SWEBAD Borgholm 150 Installation guide

Type
Installation guide

SWEBAD Borgholm 150 is a versatile bathtub with a variety of features to enhance your bathing experience. Its spacious interior, measuring 149x70x64 cm with a volume of 190 liters, provides ample room to relax and unwind. Immerse yourself in a soothing soak while enjoying the convenience of built-in heating options, available in different power ratings to suit your needs. Choose from standard, better, design, or luxury systems, with corresponding power ratings ranging from 900W to 2000W. Additionally, you can opt for a 1.5kW or 3.0kW heater to further customize your bathing experience.

SWEBAD Borgholm 150 is a versatile bathtub with a variety of features to enhance your bathing experience. Its spacious interior, measuring 149x70x64 cm with a volume of 190 liters, provides ample room to relax and unwind. Immerse yourself in a soothing soak while enjoying the convenience of built-in heating options, available in different power ratings to suit your needs. Choose from standard, better, design, or luxury systems, with corresponding power ratings ranging from 900W to 2000W. Additionally, you can opt for a 1.5kW or 3.0kW heater to further customize your bathing experience.

BORGHOLM 150
TT: 149 x 70 x 64 cm VOLYM: 190 l.
INSTALLATIONSGUIDE TECHNICAL DATA
SWE
GBR Length of the power cable min. 2 m. Thickness of cable and number of cores depends on
performance of the device and should meet the local requirements. Connections must be
made by an authorised electrician.
Closable cold and hot water input G ½.
Sewage opening D = 50 mm
Strömkabelns längd ska vara minst 2 meter lång. Kabeltjocklek och antal kärnor beror på
enhetens prestanda och måste uppfylla de lokala kraven. Anslutningar måste utföras av en
auktoriserad elektriker.
Kall -och varmvattenanslutning G ½.
Avloppsöppning diameter = 50 mm
1
1
2
2
3
3
System
OBS! Värmare ingår i vissa system/ NB! Heater is included in some systems
Standard
Bra
Bättre
Design
Lyx
1,5 kW (Bättre, Design)
3,0 kW (Lyx)
-
230 V
230 V
230 V
230 V
230 V
230 V
-
900 W
1400 W
1500 W
2000 W
1500 W
3000 W
-
4,7 A
6,9 A
6,6 A
8,8 A
6,6 A
13,0 A
Spänning
Voltage
Effekt
Rated power
Ström
Rated current
V. 2021-12
500
100
100
470
200
370
300
700
400
150
200
350
200
550
150mm
Max 40mm
70
47
64
149
106
40
70
47
64
149
106
40
L1
  
  
L2
N
PE
N
5x2,5mm
3x2,5mm
PE
L2
L1
L
N
PE
  
L
N
PE
N
3x4,0mm
1x2,5mm
PE
L
N
PE
L
Koppling
Switchboard
Kopplingsdosa
Junction Box
Diagram 2
(med värmare)
(with heater)
Diagram 1
Diagram 3
(med värmare)
(with heater)
V. 2021-12
GBR ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be executed by a certified
professional electrician.
At connecting, all local regulations must be observed as well as permissible load on one phase. To achieve
local auxiliary equipotential bonding, make sure you connect all conductive objects in the same room with
the earthing terminal of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum of 2.5 sq mm. The power
circuit of the product must be protected with a residual current circuit breaker with 30mA threshold and
a circuit breaker the operating current of which is levelled with the consumed current of the product. The
product is connected to the electrical power line as a stationary device, with no plug connector. The length
of the power line should allow moving the product away from walls if necessary. Options for
connecting to the power network according to local opportunities are given on the diagrams below.
SWE ELSPECIFIKATION
Alla elektriska anslutningar relaterade till installationen av produkten måste utföras av en certifierad
professionell elektriker.
Vid anslutning måste alla lokala föreskrifter följas samt tillåten belastning på en fas följas. För att potential-
utjämna, se till att du ansluter alla ledande föremål i samma rum med jordskenan på produktens aluminium-
ram: Tvärsnittet av jordledningen måste vara minst 2,5 mm. Produktens effektkrets måste skyddas med en
jordfelsbrytare med 30mA tröskel och en strömbrytare/säkring vars driftsström är samma som produktens
förbrukade ström. Produkten ska fastanslutas. Kraftledningen längd bör vara tillräckligt lång
för att kunna förflytta produkten en bit från väggen om det blir nödvändigt. Alternativ för anslutning till
elnätet enligt lokala möjligheter ges i diagrammen nedan.
1. Strömnät (230V, 50 Hz)
Power network (230V, 50Hz)
2. Strömbrytare
Circuit-breaker
3. Jordfelsbrytare
Residual current circuit breaker
4. Badterminaler
Bath terminals
BORGHOLM 160
TT: 159 x 70 x 65 cm VOLYM: 210 l.
INSTALLATIONSGUIDE TECHNICAL DATA
SWE
GBR Length of the power cable min. 2 m. Thickness of cable and number of cores depends on
performance of the device and should meet the local requirements. Connections must be
made by an authorised electrician.
Closable cold and hot water input G ½.
Sewage opening D = 50 mm
Strömkabelns längd ska vara minst 2 meter lång. Kabeltjocklek och antal kärnor beror på
enhetens prestanda och måste uppfylla de lokala kraven. Anslutningar måste utföras av en
auktoriserad elektriker.
Kall -och varmvattenanslutning G ½.
Avloppsöppning diameter = 50 mm
1
1
2
2
3
3
System
OBS! Värmare ingår i vissa system/ NB! Heater is included in some systems
Standard
Bra
Bättre
Design
Lyx
1,5 kW (Bättre, Design)
3,0 kW (Lyx)
-
230 V
230 V
230 V
230 V
230 V
230 V
-
900 W
1400 W
1500 W
2000 W
1500 W
3000 W
-
4,7 A
6,9 A
6,6 A
8,8 A
6,6 A
13,0 A
Spänning
Voltage
Effekt
Rated power
Ström
Rated current
V. 2021-12
150
100
100
470
100
470
350
750
400
130
100
100
150mm
Max 40mm
70
54
40
48
65
159
30
114
70
54
40
48
65
159
30
114
L1
  
  
L2
N
PE
N
5x2,5mm
3x2,5mm
PE
L2
L1
L
N
PE
  
L
N
PE
N
3x4,0mm
1x2,5mm
PE
L
N
PE
L
Koppling
Switchboard
Kopplingsdosa
Junction Box
Diagram 2
(med värmare)
(with heater)
Diagram 1
Diagram 3
(med värmare)
(with heater)
V. 2021-12
GBR ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be executed by a certified
professional electrician.
At connecting, all local regulations must be observed as well as permissible load on one phase. To achieve
local auxiliary equipotential bonding, make sure you connect all conductive objects in the same room with
the earthing terminal of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum of 2.5 sq mm. The power
circuit of the product must be protected with a residual current circuit breaker with 30mA threshold and
a circuit breaker the operating current of which is levelled with the consumed current of the product. The
product is connected to the electrical power line as a stationary device, with no plug connector. The length
of the power line should allow moving the product away from walls if necessary. Options for
connecting to the power network according to local opportunities are given on the diagrams below.
SWE ELSPECIFIKATION
Alla elektriska anslutningar relaterade till installationen av produkten måste utföras av en certifierad
professionell elektriker.
Vid anslutning måste alla lokala föreskrifter följas samt tillåten belastning på en fas följas. För att potential-
utjämna, se till att du ansluter alla ledande föremål i samma rum med jordskenan på produktens aluminium-
ram: Tvärsnittet av jordledningen måste vara minst 2,5 mm. Produktens effektkrets måste skyddas med en
jordfelsbrytare med 30mA tröskel och en strömbrytare/säkring vars driftsström är samma som produktens
förbrukade ström. Produkten ska fastanslutas. Kraftledningen längd bör vara tillräckligt lång
för att kunna förflytta produkten en bit från väggen om det blir nödvändigt. Alternativ för anslutning till
elnätet enligt lokala möjligheter ges i diagrammen nedan.
1. Strömnät (230V, 50 Hz)
Power network (230V, 50Hz)
2. Strömbrytare
Circuit-breaker
3. Jordfelsbrytare
Residual current circuit breaker
4. Badterminaler
Bath terminals
BORGHOLM 170
TT: 169 x 75 x 67 cm VOLYM: 265 l.
INSTALLATIONSGUIDE TECHNICAL DATA
SWE
GBR Length of the power cable min. 2 m. Thickness of cable and number of cores depends on
performance of the device and should meet the local requirements. Connections must be
made by an authorised electrician.
Closable cold and hot water input G ½.
Sewage opening D = 50 mm
Strömkabelns längd ska vara minst 2 meter lång. Kabeltjocklek och antal kärnor beror på
enhetens prestanda och måste uppfylla de lokala kraven. Anslutningar måste utföras av en
auktoriserad elektriker.
Kall -och varmvattenanslutning G ½.
Avloppsöppning diameter = 50 mm
1
1
2
2
3
3
System
OBS! Värmare ingår i vissa system/ NB! Heater is included in some systems
Standard
Bra
Bättre
Design
Lyx
1,5 kW (Bättre, Design)
3,0 kW (Lyx)
-
230 V
230 V
230 V
230 V
230 V
230 V
-
900 W
1400 W
1500 W
2000 W
1500 W
3000 W
-
4,7 A
6,9 A
6,6 A
8,8 A
6,6 A
13,0 A
Spänning
Voltage
Effekt
Rated power
Ström
Rated current
V. 2021-12
150
100
100
470
100
470
750
400
400
130
100
100
150mm
Max 40mm
75
59
44
50
67
169
30
120
75
59
44
50
67
169
30
120
L1
  
  
L2
N
PE
N
5x2,5mm
3x2,5mm
PE
L2
L1
L
N
PE
  
L
N
PE
N
3x4,0mm
1x2,5mm
PE
L
N
PE
L
Koppling
Switchboard
Kopplingsdosa
Junction Box
Diagram 2
(med värmare)
(with heater)
Diagram 1
Diagram 3
(med värmare)
(with heater)
V. 2021-12
GBR ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be executed by a certified
professional electrician.
At connecting, all local regulations must be observed as well as permissible load on one phase. To achieve
local auxiliary equipotential bonding, make sure you connect all conductive objects in the same room with
the earthing terminal of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum of 2.5 sq mm. The power
circuit of the product must be protected with a residual current circuit breaker with 30mA threshold and
a circuit breaker the operating current of which is levelled with the consumed current of the product. The
product is connected to the electrical power line as a stationary device, with no plug connector. The length
of the power line should allow moving the product away from walls if necessary. Options for
connecting to the power network according to local opportunities are given on the diagrams below.
SWE ELSPECIFIKATION
Alla elektriska anslutningar relaterade till installationen av produkten måste utföras av en certifierad
professionell elektriker.
Vid anslutning måste alla lokala föreskrifter följas samt tillåten belastning på en fas följas. För att potential-
utjämna, se till att du ansluter alla ledande föremål i samma rum med jordskenan på produktens aluminium-
ram: Tvärsnittet av jordledningen måste vara minst 2,5 mm. Produktens effektkrets måste skyddas med en
jordfelsbrytare med 30mA tröskel och en strömbrytare/säkring vars driftsström är samma som produktens
förbrukade ström. Produkten ska fastanslutas. Kraftledningen längd bör vara tillräckligt lång
för att kunna förflytta produkten en bit från väggen om det blir nödvändigt. Alternativ för anslutning till
elnätet enligt lokala möjligheter ges i diagrammen nedan.
1. Strömnät (230V, 50 Hz)
Power network (230V, 50Hz)
2. Strömbrytare
Circuit-breaker
3. Jordfelsbrytare
Residual current circuit breaker
4. Badterminaler
Bath terminals
BORGHOLM 180
TT: 179 x 80 x 68 cm VOLYM: 300 l.
INSTALLATIONSGUIDE TECHNICAL DATA
SWE
GBR Length of the power cable min. 2 m. Thickness of cable and number of cores depends on
performance of the device and should meet the local requirements. Connections must be
made by an authorised electrician.
Closable cold and hot water input G ½.
Sewage opening D = 50 mm
Strömkabelns längd ska vara minst 2 meter lång. Kabeltjocklek och antal kärnor beror på
enhetens prestanda och måste uppfylla de lokala kraven. Anslutningar måste utföras av en
auktoriserad elektriker.
Kall -och varmvattenanslutning G ½.
Avloppsöppning diameter = 50 mm
1
1
2
2
3
3
System
OBS! Värmare ingår i vissa system/ NB! Heater is included in some systems
Standard
Bra
Bättre
Design
Lyx
1,5 kW (Bättre, Design)
3,0 kW (Lyx)
-
230 V
230 V
230 V
230 V
230 V
230 V
-
900 W
1400 W
1500 W
2000 W
1500 W
3000 W
-
4,7 A
6,9 A
6,6 A
8,8 A
6,6 A
13,0 A
Spänning
Voltage
Effekt
Rated power
Ström
Rated current
V. 2021-12
400
100
200
400
180
370
400
800
500
100
150
100
400
350
150mm
Max 40mm
80
62
47
51
68
179
30
126
80
62
47
51
68
179
30
126
L1
  
  
L2
N
PE
N
5x2,5mm
3x2,5mm
PE
L2
L1
L
N
PE
  
L
N
PE
N
3x4,0mm
1x2,5mm
PE
L
N
PE
L
Koppling
Switchboard
Kopplingsdosa
Junction Box
Diagram 2
(med värmare)
(with heater)
Diagram 1
Diagram 3
(med värmare)
(with heater)
V. 2021-12
GBR ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be executed by a certified
professional electrician.
At connecting, all local regulations must be observed as well as permissible load on one phase. To achieve
local auxiliary equipotential bonding, make sure you connect all conductive objects in the same room with
the earthing terminal of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum of 2.5 sq mm. The power
circuit of the product must be protected with a residual current circuit breaker with 30mA threshold and
a circuit breaker the operating current of which is levelled with the consumed current of the product. The
product is connected to the electrical power line as a stationary device, with no plug connector. The length
of the power line should allow moving the product away from walls if necessary. Options for
connecting to the power network according to local opportunities are given on the diagrams below.
SWE ELSPECIFIKATION
Alla elektriska anslutningar relaterade till installationen av produkten måste utföras av en certifierad
professionell elektriker.
Vid anslutning måste alla lokala föreskrifter följas samt tillåten belastning på en fas följas. För att potential-
utjämna, se till att du ansluter alla ledande föremål i samma rum med jordskenan på produktens aluminium-
ram: Tvärsnittet av jordledningen måste vara minst 2,5 mm. Produktens effektkrets måste skyddas med en
jordfelsbrytare med 30mA tröskel och en strömbrytare/säkring vars driftsström är samma som produktens
förbrukade ström. Produkten ska fastanslutas. Kraftledningen längd bör vara tillräckligt lång
för att kunna förflytta produkten en bit från väggen om det blir nödvändigt. Alternativ för anslutning till
elnätet enligt lokala möjligheter ges i diagrammen nedan.
1. Strömnät (230V, 50 Hz)
Power network (230V, 50Hz)
2. Strömbrytare
Circuit-breaker
3. Jordfelsbrytare
Residual current circuit breaker
4. Badterminaler
Bath terminals
BORGHOLM XL 190
TT: 190 x 86 x 67 cm VOLYM: 330 l.
INSTALLATIONSGUIDE TECHNICAL DATA
SWE
GBR Length of the power cable min. 2 m. Thickness of cable and number of cores depends on
performance of the device and should meet the local requirements. Connections must be
made by an authorised electrician.
Closable cold and hot water input G ½.
Sewage opening D = 50 mm
Strömkabelns längd ska vara minst 2 meter lång. Kabeltjocklek och antal kärnor beror på
enhetens prestanda och måste uppfylla de lokala kraven. Anslutningar måste utföras av en
auktoriserad elektriker.
Kall -och varmvattenanslutning G ½.
Avloppsöppning diameter = 50 mm
1
1
2
2
3
3
System
OBS! Värmare ingår i vissa system/ NB! Heater is included in some systems
Standard
Bra
Bättre
Design
Lyx
1,5 kW (Bättre, Design)
3,0 kW (Lyx)
-
230 V
230 V
230 V
230 V
230 V
230 V
-
1100 W
1600 W
1500 W
2000 W
1500 W
3000 W
-
4,7 A
6,9 A
6,6 A
8,8 A
6,6 A
13,0 A
Spänning
Voltage
Effekt
Rated power
Ström
Rated current
V. 2021-12
150mm
Max 40mm
400
50
270
400
400
400
260
140
260
140
250
400
400
200
550
100
51
67
86
120
190
68
53
51
67
86
120
190
68
53
L1
  
  
L2
N
PE
N
5x2,5mm
3x2,5mm
PE
L2
L1
L
N
PE
  
L
N
PE
N
3x4,0mm
1x2,5mm
PE
L
N
PE
L
Koppling
Switchboard
Kopplingsdosa
Junction Box
Diagram 2
(med värmare)
(with heater)
Diagram 1
Diagram 3
(med värmare)
(with heater)
V. 2021-12
GBR ELECTRIC SPECIFICATION
All electrical connections related to the installation of the product must be executed by a certified
professional electrician.
At connecting, all local regulations must be observed as well as permissible load on one phase. To achieve
local auxiliary equipotential bonding, make sure you connect all conductive objects in the same room with
the earthing terminal of the product’s aluminium frame:
The cross-section of the copper earth continuity connector must be a minimum of 2.5 sq mm. The power
circuit of the product must be protected with a residual current circuit breaker with 30mA threshold and
a circuit breaker the operating current of which is levelled with the consumed current of the product. The
product is connected to the electrical power line as a stationary device, with no plug connector. The length
of the power line should allow moving the product away from walls if necessary. Options for
connecting to the power network according to local opportunities are given on the diagrams below.
SWE ELSPECIFIKATION
Alla elektriska anslutningar relaterade till installationen av produkten måste utföras av en certifierad
professionell elektriker.
Vid anslutning måste alla lokala föreskrifter följas samt tillåten belastning på en fas följas. För att potential-
utjämna, se till att du ansluter alla ledande föremål i samma rum med jordskenan på produktens aluminium-
ram: Tvärsnittet av jordledningen måste vara minst 2,5 mm. Produktens effektkrets måste skyddas med en
jordfelsbrytare med 30mA tröskel och en strömbrytare/säkring vars driftsström är samma som produktens
förbrukade ström. Produkten ska fastanslutas. Kraftledningen längd bör vara tillräckligt lång
för att kunna förflytta produkten en bit från väggen om det blir nödvändigt. Alternativ för anslutning till
elnätet enligt lokala möjligheter ges i diagrammen nedan.
1. Strömnät (230V, 50 Hz)
Power network (230V, 50Hz)
2. Strömbrytare
Circuit-breaker
3. Jordfelsbrytare
Residual current circuit breaker
4. Badterminaler
Bath terminals
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

SWEBAD Borgholm 150 Installation guide

Type
Installation guide

SWEBAD Borgholm 150 is a versatile bathtub with a variety of features to enhance your bathing experience. Its spacious interior, measuring 149x70x64 cm with a volume of 190 liters, provides ample room to relax and unwind. Immerse yourself in a soothing soak while enjoying the convenience of built-in heating options, available in different power ratings to suit your needs. Choose from standard, better, design, or luxury systems, with corresponding power ratings ranging from 900W to 2000W. Additionally, you can opt for a 1.5kW or 3.0kW heater to further customize your bathing experience.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages