ASSEMBLY, USAGE & MAINTENANCE
DISASSEMBLING & INSTALLING NEW CANISTER FILTER
Remove top handle & top plate
1. The top handle (A) Fig.1 must be removed, loosen hex. bolt (B) and slide the
top handle off the shaft.
2. The top plate (C) Fig.1 must be removed, remove the 6 hex. bolts (D) that
secure it to the Cyclone Dust Collector. Slide top plate off the shaft.
Unbolting used canister filter
1. From inside the upper housing, remove the 6 hex. bolts (A) Fig.2 to detach
canister filter from the Cyclone Dust Collector housing.
Removing handle shaft
1. The handle shaft (A) Fig.3 must be removed from the canister filter. Loosen
cap screws (B) and remove handle shaft.
Installing canister filter to Cyclone Dust Collector housing
1. Install handle shaft (A) Fig. 3 on new canister filter shaft, tighten cap screws
(B). Make sure one cap screw is tightened against the flat of the canister filter
shaft.
2. Position the new canister filter under the housing and secure it using the 6 hex.
bolts (A) Fig.2 removed previously. Obtaining help from a second person is
recommended.
3. Reinstall the top plate (C) Fig.1 using the 6 hex. bolts (D).
4. Reinstall the top handle (A) Fig.1, and tighten hex. bolt (B) on the flat portion
of the shaft.
5. Secure the canister filter dust bag to the bottom of the canister filter using the
retaining strap supplied with the Cyclone Dust Collector.
USAGE/MAINTENANCE
After considerable use, there will be dust build-up in the filter which will reduce
long term efficiency. The top handle (A) Fig.1 is used to dislodge dust build-up in
the filter. Turning the top handle rotates rubber flaps which disloge dust and
increase long term efficiency. Periodically clean the filter with compressed air.
PARTS DIAGRAM & PARTS LISTS
Refer to the Parts section of the King Canada web site for the most updated parts diagram and parts list.
FIGURE1
FIGURE2
FIGURE3