King Electric TKIT-2A, TKIT-1A Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the King Electric TKIT-2A Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
! !
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND
SAFETY DATA TO AVOID PROPERTY DAMAGE AND
KING ELECTRIC MFG CO · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH:206 762 0400 · FAX: 206
WARNING
!
READ CAREFULLY - These instructions were written to help prevent difficulties that might arise during thermostat
installation. Studying the instructions first may save considerable time and money later. Observing the following
procedures will keep installation time to a minimum. Save these instructions for future use.
TKIT-1 &
TKIT-2
Inbuilt Thermostat for the PX, KT,
KTW, PAW, W and WHF model heat-
ers
INSTRUCTIONS
WARNING: Turn oFf power
at the breaker before
installing.
1. Mount Thermostat with
provided screws.
2. Wire the thermostat with
RED thermostat wires to
breaker, BLACK thermostat
wires to heater, white
neutral wires to heater.
3. Install heater assembly into
wall can.
4. Remove 1/2” knockout in
grill.
5. Mount grill with
provided screws.
6. Place plastic knob by
pushing through grill
opening.
WIRING DIAGRAMS
TKIT-1 Single Pole
!
!
Approved for
US & Canada
Black Wires (Supply)
Red Wires (Load)
White Wires (Neutral)
SPECIFICATIONS Resistive Load
Source 120 VAC 25 AMP @ 3000W
Source 208 VAC 25 AMP @ 5200W
Source 220 VAC 25 AMP @ 5500W
Source 240 VAC 25 AMP @ 6000W
Source 277 VAC 18 AMP @ 4985W
Temperature range 40°-90°F (4°-32°C)
Frequency 50-60 Hz
Accuracy 7°F +/- 3.5°C
Inductive Load 1/2HP
Snap Action / Open On Temp. Rise/ Bimetal Sensor
(Cycle)
(L2)
Rev 9.19.18
Single Pole Kit can be used on 120V or 240V
To Breaker 240V
or Neutral 120V
To Breaker
Fig 1
Fig 2 Fig 3
Back View
Side View
TKIT-2 Double Pole
2
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
!
!
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND
SAFETY DATA TO AVOID PROPERTY DAMAGE AND
KING ELECTRIC MFG CO · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH:206 762 0400 · FAX: 206 763 7738 · www.king-electric.com
TKIT-1 &
TKIT-2
Approved for
US & Canada
SPECIFICATIONS Resistive Load
Source 120 VAC 25 AMP @ 3000W
Source 208 VAC 25 AMP @ 5200W
Source 220 VAC 25 AMP @ 5500W
Source 240 VAC 25 AMP @ 6000W
Source 277 VAC 18 AMP @ 4985W
Temperature range 40°-90°F (4°-32°C)
Frequency 50-60 Hz
Accuracy 7°F +/- 3.5°C
Inductive Load 1/2HP
Fig 1
Rev 9.19.18
Inbuilt Thermostat for the PX, KT,
KTW, PAW, W and WHF model heat-
ers
PAW Models
KT & KTW Models W Models
WHF Models
MOUNTING LOCATIONS
Use the two sheet metal screws provided to fasten the mounting bracket as shown above. Use the two machine
screws to mount the thermostat to the mounting bracket.
PX Models
/