Samsung DB98-17031A(5) User manual

Category
Air filters
Type
User manual

This manual is also suitable for

DB98-17031A(5)
AW0505M AW0595M
Window-type Room Air Conditioner
(Cool)
E F
OWNER’S
INSTRUCTIONS
AW050BM
AW050DM
E-2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product at their
own
discretion. Instead, they are requested to directly contact a designated
service
center or the outlet at which the product was purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch
off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be
damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the
breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do
not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries.
(If applicable)
When using a wireless remote control, the distance should not be more than 7
meters
from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Risk of electric shock. Can cause injury or death. Disconnect all
remote
electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar
qualified
person in order to avoid a hazard.
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Never store or ship the air conditioner upside down or sideways to avoid damage
to
the compressor.
The appliance is not intended for use by young children or infirm persons without
supervision:
Young children should be supervised to ensure that they do not play
with
the appliance.
Max current is measured according to IEC standard for safety and current is
measured
according to ISO standard for energy efficiency.
OTHERS
Before throwing out the device, it is necessary to pull back the battery cells and
get
rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectl
y, refrigerant may blow out and come into contact with your skin,causing
injur
y. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally
responsible manner.
D
ISPOSING OF THE UNIT
Register your product at www.samsung.com/global/register
Contents
PREPARING YOUR AIR CONDITIONER
Safety Precautions ......................................................................................... 2
Description of Each Component .................................................................... 4
Getting Started ............................................................................................... 5
OPERATING YOUR AIR CONDITIONER
Cooling Your Room ........................................................................................ 6
Ventilating Your Room .................................................................................... 7
Switching the Air Conditioner Off .................................................................... 8
Adjusting the Air Flow Direction Horizontally .................................................. 9
Adjusting the Air Flow Direction Vertically ...................................................... 9
RECOMMENDATIONS FOR USE
Power Failure ................................................................................................. 10
Temperature and Humidity Ranges ................................................................ 10
Cleaning Your Air Conditioner ........................................................................ 11
Solving Common Problems ............................................................................ 12
Technical Specifications ................................................................................. 13
E-
3
Description of Each Component
E-
4
Design and shape are subject to
change.
Air outlet
Inner air flow
blades (right/left
orientation)
Air inlet (Inside)
Outer air flow blades
(up/down orientation)
- Except AW0505M/AW0595M
Power plug
(The type of power plug
may differ, depending on
the local power supply.)
Operating mode
selection dial
Thermostat
control
Ventilation lever
- Except AW0505M/AW0595M
Air outlet
Air inlet (Outside)
Air filter (Inside)
AW050BM/AW050DM
AW050BMAW050DM
Getting Started
You have just purchased a Samsung window-type room air conditioner which should be
installed following your Owner’s Instructions.
Your Owner's Instructions contain much valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit's
features.
The illustrations in the step-by-step procedures use four different symbols:
E-
5
PRESS PUSH IMPORTANT NOTE
Cooling Your Room
To control the direction of the air flow, refer to page 9.3
Turn the operating mode selection dial and set it to " " ,
" " or " "
Result
: The air conditioner starts up in cool mode.
You can change modes at any time.
Turn the THERMOSTAT control to the desired position.
You must select the COOL mode if you wish to adjust the:
Cooling
temperature
Fan
speed when Cooling
1
2
Possible temperatures: Can be set between 18 C and 29 C.
Result: The air conditioner starts cooling if the room temperature is
higher
than the selected temperature.
E-
6
Ventilating Your Room
If the air in your room is stale, you can ventilate the room using the
Fan
feature. (Except AW0505M / AW0595M / AW050BM / AW050DM)
1
Turn the operating mode selection dial and set it to " " or " " posi-
tion
.
Result: The air conditioner starts up in fan mode.
:The fan turns rapidly.
: The fan turns slowly.
You can change modes at any time.
2
To control the direction of the air flow, refer to page 9.
3
If
you wish to discharge stale air, push the ventilation lever on the front
of
the unit to the right and open position ( ).
Result
:
The air inside the room circulates and stale air is discharged
outside
.
Otherwise,
push the ventilation lever to the left and closed position ( ).
Result
: The air simply circulates inside the room.
HS
ILG
NE
Switching the Air Conditioner Off
To switch the unit off, simply set the operating mode selection dial to the
"
"
position.
Result: The air conditioner stops operating.
You can switch the air conditioner off whenever you want.
1
E-
8
Adjusting the Air Flow Direction Vertically
The outer air flow blades can be adjusted to control the vertical air
flow
direction. (Except AW0505M / AW0595M / AW050BM /AW050DM)
RECOMMENDATION
When..
.
Cooling
Adjust the blades to face...
Upwards.
Adjust the air flow blades to the desired position, by pushing them
upwards
or downwards.
If
you orient the air flow blades downwards and the unit operates
in
Cool mode for long periods of time, dew may:
-
Form on the surface of the blades
-
Drip from the blades
E-
9
Depending on the position of the unit in your room, you can adjust
the
orientation of the inner air flow blades on the unit.
Adjust the air flow blades to the desired position by sliding them side to side.
HS
ILG
NE
Power Failure
Temperature and Humidity Ranges
If the air conditioner is used at... Then...
Higher temperature The automatic protection feature may be triggered
and the air conditioner stopped.
Lower temperature A water leakage or some other malfunction may happen
if the heat exchanger freezes.
Higher humidity levels Water may condense on and drip from the surface of the unit
if it is used for long periods.
The follow ing table indicates the tem perature and hum idity ranges
w ithin w hich the air conditioner can be used.
Mode Indoor
Temperature
Outdoor
Temperature
Indoor Humidity
Cooling 21 C to 32 C approx. 21 C to 43 C approx. 80% or less
If a power failure occurs, the air conditioner is switched off.
When the power comes back on, the air conditioner starts up again
automatically.
E-
10
E-
11
Cleaning Your Air Conditioner
Open the front grille by pulling the tabs on both sides of the grille.
Then
lift it up slightly to open the front grille completely.
1
Remove all dust on the air filter with a vacuum cleaner or brush.
3
Grab the tabs on the filter and pull it up and out.
2
When you have finished, insert the air filter back into its original position.
4
Wipe the surface of the unit with a neutral detergent
and
then wipe it again with dry cloth.
(Be
sure not to use benzene, solvent or other chemical products.)
5
Be sure to clean the air filter periodically to maintain the air conditioner
in
the best condition for a long period of time.
When cleaning the air conditioner, turn it off and pull out the
power
plug.
Set the fan going for a few hours to
dry
the inside of the air conditioner
thoroughly
.
If you... Then...
Will not be using the
air
conditioner for a
long
period of time
Set
the fan going for a few
hours
to dry the inside of the air
conditioner
thoroughly.
Switch
the air conditioner off and
unplug
it from the wall socket.
Clean
the filter and outer surfaces.
Have
not used the air
conditioner
for a long
period
of time
HS
ILG
NE
Solving Common Problems
Explanation / Solution
Check for a power failure.
Check the voltage.
(See the technical specifications)
Check the power plug for disconnection.
Check to see whether the operating mode selection dial is placed in the
" " position. (Set it to the desired position.)
Check to see whether the room temperature is too low.
- Refer to page 10 for details about temperature condition.
Set the THERMOSTAT control to the desired position.
- When the number on the THERMOSTAT control is too high,
the room temperature may be too warm.
Check to see whether there is an open window or leakage of cool
air to the outside.
- Close the window, and fill the gap.
Check to see whether there is any obstacle adversely affecting
the flow of the air inside and outside the room.
- Remove the obstacle or change the position of the air conditioner.
Check to see whether the air filter is clogged with dust or
contaminated with foreign substances.
- Clean the air filter.
Check to see whether there is any direct sunlight facing the air conditioner.
- Block the sunlight with a sunshade.
Check to see whether there is any electric device generating heat.
- Do not use the air conditioner together with any heating device.
Ventilate the room.
Problem
The air conditioner
does not operate at all.
The air comes out smoothly,
but cooling is not effective.
Odors are permeating the
room during air conditioning.
Before contacting an authorized service center, perform the following simple checks.
They may save you the time and the expense of an unnecessary call.
E-
12
Technical Specifications
Model Power Supply
AW0505M
AW0595M
Design and specifications are subject to change without notice.
115V~, 60Hz
E-
13
AW050BM
AW050DM
Labor
1 Year (In home)
Parts
1 Year
Printed in Korea
YOUR SAMSUNG ROOM AIR CONDITIONER
WARRANTY
Limited Warranty to Original Purchaser
Samsung will repair or replace, at our option, this product if found defective within the warranty
period beginning from the original date of purchase. This Samsung Product is warranted by
SAMSUNG ELECTRONICS CANADA Inc. against manufacturing defects in materials or
workmanship for the period specified.
Limited 5-Years Compressor Warranty
Within one year of purchase Samsung Electronics Canada Inc. will provide a replacement
compressor if it is found to be defective in material or workmanship. During the existing four
years (second through fifth year) Samsung Electronics Canada Inc. will provide a replacement
only, without charge, if it is found to be defective in material or workmanship. Labor to install
the compressor during these existing four years is not included in the warranty. All warranty
repairs must be performed by a Samsung Authorized Service Centre.
Obligation of the Original Owner
The original dated purchase receipt must be retained as proof of purchase and presented to
the Authorized Service Centre before warranty services are rendered.
Exclusions of the Warranty
This warranty does not cover damage due to accident, fire, flood and/or other Acts of God:
misuse, incorrect line voltage, improper installation, improper or unauthorized repairs,
commercial use, or damages which occur in shipping. Exterior and interior finish and plastic
parts, are not covered under this warranty, Customer adjustments which are explained in the
instruction manual are not covered under the terms of this warranty. This warranty will
automatically be voided for any unit found with a missing or altered serial number.
This warranty is valid only on products purchased and used in Canada.
SAMSUNG ELECTRONICS CANADA INC.
55 Standish Court, Mississauga, Ontario L5R 4B2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Samsung DB98-17031A(5) User manual

Category
Air filters
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI