DKS 1835/37 90 Series User manual

Category
Security access control systems
Type
User manual
Copyright 2009 DoorKing, Inc. All rights reserved.
Copyright 2019 DoorKing
®
, Inc. All rights reserved.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Circuit Board
Serial Number
and Revision Letter:
Model Number
Installation/Owner’s Manual
90 Series
Telephone Entry and Access Control Systems
90 Series
90 Series
1837
1837
1837
1835
1835
1835
26, 30 and 31-Bit Wiegand Compatible
For 1837 circuit board:
1837-010 Revision Z or higher.
For 1835 circuit board:
1835-009 Revision Z or higher.
Download REMOTE ACCOUNT MANAGER Software FREE at:
http://www.doorking.com/telephone/software
8 Line LCD Display
Single Line LCD Display
4
7
0
1
5
8
2
6
9
3
A
CALL
Z
Ad
a
ms J
Akins M
An
n
e
se J
>Anderson
H
Ap
p
legate B
Aust
i
n D
Ba
l
s
baugh B
Bass
J
020
115
3
52
>CALL
6
56
078
221
321
4
7
0
1
5
8
2
6
9
3
A
CALL
Z
Ad
a
ms
J
0
20
Conforms To UL STD 294
Certified To CAN/ULC-S319-05
1835-067 Issued 3-19
Version J
2
1835-067 Issued 3-19
Version J
Phone Line Connection
16AC16ACBAT1NO1NC1C2RY2CAZIMC
5VDCIMDSPKRCOMMICPSWCGNDPHONE
1234567891011121314151617181920
Main Terminal
16 VAC Input Power
16 VAC Input Power
Standby Battery POSITIVE
For Phone System Only (12 VDC, .7 Ah, SLA) (connect negative to terminal 6)
Relay 1 Normally Open – 30 Volt, 3 Amp max.
Relay 1 Normally Closed – 30 Volt, 3 Amp max.
Relay 1 Common – 30 Volt, 3 Amp max.
Relay 2 Contact – 30 Volt, 3 Amp max.
Relay 2 Common – 30 Volt, 3 Amp max.
“A” Button Input.
“Z” Button Input.
14 +12 VDC Power.
13 Common.
12 DATA 1.
11 DATA 0.
10 +12 VDC Power.
9 Common.
8 DATA 1.
7 DATA 0.
6 16 VAC Output.
5 16 VAC Output.
4 Standby Battery NEGATIVE (For Wiegand Only).
3 Standby Battery POSITIVE (12 VDC, .7 Ah, SLA).
2 16.5 VAC Input Power – 20 VA.
1 16.5 VAC Input Power – 20 VA.
(Powers RS-232, elevator control and Wiegand)
1 DATA 1 – Connect to terminal 20 of elevator control board.
2 DATA 0 – Connect to terminal 21 of elevator control board.
3 COMMON – Connect to terminal 22 of elevator control board.
Transmit Data 1
Receive Data 2
Request to Send 3
Clear to Send 4
Signal Ground - Shell 5
Not used 6
(Not used).
5 VDC Power for LED lighting.
(Not used).
Speaker Output.
Common for switch input #4, microphone,
speaker, AZ & CALL buttons and battery neg.
Microphone Input.
Switch Input. A closure between terminals 4 and 6 will cause the designated relay(s) to activate for
the programmed strike time or dial a phone number – see 3.2.7. The Postal Switch is connected here.
Earth Ground Only (See Section 2.1.3).
Phone Line Connection
1
2
3
14
12
13
11
10
9
8
7
6
5
4
3
2
1
Aux Terminal
Removable
RS-232
Terminal
Removable
Elevator Control
Terminal
Non-Removable
Relay 0 Terminal
Non-Removable
Note: Connect to the Elevator Control Board (2348-010).
See Elevator Control Board Manual 2348-065 for more info.
100 ft. max. with 18 AWG wire.
200 ft. max. with 16 AWG wire.
20 VA min. for 1835, 40 VA min. for 1837.
800 ft. max. with 24 AWG wire.
1600 ft. max. with 22 AWG wire.
(Wiring MUST be twisted and completely isolated from the ground)
Note: The 14-pin aux terminal can be removed for easy
wiring. Expansion boards are connected here when used.
See Expansion
Tracker Board
Manual
2358-065 and
section 2.3.2,
2.3.3 for more
information.
Note: Located in the upper left corner of circuit
board. The 6-pin terminal can be removed for
easy wiring. Connects a PC (See Section 2.5.1).
Relay 2 Note: Normally Open and
Normally Closed relay jumper is
used to set Relay 2 input on the
circuit board (See section 4.6).
NO
NC
C
Normally Open – 30 Volt, 3 Amp max.
Normally Closed – 30 Volt, 3 Amp max.
Common – 30 Volt, 3 Amp max.
1
2
3
4
5
6
NC
NO
26, 30 and 31 Bit
Wiegand input (Card Reader)
activates Relay 1 for
programmed strike time
26, 30 and 31 Bit
Wiegand input (Card Reader)
activates Relay 2 for
programmed strike time
For card readers that have additional
lighting for outdoor use.
QUICK GUIDE: Terminal Descriptions
See section 2.3 for terminal wiring.
UL 294
Tamper
Switch
Note: Located under microphone
board (See Section 1.7).
Quick Guide - 1
3
1835-067 Issued 3-19
Version J
Quick Guide - 2
No factory setting
1 (255 area codes)
0 (OFF)
007 (7 sec)
1 (tone ON)
1 (19200 Baud)
0 (activates relay)
1 (Turned ON)
Single system
Issued by DoorKing
8-3000 Memory
2-Card w/Anti-Pass Back
Master Code - REQUIRED Programming
Number of Area Codes Allowed
Call-Up Operation, Interfacing with DKS 1816 or 1820 Systems Only
Resident Elevator Button Relay Time
Open Tone ON or OFF
RS-232 Speed Setting
Switch Input Feature
Elevator Control Feature
Single or Multiple Systems
DKS Data over IP Phone Number or System ID Number
Re-Program Memory Size, with/without Cards and Anti-Pass Back
(Only needed when New 1830 system is used with OLDER 1830 systems)
Live Transactions Viewing on a PC - ON or OFF
Section 3.2 Setup Entry System for PC Programming
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.2.9
3.2.10
3.2.11
26
27
27
27
27
28
28
28
28
29
29
*
60
*
78
*
36
*
15
*
85
*
18
*
75
*
04
*
59
*
95
Master
Switch ON
NOT Programmable from Software.
Program from System Keypad ONLY.
3.2.12 OFF30
*
19
Testing Option
Testing Option
Testing Option OFF
Testing
DKS Data
over IP
59
59
59
6.1.7
6.1.8
6.1.9
*
56
*
29
*
55
Display DKS Data over IP Phone Number or System ID Number
Test Connection to DKS Data over IP
Turn DKS Data over IP OFF or ON (Automatically ON after programming 3.2.10)
Page # Factory Setting
Overview for Entry System Keypad Programming
Section Command
No factory setting
Factory message
Factory message
Factory message
Factory message
Programming Letters and Numbers from Keypad
Programming the User Message - 1835 ONLY
Programming the Instruction Message - 1835 ONLY
Programming the User Message - 1837 ONLY
Programming the Instruction Message - 1837 ONLY
Section 3.4 Programming Letters, Numbers and Messages
3.4.1
3.4.2
3.4.3
3.4.4
3.4.5
35
36
37
38
39
None
*
80
*
81
*
80
*
81
No factory setting
No factory setting
No factory setting
No factory setting
Programming Five-Digit Device Codes
Delete Device Codes
Enabling Facility Codes
Programming Facility Codes
Section 3.6 Programming Device Codes
3.6.1
3.6.2
3.6.3
3.6.4
45
45
45
45
*
70
*
71
*
72
*
73
No factory setting
No factory setting
No factory setting
No factory setting
Programming the Anti-Pass Back Mode
Re-Sync All Devices
Re-Sync Individual Devices
Reset Facility Counter
Section 3.8 Anti-Pass Back
3.8.1
3.8.2
3.8.3
3.8.4
47
47
47
47
*
43
*
45
*
46
*
48
No factory setting
No factory setting
No factory setting
Programming Four-Digit Entry Codes
Delete Entry Codes
Entry Code Ranges
Section 3.7 Programming Four-Digit Entry Codes
3.7.1
3.7.2
3.7.3
46
46
46
*
02
*
02
*
12
Three (3) digits
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
1 (Pause ON)
Programming the Directory Code Length
Programming Directory Code AND 7-Digit Phone Numbers - No Area Code
Programming Area Codes
Programming Phone Numbers that need Area Codes
Programming Names
Deleting Individual Phone Numbers
Delete Names
Delete Area Codes
Display Phone Numbers
PBX Line Access Code Programming
Touch-Tone Dialing Pause
Section 3.5 Programming Phone Numbers and Names
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
3.5.9
3.5.10
3.5.11
41
41
42
42
43
43
43
44
44
44
44
*
20
*
01
*
24
*
41
*
66
*
01
*
65
*
24
*
06
*
09
*
27
060 (60 sec)
010 (relay 1 activates)
Touch-tone
010 (relay 1 activates)
Relay Strike Time
Talk Time
Tone Open Numbers
Switch Input Relay(s) Activation
Touch-tone / Rotary-Dial
Rotary Dial-9 Relay(s) Activation
Section 3.3 General Programming using System Keypad
3.3.1
3.3.2
3.3.3
32
32
33
Relay 0: 01 (1 sec)
Relay 1: 01 (1 sec)
Relay 2: 01 (1 sec)
Relay 0: # # # #
Relay 1: 9 8 7 6
Relay 2: 5 4 3 2
*
03
*
08
*
05
3.3.4
3.3.5
3.3.6
33
34
34
*
50
*
07
*
51
4
1835-067 Issued 3-19
Version J
SPECIFICATIONS
Features
Can provide service for up to 3000 residents.
Can store up to 8000 card, transmitter or digital PIN codes.
System can be connected via a Cellular connection using DKS Cellular Services; via the Internet using DKS Data over the
Internet Services for VoIP and/or programming; POTS (Plain Old Telephone Service) using DKS IM Server or your own
modem - Note: DKS does not guarantee modem connections via the PSTN (Public Switched telephone Network).
ONE TOUCH CALLING provides the easiest to use system on the market.
System keypad will emit DTMF tones after a call is answered allowing the system to be used with auto-attendants,
answering machines, etc.
Directory codes can be set from 1 to 4 digits in length and can be randomly assigned.
Transaction buffer stores the last 8000 events and has its own backup power source to retain memory during power
outages.
View the LIVE transactions “real-time” on a PC.
Control the phone entry system relays directly from a PC (Rev Y and higher boards only).
31-security levels total (security level 00 always denies entry, security level 01 always admits entry), with 29 programmable
security levels, each with four time zones allows you to control and restrict user access as needed.
Programmable holiday schedule.
Facility codes can be enabled or disabled. Store up to 10 different facility codes.
True Anti-Pass Back feature.
Up to 255 programmable area codes (Rev E and higher boards only) allow the system to be used in areas requiring
10 and 11-digit dialing.
Three internal relays allow the system to control a main entry point plus two additional entry points.
System can be expanded to control up to 48 entry points in addition to the main entry point. Expansion boards are
required (one for each additional entry point) and are not included with the system. Expansion boards also provide output
for door ajar and forced entry alarms.
Optional elevator control board(s) can control up to four elevators with each elevator serving up to 64 floors.
System will interface with selected models of DKS DoorKing vehicular gate operators to provide gate operator information
and data (requires a Tracker Expansion board for each gate operator that is to send data to the system).
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons
of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights
reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
1835
1837
Included with the system is an extra random keyed cabinet lock. If desired, for added security against
unauthorized entry into the system, the standard lock may be replaced with the random lock.
Note: DoorKing cannot replace this specific lock or keys if lost.
4
7
0
1
5
8
2
6
9
3
A
C
AL
L
Z
4
7
0
1
5
8
2
6
9
3
A
C
ALL
Z
1
1835-067 Issued 3-19
Version J
Table of Contents continued on next page
TABLE OF CONTENTS
Important Notices FCC - United States, DOC - Canada Glossary
General Information Installation Guidelines and Safety Information
SECTION 1 - INSTALLATION
1.1 General Installation
1.2 Remove Components from Enclosure
1.3 Enclosure Dimensions
1.4 Install Enclosure
1.5 Memory Chip Replacement
1.6 Postal Lock Installation
1.7 UL 294 Compliant Tamper Switch
1.8 OPTIONAL Internal Card Reader Installation
1.9 OPTIONAL Camera Kit Installation
1.10 OPTIONAL Heater Installation
SECTION 2 - WIRING
2.1 Wiring Guidelines
2.1.1 Power
2.1.2 Wire Runs
2.1.3 Grounding
2.1.4 Surge Suppression
2.1.5 Expansion Boards and Elevator Control
2.1.6 Ferrite Filter
2.2 Terminal Descriptions
2.3 Telephone Entry System Wiring
2.3.1 ALL telephone Entry Systems - No Tracker Expansion Boards
2.3.2 Hardwired Tracker Expansion Boards
2.3.3 Tracker Expansion Boards using 900 MHz Wireless Communication
2.4 PC (DATA) and VOICE (PHONE) Connection Options
2.4.1 DoorKing Cellular Network Connection - Voice/Data Transfer
2.4.2a DoorKing VoIP/RS-232 Control Box - Voice/Data Transfer
2.4.2b DoorKing VoIP Internet Connection - Voice/Data Transfer
2.4.2c Third Party VoIP Internet Connection - Voice/Data Transfer
2.4.2d DoorKing TCP/IP Converter Mounting Position
2.4.3a DoorKing IM Server Modem Connection - Voice/Data Transfer
2.4.3b Dial-Up Phone Modem Connection - Voice/Data Transfer
2.5 Direct Connection to PC Options - Data Transfer ONLY
2.5.1 RS-232 Direct Connection - Data Transfer ONLY
2.5.2 RS-422/USB Direct Connection to PC - Data Transfer ONLY
2.5.3 TCP/IP Converter Direct Connection to PC - Data Transfer ONLY
SECTION 3 - PROGRAMMING
3.1 General Programming Information
3.1.1 Programming from a PC
3.1.2 Programming from the Telephone Entry System Keypad
3.2 Setup Telephone Entry System for PC Programming
3.2.1 Master Code
3.2.2 Number of Area Codes Allowed
3.2.3 Call-Up Operation when Interfacing with DoorKing 1816 or 1820 Systems
3.2.4 Resident Elevator Button Relay Time
3.2.5 “Tone Open” Sound ON or OFF
3.2.6 RS-232 Speed Setting
3.2.7 Switch Input Feature
3.2.8 Elevator Control Feature
3.2.9 Single or Multiple Systems
3.2.10 DKS Data over IP Phone Number or System ID Number
3.2.11 Re-Program Memory Size, with/without Cards and Anti-Pass Back
3.2.12 LIVE Transaction Viewing from a PC - ON or OFF
Overview for System Keypad Programming
3.3 General Programming using the System Keypad
3.3.1 Relay Strike Time
3.3.2 Talk Time
3.3.3 Tone Open Numbers
3.3.4 Switch Input Relay(s) Activation
3.3.5 Touch-Tone / Rotary-Dial
3.3.6 Rotary-Dial 9 Relay(s) Activation
3.4 Programming Letters, Numbers and Messages
3.4.1 Programming Letters, Numbers from Keypad
3.4.2 Programming the User Message - 1835 System ONLY
3.4.3 Programming the Instruction Message - 1835 System ONLY
3.4.4 Programming the User Message - 1837 System ONLY
3.4.5 Programming the Instruction Message - 1837 System ONLY
3
4
5
5
6
7
8-9
10
11
12
13
13
14
15
15
15
15
16
16
16
16
17
18
18
19
20
21
21
22
22
22
23
23
23
24
24
24
24
25
25
25
25
26
26
27
27
27
27
28
28
28
28
29
29
30
31
32
32
32
33
33
34
34
35
35
36
37
38
39
Quick Quide Terminal Descriptions
Overview for System Keypad Programming
NOT programmable from
Software.
System Keypad
Programming ONLY
System Keypad Programming
when NOT using a PC
Quick Guide - 1
Quick Guide - 2
2
1835-067 Issued 3-19
Version J
TABLE OF CONTENTS
3.5 Programming Phone Numbers and Names
3.5.1 Programming the Directory Code Length
3.5.2 Programming Directory Codes with 7-Digit Phone Number - NO Area Code
3.5.3 Programming Area Codes
3.5.4 Programming Directory Codes with Phone Numbers that use Area Codes
3.5.5 Programming Names
3.5.6 Deleting Individual Phone Numbers
3.5.7 Delete Names
3.5.8 Delete Area Codes
3.5.9 Delete phone Numbers
3.5.10 PBX Line Access Code Programming
3.5.11 Touch-Tone Dial Pause
3.6 Programming Device Codes
3.6.1 Programming Five-Digit Device Codes
3.6.2 Deleting Device Codes
3.6.3 Enabling Facility Codes
3.6.4 Programming Facility Codes
3.7 Programming Four-Digit Entry Codes
3.7.1 Programming Four-Digit Entry Codes
3.7.2 Delete Entry Codes
3.7.3 Entry Code Ranges
3.8 Anti-Pass Back
3.8.1 Programming the Anti-Pass Back Mode
3.8.2 Re-Sync All Devices
3.8.3 Re-Sync Individual Devices
3.8.4 Reset Facility Counter
SECTION 4 - ADJUSTMENTS
4.1 Speaker Volume, Microphone and Feedback
4.2 LCD Display Contrast
4.3 Back-Lite Cutoff
4.4 Master Code Switch
4.5 Ring Pin Jumper
4.6 Relay 2 Jumper
4.7 Auto - 1816 Interface Jumper
4.8 HF - HS Jumper
SECTION 5 - SYSTEM OPERATING INSTRUCTIONS
5.1 Guest Instructions
5.2 Resident Instructions
5.2.1 Responding to a Guest Call
5.2.2 Using an Entry Code
5.3 System Administrator
5.3.1 Connecting to the Telephone Entry System from a Remote Location
5.3.2 Expansion Board Override HOLD OPEN Command
5.3.3 Relay Check
5.3.4 Time and Date Check
5.4 Miscellaneous Operating Instructions
5.4.1 Talk Time
5.4.2 Telephone Line Sharing
5.4.3 Connection to a PBX System
5.4.4 Areas with 10-Digit Dialing
5.4.5 Control Relays Directly from PC
SECTION 6 - MAINTENANCE
6.1 Troubleshooting
6.1.1 RS-232 Test
6.1.2 Wiegand Test
6.1.3 Elevator Control Board(s) Hardware Test
6.1.4 Elevator Board / Floor Hardware Test
6.1.5 Automatic Hang-up Options
6.1.6 Modem Output Level Adjustment
6.1.7 Display
DKS Data over IP Phone Number or System ID Number
6.1.8 Test Connection to
DKS Data over IP
6.1.9 Turn DKS Data over IP ON or OFF
6.2 Accessories
Wiring Schematics 1835 and 1837
SECTION 7 - LOG TABLES
7.1 Programming Information Tables
7.1.1 10 Area Codes
7.1.2 255 Area Codes
7.2 Resident Information
RESIDENT INSTRUCTION SHEET
40
41
41
42
42
42
43
43
44
44
44
44
45
45
45
45
45
46
46
46
46
47
47
47
47
47
48
49
49
49
49
50
50
50
50
51
51
52
52
52
53
53
53
53
53
54
54
54
54
54
54
55
55-56
57
57
57
58
58
58
59
59
59
60
61-62
63
63
63
64-65
66
67
System Keypad Programming when NOT using a PC
Testing
DKS Data
over IP
3
1835-067 Issued 3-19
Version J
FCC – United States
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules and
Regulations. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Registration Number: DUF6VT-12874-OT-T
DOC - Canada
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain
telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate
to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications
company. The equipment must also be installed using an acceptable means of connection. The customer should be aware that compliance
with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or
alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the
user to disconnect the equipment.
Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic
water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or
electrician, as appropriate.
DOC Registration Number: 1736 4507 A
Notice:
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is
used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the require-
ment that the sum of the load numbers of all the devices does not exceed 100.
Notice:
DoorKing does not provide a power transformer on units sold outside of the United States. Use only transformers that are listed by a
recognized testing laboratory to power the telephone entry system. An Inherently Protected Transformer must be used to power this device.
1835 system require a 16.5-volt, 20 VA transformer. The model 1837 requires a 16.5-volt, 40 VA transformer.
Listing:
This product has been tested to and found to be in compliance with the UL 294 Safety Standard and Certified to CAN/ULC-S319-05 by Intertek
Testing Services NA Inc. (a Nationally Recognized Testing Laboratory) and is ETL listed.
ACCESS CONTROL SYSTEM: A collection of means, measures and specific practices that when combined, form or compose a systematic
approach, which enables an authority to control access to areas and resources in a given physical facility. An access control system, within
the field of physical security, is generally seen as the second layer in the security of a physical structure.
ALARM: A condition indicating a state of alert or tamper detection.
ALARM SIGNAL: A transmission of an alarm condition or alarm report.
CONTROLLED AREA: A room, office, building, facility, premises, or grounds to which access is monitored, limited, or controlled.
EQUIPMENT: Any part of an electronic access control system, such as access control units, reader interface modules, access point actuators,
access point sensors, keypads, and the like.
PROTECTED AREA: A room, office, building, facility, premise or grounds to which access is monitored, and limited and/or controlled,
whereby the authorized person of the Access Control System may grant access to non-authorized persons.
RESTRICTED AREA: A room, office, building, facility, premise or grounds to which access is monitored, and limited and strictly controlled,
whereby only the administrator of the Access Control System shall issue credentials that will lead to access.
Important Notices
Glossary
Performance Levels
Destructive Attack: Level I (Level II with Optional Hood Installed)
Line Security: Level I
Endurance: Level IV
Standby Power: Level I (Level II with 12 VDC, .7 Ah, SLA battery, required
Single Point Locking Device with Key Locks: Level I
for Canadian certification)
4
1835-067 Issued 3-19
Version J
Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring
guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner.
The proper installation of the telephone entry panel is an extremely important and integral part of the overall access control system. Check all local
building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes.
When used to control a door or pedestrian gate, try to locate the telephone entry system as near as possible to the entry point. The unit should be
mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration and shock from slamming doors
or spring-loaded pedestrian gates will damage the circuit board.
Under no circumstances should the unit be mounted directly to a moving door or gate.
ADA mounting requirements for door control (Ref: ICC/ANSI A117.1-2009). The requirements below apply ONLY when the telephone entry system is
being used to control entry through A PUBLIC DOOR ONLY. If this system is used to control entry through a vehicular gate or private entrance, the
dimensions noted below do not apply.
When used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of six (6) feet
away from the gate and gate operator, or in such a way that a person cannot operate the entry system and/or touch the gate or gate operator at
the same time.
Be sure that the system is installed so that it is not directly in the traffic lane. Goose neck mounting post and kiosks work well for these type systems.
When planning where to locate the system, take into consideration traffic lane layouts, turn around lanes for rejected access, conduit runs, power
availability, etc.
Environmental factors must also be taken into account. The units are designed for direct outdoor installations, however it is preferable to
protect them from direct exposure to driven rain or snow whenever possible.
This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during
installation or use. Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device.
Instruct the end user to read and follow these instructions. Instruct the end user to never let children play with or operate any access control
device. This Owner’s Manual is the property of the end user and must be left with them when installation is complete.
General Information
1. Unobstructed Forward Reach. Where a clear floor or
ground space allows only a forward approach to an object
and is unobstructed, mounting height shall be a minimum
of 15 inches (381 mm), and a maximum of
48 inches (1.22 m), above the floor or
ground to the operable controls.
48
15”
Minimum
Height
Maximum
Height
3. Unobstructed Side Reach. Where a clear floor or ground
space allows a parallel approach to an object and the side
reach is unobstructed, and the edge of the clear floor space
is 10 inches (255 mm) maximum from the object, mounting
height shall be a minimum of 15 inches (380 mm), and a
maximum of 48 inches (1.22 m), above the floor
or ground to the operable controls.
10”
48
Maximum
Height
Maximum Length of
Clear Floor Space
15”
Minimum
Height
10”
Maximum Length of
Clear Floor Space
4. OBSTRUCTED HIGH Side Reach. If the side reach is over
an obstruction 10 inches or less, mounting height shall
be a maximum of 48 inches (1.21 m) above the floor or
ground to the operable controls. If the side reach
is over an obstruction greater than 10 inches,
but less than 24 inches, mounting height shall
be a maximum of 46 inches (1.17 m) above the
floor or ground to the operable controls.
Maximum
Height
10” or Less
48
34”
Maximum
Height
46”
34”
Greater than 10”
Less than 24”
2. OBSTRUCTED HIGH Forward Reach. If the high forward
reach is over an obstruction, reach and clearances shall
be as shown. NOTE: If the height of a control is 48"
maximum, then the length of the obstruction
must be 20" or less. If the height of a control
is 44" maximum, then the length of the
obstruction may be increased to 25" or less.
48
Maximum
Height
Maximum
Height
25” or Less
44”
20” or Less
5
1835-067 Issued 3-19
Version J
SECTION 1 - INSTALLATION
Prior to installing the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in
this manual. This will help insure that you installation is performed in an efficient and professional manner.
Order your telephone line to be installed at least two weeks prior to the planned telephone entry system installation date. This will assure
that a phone line is available when the unit is installed. The telephone company will require the following information from you:
There are different ways to mount the 1835/1837 (On a wall, in a wall, attached to a architectural style post, kiosk, etc). They need a telephone
line, power and communication wires run to them in conduit or inside a architectural style post. Feed all of the wires through the back or
bottom of the entry system using the existing knock-outs provided in the enclosures. DO NOT make any new holes in the enclosure to feed
wires through. Keep ALL the entry system’s wires away from any existing high voltage power wires a minimum of 6” to help prevent any noise
and hum pickup in the system’s phone line. The system MUST also be properly grounded to function correctly.
WARNING If this telephone entry system is used to control a vehicular gate with an automatic gate operator, the telephone entry system
must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that the user cannot come into
contact with the gate or gate operator when using this entry system.
The telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during
installation. Discharge any static prior to removing the circuit board by touching a proper ground device. GREAT care must be taken after
removing the components from the enclosure to protect them throughout the installation. Carelessness on your part is NOT covered under
warranty.
Make sure ALL dirt, metal or wood debris is removed from inside the enclosure after mounting it. A through cleaning of the enclosure is
needed before re-installing the components back into the system and wiring it. Any debris left inside could damage the control board and
cause the telephone entry system to malfunction during operation.
Caller ID: You may want to order caller ID blocking from the telephone company for the entry system phone line. Without caller ID blocking,
residents with the proper phone equipment WILL BE ABLE to identify the telephone number that the telephone entry system is installed on.
This may or MAY NOT be desirable.
Call Waiting: Residents may order call waiting from their local telephone company AFTER the system has been installed. They can avoid
missing calls coming from the telephone entry system while they are using their phone (No busy signal).
1.1 General Installation
Type: Touch Tone, Loop Start
Ringer Equivalence: 0.0 A
Jack Type: RJ11C
FCC Registration (US): DUF6VT-12874-OT-T
DOC (Canada): 1736 4528 A
On a Architectural
Style Post
(Optional Hood Shown)
On an Outside Wall
On an Inside Wall
In a Lighted Kiosk
(Optional Flush
Mount Kit Shown)
DoorKing Self-Standing
Lighted Kiosk,
(Optional Flush
Mount Kit Required)
Included with the system is an extra random keyed cabinet lock. If desired, for added security against unauthorized entry into the system,
the standard lock may be replaced with the random lock. Note: DoorKing cannot replace this specific lock or keys if lost.
7
8
9
0
4
5
6
1
2
3
C
A
L
L
Z
A
7
8
9
0
4
5
6
1
2
3
C
A
L
L
Z
A
7
8
9
0
4
5
6
1
2
3
CA
L
L
Z
A
7
8
9
0
4
5
6
1
2
3
C
A
L
L
Z
A
6
1835-067 Issued 3-19
Version J
1
6AC1
6AC
BAT
1
N
O
1
N
C
1
C
2
RY
2
C
AZ
I
MC
5
V
D
C
IMD
SPK
R
C
O
M
MI
C
PSW
C
GN
D
PH
ON
E
P
1
P
2
Display
Ribbon
Cable
Circuit Board Screw
Main Terminal Screw
Keypad Ribbon
Cable
Ground
Wire
ACT
DOORK
I
N
G
1491
-
010
BA
CKLIT
E
CU
T
OFF
CONTRA
ST
8 LINE
DISPLAY
DOORKING 1892-010
S
IN
GLE
LINE
D
IS
PLAY
Enclosure
Faceplate
Main Termina
l
Discharge any static
BEFORE removing
the circuit board by
touching a proper
ground device.
Faceplate Hinge Locknuts
1. Disconnect the two ribbon cables from the circuit board.
2. Remove the two screws from the upper corners of the circuit board.
3. GENTLY remove the circuit board by pulling it out of the main terminal.
4. Remove the two screws from the main terminal and remove the
ground wire locknut.
5. Remove five (5) locknuts from the faceplate hinge.
6. Remove the faceplate, main terminal (still wired), ribbon cables and
the circuit board, store them in a Safe Place until they need to be
re-installed.
1.2 Remove Components from Enclosure
7
1835-067 Issued 3-19
Version J
1.3 Enclosure Dimensions
Enclosure can be mounted directly to a wall, pilaster, post mounted using a OPTIONAL DoorKing architectural style mounting
post or recessed in a wall (OPTIONAL Flush Mount Kit). The OPTIONAL Hood can be mounted to enclosure if desired. Be sure
the unit is mounted securely and is not subject to vibration from closing doors or gates.
14.75”
3.75”
12.75”
WARNING! If this entry
system is used to control
a vehicular gate with an
automatic gate operator,
the entry system must be
mounted a minimum of
six (6) feet away from the
gate and gate operator, or
in such a way that a
person cannot operate the
entry system and touch
the gate or gate operator
at the same time.
OPTIONAL Flush Mount Kit (P/N 1814-200)
OPTIONAL Hood (Stainless Steel P/N 1814-180, Black P/N 1814-185)
Back View
Bottom View
3.375” 3”
10.125”
10.125”
1.125”
1.5”
1.5”
10.875”
10.875”
1.875”
1.875”
9”
9”
1.125” Dia
1.375” Dia
6”3.375” 3.375”
Trim RingRough-In Box
Rough-In
Box
Trim Ring
Enclosure
Hood
13.61”
15.34”
17.27” 13.08
13.08
14.88
3.75” 3.76”
15.56”
5.61”
8
1835-067 Issued 3-19
Version J
1. Mount the enclosure using the mounting holes provided in the
corners (see next page for OPTIONAL flush mount kit OR hood
dimensions). Be sure that mounting screws (Not supplied) do not
protrude into the enclosure where they could cause a short on the
back of the circuit board. Make any necessary conduit connections
through the back or bottom of the enclosure using the existing
conduit knock-outs. DO NOT make any new conduit holes in the
enclosure.
2. Route all wiring through conduit or architectural post (not
supplied) into enclosure.
3. Clean out the enclosure. Make sure that all dirt, metal and/or
wood debris is removed.
4. Re-install components back into the enclosure (Reverse section
1.2 steps). Use the wiring schematics in the back of this manual to
help re-install the components if necessary. DO NOT apply any
power at this time.
The illustrations below and next page show typical installations but specific
installations can vary from this. See previous page for dimensions.
Use hardware supplied with
architectural post to secure
enclosure to post.
The hood (sold separately) fits
between the enclosure and the
surface it’s being mounted on if
desired.
Note: The hood CANNOT be
used with the flush mount kit.
Use appropriate
hardware to secure
enclosure to the wall
(not supplied).
Mount
ON
a Surface
Mount
IN
a Surface
(OPTIONAL Flush Mount Kit Required).
Mount to a DKS
Architectural
Post
Mount OPTIONAL
Hood
Mount the rough-in box in the wall and trim
ring will fit inside of rough-in box.
Note: The hood CANNOT be used with the
flush mount kit.
Mount OPTIONAL
Flush Mount Kit
Examples of conduit runs that may be used, depending on how you choose to run
the wiring. Some installations will allow the conduit to be run outside the wall and
connect to the bottom of the enclosure but this is generally NOT recommended.
Run all wires
inside post.
Conduit run
to junction box
Conduit
sweep run
Wall
Rough-In
B
ox
T
rim
Ring
Mounting Screws
(Not supplied
)
Wall
1.4 Install Enclosure
Enclosure
Locknut
Knock-outs
Enc
losure
Mounting
Hole
Knock-ou
ts
M
ou
nting Screw
s
(Not supplied)
Knock-out
E
nclosure
Mounting Ho
le
OPTIONAL
Hood
Continued on next page.
9
1835-067 Issued 3-19
Version J
Mount OPTIONAL DKS Self-Standing Lighted Kiosk
10”
18.5”
60”
The flush mount kit (Sold separately) is installed into the self-standing
kiosk (P/N 1200-???) to secure entry system in place.
Secure the rough-in box in the kiosk. Run all necessary wires to rough-in
box. Slide the trim ring into the rough-in box. Slide the enclosure in the
trim ring and secure them all together with hardware included in the kit.
Rough-In
Box
Trim
Ring
WARNING! If this entry
system is used to control
a vehicular gate with an
automatic gate operator, the
entry system must be
mounted a minimum of six
(6) feet away from the gate
and gate operator, or in
such a way that a person
cannot operate the entry
system and touch the gate
or gate operator at the same
time.
Enclosure
Locknut
Kno
ck-o
u
t
s
10
1835-067 Issued 3-19
Version J
1.5 Memory Chip Replacement
The 1830 entry system is shipped with the memory chip already installed in the unit. However, if you need to
replace the memory chip in the NEW 1830 entry system, follow the instructions below.
CAUTION
NC
NO
NO
RING
NC C
ON
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
12345 67891011121314
1
2
3
MIC
VOL
OFF
KEYPAD
321
321
321
MASTER
CODE
16AC16ACBAT1NO1NC1C2RY2CAZIMC
5VDCIMDSPKRCOMMICPSWCGNDPHONE
TONE ON
TONE OFF
BACKLITE
CUTOFF
CONTRAST
8 LINE
DISPLAY
DOORKING 1892-010
321
SINGLE
LINE
DISPLAY
Note: Be sure that the
memory chip is seated
correctly in the chip holder.
ACT LED Note: LED will flash
when 1830 is programming or
accessing memory chip data.
Remove OLD memory
chip and discard it
Install NEW
memory chip
P/N 1830-404
(DO NOT use P/N 1830-403)
Release
Old Chip
Locked
ACT
New
Arrow MUST be
pointing UP!
Chip Holder
Chip Holder
DO NOT install the memory chip with power to the telephone entry system turned ON. Attempting to install the memory
chip with power on will irrevocably damage the chip. The memory chip is a static sensitive component. Discharge any static
electricity from your hands by touching a proper ground device before touching the control board. Handle the memory chip
with care, the pins can bend easily.
DO NOT install the memory chip UPSIDE-DOWN (Arrow MUST point UP). Installing chip upside-down will cause permanent
damage to the chip.
1835, 1837 Circuit Board
11
1835-067 Issued 3-19
Version J
IMC
5VDCIMDSPKRCOMMICPSWCGNDPHONE
1.6 Postal Lock Installation
At some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they can
deliver the mail. Mail carrier access will be provided by the installation of an Arrow Postal Lock. This is the same lock that the
Post Office uses for gang mailboxes. These locks are not available to the public. The installer or the building owner/manager
will have to call the Post Office and arrange for the installation of this lock into the telephone entry system. All DoorKing
commercial telephone entry systems are designed to accept installation of the postal lock.
Prior to installation of the postal lock, be sure power to the telephone entry system is turned OFF.
1. Remove the hole plug on the faceplate of the telephone entry system.
2. Cut the wire tie wrapped around the switch ONLY when installing postal lock.
3. Remove the two hex nuts from the postal lock-mounting studs. Mount postal lock on the studs and secure with the hex nuts.
When the lock is installed, the pawl of the lock, in the extended position is depressing the switch. When the mail carrier inserts
his key and turns the postal lock, the pawl is withdrawn into the lock and the switch will activate the relay for the programmed
strike time, that has been programmed for this feature.
Factory default settings for the Postal Lock Switch: After the key has been turned, Relay 1 will activate (section 3.3.4) for One
(1) second of strike time (section 3.3.1). The switch input feature (section 3.2.7) is factory set to “activate a relay” and not “dial
a phone number”.
Nylon Hex
Nuts
(Existing)
Existing postal
lock-mounting studs
located inside the faceplate
of the telephone entry system.
Prewired
Postal Lock
Switch
Pawl
NC
Blue
Wire
White
Wire
Co
m
Extended Pawl
Com
NC
Withdrawn Pawl
Com
NC
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
1835
Lock
Position
1837
Lock
Position
Switch
Switch
Main Terminal
Relay Activates
12
1835-067 Issued 3-19
Version J
The tamper switch needs to be connected to a security device or existing security system to comply with the UL 294 standard.
Connect the 2 white wires of the Normally Closed gravity activated dry contact tamper switch to whatever security setup you
desire. The gravity switch gets activated when the faceplate is opened. Repair and maintenance technicians may need to notify
the proper authorities BEFORE opening the entry system faceplate, depending on how your security of this system has been
setup.
Tamper
Switch
Gravity Activated
(Dry Contact)
White
White
Possible Security Connections
Security
Camera
Local
Alarm
System
Separate
Alarm
Power
Siren
Warning
Light
Separate
Siren
Power
Separate
Light
Power
Separate
Camera
Power
Existing
Building Alarm
System
Note: To comply with UL 294 Standard for Safety, the
tamper switch provided in this access control equipment
must be set to activate an alarm or alarm signal when
tripped. If the tamper switch is NOT connected to activate an
alarm or alarm signal, this will void UL 294 certification.
1.7 UL 294 Compliant Tamper Switch
AC
T
DOOR
K
IN
G
149
1-01
0
BAC
KLI
TE
CUTOFF
C
ON
TRAST
8 LINE
D
IS
P
LA
Y
DOORKING 1892-010
SI
N
GL
E
LINE
DISPLAY
16
AC
16AC
BA
T
1N
O
1N
C
1
C
2
RY2C
A
Z
I
M
C
5
V
DC
IM
D
S
P
KR
CO
M
M
IC
PSW
CGND
PHONE
P
1
P2
13
1835-067 Issued 3-19
Version J
P2
12345 67891011121314
16AC16ACBAT1NO
13-Black
12-White
11-Green
14-Red
Black
White
Blue
Yellow
Green
Red
Not used
9-Black
8-White
7-Green
10-Red
#7 thru #10 will activate Relay 2
for its programmed strike time.
#11 thru #14 will activate Relay 1
for its programmed strike time.
Install a OPTIONAL card reader as shown.
Remove and discard plate
from camera.
1.9 OPTIONAL Camera Kit Installation
P
1
P2
+
-
BNC
Connector
CCTV Circuit
Board
Plastic
Spacer
Discard
existing
screw.
Discard
existing
screw.
Plastic
Spacer
Camera
3-Pin
Camera
Plug
4-Pin
Camera
Plug
Top
Power
Terminal
Lighted Keypad
Faceplate
Inside
Faceplate
Remove
Plug from
faceplate
Existing Studs
Mount camera on existing studs
on the inside of the faceplate after
removing plate from camera.
Remove support bar from logo plate.
Card reader slides on existing stud
and is secured with support bar.
Mount CCTV circuit board on back
of lighted keypad as shown. Use
longer screws that comes with kit.
16 AWG - 200 Ft
18 AWG - 100 Ft
Power Wire Run
Wire not supplied
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
1835 Camera Position
1837 Camera Position
1.8 OPTIONAL Internal Card Reader Installation
Support Bar
Log
o Plate
Important: DO NOT power the
camera with the telephone entry
system’s 16.5 VAC 20 VA power
transformers.
Note: Transformer
is for indoor use
and MUST be in a
protected enclosure
from weather when
using outdoors.
Internal Card Readers:
DoorKing DK Prox - P/N 1815-302
HID Prox Point Plus - P/N 1815-380
ID-Teck RF Tiny - P/N 1815-215
RG-59U Coax (Not supplied)
500 ft. max.
To Monitor, Video Recorder
CCTV Circuit Board Connections
To BNC
Connector
UTP wire
1400 ft. max.
To Monitor,
Video Recorder
DoorKing offers video adapters (Not supplied) for up to 1400 ft
using unshielded twisted pair telephone wire. (P/N 1812-039)
VTT-2000
Video
Adapter
(At Monitor,
Video
Recorder)
VTT-2000
Video
Adapter
(At 1830)
Install a OPTIONAL camera kit as shown (P/N 1812-147).
Camera
Harness
12 VDC
Polarity Matters!
Black (-)
Red (+)
14
1835-067 Issued 3-19
Version J
Install OPTIONAL heater as shown (P/N 2600-584). For cold weather climates where temperatures routinely drop below 40°F
(4°C). The thermostat will automatically control the temperature inside operator housing.
1.10 OPTIONAL Heater Installation
ACT
D
OOR
K
IN
G
149
1-
010
BACKLI
TE
CUT
OFF
C
ONTRAS
T
8
LI
NE
D
I
SPLAY
DOORKING 1892-010
SI
N
G
LE
LINE
DISPLA
Y
16A
C
1
6
AC
B
A
T
1N
O
1N
C1C2
RY
2
CA
Z
I
M
C
5VDCI
M
DS
P
KR
COM
M
IC
PSW
CGND
PHONE
P1
P2
HOT
Important: DO NOT power the
heater with the telephone entry
system’s 16.5 VAC 20 VA power
transformers.
12 VAC
40 VA
Output
Wire polarity
does not matter
Attach the heater in the center of
the faceplate. Built-in magnets
will secure heater in place.
The heater gets VERY HOT, DO NOT allow
existing components or wires to come in
contact with the metal heater housing.
Faceplate
Attach the thermostat on the bottom inside of the
cabinet as far from heater as possible. DO NOT
position the thermostat right next to the heater.
Built-in magnets will secure thermostat in place.
Thermostat will automatically turn heater on at
approximately 40°F (4°C) and off at 55°F (12°C).
Note: Transformer is for indoor use
and MUST be in a protected enclosure
from weather when using outdoors.
Up to 100 feet, use 18 AWG - 600 volt insulated wire.
Up to 200 feet, use 16 AWG - 600 volt insulated wire.
DO NOT run heater power wires over 200 feet or use
smaller wire than specified. Route wires to avoid
contact with the resistors on the telephone entry
system control board.
15
1835-067 Issued 3-19
Version J
Low Voltage/
Communication
Wire Conduit
High Voltage
Power Wire
(115 V) Conduit
Electrical field from high voltage wires.
6” minimum
Underground Cutaway
SECTION 2 - WIRING
Be sure that you use proper wire that has an insulation
rated for an underground environment. All wires
should be placed in conduits. Proper pre-planning can
greatly ease the installation and wiring of this system.
Always check with the local building code to determine
the type of wire required in your municipality.
DO NOT run high voltage (115 V) power lines and low voltage/communication lines in the same conduit. These should be in
separate conduits at least six (6) inches apart. Be sure that all phone line wiring is twisted and completely isolated from ground.
Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the instructions, illustrations,
and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional
manner.
The wiring of the telephone entry panel is an extremely important and integral part of the overall access control system. Use
proper wire for the communication line, power wires, and be sure that the system is properly grounded. Check all local building
ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes.
Telcom Access Standards. It is not permissible for customers to use the telcom network lead-in cable to provide the intercom
function between the gate and the house. New Zealand Customers: All door and gate entry systems wiring must comply with
PTC106: March 2008, Section 9.
WARNING If this telephone entry system is used to control a vehicular gate with an automatic gate operator, the telephone
entry system must be mounted a minimum of six (6) feet away from the gate and gate operator, or in such a way that the
user cannot come into contact with the gate or gate operator when using this entry system. If this unit has been installed
closer to the automated vehicular gate, do not proceed with any wiring until the unit has been moved and re-installed so
that it is in compliance with these instructions.
This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static
discharges during installation or use. Discharge any static prior to removing the circuit board from the enclosure by touching
a proper ground device.
Use only the two (2) supplied transformers (or UL listed equivalent) to power the telephone entry and access control system
and any 26, 30 and 31 Bit wiegand input devices that use 16.5 VAC, 20 VA. DO NOT power any other devices (expansion
boards, electric strikes, magnetic locks etc.) from these power transformers.
Note: Transformers are not supplied on units sold outside the United States. An Inherently Protected Transformer must be used
to power this device. Use only transformers that are listed by a recognized testing laboratory to power the telephone entry
system.
Wiegand wire runs are 500-feet maximum. Use
6-conductor stranded wire with overall shield. 18, 20,
22 or 24 gauge is sufficient for these connections.
“Optional” 12 volt .8 amp hour gel-cell batteries (DoorKing P/N 1801-008) can be installed to provide stand-by power in the
event of a power outage. Two batteries are required, one for the system power and one for the auxiliary terminal power.
500 ft Max
26, 30, 31-Bit
Wiegand Device
2.1 Wiring Guidelines
2.1.1 Power
2.1.2 Wire Runs
Up to 100 feet, use 18 AWG, 600 volt insulated wire.
Up to 200 feet, use 16 AWG, 600 volt insulated wire.
The importance of proper AWG power wiring cannot be over stressed!
Wire polarity does not matter
Power wires are susceptible to noise and hum pickup; therefore
it is preferable that you keep power wire runs as short as possible.
Two 16.5 VAC, 20 VA for 1835.
One 16.5 VAC, 20 VA and
One 16.5 VAC, 40 VA for 1837.
Do Not Connect To A
Receptacle Controlled
By A Switch.
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
PERMANENT WIRING MUST BE EMPLOYED AS REQUIRED BY LOCAL
ELECTRICAL CODES. ALWAYS ADHERE TO THE LOCAL AND NATIONAL
ELECTRICAL CODE SPECIFICATIONS WHEN WIRING THE TELEPHONE ENTRY
SYSTEM/ACCESS CONTROLLER AND OTHER ACCESS CONTROL DEVICES.
16
1835-067 Issued 3-19
Version J
The use of surge suppressors can significantly reduce the chance of component failure because of static charges or surges.
DoorKing recommends Installing a Phone Line surge suppressor (DoorKing P/N 1877-010 or equivalent) and a Low Voltage
surge suppressor (DoorKing P/N 1878-010 or equivalent) to help protect the entry system from power surges.
Proper grounding of this system is a requirement. To be effective, ground connections should be made with a minimum 12
AWG, 600 volt insulated wire to a ground point within 10 feet of the telephone entry system. The ground point must be at an
electrical panel, a metallic cold water pipe that runs in the earth, or a stainless steel grounding rod driven at least ten (10) feet
into the soil. A architectural style mounting post anchored to concrete does NOT make a good ground.
Install on each
16.5 VAC Transformer
Surge suppressor within 3 ft of ground source.
POWER LINE
1878-010
Low voltage surge suppressor
within 10 ft of entry system.
Some Acceptable Ground Sources
Ground to a metallic cold water pipe.
Ground
Wire
Ground
Wire
Ground to an existing electrical system.
Electrical
Panel
Grounding rod 10 feet in soil.
IMPORTANT: Ground wire shown without
safety protection for clarity. Make sure
ground wire is protected from being
touched or electrical shock could occur!
Phone line surge suppressor
within 10 ft of entry system.
Surge suppressor within 3 ft of ground source.
Phone Company
PHONE LINE
1877-010
2.1.3 Grounding
2.1.4 Surge Suppression
2.1.5 Expansion Boards and Elevator Control
2.1.6 Ferrite Filter
I
f Expansion Boards are being used with this system, refer to the Installation and Wiring manual that came with the Expansion
boards, for detailed information on wiring Expansion boards to the PC programmable telephone entry system.
If Elevator Control is used with this system, refer to the Elevator Control Installation and Wiring manual for detailed information
on wiring the elevator control boards to this system and to the elevator push button control panel.
The Telephone Entry System comes with two (2) Ferrite Filters. These will help
prevent noise and hum pickup in the phone lines. One is installed around the 16 VAC
power wires on the main terminal #19 and #20. The second is installed around all the
wires connected to the aux terminal.
To install the ferrite filter, release the
clip on the side to open the filter,
place the wires in the circular core
and snap the filter closed.
Power Wires
on all models
Auxiliary Wires
1
6AC
20
19
18
1
7
16
15
14
1
6AC
Main Terminal
Aux Terminal
BA
T
1
N
O
1N
C
2RY
2C
14
12
13
11
10
9
8
7
6
5
4
3
2
1
Clip Release
Clip Release
#1
#2
Phone Line Surge Suppressor
Low Voltage Surge Suppressor
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
0
4 5 6
1 2 3
7 8 9
CALL
Z
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

DKS 1835/37 90 Series User manual

Category
Security access control systems
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI