Little GIANT 506065 Installation guide

Category
Water pumps
Type
Installation guide
ENGLISH
ENGLISH
EN
This instruction sheet will provide you with information required to safely own
and operate your Little Giant WRSC-6 kit. This unit is designed to pump
wastewater from laundry trays, washing machines, sinks, or dehumidifiers. It is
not designed to pump raw sewage, fluids other than water, or fluids with solids.
The inlet screen will remove many solids over 1/8” diameter, but large amounts
of solids can clog screen and result in pump failure. Maximum fluid temperature
is 125° F. Unit is designed to fit under most sinks so in many cases it is not
necessary to recess the unit into the floor.
This instruction sheet covers the standard models in this pump series. This form
is applicable to other models in this series not listed by catalog number in the
replacement parts list section of this pamphlet. If the catalog number of your
pump is not listed in the replacement parts section, then exercise caution when
ordering replacement parts. Always give the catalog number of your pump
when ordering replacement parts.
The Little Giant unit you have purchased is of the highest quality workmanship
and material. It has been engineered to give you long and reliable service.
Little Giant pumps are carefully packaged, inspected, and tested to ensure safe
operation and delivery. When you receive your pump, examine it carefully to
determine that there are no broken or damaged parts that may have occurred
during shipment. If damage has occurred, make notation and notify the firm
where you purchased the pump. They will assist you in replacement or repair,
if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL,
OPERATE OR SERVICE THE LITTLE GIANT PUMP. KNOW THE PUMP
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS
FOR FUTURE REFERENCE.
SAFETY GUIDELINES
1. Make certain that the unit is disconnected from the power source before
attempting to service or remove any component!
2. Do not use to pump flammable or explosive fluids such as gasoline, fuel
oil, kerosene, etc. Do not use in explosive atmospheres or hazardous
locations as classified by NEC, ANSI/NFPA70. Pump should be used with
liquids compatible with pump component materials.
3. Do not handle the pump with wet hands or when standing on a wet or
damp surface or in water.
4. Do not pull the pump out of the water by the power cord when the pump
is operating or connected to power source.
5. This pump is supplied with a grounding conductor and/or grounding-type
attachment plug. To reduce the risk of electrical shock, be certain that it is
connected to a properly grounded grounding type receptacle.
6. The National Electric Code requires a ground fault circuit interrupter (GFCI)
be installed in the branch circuit supplying fountain equipment, pools, etc.
7. In any installations where property damage and/or personal injury might
result from an inoperative or leaking pump due to power outages,
discharge line blockage, or any other reason, a backup system(s) and/or
alarm should be used.
8. Support pump and piping during assembly and when installed. Failure to do
so may cause piping to break, pump to fail, motor bearing failures, etc.
9. The pump motor is equipped with an automatic resetting thermal protector
and may restart unexpectedly. Protector tripping is an indication of motor
overloading as a result of excessively high or low voltage, inadequate
wiring, incorrect motor connections, or a defective motor or pump.
10. If pump is an oil-filled pump, the motor housing is filled with a dielectric
lubricant at the factory for optimum motor heat transfer and lifetime
lubrication of the bearings. Use of any other lubricant could cause damage
and void the warranty. This lubricant is non-toxic; however, if it escapes the
motor housing, it should be removed from the surface quickly by placing
newspapers or other absorbent material on the water surface to soak it up,
so aquatic life is undisturbed.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not connect to
voltage other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third prong is to ground
the pump to prevent possible electrical shock hazard. DO NOT REMOVE the
third prong from the plug. A separate branch circuit is recommended. Do not
use an extension cord. Do not cut plug from the cord. If the plug is cut or the
cord is shortened, then this action will void the warranty.
3. If the cord is equipped with stripped lead wires, such as on 230 V models, be
sure that the lead wires are connected to a power source correctly. The (green/
yellow) wire is the ground. The (blue or white) and the (brown or black) are live.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER
ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.
4. Check local electrical and building codes before installation. The installation
must be in accordance with their regulations as well as the most recent
National Electrical Code (NEC).
5. Plug into a grounded receptacle with vent tube pointed down. Vent tube
must remain unobstructed for proper pump operation.
6. If installed in basement, plug connection should be four feet or more above floor,
especially if basement floods. Be sure electrical connections cannot be reached by
rising water. Under no circumstances should outlet box or receptacle be located
where it may become flooded or submerged by water.
OPERATION
1. Determine proper location for unit. Unit should be located so that inlet is gravity-fed.
Unit will not draw water up from a lower level. Position and level basin. Keep basin
away from any item that could puncture basin. Position selected should be
convenient to inlet, discharge and vent piping and electrical supply.
2. Plumb inlet. Using proper adapter, plumb discharge to basin cover fitting. Use a
P-trap and a union next to the basin. Use pipe joint compound and hand tighten
only on plastic fittings. A 1-1/2" MNPT x 2" slip pipe adapter is provided if a 2" inlet
is required. See "Typical Installation."
3. Plumb discharge. Using proper adapter, plumb discharge to basin cover fitting. Use
a swing check valve as close as possible to top of basin cover and union. Be sure
check valve is installed in proper flow direction. If check valve is installed backwards,
no water will flow out of unit. Be sure discharge piping is sealed with pipe joint
compound and that lift height of pump is not exceeded. Hand tighten only on plastic
fitting. A 1-1/2" MNPT x 2" slip pipe adapter is provided if a 2" discharge is required.
4. Plumb vent. Plumb vent using 2" threaded pipe to fitting in basin cover. Use pipe
joint compound on threads and hand tighten only on plastic fittings. The basin must
be vented in accordance with state and local codes. A 2" MNPT x 1-1/2" Slip pipe
adapter is provided if a 1-1/2" vent is required.
THIS UNIT WILL NOT OPERATE WITHOUT PROPER VENTING. CAUTION: Do not
use a mechanical vent with this product. A mechanical vent will cause improper
operation of the automatic switch.
5. Test Unit. Connect power cord to electrical supply as stated in ELECTRICAL
CONNECTIONS. Secure power cord to piping
with ties or tape. Fill unit with
water through inlet. Pump should turn on with 4" to 7" (10.2 - 17.8 cm) of
water in tank, and turn off when 1½" to 3½" (3 - 8 cm) of water is left in tank.
See Pump Troubleshooting Guide if problems occur.
1
WRSC-6
SPECIFICATIONS • CARACTÉRISTIQUES TECHNIQUES • ESPECIFICACIONES
Model No.
Modèle No.
N° de Modelo
Catalog No.
Rèfèrence
Catalogue
Cataloga
Número
Volts
Volts
Voltios
Hertz
Hertz
Hertz
Amps
Ampères
Amperios Watts
Watts
Watts
Gallons per hour (GPH) at ht.
Litres par huere
Litros por hora
Shutoff (FT.)
Hauteur à
débit nul
A Válvula
Cerrda
PSI
Kg/cm2S R
5' 10' 15'
WRSC-6 506065 115 60 13 9 720 2750 1750 750 18 7.8
WRSC-6 506066 230 50 7 5 720 2580 1050 12 5.2
Franklin Electric Co., Inc.
Oklahoma City, OK
1-800.701.7894 • Fax: 1-405-228.1561
www.LittleGiantPump.com
FR
FRANÇAIS
FR
Cette liste de directives vous fournit les renseignements nécessaires pour
utiliser une WRSC-6 Little Giant en toute sécurité. Cette pompe est conçue pour
pomper les eaux usées des bacs à linge sale, des machines à laver, des éviers
ou des déshumidificateurs.
Elle n’est pas conçue pour pomper des eaux d’égout, des liquides autres que
de l’eau ou des liquides comportant des solides. L’écran d’entrée retiendra
beaucoup de particules dépassant 1/8 po de diamètre; toutefois, une grande
quantité de matières solides peut bloquer l’écran et causer une panne de la
pompe. La température du liquide ne doit pas dépasser 125°F. La pompe est
conçue pour aller sous la majorité des éviers; il est donc dans la plupart des
cas inutile de l’encastrer dans le plancher.
La présente feuille d’instructions décrit les modèles standard de cette série de
pompe. Ce document s’applique également à d’autres modèles de cette série
qui ne sont pas indiqués par leur numéro de catalogue dans la section des
pièces de remplacement du présent document. Si tel était le cas avec votre
pompe, il faudra être particulièrement attentif au moment de commander des
pièces. Toujours donner le numéro de catalogue de votre pompe lors de la
commande de pièces.
Votre nouvelle pompe Little Giant a été fabriquée avec les meilleurs matériaux
et avec le plus grand soin. Elle a été conçue pour foncionner bien et
longtemps.
Les pompes Little Giant sont soigneusement emballées, et testées pour assurer
une livraison et un fonctionnement sans problèmes. Lorsque vous recevez
votre pompe, examinez-la attentivement pour vous assurer qu’il n’y a pas eu de
pièce cassée ou endommagée pendant l’acheminement. S’il y a eu des dégats,
prenez-en note et signalez-le au magasin où vous avez acheté la pompe. Ils
vous aideront pour le remplacement ou la réparation, si nécessaire. Cette
pompe est conçue pour pomper de l’eau. NE POMPEZ PAS de produit
chimique, de solvant, d’eau salée, ou de liquides épais tels que des huiles ou
de la graisse.
BIEN LIRE LES INSTRUCTIONS AVANT D’INSTALLER, DE FAIRE
FONCTIONNER OU D’ENTRETENIR LA POMPE LITTLE GIANT. IL FAUT
CONNAÎTRE L’APPLICATION, LES LIMITESET LES DANGERS POTENTIELS
DE LA POMPE. PROTÉGEZ-VOUS ET LES AUTRES EN RESPECTANT
TOUTES LES NORMES DE SÉCURITÉ. LE NON-RESPECT DES
INSTRUCTIONS PEUT CAUSER DES ATTEINTES AUX PERSONNES OU À
LA PROPRIÉTÉ! GARDER LE PRÉSENT DOCUMENT POUR RÉFÉRENCE
ULTÉRIEURE.
SERVICE INSTRUCTIONS
MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE POWER
SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY
COMPONENT!
1. To clean inlet filter remove the 4 cover plate screws (21), cover plate (19),
seal ring (item 28), and screen (item 27). Clean inlet screen using a mild
detergent and water. Examine o-ring and if deformed, replace with new
o-ring. See replacement parts list.
2. Sediment may build up in basin causing pump to operate improperly.
Remove 10 1/4-20 screws (item 21) from cover. Remove cord grommet and
loosen cords to allow slack and then remove cover.
Remove pump and clean basin using a mild detergent and water.
Reassemble in reverse order. Torque screws (item 21) 18–20 in–lbs.
3. If pump alignment plate is removed, it must be reinstalled per plate
alignment diagram (Figure 1).
4. Sediment or lint can clog pump and cause improper operation. If necessary,
remove pump and pull off the pressed-in screen, clean using a mild
detergent and water, and reinstall. Plastic pump base may also be removed
to clean around impeller and inside base. Remove the six base screws and
clean base using a mild detergent and water. Do not remove impeller.
When reinstalling base, be sure seal ring is seated properly in groove and
torque screws to 12-17 in.-lbs. See pump manual for other information. For
any other pump repair, return the pump to a Little Giant authorized service
center.
5. This unit is permanently lubricated. Oiling is not required. Do not, in any
case, open the sealed portion of the unit or remove housing screws.
6. Remove screws (item 4) that hold base to volute and clean impeller and
volute passage. Do not use strong solvents on impeller.
7. Be sure impeller turns freely after cleaning. WARNING: DO NOT REMOVE
IMPELLER. REMOVAL OF IMPELLER REQUIRES SPECIAL TOOLS
AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER.
8. When reinstalling base, be sure seal ring is seated properly in groove and
torque screws (item 4) to 10–15 in.–lbs.
9. DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY IS VOID IF
MOTOR HOUSING COVER, IMPELLER OR SEALS HAVE BEEN REMOVED.
ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED LITTLE
GIANT SERVICE CENTER.
10. Be certain power cord is in good condition with no nicks or cuts.
1
2
Position the alignment plate inside the basin as shown. This will
position the mounting holes properly when installing the basin
cover. Any other position will prevent assembly of cover.
Placer la plaque de l’alignement à l’intérieur du réservoir, tel
qu’illustré. Ainsi, les trous de montage seront correctement alignés
au moment de la pose du couvercle du réservoir. Tout autre
positionnement de la plaque ne permettra pas la pose du couvercle.
Coloque la placa de alineacion dentro del depósito como se ilustra.
Esto permitirá la alineación apropiada de los agujeros de montaje
cuando instale la cubierta del depósito. Cualquier otra posición no
permitirá armar la cubierta.
Ensure mounting hole (1) lines up with locating rib (2) on inside of
basin.
Le trou de montage (1) s’aligne avec une nervure (2) de
positionnement située à l’intérieur du réservoir.
Los agujeros de montaje (1) se alinean con un saliente de ubicación
(2) dentro del depósito.
Figure 1
PLATE ALIGNMENT DIAGRAM
DIAGRAMME DE L’ALIGNEMENT DE LA PLAQUE
DIAGRAMA DE ALINEACION DE LA PLACA
2
Mounting hole lines up with a locating rib on the inside of the
basin. • Le trou de montage s’aligne avec une nervure de
positionnement située à l’intérieur du réservoir. • Los agujeros de
montaje se alinean con un saliente de ubicación dentro del
depósito.
Position the pump locating plate inside the basin as shown. This
will allow proper alignment of mounting holes when installing the
basin cover. Any other position will not allow assembly of cover. •
Placer la plaque à l’intérieur du réservoir, tel qu’illustré. Ainsi, les
trous de montage seront correctement alignés au moment de la
pose du couvercle du réservoir. Tout autre positionnement de la
plaque ne permettra pas la pose du couvercle. • Coloque la
bomba poniendo la placa dentro del depósito como se ilustra.
Esto permitirá la alineación apropiada de los agujeros de montaje
cuando instale la cubierta del depósito. Cualquier otra posición no
permitirá armar la cubierta.
Figure 3
REPLACEMENT PARTS LIST
ITEM NO.
PART
NO. DESCRIPTION QTY.
1 108101 Handle, pump Poignée, pompe Manivela, bomba 1
2 928004 Seal ring • Anneau d’étanchéité • Anillo de estancamiento 1
3 108034
Pump base, manual, blue • Pompe manuel de base bleue
• Bomba manual de base azul
1
4 909021
Screw/wash e r # 1 0 - 2 4 x 1 / 2 V i s / r o n d el l e N ° # 1 0 - 2 4 x 1 / 2 "
• Tornillo y arandela de #10-24 x 1/2" de pulgada
5
5 108082 Screen, intake • Filtre d’admission • Rejilla, toma 1
6 928028 Seal ring • Anneau d’étanchéité • Anillo de estancamiento 1
7 108051
Housing assemby, automatic, 8’ (115v) • Carter ensemble turbine,
Automatique 2.4 m (115 V) • Cubierta ensamblaje de impulsor, automático
2.4 m (115 V)
1
7 108052
Housing assemby, automatic, 8’ (230v) • Carter ensemble turbine,
Automatique 2.4 m (230 V) • Cubierta ensamblaje de impulsor, automático
2.4 m (230 V)
1
8 108202 Bracket, switch • Patte D’attache, Commutateur •Soporte, Interruptor 1
9 951961
Lead wire assembly • Assemblage fils plumbés • Conjunto de hilos
conductores
1
10 924001
O-ring, Buna-N, 2-007 • Joint torique, Buna-N, 2-007 • Junta tórica,
Buna-N, 2-007
2
11 950322 Switch, miniature • Commutateur, miniature • Interruptor, miniature 1
12 901529
Screw, machine #10–24 x 1/4” • Vis mécanique #10–24 x 1/4”
• Tornillo para metales de #10 -24 x 1/4" de pulgada
1
13 902404
Screw, tap #8–18 x 3/8” • Vis taraudée N° #8-18 x 3/8" • Tornillo, rosca
macho #8-18 x 3/8" de pulgada
1
14 108125 Diaphragm • Diaphragme • Diafragna 1
15 108055
Cover, automatic switch housing • Couvercle, boîtier du contacteur
automatique • Cubierta de la caja del interruptor automático
1
16 909027
Screw/washer #10–24 x 1 3/4” • Vis/rondelle #10-24 x 1-3/4"
• Tornillo y arandela de #10-24 x 1-3/4" de pulgada
4
17 921023
Washer, #10 lock • Rondelle, verrouillage #10 • Arandela de seguridad
#10
1
18 924047
O-ring, Buna-N, 2-131 • Joint torique, Buna-N, 2-131• Junta tórica,
Buna-N, 2-131
1
19 113132 Cover plate, screen • Couvercle plaque, grille • Cubierta de placa, rejilla 1
20 113130 Basin cover • Réservoir couvercle • Depósito cubierta 1
21 901709 Screw, 1/4”–20 x 1/2” • Vis, 1/4”-20 x 1/2” • Tornillo, 1/4”-20 x 1/2” 14
22 924065 Seal ring • Anneau d’étanchéité • Anillo de estancamiento 1
23 113229 Basin • Réservoir • Depósito 1
24 113024 Discharge pipe • Refoulement tuyau • Descarga tubo 1
25 506160
Pump, 6-CIA-ML (115 v) • Pompe, 6-CIA-ML (115 v) • Bomba, 6-CIA-ML
(115 v)
1
25 506161
Pump, 6-CIA-ML (230 v) • Pompe, 6-CIA-ML (230 v) • Bomba, 6-CIA-ML
(230 v)
1
26 925016 Cord grommet • Passe-fil • Arandela aislante de cordón 1
27 113131 Intake screen • D’admission filtre • Toma rejilla 1
28 924066
O-ring, Buna-N, 2-339 • Joint torique, Buna-N, 2-339 • Junta tórica,
Buna-N, 2-339
1
29 113135
Alignment plate ( See page 1) • Plaque d’alignement (Montré sur la page
1) • Plato de alineación (Mostrado en la página 1)
1
LIMITED WARRANTY
THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE
PRODUCT.
Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this
warranty are free from defects in materials or workmanship of the Company that exist at the time of sale by the Company and which
occur or exist within the applicable warranty period. Any distributor, sub-distributor, recipient, end-user and/or consumer agrees
that by accepting the receipt of the products, the distributor, sub-distributor, recipient, end user and/or consumer expressly agrees
to be bound by the terms of the warranty set forth herein.
I. APPLICABLE WARRANTY PERIOD
The products accompanied by this warranty shall be covered by this Limited Warranty for a period of 24 months from the date of
original purchase by the consumer. In the absence of suitable proof of purchase date, the warranty period of this product will begin
to run on the product's date of manufacture.
II. INSTRUCTIONS APPLICABLE TO THIS LIMITED WARRANTY
1. Consumers wishing to submit a warranty claim must return the products accompanied by this warranty to the point of purchase
for warranty consideration.
2. Upon discovery of a defect, any personal injury, property damage or any other type of resulting damage, if applicable, shall be
reasonably mitigated to the extent possible.
3. At its discretion, the Company may inspect products either at its facilities, or in the field, and after determination of a warranty claim, will, at its
option, repair or replace defective parts. Repaired or replaced parts will be returned freight prepaid by the Company.
4. This warranty policy does not cover any labor or shipping charges. The Company shall not be liable for any costs or charges
attributable to any product testing, maintenance, installation, repair or removal, or for any tools, supplies, or equipment needed
to install, repair, or remove any product.
III. LIMITATIONS APPLICABLE TO THIS LIMITED WARRANTY
THIS WARRANTY DOES NOT APPLY TO ANY OF THE FOLLOWING:
1. Brushes, impeller or cam on models with brush-type motors and/or flex-vane impellers.
2. Any product that is not installed, applied, maintained and used in accordance with the Company's published instructions,
applicable codes, applicable ordinances and/or with generally accepted industry standards.
3. Any product that has been subject to misuse, misapplication, neglect, alteration, accident, abuse, tampering, acts of God (including
lightning), acts of terrorism, acts of war, fire, improper storage or installation, improper use, improper maintenance or repair, damage or
casualty, or to an excess of the recommended maximums as set forth in the product instructions.
4. Any product that is operated with any accessory, equipment, component, or part not specifically approved by the Company.
5. Use of replacement parts not sold by the Company, the unauthorized addition of non-Company products to other Company
products, and the unauthorized alteration of Company products.
6. Products damaged by normal wear and tear, normal maintenance services and the parts used in connection with such service,
or any other conditions beyond the control of the Company.
7. Any product that has been used for purposes other than those for which it was designed and manufactured.
8. Any use of the product where installation instructions and/or instructions for use were not followed.
9. Products connected to voltage other than indicated on nameplate.
10. Products where the pump was exposed to any of the following: sand, gravel, cement, grease, plaster, mud, tar, hydrocarbons, hydrocarbon
derivatives (oil, gasoline, solvents, etc.) or other abrasive or corrosive substances.
11. Products in which the pump has been used to pump or circulate anything other than fresh water at room temperature.
12. Products in which the pump was allowed to operate dry (fluid supply cut off).
13. Products in which the sealed motor housing has been opened or the product has been otherwise dismantled by customer.
14. Products in which the cord has been cut to a length of less than three feet.
The Company reserves the right at any time, and from time to time, to make changes in the design and/or improvements upon its product
without thereby imposing any obligation upon itself to make corresponding changes or improvements in or upon its products already
manufactured and/or previously sold. The Company further reserves the right to substitute parts or components of substantially equal
quality in any warranty service required by operation of this Limited Warranty.
This written Limited Warranty is the entire warranty authorized and offered by the Company. There are no warranties or
representations beyond those expressed in this document.
THIS WARRANTY AND REMEDY IS IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES INCLUDING WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY SPECIFICALLY
DISCLAIMED AND EXPRESSLY EXCLUDED. CORRECTION OF NON-CONFORMITIES, IN THE MANNER AND FOR THE PERIOD OF TIME
AS SET FORTH ABOVE, SHALL CONSTITUTE FULFILLMENT OF ALL LIABILITY OF THE COMPANY TO THE PURCHASER WHETHER
BASED ON CONTRACT, NEGLIGENCE, OR OTHERWISE.
7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Little GIANT 506065 Installation guide

Category
Water pumps
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI