Ɣ /HDGWKHVLQJOHOLQHRIWKHZLUHGUHPRWHFRQWUROOHUWKURXJKWKHUXEEHUULQJ
Ɣ &RQQHFWWKHVLJQDOOLQHRIWKHZLUHGUHPRWHFRQWUROOHUWRWKHSLQVRFNHWRIWKHLQGRRUXQLW
PCB.
Ɣ 7LJKWHQWKHVLJQDOZLUHZLWKWLHV
Ɣ 7KHFRPPXQLFDWLRQGLVWDQFHEHWZHHQWKHPDLQERDUGDQGWKHZLUHGUHPRWH FRQWUROOHUFDQ
be up to 20 meters ( the standard distance is 8 meters)
4.2 Installation of the Wired Remote Controller
1 3 4 52
PVC Pipe
)LJ$FFHVVRULHVIRUWKH,QVWDOODWLRQRIWKH:LUHG5HPRWH&RQWUROOHU
7DEOH
No. 1 2 3 4 5
Name
Socket box
embedded
in the wall
Soleplate of the
Wired Remote
Controller
Screw
M4X25
)URQW3DQHORIWKH
Wired Remote
Controller
6FUHZ67;
Wired Remote Controller WRC3
14
)LJ
)LJVKRZVWKHLQVWDOODWLRQVWHSVRIWKHZLUHGUHPRWHFRQWUROOHUEXWWKHUHDUHVRPHLVVXHVWKDWQHHG\RXUDWWHQWLRQ
(1). Prior to the installation, please turn off power supply to the wired controller.
(2). 3XOORXWWKHIRXUFRUHWZLVWHGSDLUOLQHIURPWKHLQVWDOODWLRQKROHVDQGWKHQOHDGLWWKURXJK
WKHUHFWDQJXODUKROHEHKLQGWKHVROHSODWHRIWKHZLUHGUHPRWHFRQWUROOHU
(3). Stick the soleplate of the wired remote controller to the wall over the installation hole and
WKHQ¿[LWZLWKVFUHZV0;
(4). Insert the four-core twisted pair line into the slot of the wired remote controller and then
EXFNOHWKHIURQWSDQHODQGWKHVROHSODWHRIWKHZLUHGUHPRWHFRQWUROOHUWRJHWKHU
(5). )LQDOO\¿[WKHIURQWSDQHODQGWKHVROHSODWHRIWKHZLUHGUHPRWHFRQWUROOHUWLJKWO\E\VFUHZV
67;
CAUTION!
3OHDVHSD\VSHFLDODWWHQWLRQWRWKHIROORZLQJVGXULQJWKHFRQQHFWLRQWRDYRLGPDOIXQFWLRQRIWKH
DLUFRQGLWLRQLQJXQLWGXHWRHOHFWURPDJQHWLFLQWHUIHUHQFH
Wired Remote Controller WRC3
15
ķ
6HSDUDWHWKHVLJQDODQGFRPPXQLFDWLRQOLQHVRIWKHZLUHGUHPRWHFRQWUROOHUIURPWKHSRZHU
cord and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm.
ĸ
,IWKHDLUFRQGLWLRQLQJXQLWLVLQVWDOOHGZKHUHLVVXEMHFWWRHOHFWURPDJQHWLFLQWHUIHUHQFHWKHQ
WKHVLJQDODQGFRPPXQLFDWLRQOLQHVRIWKHZLUHGUHPRWHFRQWUROOHUPXVWEHVKLHOGHG
4.3 Dismantlement of the Wired Remote Controller
5 Errors Display
,IDQHUURURFFXUVGXULQJRSHUDWLRQRIWKHV\VWHPWKHHUURUFRGHZLOOEHGLVSOD\HGRQWKH/&'
DVVKRZLQ)LJ,IPXOWLSOHHUURUVRFFXUDWWKHVDPHWLPHWKHLUFRGHVZLOOEHGLVSOD\HGFLUFXODUO\
Note: In event of any error, please turn off the unit and contact the professionally skilled
personnel.
Enter/cancel
Enter/cancel
Fan
Mode
Function
Timer
On/Off
)LJ
Wired Remote Controller WRC3
16
7DEOH0HDQLQJRI(DFK(UURU
Error
Error
Code
Error
Error
Code
Return air temperature sensor open/short
circuited
) Drive board communication error P6
Evaporator temperature sensor open/short
circuited
) &RPSUHVVRURYHUKHDWLQJSURWHFWLRQ H3
Indoor unit liquid valve temperature sensor
open/short circuited
b5 Indoor and outdoor units unmatched LP
,QGRRUJDVYDOYHWHPSHUDWXUHVHQVRU RSHQ
short circuited
b7
Communication line misconnected or
expansion valve error
dn
IPM temperature sensor open/short circuited P7 5XQQLQJPRGHFRQÀLFW E7
Outdoor ambient temperature sensor open/
short circuited
) Pump-down )R
Outdoor unit condenser mid-tube temperature
sensor open/short circuited
) Defrost or oil return
'LVFKDUJHWHPSHUDWXUHVHQVRURSHQVKRUW
circuited
) )RUFHGGHIURVWLQJ H1
Indoor and outdoor communication error E6 Compressor startup failure Lc
'&EXVXQGHUYROWDJHSURWHFWLRQ PL +LJKGLVFKDUJHWHPSHUDWXUHSURWHFWLRQ E4
'&EXVRYHUYROWDJHSURWHFWLRQ PH Overload protection E8
&RPSUHVVRUSKDVHFXUUHQWVHQVLQJFLUFXLW HU-
ror
U1 Whole unit over-current protection E5
&RPSUHVVRUGHPDJQHWL]DWLRQSURWHFWLRQ HE Over phase current protection P5
3)&SURWHFWLRQ Hc &RPSUHVVRUGHV\QFKURQL]LQJ H7
,307HPSHUDWXUH3URWHFWLRQ P8 IPM Current protection H5
Over-power protection L9
Compressor phase loss/reversal protec-
tion
Ld
6\VWHPFKDUJHVKRUWDJHRUEORFNDJHSURWHF-
tion
)
)UHTXHQF\UHVWULFWHGUHGXFHGZLWKZKROH
unit current protection
)
&DSDFLWRUFKDUJLQJHUURU PU
)UHTXHQF\UHVWULFWHGUHGXFHGZLWK,30
current protection
En
+LJKSUHVVXUHSURWHFWLRQ E1
)UHTXHQF\UHVWULFWHGUHGXFHGZLWKKLJK
GLVFKDUJHWHPSHUDWXUH
)
Low pressure protection E3
)UHTXHQF\UHVWULFWHGUHGXFHGZLWKDQWL
IUHH]LQJSURWHFWLRQ
)+
&RPSUHVVRUVWDOOLQJ LE
)UHTXHQF\UHVWULFWHGUHGXFHGZLWKRYHU-
load protection
)
2YHUVSHHGLQJ /)
)UHTXHQF\UHVWULFWHGUHGXFHGZLWK,30
temperature protection
EU
Drive board temperature sensor error 3) Indoor unit full water error E9
AC contactor protection P9 $QWLIUHH]LQJSURWHFWLRQ E2
7HPSHUDWXUHGULIWSURWHFWLRQ PE $&LQSXWYROWDJHDEQRUPDO PP
Sensor connection protection Pd :KROHXQLWFXUUHQWVHQVLQJFLUFXLWHUURU U5
'&EXVYROWDJHGURSHUURU U3 ZD\YDOYHUHYHUVLQJHUURU U7
Outdoor fan 1 error protection L3 0RWRUVWDOOLQJ H6
Outdoor fan 2 error protection LA 3*PRWRU]HURFURVVLQJSURWHFWLRQ U8
Wireless Remote Controller WLRC3
17
Ċ
Wireless Remote Controller WLRC3
Notes:
ķ
Be sure that there are no obstructions between the receiver and the remote controller;
ĸ
Do not drop or throw the remote controller;
Ĺ
Do not let any liquid into the remote controller or expose the remote controller to direct
VXQOLJKWRUH[WUHPHKHDW
ĺ
7KLVLVDJHQHUDOXVHUHPRWHFRQWUROOHU,I\RXSUHVVDEXWWRQIRUDIXQFWLRQQRWDYDLODEOH
ZLWKWKHHTXLSPHQWWKHXQLWZLOONHHSWKHRULJLQDOUXQQLQJVWDWXV
)XQFWLRQRI3UHVV%XWWRQV
)LJ
212)) )
Press this button to turn on/off the unit. After that, the sleep function will be canceled but the
preset time is still remained.
2) MODE
$XWR&RRO'U\)DQ+HDWPRGHVFDQEHVHOHFWHGFLUFXODUO\E\SUHVVLQJWKLVEXWWRQ$XWRPRGH
is the default. Under Auto mode, the temperature will not be displayed. Under Heat mode, the initial
value is 28
ć
(82
̧
); Under other modes, the initial value is 25
ć
(77
̧
).
Auto
Cool
Dry
)DQ
+HDW2QO\IRUWKHFRROLQJDQGKHDWLQJXQLW
/