Westinghouse H6HK, 3, 5 Kw 240V,1-Phase Electric Heater Kit Product information

Type
Product information
TERMINAL
BLOCK
(for select
models only)
CIRCUIT
BREAKER
(Circuit breaker
models only)
RELAY
GREY
ORANGE
BLACK
RED
RED
LIMIT
POWER
BLACK
1
2
3
4
5
6
7
BLACK
RED
ELEMENT
SUPPLY VOLTAGE
GROUND
710560B
(Replaces 710560A)
04/15
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
WIRING DIAGRAM
H6HK005H-11 (with circuit breaker)
H6HK003H-01 (without circuit breaker)
H6HK005H-01 (without circuit breaker)
3kW, 5kW, 1-Phase Electric Heater Kit
¢710560w¤
NOTES:
1. If any of the original wire supplied with this unit
must be replaced, it must be replaced with wiring
material of the same gauge size and temperature
rating.
2. The installation of this heater kit may require a change
in the blower speed tap connection. See Installation
Instructions for details.
3. Use copper conductors with a minimum temperature
rating of 60°C for supply connections.
  • Page 1 1