SOLENOID VALVE RETROFIT KIT NUMBERS
84571 84572 84575 84574
86606 86644 86650
600
1. REMOVE EXISTING SOLENOID (See figs. 1 and 2)
a. Disconnect brewer from electric power and shut off water
supply.
For brewers with faucet, open faucet to bleed off water
pressure.
b. Remove TOP PANEL, FRONT PANEL and SOLENOID
ACCESS DOOR.
c. Disconnect wires to solenoid.
Remove silicone SUPPLY HOSE from solenoid.
d. For brewers with faucet, disconnect FAUCET SUPPLY
TUBE from solenoid and faucet shut-off valve.
Discard this tube.
e. Remove BRASS NUT from INLET FITTING.
Lift solenoid / timer / bracket assembly from mounting clip.
f. Loosen screws on bottom of solenoid and separate solenoid
from bracket.
Remove solenoid and fittings from cabinet.
Reinstall bracket on mounting clip.
CAUTION:
ELECTRIC SHOCK
HAZARD
Unplug brewer before beginning
conversion.
Fig. 1
NOTE: TYPICAL INSTALLATION
SHOWN. ALL INSTALLATIONS ARE
SIMILAR. DETAILS MAY VARY.
Fig. 2
REMOVE SHADED COMPONENTS
* SOLENOID ACCESS DOOR
* SOLENOID AND FLOW CONTROL
* INLET FITTING, TEE & ADAPTERS
p/n 75909 Rev. A ECN-13394
I
600 080211 cps
1 of 3
FAUCET
SUPPLY TUBE
SOLENOID
ASSEMBLY
ACCESS
DOOR
DISCONNECT
TIMER
BRACKET
ACCESS DOOR
SILICONE SUPPLY HOSE
FAUCET SUPPLY TUBE
DISCONNECT