  • Hello! I am an AI chatbot trained to assist you with the Husky H4640 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
6
Operation
1
Operating the air saw
This Air Saw is designed to operate on 90 PSIG. Lower
pressure (below 90 PSIG) will reduce performance of
the tool. Higher air pressure (over 90 PSIG) raises the
performance of the tool beyond its rated capacity and
could cause serious damage to the tool and the user.
2
Installing the saw blade
WARNING: Disconnect the tool from the air supply before
servicing or changing accessories.
Insert hex key (C) into set scew and rotate counter
clockwise to loosen. Insert saw blade (B) into the blade
holder assumbly.
Push saw blade (B) in comletely until it stops. Tighten set
screw with hex key (C) by turning the hex key counter
clockwise. Be sure to snap down to avoid coming loose
during opertion.
3
Removing the saw blade
Insert hex key (C) into set scew and rotate counter
clockwise to loosen and remove saw blade (B).
4
Cutting objects
WARNING: The blade guide must be against the object
while cutting.
Place the cutting edge of the saw guard against the work
piece and then press the trigger.
(C)