INTELLISYS SOFTSHUTTM GATE VALVE MODELS
TSS-OP-LIT 08/11
TABLE 2.3 STANDARD TSS DIMENSION AND WEIGHT SPECIFICATIONS (REFER TO FIGURE 2.1)
VALVE
SIZE
NOM.
ID
TOTAL
STANDARD
WIDTH
“A”
BONNET
LENGTH
“B”
BODY
LENGTH
“C”
BODY
WIDTH
“D”
TOTAL
L-POS.
WIDTH
“L”
TOTAL
T-POS.
HEIGHT
“T”
WEIGHT
LBS (KG)
DN-63 21/210.6 (269) 5.83 (148) 11.38 (289) 4.37 (111) 12 (306) 15.7 (398) 19 (8.6)
DN-80 3 10.7 (272) 6.30 (160) 12.56 (319) 5.04 (128) 12.1 (308) 16.3 (414) 27 (12.3)
DN-100 4 11.3 (287) 7.17 (182) 14.69 (373) 5.91 (150) 12.4 (316) 18.4 (468) 36 (16.3)
DN-160 6 12.6 (321) 10.08 (256) 19.06 (226) 8.78 (223) 14.7 (372) 21.6 (549) 61 (27.7)
DN-200 8 13.9 (352) 12.40 (315) 23.39 (284) 11.14 (283) 16.4 (415) 25.4 (645) 87 (39.5)
DN-250 10 14.9 (378) 14.41 (366) 27.14 (689) 13.11 (333) 17.3 (440) 28.0 (712) 114 (52)
2.1 - Dimension Call-outs for Standard and IQ-series TSS valves (cross-reference to Tables 2.3 and 2.4)
FLANGE
TYPE
NOM.
ID
BONNET
THICKNESS
“E”
ACTUAL
I.D.
“F”
ISO
FLANGE
O.D.
“G”
CONFLAT
FLANGE
O.D.
“G”
FLANGE-
TO-FLANGE
THICKNESS
“H”
TOTAL
VALVE
HEIGHT
“T”
DN-63 21/22.64 (67) 2.76 (70) 5.35 (136) 4.45 (113) 2.76 (70) 5.5 (140)
DN-80 3 2.68 (68) 3.15 (80) 5.71 (145) CALL 2.54 (65) 5.5 (140)
DN-100 4 2.87 (73) 4.02 (102) 6.93 (176) 5.94 (151) 2.76 (70) 5.7 (144)
DN-160 6 3.07 (78) 6.02 (153) 8.86 (225) 7.99 (203) 3.15 (80) 6.1 (155)
DN-200 8 3.27 (83) 8.39 (213) 11.34 (288) 10.74 (273) 3.15 (80) 6.5 (165)
DN-250 10 3.54 (90) 10.28 (261) 13.78 (350) 12.0 (305) 3.94 (100) 7.1 (179)
66
Visit our Web Site
77
Visit our Web Site
88
Visit our Web Site www.n-c.com
INTELLISYS SOFTSHUTTM GATE VALVE MODELS
TSS-OP-LIT 08/11
4.0 - Theory of Operation
The TSS-series valve is designed for downstream pressure control. As such,
it is one of four important components in a pressure control system. The other
three essential components include a host system computer, a controller mod-
ule (APC, IQA or IQD) and one or two vacuum gauges, such as a Capacitance
Diaphragm Gauge (CDG). Most manufacturers’ vacuum gauges can be used
to provide the vacuum measurement signal, provided they have a voltage out-
put proportional to pressure. Please see Appedix I for summarized connection
information. More complete signal pin-out and communications information
can be found in Nor-Cal Adaptive Pressure Controller Operating Manual, part
# APC-OP-LIT
FIGURE 4.1 TYPICAL INSTALLATION AND CONFIGURATION OF A
TSS-SERIES CONTROL VALVE (DASHED LINES REPRESENT TSS-IQA
OR IQD INSTALLATION)
Initialization Sequence: Before typical pressure or position control can
begin, the TSS-series valve needs to complete an initialization sequence that
lasts for approximately 30-40 seconds, depending on the size and start-
ing position of the valve. The primary purpose for this operation is for the
controller to determine the fully open and closed points, as well as for certain
motor and position calibration steps to occur. When the valve controller is
first powered on, the amber FAULT light will be illuminated and the OPEN/
CLOSE LEDs will blink in an alternating fashion. To start the initialization
sequence, press OPEN-OPEN-CLOSE-CLOSE on the controller panel. Once
the initialization sequence is complete, the valve will move to the fully open
position and the green OPEN LED will illuminate.
4. TheoryofOperation
The TSS-series valve is designed for downstream pressure control. As such, it is one of four important
components in a pressure control system. The other three essential components include a host system
computer, a controller module (APC, IQA or IQD) and one or two vacuum gauges, such as a Capacitance
Diaphragm Gauge (CDG). Most manufacturers’ vacuum gauges can be used to provide the vacuum
measurement signal, provided they have a voltage output proportional to pressure. Please see Appedix I
for summarized connection information. More complete signal pin-out and communications information
can be found in Nor-Cal Adaptive Pressure Controller Operating Manual, part # APC-OP-LIT
Vacuum
Chamber
APC Controller
Vacuum gauge(s)
Host system with RS-
232, Analog/TTL or
DeviceNet
communications
Nor-Cal TSS-series valve
Pump
Figure4.1–Typicalinstallationandconfiguration ofaTSS-seriescontrolvalve
(dashedlinesrepresentTSS-IQAorIQDinstallation)
Initialization Sequence: Before typical pressure or position control can begin, the TSS-series valve
needs to complete an initialization sequence that lasts for approximately 30-40 seconds, depending on
the size and starting position of the valve. The primary purpose for this operation is for the controller to
determine the fully open and closed points, as well as for certain motor and position calibration steps to
occur. When the valve controller is first powered on, the amber FAULT light will be illuminated and the
OPEN/CLOSE LEDs will blink in an alternating fashion. To start the initialization sequence, press OPEN-
OPEN-CLOSE-CLOSE on the controller panel. Once the initialization sequence is complete, the valve
will move to the fully open position and the green OPEN LED will illuminate.
Normal Operation: After the initialization sequence is complete normal operation of the TSS control
valve is possible. There are two primary modes of operation, a) position control mode and b) pressure
control mode.
In Position control mode the valve will move to any position in its range based on a position set-point
command from the host. The valve will remain in that position until instructed to do otherwise. Position
control mode can be useful in certain cases where pre-determined amount of baffling or throttling is
necessary.
Pressure control mode, on the other hand, is used whenever control to a specific system pressure level is
desired. The host provides the set-point value and the throttle valve strives to achieve that set point as
quickly as possible. During pressure control mode, external perturbations such as flow changes and
plasma events will automatically be compensated for by the APC, IQA or IQD controller module so that
the pressure set-point is maintained.
Part # LIT-TSS-O Contact Nor-Cal Intellisys™ Customer Support
Rev 260805.doc at 800-824-4166 ext. 186 or via the web at http:/www.n-c.com
Nor-Cal
TSS-series
Valve
Normal Operation: After the initialization sequence is complete normal
operation of the TSS control valve is possible. There are two primary modes of
operation, a) position control mode and b) pressure control mode.
In Position control mode the valve will move to any position in its range based
on a position set-point command from the host. The valve will remain in that
position until instructed to do otherwise. Position control mode can be use-
ful in certain cases where pre-determined amount of baffling or throttling is
necessary.
Pressure control mode, on the other hand, is used whenever control to a spe-
cific system pressure level is desired. The host provides the set-point value and
the throttle valve strives to achieve that set point as quickly as possible. During
pressure control mode, external perturbations such as flow changes and
plasma events will automatically be compensated for by the APC, IQA or IQD
controller module so that the pressure set-point is maintained.
Tuning: All Nor-Cal controller modules contain an Adaptive Pressure Control
Algorithm that has been designed to work over a wide range of flow- and
pressure-combinations. There are therefore no learn modes” to execute, nor
does the user have to set PID parameters. In some instances, however, vacu-
um system design may affect the closed loop pressure control time constants.
As a result, pressure control performance may at times be affected. If satisfac-
tory pressure control cannot be achieved with the Adaptive Pressure Control
Algorithm, please contact Nor-Cal Products Intellisys Customer Support.
99
Visit our Web Site
1010
Visit our Web Site
1111
Visit our Web Site
1212
Visit our Web Site
1313
Visit our Web Site
1414
Visit our Web Site www.n-c.com
INTELLISYS SOFTSHUTTM GATE VALVE MODELS
TSS-OP-LIT 08/11
APPENDIX I - Summary Valve and Controller Connection Information, Conti.
Pin-Out Wiring Diagrams
Switch 1 Switch 2 Switch 3 Switch 4
IQA DIP Switches
IQA Auxiliary Connector
Pin Signal Assignment
IQA Gauge Connector
Pin Signal Assignment
IQA Analog/TTL Connector
Pin Signal Assignment
Figure A-1.2
Figure A-1.3
1515
Visit our Web Site
1616
Visit our Web Site
1717
Visit our Web Site
1818
Visit our Web Site www.n-c.com
INTELLISYS SOFTSHUTTM GATE VALVE MODELS
TSS-OP-LIT 08/11
Throttling Gate Valves with IQA or IQD Control Module
Size
Family Flange Type Flange
Size O-ring Option
2
250 ISO 63 Viton (leave blank)
300 ISO 80 Perlast G74P (enter PP7)
400 ISO 100
600 ISO 160
800 ISO 200
1000 ISO 250
250 CF or CFM 450
400 CF or CFM 600
600 CF or CFM 800
800 CF or CFM 1000
1000 CF or CFM 1200
Standard Throttling Gate Valves (to be operated by a stand-alone APC-series controller)
APPENDIX III - Valve, Accessories and Cable Assembly Ordering Information
TSS- IQX1
_ _ _ _ _ _
_ _ _ _
Size
Family Flange Type Flange
Size O-ring Option2
250 ISO 63 Viton (leave blank)
300 ISO 80 Perlast G74P (enter PP7)
400 ISO 100
600 ISO 160
800 ISO 200
1000 ISO 250
250 CF or CFM 450
400 CF or CFM 600
600 CF or CFM 800
800 CF or CFM 1000
1000 CF or CFM 1200
TSS
_ _ _ _ _ _
_ _ _ _
2NOTE: Other O-ring materials are available. Call Nor-Cal Intellisys Customer Support for details
1NOTE: “X” refers to the communications mode. D = DeviceNet, A = analog, etc…
1919
Visit our Web Site
2020
Visit our Web Site www.n-c.com
INTELLISYS SOFTSHUTTM GATE VALVE MODELS
TSS-OP-LIT 08/11
Appendix IV - Limited Warranty and Intellectual Property Coverage
Products manufactured by Nor-Cal Products, Inc. (hereinafter referred to as “Nor-Cal”) are warranted against defects in material and workmanship for a
period of twelve (12) months from the date of shipment from Nor-Cal to the buyer. Any modification to the product by the buyer or their agent voids this war-
ranty. Liability under this warranty is expressly, limited to replacement or repair (at Nor-Cal s option) of defective parts. Nor-Cal may at any time discharge its
warranty as to any of it products by refunding the purchase price and taking back the products. This warranty applies only to parts manufactured, and labor
provided, by Nor-Cal under valid warranty claims received by Nor-Cal within the applicable warranty period and shall be subject to the terms and conditions
hereof. Expendable items such as tubes, heaters, sources, bellows, etc., by their nature may not function for one year; if such items fail to give reasonable service
for a reasonable period of time, as determined solely by Nor-Cal, they will be repaired or replaced by Nor-Cal at its election. All warranty replacement or repair
of parts shall be limited to equipment malfunctions which, in the sole opinion of Nor-Cal, are due or traceable to defects in original materials or workmanship.
Malfunctions caused by abuse or neglect of the equipment are expressly not covered by this warranty. Nor-Cal expressly disclaims responsibility for any loss or
damage caused by the use of its products other than in accordance with proper operating and safety procedures. Reasonable care must be taken by the user to
avoid hazards. In-warranty repaired or replacement parts are warranted only for the remaining unexpired portion of the original warranty period applicable to
the parts that have been repaired or replaced. After expiration of the applicable warranty period, the buyer shall be charged at Nor-Cal’s then current prices for
parts and labor plus transportation. Except as stated herein, Nor-Cal makes no warranty, expressed or implied (either in fact or by operation of law), statutory or
otherwise: and, except as stated herein, Nor-Cal shall have no liability for special or consequential damages of any kind or from any cause arising out of the sale,
installation, or use of any of its products. Statements made by any person, including representatives of Nor-Cal, which are inconsistent or in conflict with the
terms of this warranty shall not be binding upon Nor-Cal unless reduced to writing and approved by an officer of Nor-Cal. Merchandise may be returned at the
sole discretion of Nor-Cal Products, but not more than 60 days after shipment. A fee may be charged for restocking the item. An RMA number must be obtained
from Nor-Cal before returning any merchandise.
Intellectual Property Coverage
The products described in this manual are covered under U.S. Patent numbers 5,134,349; 5,202,613; 5,321,342; and 6,612,331. Additional patents are pending.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Nor-Cal Products Intellisys SoftShut TSS-IQD User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI