Symmons S-5204 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3079 REV 0 09/18/14
S-5204-TRM
Ballina
Tub/Hand Shower Trim
Operation & Maintenance Manual
Model Numbers Specifications
S-5204-TRM Tub/Hand Shower Trim
Tub/hand shower trim with lever handle and secondary
integral diverter handle includes wall connection, cradle
for hand shower mounting, non-diverter tub spout,
in-line vacuum breaker, exible metal hose and 3 mode
hand shower with 2.5 gpm (9.5 L/min) ow restrictor.
Components made from metal and nonmetallic materials
plated in standard polished chrome nish.
Modifications Compliance
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-412HSB 30" slide bar in place of wall cradle on
hand shower units
-BBZ Brushed bronze finish
-STN Satin nickel finish
-ASME A112.18.1; CSA B125.1
Warranty
Limited Lifetime - to the original end purchaser in
consumer installations.
5 Years - for commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Note: Append appropriate -sufx to model number.
c
2
Dimensions
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3079 REV 0 09/18/14
Measurements
A Ø 2 1/2", 64 mm
B
1/2" IPS thread must protrude
1/2" from nished wall
C Ø 7 1/2", 191 mm
D 32", 813 mm
E 12", 305 mm
F 3", 76 mm
G 4 1/8", 105 mm
H 7", 178 mm
I
(Rough in)
2 3/8" ± 1/2", 60 mm ± 13 mm
J 1/2", 13 mm
K 1/2" NPT
Notes:
1) All dimensions measured from nominal rough-in (see I as reference).
2) Dimensions are subject to change without notice.
A
C
C
A
A
D
D
E
E
B
B
F
F
G
G
I
I
J
J
H
H
K
K
Floor
Floor
3
Parts Breakdown
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3079 REV 0 09/18/14
Replacement Parts
Item Description Part Number
A Hand Shower 412W
B Cradle T-635
C
D
Vacuum Breaker
60" Hose
EF-104
E
H
Handle
Set Screw
T-660
F Dome Cover T-633
G
J
I
Mounting Screws
Mounting Plate
Shower Escutcheon
T-631A-
NS-K001
K Diverter Handle T-630
L Tub Spout 522TS
Notes:
1) Append -BBZ to part number for brushed bronze
nish; -STN for satin nickel.
2) Append -1.5 or -2.0 to hand shower for low ow.
Required for Installation
Adjustable wrench
Phillips head screwdriver
Allen wrench (1/8")
Plumber tape
H
A
B
C
D
I
J
L
F
K
E
G
4
Installation
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3079 REV 0 09/18/14
Note:
For valve body installation, please
see valve body installation guide.
1) Install large plastic mounting
plate (J) to shower valve
(S-4002-BODY). Secure with two
screws (G).
2) Attach secondary integral
diverter (K) to shower
escutcheon (I).
3) Attach shower escutcheon (I) to
large plastic mounting plate (J).
Note: Tabs should snap into place.
4 ) Install dome cover (F) to valve
by turning clockwise.
5) Install shower handle (E) to valve.
Secure handle by tightening set
screw (H).
Note: Handle should be facing the
6 o'clock position.
6) Install tub spout (L) to pipe
tting. Turn clockwise to secure.
7) Install cradle (B) to pipe tting.
Turn clockwise to tighten.
8) Attach large end of hand shower
hose (D) to hand shower (A).
Attach small end of hand shower
hose (D) and gasket to in-line
vacuum breaker (C). Connect in-
line vacuum breaker to cradle (B).
Turn clockwise to tighten.
1
2
G
J
K
I
I
J
1
2
L
1
2
B
3
1
4
2
D
A
B
C
D
1
2
F
1
2
E
H
5
Care and Cleaning
1) Clean nished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse
with water.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then
quickly rinse with water.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3079 REV 0 09/18/14
1) Turn shower handle counterclockwise approximately
1/4 turn to put valve in cold position.
2) Turn shower handle counterclockwise approximately
1/2 turn to put valve in warm position.
3) Turn shower handle counterclockwise approximately
3/4 turn to put valve in hot position.
1) Turn diverter lever left for tub spout operation.
2) Turn diverter lever right for hand shower operation.
Operation
Temperature Control Diverter Control
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Symmons S-5204 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI