Haier AU342XHERA Installation guide

Category
Split-system air conditioners
Type
Installation guide

This manual is also suitable for

No. 0150501212 B
Please read this manual carefully before using this air conditioner
Please keep this manual safely for future use
OUTDOOR UNIT
INVERTER
INSTALLATION MANUAL
EN
MANUALE DI INSTALLAZIONE
IT
MANUEL D’INSTALLATION
FR
INSTALLATIONSANLEITUNG
DE
MANUAL DE INSTALACIÓN
ES
R410A X-MULTI INVERTER
AU182XFERA
AU222XFERA
AU252XGERA
AU282XHERA
AU342XHERA
AU362XHERA
AU182XFERA AU222XFERA AU252XGERA AU282XHERA AU342XHERA AU362XHERA
CE
Tutti i prodotti sono conformi alle seguenti normative europee:
- Direttiva 73/23/EEC Basso Voltaggio
- Direttiva 2006/95/EC Basso Voltaggio
- Direttiva 89/336/EEC Compatibilità elettromagnetica
ROHS
Il prodotto è conforme alla normativa 2002/95/EEC sulla restrizione d’uso di
sostanze inquinanti negli apparecchi elettrici ed elettronici.
WEEE
Informativa al consumatore come previsto dalla normativa europea
2002/96/CE riguardante i rifiuti di apparecchiature elettriche ed elettroniche.
SPECIFICHE DI SMALTIMENTO:
Il climatizzatore è contrassegnato con questo simbolo,
ciò significa che i prodotti elettrici ed elettronici non
possono essere smaltiti insieme ai rifiuti domestici non
differenziati. Non cercare di demolire il sistema da soli:
la demolizioni dei sistemi di condizionamento, nonché il
recupero del refrigerante, dell’olio e di qualsiasi altra
parte devono essere eseguiti da un installatore qualifi-
cato in conformità alla legislazione locale e nazionale
vigente in materia.I climatizzatori devo essere trattati presso una struttura spe-
cializzata nel riutilizzo, riciclaggio e recupero dei materiali. Il corretto smaltimen-
to del prodotto eviterà le possibili conseguenze negative all’ambiente e alla
salute dell’uomo. Per maggiori informazioni contattare l’installatore o le autori-
tà locali. Le batterie devono essere tolte dal telecomando e smaltite separata-
mente conformemente alla legislazione locale e nazionale vigente in materia.
CONFORMITÀ ALLE DIRETTIVE EUROPEE PER I MODELLI:
Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China
IT
AU182XFERA AU222XFERA AU252XGERA AU282XHERA AU342XHERA AU362XHERA
CE
All the products are in conformity with the following European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
- Electromagnetic CompatibilitY 89/336/EEC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the
European parliament and of the council on the Restriction of the use of Certain Haz-
ardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
.
WEEE
In accordance with the directive 2002/96/CE of the European parliament,
herewith we inform the consumer about the disposal requirements of the
electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this sym-
bol. This means that electrical and electronic products
shall not be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dis-
mantling of the air conditioning system, treatment of
the refrigerant, of oil and of other part must be done
by a qualified installer in accordance with relevant
local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed of correctly, you
will help to prevent potential negative consequences for the environment and
human health. Please contact the installer or local authority for more infor-
mation. Battery must be removed from the remote controller and disposed of
separately in accordance with relevant local and national legislation.
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS:
EN
AU182XFERA AU222XFERA AU252XGERA AU282XHERA AU342XHERA AU362XHERA
CE
Tous les produits sont conformes aux directives européennes suivantes:
- Directive 73/23/CEE Basse tension
- Directive 2006/95/CE Basse tension
- Directive 89/336/CEE Compatibilité électromagnétique
ROHS
L'appareil est conforme à la directive 2002/95/CEE relative à la limitation de
l'utilisation de certains substances dangereuses dans les équipements élec-
triques et électroniques.
DEEE (WEEE)
Information au consommateur comme le prévoit la directive européenne
2002/96/CE relative aux déchets d'équipements électriques et électro-
niques.
SPECIFICATIONS POUR L'ELIMINATION:
Ce pictogramme, apposé sur le climatiseur, signifie
que les équipements électriques et électroniques ne
peuvent pas être éliminés avec les déchets ménagers
non triés. Ne pas essayer de démanteler l'équipement
soi-même: le démantèlement des systèmes de clima-
tisation, ainsi que la récupération du frigorigène, de
l'huile et de toute autre partie doivent être effectués
par un installateur qualifié conformément à la législa-
tion locale et nationale en vigueur en la matière. Les climatiseurs doivent être
traités dans un centre spécialisé dans la réutilisation, le recyclage et la valo-
risation des matériaux. L'élimination correcte de ces appareils permet d'évi-
ter les effets nocifs sur l'environnement et la santé humaine. Pour plus de
renseignements contacter l'installateur ou les autorités locales. Les piles doi-
vent être retirées de la télécommande et éliminées séparément, conformé-
ment à la législation locale et nationale en vigueur en la matière.
CONFORMITÉ AUX DIRECTIVES EUROPÉENNES POUR LES MODÈLES:
FR
Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel Protocollo
di Kyoto. Non liberare tali gas nell’atmosfera.
Tipo di refrigerante: R410A
Valore GWP*: 1975
*
GWP = potenziale di riscaldamento globale
Compilare con inchiostro indelebile,
• 1 la carica di refrigerante di fabbrica del prodotto
• 2 la quantità di refrigerante aggiuntiva nel campo e
• 1+2 la carica di refrigerante totale
sull’etichetta di carica del refrigerante fornita con il prodotto
L’etichetta compilata deve essere collocata in prossimità della portata di cari-
ca del prodotto (ad esempio, nell’interno del coperchio della valvola d’inter-
cettazione).
A contiene gas fluorurati ad effetto serra inclusi nel protocollo di Kyoto
B carica di refrigerante di fabbrica del prodotto: vedi targhetta con il nome
dell’unità
C quantità di refrigerante aggiuntiva nel campo
D carica di refrigerante totale
E unità esterna
F cilindro del refrigerante e collettore di carica
INFORMAZIONI IMPORTANTI SUL REFRIGERANTE UTILIZZATO
Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China
1
1+2=
kg
R410A
2
kg
2=
1=
B
C
D
FE
kg
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
A
This product contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Do not vent into the atmosphere.
Refrigerant type: R410A
GWP* value: 1975
*
GWP = global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging
port (e.g. onto the inside of the stop valve cover).
A contains fluorinated greenhouse gases covered by the Kyoto Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
IT
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
EN
Ce produit contient des gaz à effet de serre fluorés encadrés par le protoco-
le de Kyoto. Ne pas laisser les gaz s’échapper dans l’atmosphère.
Type de réfrigérant: R410A
Valeur GWP*: 1975
*
GWP = potentiel de réchauffement global
Prière de compléter à l’encre indélébile,
• 1 la charge de réfrigérant d’usine du produit
• 2 la quantité de réfrigérant supplémentaire chargée sur place et
• 1+2 la charge de réfrigérant totale
sur l’étiquette de charge de réfrigérant fournie avec le produit.
L’étiquette complétée doit être apposée à proximité de l’orifice de recharge
du produit (par ex. à l’intérieur du couvercle de la vanne d’arrêt).
A contient des gaz à effet de serre fluorés encadrés par le protocole de
Kyoto
B charge de réfrigérant d’usine du produit: voir plaquette signalétique de
l’unité
C quantité de réfrigérant supplémentaire chargée sur place
D charge de réfrigérant totale
E unité extérieure
F cylindre de réfrigérant et collecteur de recharge
INFORMATION IMPORTANTE RELATIVE AU RÉFRIGÉRANT UTILISÉ
FR
OUTDOOR UNIT
INSTALLATION MANUAL
AU182XFERA
AU222XFERA
AU252XGERA
AU282XHERA
AU342XHERA
AU362XHERA
Please read this manual carefully before installing the units.
Please keep this manual safely for future use.
R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER
Contents
Unit appearance
Cautions
Safety precautions
Installation instructions
Installation drawings of indoor and outdoor units
Matching of the indoor and outdoor units
Installation procedure
Purging method: to use vacuum pump
Wiring work
Test running & Items to confirm
Trouble shooting
1
2-3
4
5-6
7
8-13
14-17
18
19-22
23
24
Unit appearance
AU252XGERAAU182XFERA
AU222XFERA
AU282XHERA
AU342XHERA
AU362XHERA
1
Cautions
2
Disposal of the old air conditioner
Before disposing an old air conditioner that goes
out of use, please make sure it's inoperative and
safe. Unplug the air conditioner in order to avoid
the risk of child entrapment.
It must be noticed that air conditioner system
contains refrigerants, which require specialized
waste disposal. The valuable materials contained
in a air conditioner can be recycled. Contact your
local waste disposal center for proper disposal of
an old air conditioner and contact your local
authority or your dealer if you have any question.
Please ensure that the pipework of your air
conditioner does not get damaged prior to being
picked up by the relevant waste disposal center,
and contribute to environmental awareness by
insisting on an appropriate, anti-pollution method
of disposal.
Disposal of the packaging of your new air
conditioner
All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the environment.
The cardboard box may be broken or cut into
smaller pieces and given to a waste paper disposal
service. The wrapping bag made of polyethylene
and the polyethylene foam pads contain no
fluorochloric hydrocarbon.
Consult your local authorities for the name and
address of the waste materials collecting centers and
waste paper disposal services nearest to your house.
All these valuable materials may be taken to a
waste collecting center and used again after
adequate recycling.
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide carefully.
The User's Guide contains very important
observations relating to the assembly, operation
and maintenance of the air conditioner.
The manufacturer does not accept responsibility
for any damages that may arise due to non-
observation of the following instruction.
Damaged air conditioners are not to be put into
operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in
strict compliance with the relative instructions set
forth in the User's Guide.
Installation shall be done by professional people,
don't install unit by yourself.
For the purpose of safety, the air conditioner
must be properly grounded in accordance with
specifications.
Always remember to unplug the air conditioner
before opening inlet grill. Never unplug your air
conditioner by pulling on the power cord. Always
grip plug firmly and pull straight out from the
outlet.
Cautions
3. If the fuse on PC board is broken please change
it with the type of T 3.15A /250VAC or T
25A/250VAC.
Please check the circuit diagram about the fuse
replaced.
4. The wiring method should be in line with the
local wiring standard.
5. The power cable and connecting cable are self-
provided. All the cables shall have got the local
authentication certificate. During installation, when
the connecting cables break off, it must be assured
that the grounding wire is the last one to be broken
off.
6. The breaker of the air conditioner should be all-
pole switch; and the distance between its two
contacts should be no less 3mm. Such means for
disconnection must be incorporation in the fixed
wiring.
7. The waste battery shall be disposed properly.
All electrical repairs must be carried out by
qualified electricians. Inadequate repairs may result
in a major source of danger for the user of the air
conditoiner.
Do not damage any parts of the air conditioner
that carry refrigerant by piercing or perforating the
air conditioner's tubes with sharp or pointed items,
crushing or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in serious eye
injuries.
Do not obstruct or cover the ventilation grille
of the air conditioner. Do not put fingers or any
other things into the inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be allowed
to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
2. If the supply cord is damaged, it must be replaced
by the manufacturer or its service agentor a similar
qualified person.
3
Cooling
Indoor
Indoor
Maximum:D.B/W.B
Minimum:D.B/W.B
Maximum:D.B
Minimum:D.B
Maximum:D.B
Minimum:D.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Heating
Outdoor
Outdoor
32 C/23 C
18 C/14 C
43 C/26 C
10 C/6 C
27 C
20 C
24 C/18 C
-15 C
Safety precautions
4
All units shall be earthed. The earth must not be connected to a gas pipe, water pipe, or telephone line.
Poor earthing could cause electric shock.
Be sure to install a circuit breaker to avoid electric shock.
Arrange water drainage according to this manual. Cover pipe with insulation materials to prevent
condensation occuring. Improper installation of water drainage will cause water leakage.
Installation work must be carried out by professional qualified people, do not install the unit by yourself.
Incorrect installation will cause water leakage, electric shock and potentially fire.
Install the unit as per the manual. Incorrect installation will cause water leakage, electric shock or
fire risk.
Be sure to use specified accessories and parts. Otherwise, water leakage, electric shock, fire risk or unit
falling down may occur .
Mounting position must be strong enough to hold the unit. Or, the unit will potentially fall down causing
injuries.
When installing the unit, take in consideration storms and high winds. Incorrect installation may cause
the unit to fall down.
All electric work should be carried out by experienced personnel as per current regulations and this
manual. Incorrect installation or undersized electric cable may cause electric shock or fire risk.
All circuits must be earthed. Ensure that no external forces will affect the terminal block and electric
cable. Poor wiring and installation may cause fire risk.
Arrange wire connection between connecting the indoor and outdoor power supply correctly. Fix terminal
cover firmly to avoid overheating, electric shock or even fire risk.
In the case of a refrigerant leakage during unit installation, keep the room well ventilated.
Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce a poisonous gas
subject to heat.
Isolate power supply before touching terminal block.
To ensure proper installation, please read this safety precautions carefully before the installation. After
installation, start the unit correctly and ensure that you show the customer how to operate and maintain
the units.
WARNING!
CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause
serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
To maintain good picture or reduce noise, keep the unit at least 1m from T.V. or radio, when installing
the communication wire and power supply. (If the radio wave is relatively strong, 1m is not enough to
reduce the interference).
Do not install the unit in following places:
(a) Oil mist or oil gas exists, such as kitchen, or, plastic parts may age, or water leakage.
(b) Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion
causing leakage.
(c) Where there is strong radiation. It will affect the unit's control system, causing malfunction of the
unit.
(d) Where there are flammable gas, dirt, and volatile matter (thinner, gasoline) exist, these items will
cause a fire risk.
WARNING
WARNING
Installation instructions
The following accessories are supplied together with the outdoor unit.
AU182XFERA
AU222XFERA
5
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not
disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor.
Place,where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around.(Refer to drawings).
Place, where the distance of more than 1m from televisions, radios, wireless apparatuses and fluorescent
lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when
the fluorescent lamps in the room are lightened.
No.
1
2
3
Quantity
1
4
1
Name of parts
Drainage elbow
Rubber cushion
Clap
Drawing
Installation accessories
Choose the installation place
Installation dimensions(mm)
113.5
583
113.5
Installation instructions
AU252XGERA
AU282XHERA
AU342XHERA
AU362XHERA
6
860
976
115 630
950
1068
340
580 185185
950
1068
340
580
185
185
Installation drawings of indoor and outdoor units
1. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work
without connecting the indoor unit in ordor to add another indoor unit later. Make sure no dirt or mositure
gets into eigher side of the embedded branch piping.
2.It is impossible to connect the indoor unit for one unit only. Be sure to connect at least 2 units.
Installation sketch map is illustrated for
example model AU362XHERA.
7
If there is the danger of
the unit falling or
overturning, fix the unit
with foundation bolts,
or with wire or other means.
If the location does not have good drainage, place the unit on a level mounting base(or a plastic pedestal).
Install the outdoor unit in a level position. Failure to do so may result in water leakage or accumulation.
Arrangement of piping directions
Rear left
Rear right
Right
Below
Left
Attention must be
paid to the rising up
of drain hose
Wrap the insulation pipe with the finishing
tape from bottom to top.
Cut thermal insulation pipe to an
appropriate length and wrap it with tape,
making sure that no gap is left in the
insulation pipe's cut line.
Matching of the indoor and outdoor units
8
WARNING!
Combinations those marked * can not be applied where the temperature in winter is too low and in
summer is too higher to avoid bad heating or cooling effect.
Combination
A B C
Remark
07 12
09 09
09 12
12
12
07 07 07
07 07 09
07 07 12
07 09 09
07 09 12
09 09 09
09 09 12
1:2
1:3
*
*
*
AU182XFERA
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
AU222XFERA
07 14
09 12
09 14
12
12
07 07
09
07
07 12
07
09 09
07 09
12
09 09 09
09 09 12
1:2
1:3
*
*
*
09
12 12
*
Combination
A B C
Remark
Matching of the indoor and outdoor units
9
Remark
07
07
07
09
09
09
12
12
12
14
14
18
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
12
12
07
07
07
07
07
07
07
07
07
07
09
09
A B
12
14
18
12
14
18
12
14
18
14
18
18
07
07
07
07
07
09
09
09
09
12
12
12
09
09
09
09
12
12
12
12
12
07
07
07
07
07
07
07
07
09
09
09
09
C
-
-
-
-
-
-
-
-
-
-
-
-
07
09
12
14
18
09
12
14
18
12
14
18
09
12
14
18
12
14
18
12
14
07
07
07
07
09
09
09
12
09
09
09
09
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
07
09
12
14
09
12
14
12
09
12
09
12
-
-
-
-
-
*
-
*
*
*
*
*
-
-
*
*
*
-
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Combination
1:2
1:3
1:4
AU252XGERA
Matching of the indoor and outdoor units
10
Remark
07
09
12
12
14
14
18
07
07
07
07
07
07
07
09
09
09
09
09
09
12
12
12
12
12
14
07
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
A B
18
18
14
18
14
18
18
07
07
07
09
09
09
09
09
09
09
09
12
12
12
12
12
14
14
14
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
09
09
12
C
-
-
-
-
-
-
-
12
14
18
09
12
14
18
09
12
14
18
12
14
12
14
18
14
18
14
07
07
07
07
07
09
09
09
09
09
09
09
09
09
09
09
12
12
12
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
07
09
12
14
18
09
12
14
18
09
12
14
18
09
12
14
12
14
12
-
-
-
-
-
-
*
-
-
-
-
-
-
*
-
-
-
*
-
*
*
*
*
*
*
*
-
-
-
*
*
-
-
*
*
-
*
*
*
*
*
*
*
*
*
Combination
1:2
1:3
1:4
AU282XHERA
Matching of the indoor and outdoor units
11
AU342XHERA
Remark
12
14
14
18
07
07
07
07
07
09
09
09
09
09
09
12
12
12
12
12
14
14
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
12
A B
18
14
18
18
07
07
09
09
09
09
09
09
09
12
12
12
12
12
14
14
14
14
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
09
09
09
09
09
12
12
C
-
-
-
-
14
18
12
14
18
09
12
14
18
12
14
12
14
18
14
18
14
18
07
07
07
07
09
09
09
09
12
12
14
09
09
09
09
12
12
09
09
09
09
12
12
12
12
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
09
12
14
18
09
12
14
18
12
14
14
09
12
14
18
12
14
09
12
14
18
12
14
12
12
-
-
-
*
-
-
-
-
-
-
-
-
*
-
-
*
*
*
*
*
*
*
-
-
-
*
-
-
*
*
*
*
*
-
*
*
*
*
*
*
*
*
*
*
*
*
*
Combination
1:2
1:3
1:4
Matching of the indoor and outdoor units
12
AU362XHERA
Remark
12
14
14
18
07
07
07
07
07
09
09
09
09
09
09
12
12
12
12
12
14
14
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
12
A B
18
14
18
18
07
07
09
09
09
09
09
09
09
12
12
12
12
12
14
14
14
14
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
09
09
09
09
09
12
12
C
-
-
-
-
14
18
12
14
18
09
12
14
18
12
14
12
14
18
14
18
14
18
07
07
07
07
09
09
09
09
12
12
14
09
09
09
09
12
12
09
09
09
09
12
12
12
12
D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
09
12
14
18
09
12
14
18
12
14
14
09
12
14
18
12
14
09
12
14
18
12
14
12
12
-
-
-
*
-
-
-
-
-
-
-
-
*
-
-
*
*
*
*
*
*
*
-
-
-
*
-
-
*
*
*
*
*
-
*
*
*
*
*
*
*
*
*
*
*
*
*
Combination
1:2
1:3
1:4
Matching of the indoor and outdoor units
Remark
A B C
D
-
-
-
-
-
-
-
*
*
-
*
*
-
-
*
*
-
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Combination
1:5
E
13
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
09
09
12
09
09
09
09
09
09
09
07
07
07
07
07
07
07
07
07
07
07
07
09
09
09
09
09
09
09
12
12
09
09
09
09
09
09
09
12
12
12
09
09
09
09
09
09
12
07
07
07
07
07
09
09
09
09
12
12
12
09
09
09
09
12
12
12
12
12
09
09
09
09
12
12
12
12
12
12
09
09
09
09
12
12
12
07
09
12
14
18
09
12
14
18
12
14
18
09
12
14
18
12
14
18
12
14
09
12
14
18
12
14
18
12
14
12
09
12
14
18
12
14
12
Installation procedure
14
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same
as the corresponded name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable
by cutting it.
2.Selecting a location for installation of the indoor units
The maxinum allowable length of refrigerant piping, and the maxmum allowable height difference
between the outdoor and indoor units, are listed below.
(The shorter the refrigerant piping, the better the performance. Connect so that the piping is as short as
possible. Shortest allowable length per room is 3m)
1.Precautions on installation
Check the strength and level of the installation ground so that unit will not cause any operating vibration
or noise after installation.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts.
It is best to screw in the foundation bolts unit their length are 20 mm from the foundation surface.
Power source
Limitations on the installation
Outdoor unit capacity class
Piping to each indoor unit
Total length of liquid piping
between all units
AU252XGERA AU282XHERA
AU342XHERA AU362XHERA
25m max.
60m max.
AU182XFERA AU222XFERA
25m max.
45m max.
Installation procedure
The piping length information, please refer the following table.
Descriptions Standard
A, B, C, D, E liquid pipe
A, B, C, D,E Gas pipe
mm
Item MaximumUnit
L1 (one way)
L2 (one way)
L3 (one way)
h
H +
H -
mm
m
m
m
m
m
m
Size of the liquid side connection pipe
Drop between every two indoor units
Drop between the outdoor unit and the indoor unit
/
/
Size of the gas side connection pipe
Drop between the outdoor unit and the indoor unit
6.35
9.52
L1+L2+L3+L4+L5 m
Total liquid piping length(It is no need to charge additional
refrigerant within this value)
L4 (one way) m
Conneting pipe length
Conneting pipe length
Conneting pipe length
Conneting pipe length
L5 (one way) m
Conneting pipe length
1
5
5
10
10
10
5
15
10
25
25
25
25
L1
L2
L5
h
H +
A
B
E
C
L3
L4
D
15
10
40
60
10
25
H -
3. Limitations values on the piping work .
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65